Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 143
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38599918

RESUMEN

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

2.
N Engl J Med ; 2024 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-38587261

RESUMEN

BACKGROUND: Patients with severe aortic stenosis and a small aortic annulus are at risk for impaired valvular hemodynamic performance and associated adverse cardiovascular clinical outcomes after transcatheter aortic-valve replacement (TAVR). METHODS: We randomly assigned patients with symptomatic severe aortic stenosis and an aortic-valve annulus area of 430 mm2 or less in a 1:1 ratio to undergo TAVR with either a self-expanding supraannular valve or a balloon-expandable valve. The coprimary end points, each assessed through 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (tested for noninferiority) and a composite end point measuring bioprosthetic-valve dysfunction (tested for superiority). RESULTS: A total of 716 patients were treated at 83 sites in 13 countries (mean age, 80 years; 87% women; mean Society of Thoracic Surgeons Predicted Risk of Mortality, 3.3%). The Kaplan-Meier estimate of the percentage of patients who died, had a disabling stroke, or were rehospitalized for heart failure through 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (difference, -1.2 percentage points; 90% confidence interval [CI], -4.9 to 2.5; P<0.001 for noninferiority). The Kaplan-Meier estimate of the percentage of patients with bioprosthetic-valve dysfunction through 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (difference, -32.2 percentage points; 95% CI, -38.7 to -25.6; P<0.001 for superiority). The aortic-valve mean gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve, and the corresponding values for additional secondary end points through 12 months were as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic-valve dysfunction, 10.2% and 43.3% (all P<0.001). Moderate or severe prosthesis-patient mismatch at 30 days was found in 11.2% of the patients in the self-expanding valve group and 35.3% of those in the balloon-expandable valve group (P<0.001). Major safety end points appeared to be similar in the two groups. CONCLUSIONS: Among patients with severe aortic stenosis and a small aortic annulus who underwent TAVR, a self-expanding supraannular valve was noninferior to a balloon-expandable valve with respect to clinical outcomes and was superior with respect to bioprosthetic-valve dysfunction through 12 months. (Funded by Medtronic; SMART ClinicalTrials.gov number, NCT04722250.).

3.
Catheter Cardiovasc Interv ; 103(1): 129-136, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37786977

RESUMEN

BACKGROUND: While studies have shown the advantages of computed tomography angiography (CTA) over transesophageal echocardiography (TEE) in left atrial appendage closure (LAAC) preprocedural planning for WATCHMAN™ legacy and FLX devices, there has been no reported long-term data for this approach. OBJECTIVES: We sought to evaluate long-term outcomes using CTA-based preprocedural planning for LAAC using the WATCHMAN™ device. METHODS: A prospective analysis of 231 consecutive patients who underwent LAAC in a single, large academic hospital in the United States was conducted over a 5-year period. CTA-guided preprocedural planning was performed in all. Procedural success, adverse events, length of procedure, number of devices used, and length of stay were evaluated. Rates of death, cerebral embolism, systemic embolism, and major and minor bleeding were recorded. Adjusted predicted stroke and major bleeding rates were derived from CHA2DS2-Vasc and HAS-BLED scores, respectively. RESULTS: From January 26, 2017, to November 23, 2021, 231 patients underwent LAAC with CTA preprocedural planning by two operating physicians. The mean age of patients was 76.5 ± 8.4. 59.7% of patients were male. Mean CHA2DS2VASc and HAS-BLED scores were 4.5 ± 1.4 and 3.9 ± 0.9, respectively. All procedures were performed with intracardiac echo (100%). The procedural success rate was 99.1%. The CTA sizing strategy accurately predicted the implant size in 93.5% of patients. Mean number of devices used was 1.10 ± 0.3. Peri-procedural complication rate was 2.2%. 6 patients were lost to follow-up. Mean follow-up was 608.94 days with a total of 377.04 patient years. Median follow-up period of 368 days (interquartile range: 209-1067 days). There were 51 deaths from all causes (13.52 per 100 patient-years), 10 cases of cerebral embolism (2.65 per 100 patient-years), 2 cases of systemic embolism (0.53 per 100 patient-years), 17 cases of major bleeding (4.50 per 100 patient-years), and 31 cases of minor bleeding (8.2 per 100 patient-years). All-cause mortality at 1, 2, and 3 years was 12.7%, 20.9%, and 29.2%, respectively. CV event rates at 1, 2, and 3 years were 2.1%, 6.6%, and 10.5%, respectively. CONCLUSIONS: CTA-based preprocedural planning is accurate in predicting device size for LAAC and associated with excellent clinical outcomes at 5 years.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Embolia , Embolia Intracraneal , Accidente Cerebrovascular , Humanos , Masculino , Femenino , Estudios de Seguimiento , Cierre del Apéndice Auricular Izquierdo , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Fibrilación Atrial/complicaciones , Angiografía por Tomografía Computarizada , Resultado del Tratamiento , Embolia Intracraneal/diagnóstico por imagen , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Apéndice Atrial/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Hemorragia , Ecocardiografía Transesofágica/efectos adversos
5.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37988439

