1.
Sci Rep ; 11(1): 17315, 2021 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-34453096

RESUMEN

This study was aimed to compare the vascular healing process of a SYNERGY stent with that of a PROMUS PREMIER stent in patients with acute coronary syndrome (ACS). In 71 patients with ACS, undergoing coronary stent implantation using the SYNERGY stent (n = 52) or PROMUS PREMIER stent (n = 19), we measured circulating CD34+/CD133+/CD45null cells and CD34+/KDR+ cells and observed vascular healing at the stented sites using optical coherence tomography (OCT) and coronary angioscopy. On the day 7, circulating CD34+/CD133+/CD45null cells increased in SYNERGY group (P < 0.0001), while it did not change in PROMUS group. The CD34+/KDR+ cells also increased in SYNERGY group (P < 0.0001) but less significantly in the PROMUS group (P < 0.05). The OCT-based neointimal thickness (P < 0.0005) and neointimal coverage rate (P < 0.05) at 12 months were greater in SYNERGY group, compared with PROMUS group. The coronary angioscopy-based neointimal coverage grade at 12 months was also greater in SYNERGY group (P < 0.001). In overall patients, the change in CD34+/KDR+ cells on the day 7 correlated with the OCT-based neointimal thickness at 12 months (R = 0.288, P < 0.05). SYNERGY stent seems to have potential advantages over PROMUS PREMIER stent for ACS patients in terms of vascular healing process at the stented sites.


Asunto(s)
Síndrome Coronario Agudo/terapia , Implantación de Prótesis/métodos , Células Madre/metabolismo , Cicatrización de Heridas/efectos de los fármacos , Anciano , Antígenos CD/metabolismo , Ensayos Clínicos como Asunto , Angiografía Coronaria , Vasos Coronarios , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Neointima/metabolismo , Stents , Tomografía de Coherencia Óptica , Resultado del Tratamiento
2.
Int J Cardiovasc Imaging ; 35(11): 1971-1978, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31218524

RESUMEN

Normalized optical density (NOD) measured by optical coherence tomography represents neointimal maturity after coronary stent implantation and is correlated with morphologic information provided by both light and electron microscopy. We aimed to test the hypothesis that even second generation drug-eluting stents (DESs) are problematic in terms of neointimal maturity. We implanted bare-metal stents (BMS: n = 14), everolimus-eluting stents (EESs: n = 15) or zotarolimus-eluting stents (ZESs: n = 12) at 41 sites in 32 patients with stable coronary artery disease. OCT was performed at up to 12 months of follow-up, and the average optical density of neointima covering struts was evaluated. NOD was calculated as the optical density of stent-strut covering tissue divided by the optical density of the struts. We also measured circulating CD34+ /CD133+ /CD45low cells, and serum levels of stromal cell-derived factor (SDF)-1, interleukin (IL)-8 and matrix metalloproteinase (MMP)-9 at baseline and follow-up. NOD was lower in the EES (0.70 ± 0.06) group than in the BMS (0.76 ± 0.07, P < 0.05) and ZES (0.76 ± 0.06, P < 0.05) groups. The mean neointimal area (R = 0.33, P < 0.05) and mean neointimal thickness (R = 0.37, P < 0.05) were correlated with NOD. Although NOD was not correlated with percent changes in circulating endothelial progenitor cells, and the levels of SDF-1 and IL-8, it was negatively correlated with the change in MMP-9 level (R = - 0.51, P < 0.01). Neointimal maturity might be lower at EES sites than BMS or ZES sites. This might lead to impaired neointimal tissue growth and matrix degradation. These results suggest a specific pathophysiology after DES implantation.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Neointima , Intervención Coronaria Percutánea/instrumentación , Tomografía de Coherencia Óptica , Anciano , Anciano de 80 o más Años , Fármacos Cardiovasculares/administración & dosificación , Quimiocina CXCL12/sangre , Enfermedad de la Arteria Coronaria/sangre , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Vasos Coronarios/metabolismo , Vasos Coronarios/fisiopatología , Células Progenitoras Endoteliales/metabolismo , Células Progenitoras Endoteliales/patología , Everolimus/administración & dosificación , Femenino , Humanos , Interleucina-8/sangre , Masculino , Metaloproteinasa 9 de la Matriz/sangre , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Factores de Tiempo , Resultado del Tratamiento , Remodelación Vascular
3.
J Am Coll Cardiol ; 70(22): 2752-2763, 2017 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-29191323

