Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomimetics (Basel) ; 9(4)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38667203

RESUMEN

A versatile and robust procedure is developed that allows the identification of individual target molecules using antibodies bound to a DeepTipTM functionalized atomic-force microscopy probe. The model system used for the validation of this process consists of a biotinylated anti-lactate dehydrogenase antibody immobilized on a streptavidin-decorated AFM probe. Lactate dehydrogenase (LDH) is employed as target molecule and covalently immobilized on functionalized MicroDeckTM substrates. The interaction between sensor and target molecules is explored by recording force-displacement (F-z) curves with an atomic-force microscope. F-z curves that correspond to the genuine sensor-target molecule interaction are identified based on the following three criteria: (i) number of peaks, (ii) value of the adhesion force, and (iii) presence or absence of the elastomeric trait. The application of these criteria leads to establishing seven groups, ranging from no interaction to multiple sensor-target molecule interactions, for which force-displacement curves are classified. The possibility of recording consistently single-molecule interaction events between an antibody and its specific antigen, in combination with the high proportion of successful interaction events obtained, increases remarkably the possibilities offered by affinity atomic-force microscopy for the characterization of biological and biomimetic systems from the molecular to the tissue scales.

2.
J Mech Behav Biomed Mater ; 63: 1-9, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27337412

RESUMEN

The aim of this study was to evaluate quantitatively the fracture-by tear and delamination-of bovine pericardium tissues which are usually employed for the manufacture of bioprosthetic valves. A large number of samples (77) were tested in root-to-apex and circumferential directions, according to a standardised tear test (ASTM D 1938). Before performing the tear test, some samples were subjected to 1000 cycles of fatigue to a maximum stress of 3MPa. Fracture toughness of tearing and delamination were computed by following a simple fracture model. The study showed significantly lower values of delamination toughness compared with tear delamination. Moreover, tear forces were different in each test direction, revealing a clear orthotropic behaviour. All these results, as well as the testing procedure, could be of value for future research in the physiological function of pericardium tissues and clinical applications.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Pericardio/patología , Animales , Bovinos
3.
Artículo en Inglés | MEDLINE | ID: mdl-21480018

RESUMEN

This work presents experiments and modelling aimed at characterising the passive mechanical behaviour of the human thoracic descending aorta. To this end, uniaxial tension and pressurisation tests on healthy samples corresponding to newborn, young and adult arteries are performed. Then, the tensile measurements are used to calibrate the material parameters of the Holzapfel constitutive model. This model is found to adequately adjust the material behaviour in a wide deformation range; in particular, it captures the progressive stiffness increase and the anisotropy due to the stretching of the collagen fibres. Finally, the assessment of these material parameters in the modelling of the pressurisation test is addressed. The implication of this study is the possibility to predict the mechanical response of the human thoracic descending aorta under generalised loading states like those that can occur in physiological conditions and/or in medical device applications.


Asunto(s)
Aorta Torácica/fisiopatología , Modelos Biológicos , Humanos
4.
Phys Med Biol ; 53(17): 4543-54, 2008 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-18677037

RESUMEN

Viscoelastic models can be used to better understand arterial wall mechanics in physiological and pathological conditions. The arterial wall reveals very slow time-dependent decays in uniaxial stress-relaxation experiments, coherent with weak power-law functions. Quasi-linear viscoelastic (QLV) theory was successfully applied to modeling such responses, but an accurate estimation of the reduced relaxation function parameters can be very difficult. In this work, an alternative relaxation function based on fractional calculus theory is proposed to describe stress relaxation experiments in strips cut from healthy human aortas. Stress relaxation (1 h) was registered at three incremental stress levels. The novel relaxation function with three parameters was integrated into the QLV theory to fit experimental data. It was based in a modified Voigt model, including a fractional element of order alpha, called spring-pot. The stress-relaxation prediction was accurate and fast. Sensitivity plots for each parameter presented a minimum near their optimal values. Least-squares errors remained below 2%. Values of order alpha = 0.1-0.3 confirmed a predominant elastic behavior. The other two parameters of the model can be associated to elastic and viscous constants that explain the time course of the observed relaxation function. The fractional-order model integrated into the QLV theory proved to capture the essential features of the arterial wall mechanical response.


Asunto(s)
Arterias/patología , Adulto , Aorta/patología , Biofisica/métodos , Elasticidad , Femenino , Humanos , Análisis de los Mínimos Cuadrados , Masculino , Persona de Mediana Edad , Modelos Estadísticos , Modelos Teóricos , Reproducibilidad de los Resultados , Resistencia a la Tracción , Viscosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...