RESUMEN

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Resultado del Tratamiento , Tomografía Computarizada por Rayos X , Diseño de Prótesis
6.
JACC Cardiovasc Interv ; 16(13): 1626-1635, 2023 07 10.
Artículo en Inglés | MEDLINE | ID: mdl-37438029

RESUMEN

BACKGROUND: The latest-generation Evolut FX TAVR system (Medtronic) offers several potential design improvements over its predecessors, but early reported experience has been limited. OBJECTIVES: This study sought to report our multicenter, limited market release, first-in-human experience of transcatheter aortic valve replacement (TAVR) with the Evolut FX system and compare it with a single-center PRO+ (Medtronic) experience. METHODS: From June 27 to September 16, 2022, 226 consecutive patients from 9 US centers underwent transfemoral TAVR with the Evolut FX system for native aortic stenosis (89.4%) or prosthetic valve degeneration (10.6%). Commissural alignment was defined as 0° to 30° between native and FX commissures. Patient, anatomical, and procedural characteristics were retrospectively reviewed, and 30-day clinical and echocardiographic outcomes per Valve Academic Research Consortium-3 definitions were reported. RESULTS: Of 226 patients, 34.1% were low risk, 4% had a bicuspid valve, and 11.5% had a horizontal root (≥60°). Direct Inline sheath (Medtronic) was used in 67.6% and Lunderquist stiff wire (Cook Medical) in 35.4% of cases. Optimal hat marker orientation during deployment was achieved in 98.4%, with commissural alignment in 96.5%. At 30 days, 14.3% mild, 0.9% moderate, and no severe paravalvular leak were observed. Compared with the Evolut PRO+ experience from 1 center, FX had a more symmetrical implantation with shallower depth at the left coronary cusp (P < 0.001), fewer device recaptures (26.1% vs 39.5%; P = 0.004), and improved commissural alignment (96.5% vs 80.2%; P < 0.001). CONCLUSIONS: The Evolut FX system demonstrated favorable 30-day outcomes with a significant improvement over PRO+ in achieving commissural alignment, fewer device recaptures, and more symmetrical implantation. These features may benefit younger patients undergoing TAVR with the supra-annular, self-expanding valve, where lifetime management would be important.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Catéteres
7.
Struct Heart ; 7(4): 100182, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37520136