RESUMEN

BACKGROUND: Limited data exist about safety and efficacy of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (AR). OBJECTIVES: This study sought to compare the outcomes of TAVR with early- and new-generation devices in symptomatic patients with pure native AR. METHODS: From the pure native AR TAVR multicenter registry, procedural and clinical outcomes were assessed according to VARC-2 criteria and compared between early- and new-generation devices. RESULTS: A total of 331 patients with a mean STS score of 6.7 ± 6.7 underwent TAVR. The early- and new-generation devices were used in 119 patients (36.0%) and 212 patients (64.0%), respectively. STS score tended to be lower in the new-generation device group (6.2 ± 6.7 vs. 7.6 ± 6.7; p = 0.08), but transfemoral access was more frequently used in the early-generation device group (87.4% vs. 60.8%; p < 0.001). Compared with the early-generation devices, the new-generation devices were associated with a significantly higher device success rate (81.1% vs. 61.3%; p < 0.001) due to lower rates of second valve implantation (12.7% vs. 24.4%; p = 0.007) and post-procedural AR ≥ moderate (4.2% vs. 18.8%; p < 0.001). There were no significant differences in major 30-day endpoints between the 2 groups. The cumulative rates of all-cause and cardiovascular death at 1-year follow-up were 24.1% and 15.6%, respectively. The 1-year all-cause mortality rate was significantly higher in the patients with post-procedural AR ≥ moderate compared with those with post-procedural AR ≤ mild (46.1% vs. 21.8%; log-rank p = 0.001). On multivariable analysis, post-procedural AR ≥ moderate was independently associated with 1-year all-cause mortality (hazard ratio: 2.85; 95% confidence interval: 1.52 to 5.35; p = 0.001). CONCLUSIONS: Compared with the early-generation devices, TAVR using the new-generation devices was associated with improved procedural outcomes in treating patients with pure native AR. In patients with pure native AR, significant post-procedural AR was independently associated with increased mortality.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica/cirugía , Arteria Femoral/cirugía , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/cirugía , Cateterismo Periférico/métodos , Cateterismo Periférico/estadística & datos numéricos , Femenino , Prótesis Valvulares Cardíacas/efectos adversos , Prótesis Valvulares Cardíacas/normas , Humanos , Cooperación Internacional , Masculino , Mortalidad , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis/tendencias , Mejoramiento de la Calidad , Sistema de Registros/estadística & datos numéricos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos
4.
J Am Coll Cardiol ; 70(9): 1121-1131, 2017 Aug 29.
Artículo en Inglés | MEDLINE | ID: mdl-28838360

RESUMEN

BACKGROUND: Limited data exist regarding transcatheter mitral valve replacement (TMVR) for patients with failed mitral valve replacement and repair. OBJECTIVES: This study sought to evaluate the outcomes of TMVR in patients with failed mitral bioprosthetic valves (valve-in-valve [ViV]) and annuloplasty rings (valve-in-ring [ViR]). METHODS: From the TMVR multicenter registry, procedural and clinical outcomes of mitral ViV and ViR were compared according to Mitral Valve Academic Research Consortium criteria. RESULTS: A total of 248 patients with mean Society of Thoracic Surgeons score of 8.9 ± 6.8% underwent TMVR. Transseptal access and the balloon-expandable valve were used in 33.1% and 89.9%, respectively. Compared with 176 patients undergoing ViV, 72 patients undergoing ViR had lower left ventricular ejection fraction (45.6 ± 17.4% vs. 55.3 ± 11.1%; p < 0.001). Overall technical and device success rates were acceptable, at 92.3% and 85.5%, respectively. However, compared with the ViV group, the ViR group had lower technical success (83.3% vs. 96.0%; p = 0.001) due to more frequent second valve implantation (11.1% vs. 2.8%; p = 0.008), and lower device success (76.4% vs. 89.2%; p = 0.009) due to more frequent reintervention (16.7% vs. 7.4%; p = 0.03). Mean mitral valve gradients were similar between groups (6.4 ± 2.3 mm Hg vs. 5.8 ± 2.7 mm Hg; p = 0.17), whereas the ViR group had more frequent post-procedural mitral regurgitation moderate or higher (19.4% vs. 6.8%; p = 0.003). Furthermore, the ViR group had more frequent life-threatening bleeding (8.3% vs. 2.3%; p = 0.03), acute kidney injury (11.1% vs. 4.0%; p = 0.03), and subsequent lower procedural success (58.3% vs. 79.5%; p = 0.001). The 1-year all-cause mortality rate was significantly higher in the ViR group compared with the ViV group (28.7% vs. 12.6%; log-rank test, p = 0.01). On multivariable analysis, failed annuloplasty ring was independently associated with all-cause mortality (hazard ratio: 2.70; 95% confidence interval: 1.34 to 5.43; p = 0.005). CONCLUSIONS: The TMVR procedure provided acceptable outcomes in high-risk patients with degenerated bioprostheses or failed annuloplasty rings, but mitral ViR was associated with higher rates of procedural complications and mid-term mortality compared with mitral ViV.


Asunto(s)
Bioprótesis/efectos adversos , Cateterismo Cardíaco/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anuloplastia de la Válvula Mitral/efectos adversos , Válvula Mitral/cirugía , Anciano , Europa (Continente)/epidemiología , Femenino , Humanos , Masculino , América del Norte/epidemiología , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA