Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Space Sci Rev ; 217(3): 48, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34776548

RESUMEN

NASA's Mars 2020 (M2020) rover mission includes a suite of sensors to monitor current environmental conditions near the surface of Mars and to constrain bulk aerosol properties from changes in atmospheric radiation at the surface. The Mars Environmental Dynamics Analyzer (MEDA) consists of a set of meteorological sensors including wind sensor, a barometer, a relative humidity sensor, a set of 5 thermocouples to measure atmospheric temperature at ∼1.5 m and ∼0.5 m above the surface, a set of thermopiles to characterize the thermal IR brightness temperatures of the surface and the lower atmosphere. MEDA adds a radiation and dust sensor to monitor the optical atmospheric properties that can be used to infer bulk aerosol physical properties such as particle size distribution, non-sphericity, and concentration. The MEDA package and its scientific purpose are described in this document as well as how it responded to the calibration tests and how it helps prepare for the human exploration of Mars. A comparison is also presented to previous environmental monitoring payloads landed on Mars on the Viking, Pathfinder, Phoenix, MSL, and InSight spacecraft.

2.
Vox Sang ; 72(1): 26-30, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9031497

RESUMEN

BACKGROUND AND OBJECTIVES: Serologic agglutination tests have the disadvantage of lack of an objective endpoint that can be easily read and quantitated. We have developed a new method for ABO and Rh typing based on producing a red blood cell (RBC) monolayer on microplates and the mixed hemagglutination reaction. MATERIALS AND METHODS: We have employed a new red cell fixation buffer to prepare the RBC monolayer. As the technique for grouping, we used a mixed agglutination reaction between the RBC monolayer and the RBCs to be typed. RESULTS: Compared with an automated hemagglutination system in 34,519 samples, the method is shown to be more sensitive, free of false positive reactions, and cost-effective. CONCLUSIONS: The microplate coagglutination method is accurate and lower in cost than conventional methods.


Asunto(s)
Tipificación y Pruebas Cruzadas Sanguíneas/métodos , Eritrocitos/inmunología , Tipificación y Pruebas Cruzadas Sanguíneas/instrumentación , Tampones (Química) , Hemaglutinación , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...