RESUMEN

Background: Inflammation and thrombosis are often linked mechanistically and are associated with adverse events after transcatheter aortic valve replacement (TAVR). High residual platelet reactivity (HRPR) is especially common when clopidogrel is used in this setting, but its relevance to immune activation is unknown. We sought to determine whether residual activity at the purinergic receptor P2Y12 (P2Y12) promotes prothrombotic immune activation in the setting of TAVR. Methods: This was a randomized trial of 60 patients (enrolled July 2015 through December 2018) assigned to clopidogrel (300mg load, 75mg daily) or ticagrelor (180mg load, 90 mg twice daily) before and for 30 days following TAVR. Co-primary endpoints were P2Y12-dependent platelet activity (Platelet Reactivity Units; VerifyNow) and the proportion of inflammatory (cluster of differentiation [CD] 14+/CD16+) monocytes 1 day after TAVR. Results: Compared to clopidogrel, those randomized to ticagrelor had greater platelet inhibition (median Platelet Reactivity Unit [interquartile range]: (234 [170.0-282.3] vs. 128.5 [86.5-156.5], p < 0.001), but similar inflammatory monocyte proportions (22.2% [18.0%-30.2%] vs. 25.1% [22.1%-31.0%], p = 0.201) 1 day after TAVR. Circulating monocyte-platelet aggregates, soluble CD14 levels, interleukin 6 and 8 levels, and D-dimers were also similar across treatment groups. HRPR was observed in 63% of the clopidogrel arm and was associated with higher inflammatory monocyte proportions. Major bleeding events, pacemaker placement, and mortality did not differ by treatment assignment. Conclusions: Residual P2Y12 activity after TAVR is common in those treated with clopidogrel but ticagrelor does not significantly alter biomarkers of prothrombotic immune activation. HRPR appears to be an indicator (not a cause) of innate immune activation in this setting.

8.
Europace ; 2023 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-37143414

RESUMEN

BACKGROUND: Patients with hypertrophic cardiomyopathy (HCM) and atrial fibrillation (AF) are at increased stroke risk in comparison to those with non-valvular AF not affected by HCM. OBJECTIVES: To investigate the role of left atrial appendage closure (LAAC) in patients with HCM and AF. METHODS AND RESULTS: We identified patients with HCM and AF using the National Readmission Dataset. Patients were stratified based on LAAC status. The primary efficacy outcome was a composite of ischaemic and haemorrhagic stroke, TIA, and all-cause mortality. The primary safety outcome was a composite of major bleeding and pericardial complications. Patients were matched using inverse probability of treatment weighting. Cox-proportional hazard regression was applied to calculate the hazard ratio (HR) with a 95% confidence interval (CI) on matched cohorts. We identified 71 980 patients with HCM and AF. 1351 (1.9%) patients underwent LAAC. Two hundred and eighty-seven (21.2%) underwent transcatheter LAAC. LAAC was associated with a lower risk of the primary efficacy outcome (2.5% vs. 5.4%, HR: 0.38; 95% CI: 0.17-0.88; P = 0.024), the primary safety outcome (2.9% vs. 6.8%, HR: 0.39; 95% CI: 0.23-0.66, P = 0.001), and reduced major bleeding. The LAAC group trended towards a lower risk of ischaemic stroke and all-cause mortality. CONCLUSION: Surgical and transcatheter LAAC was associated with a lower risk of haemorrhagic stroke and major bleeding.

9.
Heart ; 109(19): 1473-1478, 2023 09 13.
Artículo en Inglés | MEDLINE | ID: mdl-37208159

RESUMEN

OBJECTIVE: The purpose of this study is to describe recent mortality trends from aortic stenosis (AS) among eight high-income countries. METHODS: We analysed the WHO mortality database to determine trends in mortality from AS in the UK, Germany, France, Italy, Japan, Australia, the USA and Canada from 2000 to 2020. Crude and age-standardised mortality rates per 100 000 persons were calculated. We calculated age-specific mortality rates in three groups (<64, 65-79 and ≥80 years). Annual percentage change was analysed using joinpoint regression. RESULTS: During the observation period, the crude mortality rates per 100 000 persons increased in all the eight countries (from 3.47 to 5.87 in the UK, from 2.98 to 8.93 in Germany, from 3.84 to 5.52 in France, from 1.97 to 4.33 in Italy, from 1.12 to 5.49 in Japan, from 2.14 to 3.38 in Australia, from 3.58 to 4.22 in the USA and from 2.12 to 5.00 in Canada). In joinpoint regression of age-standardised mortality rates, trend changes towards a decrease were observed in Germany after 2012 (-1.2%, p=0.015), Australia after 2011 (-1.9%, p=0.005) and the USA after 2014 (-3.1%, p<0.001). Age-specific mortality rates in age group ≥80 years had shifts towards decreasing trends in all the eight countries in contrast to other younger age groups. CONCLUSIONS: While crude mortality rates increased in the eight countries, shifts towards decreasing trends were identified in age-standardised mortality rates in three countries and in the elderly aged ≥80 years in the eight countries. Further multidimensional observation is warranted to clarify the mortality trends.


Asunto(s)
Estenosis de la Válvula Aórtica , Anciano , Humanos , Países Desarrollados , Italia , Alemania/epidemiología , Francia , Mortalidad
11.
Circ Cardiovasc Interv ; 16(3): e012623, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36943929

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement is approved for treatment of patients with severe aortic stenosis across the spectrum of risk. While considering broader indications for use, transcatheter aortic valve replacement in large native annuli has become increasingly important. METHODS: Patients with tricuspid aortic stenosis undergoing transcatheter aortic valve replacement using the Evolut R or Evolut PRO+ 34 mm valves (Medtronic, Minneapolis, MN) in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry between October 2016 and September 2020 were stratified according to in range (>12%) device oversizing and below range (0%-12%) device oversizing. Patients undergoing valve-in-valve procedures, having a baseline annulus size <26 or ≥34 mm, or without computed tomography angiography measured annulus size were excluded. Percentage of oversizing was calculated as [(valve diameter-annulus diameter)×100/annulus diameter]. RESULTS: Transcatheter aortic valve replacement in patients with large annuli was performed in 8017 patients with a mean (±SD) age 79.3±7.9 years and 94% were male. Below range (n=1096) was less common than in range oversizing (n=6921). At 1-year follow-up, mortality (19.6% versus 14.9%; P=0.001), aortic valve reintervention (2.1% versus 0.6%; P<0.001) and valve-related readmission rates (3.2% versus 2.0%; P=0.014) were higher in the below range device oversizing group versus in range group respectively. In a multivariable Cox proportional hazards regression model, when controlling for clinically relevant covariates, below range device oversizing was associated with higher 1-year all-cause mortality (HR, 1.28 [CI, 1.07-1.51]; P=0.005). CONCLUSIONS: Results from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry in patients with large annuli valves using 34mm Evolut R/PRO+ valves suggest that in range (>12%) device oversizing delivered better clinical outcomes than implantation with below range (0%-12%) device oversizing.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano , Anciano de 80 o más Años , Femenino , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Sistema de Registros , Diseño de Prótesis
13.
Europace ; 25(4): 1441-1450, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794441

RESUMEN

AIMS: Patients who undergo permanent pacemaker (PPM) implantation after transcatheter aortic valve replacement (TAVR) have a worse outcome. The aim of this study was to identify risk factors of worse outcomes in patients with post-TAVR PPM implantation. METHODS AND RESULTS: This is a single-centre, retrospective study of consecutive patients who underwent post-TAVR PPM implantation from 11 March 2011 to 9 November 2019. Clinical outcomes were evaluated by landmark analysis with cut-off at 1 year after the PPM implantation. Of the 1389 patients underwent TAVR during the study duration and a total of 110 patients were included in the final analysis. Right ventricular pacing burden (RVPB) ≥ 30% at 1 year was associated with a higher likelihood of heart failure (HF) readmission [adjusted hazard ratio (aHR): 6.333; 95% confidence interval [CI]: 1.417-28.311; P = 0.016] and composite endpoint of overall death and/or HF (aHR: 2.453; 95% CI: 1.040-5.786; P = 0.040). The RVPB ≥30% at 1 year was associated with higher atrial fibrillation burden (24.1 ± 40.6% vs. 1.2 ± 5.3%; P = 0.013) and a decrease in left ventricular ejection fraction (-5.0 ± 9.8% vs. + 1.1 ± 7.9%; P = 0.005). The predicting factors of the RVPB ≥30% at 1 year were the presence of RVPB ≥40% at 1 month and the valve implantation depth measured from non-coronary cusp ≥4.0 mm (aHR: 57.808; 95% CI: 12.489-267.584; P < 0.001 and aHR: 6.817; 95% CI: 1.829-25.402; P = 0.004). CONCLUSIONS: The RVPB ≥30% at 1 year was associated with worse outcomes. Clinical benefit of minimal RV pacing algorithms and biventricular pacing needs to be investigated.


Asunto(s)
Estenosis de la Válvula Aórtica , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estimulación Cardíaca Artificial/efectos adversos , Estudios Retrospectivos , Volumen Sistólico , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Función Ventricular Izquierda , Factores de Riesgo , Válvula Aórtica/cirugía
15.
Am J Cardiol ; 189: 1-10, 2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36481373

RESUMEN

Permanent pacemaker implantation (PPMI) reduction and optimal management of newly acquired conduction disturbances after transcatheter aortic valve implantation (TAVI) are crucial. We sought to evaluate the relation between transcatheter heart valve (THV) implantation depth and baseline and newly acquired conduction disturbances on PPMI after TAVI. This study included 1,026 consecutive patients with severe symptomatic aortic stenosis (mean age 79.7 ± 8.4 years; 47.4% female) who underwent TAVI with the newer-generation self-expanding THVs Primary outcomes were early and late PPMI defined as the need for PPMI during the index admission and between discharge and 30 days, respectively. Early and late PPMI was required for 115 (11.2%) and 21 patients (2.0%), respectively. Early PPMI rates decreased from 26.7% in 2015 and 2016 to 5.7% in 2021, and so did the mean THV depth from 4.4 ± 2.4 mm to 1.8 ± 1.6 mm. Receiver operator characteristics curve analyses showed THV depth had significant discriminatory value for early and late PPMI with cutoff values of 3.0 and 2.2 mm, respectively. Rates of early and late PPMI were significantly lower for patients with shallower compared with deeper implantations (5.1% vs 22.6% and 0.4% vs 4.1%, p <0.001 for both, respectively). Furthermore, rates of early PPMI were lower with shallower implantations in patients with new left bundle branch block after TAVI (2.4% vs 15.9%; p <0.001) and those with baseline right bundle branch block (7.5% vs 29.6%; p = 0.017). Lower rates of PPMI with shallower THV implantation were consistently observed, including in patients with baseline and newly acquired conduction disturbances. Our findings might help optimize the management of a temporary pacemaker after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Bloqueo de Rama/terapia
17.
Am. j. cardiol ; 15(175): 80-87, July. 2022.
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1377949

RESUMEN

ABSTRACT Previous studies reported that new-onset persistent left bundle branch block (NOP-LBBB) was related to worse outcomes after transcatheter aortic valve implantation (TAVI). However, these results can be confounded by the presence of permanent pacemaker (PPM) implantation before and after TAVI. Long-term outcomes and the risk stratification of NOP-LBBB not having PPM implantation before and after TAVI have not been fully investigated. This is an international, multicenter, retrospective study of patients who underwent TAVI from July 31, 2007, to May 8, 2020. A total of 2,240 patients were included, and 17.5% of patients developed NOP-LBBB. NOP-LBBB was associated with cardiac mortality (adjusted hazard ratio [aHR] 1.419, 95% confidence interval [CI] 1.014 to 1.985, p = 0.041) and the composite outcomes of cardiac mortality and/or heart failure readmission (aHR 1.313, 95% CI 1.027 to 1.678, p = 0.030). Patients who developed NOP-LBBB with pre-TAVI left ventricular ejection fraction (LVEF) <40% were significantly associated with cardiac mortality (aHR 2.049, 95% CI 1.039 to 4.041, p = 0.038), heart failure (aHR 3.990, 95% CI 2.362 to 6.741, p <0.001), and the composite outcome (aHR 2.729, 95% CI 1.703 to 4.374, p <0.001). Although NOP-LBBB with pre-TAVI LVEF >40% had a significant decrease in LVEF 6 to 12 months after TAVI (-1.8 ± 9.7% vs +0.6 ± 8.1%, p = 0.003), NOP-LBBB with pre-TAVI LVEF <40% had a significant increase in LVEF 6 to 12 months after TAVI (+9.7 ± 13.6% vs +13.0 ± 11.7%, p = 0.157). In conclusion, patients with NOP-LBBB without pre-TAVI and post-TAVI PPM developed significantly worse long-term outcomes, especially in patients with pre-TAVI LVEF <40%. Further prospective investigation should be undertaken.


Asunto(s)
Bloqueo de Rama , Reemplazo de la Válvula Aórtica Transcatéter , Insuficiencia Cardíaca
18.
J Am Heart Assoc ; 11(12): e024707, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35699176

RESUMEN

Background There is a concern that resheathing/repositioning of transcatheter heart valves during transcatheter aortic valve implantation (TAVI) may lead to an increased risk of periprocedural complications. We aimed to evaluate the short- and long-term impact on clinical outcomes of resheathing for repositioning of transcatheter heart valves during TAVI procedures. Methods and Results We conducted a systematic search of Embase, MEDLINE, and Cochrane Central Register of Controlled Trials databases to identify studies comparing outcomes between patients requiring resheathing/repositioning during TAVI and those who did not. Random-effects meta-analyses were used to estimate the association of resheathing compared with no resheathing with clinical outcomes after TAVI. Seven studies including 4501 participants (pooled mean age, 80.9±7.4 years; 54% women; and 1374 [30.5%] patients requiring resheathing/repositioning) were included in this study. No significant differences between the 2 groups were identified with regards to safety: 30-day mortality (n=3125; odds ratio [OR], 0.74 [95% confidence interval [CI], 0.41-1.33]; I2=0%), stroke (n=4121; OR, 1.09 [95% CI, 0.74-1.62]; I2=0%), coronary obstruction (n=3000; OR, 2.35 [95% CI, 0.17-33.47]; I2=75%), major vascular complications (n=3125; OR, 0.92 [95% CI, 0.66-1.33]; I2=0%), major bleeding (n=3125; OR, 1.13 [95% CI, 0.94-2.01]; I2=39%), acute kidney injury (n=3495; OR, 1.30 [95% CI, 0.64-2.62]; I2=44%), and efficacy outcomes: device success (n=1196; OR, 0.77 [95% CI, 0.51-1.14]; I2=0%), need for a second valve (n=3170; OR, 2.86 [95% CI, 0.96-8.48]; I2=62%), significant (moderate or higher) paravalvular leak (n=1151; OR, 1.53 [95% CI, 0.83-2.80]; I2=0%), and permanent pacemaker implantation (n=1908; OR, 1.04 [95% CI, 0.68-1.57]; I2=58%). One-year mortality was similar between groups (n=1972; OR, 1.00 [95% CI, 0.68-1.47]; I2=0%). Conclusions Resheathing of transcatheter heart valves during TAVI is associated with similar periprocedural risk compared with no resheathing in several patient-important outcomes. These data support the safety of current self-expanding transcatheter heart valves with resheathing features. Registration URL: https://www.crd.york.ac.uk/prospero/; Unique identifier: CRD42021273715.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
19.
Am J Cardiol ; 175: 80-87, 2022 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-35597627

RESUMEN

Previous studies reported that new-onset persistent left bundle branch block (NOP-LBBB) was related to worse outcomes after transcatheter aortic valve implantation (TAVI). However, these results can be confounded by the presence of permanent pacemaker (PPM) implantation before and after TAVI. Long-term outcomes and the risk stratification of NOP-LBBB not having PPM implantation before and after TAVI have not been fully investigated. This is an international, multicenter, retrospective study of patients who underwent TAVI from July 31, 2007, to May 8, 2020. A total of 2,240 patients were included, and 17.5% of patients developed NOP-LBBB. NOP-LBBB was associated with cardiac mortality (adjusted hazard ratio [aHR] 1.419, 95% confidence interval [CI] 1.014 to 1.985, p = 0.041) and the composite outcomes of cardiac mortality and/or heart failure readmission (aHR 1.313, 95% CI 1.027 to 1.678, p = 0.030). Patients who developed NOP-LBBB with pre-TAVI left ventricular ejection fraction (LVEF) <40% were significantly associated with cardiac mortality (aHR 2.049, 95% CI 1.039 to 4.041, p = 0.038), heart failure (aHR 3.990, 95% CI 2.362 to 6.741, p <0.001), and the composite outcome (aHR 2.729, 95% CI 1.703 to 4.374, p <0.001). Although NOP-LBBB with pre-TAVI LVEF >40% had a significant decrease in LVEF 6 to 12 months after TAVI (-1.8 ± 9.7% vs +0.6 ± 8.1%, p = 0.003), NOP-LBBB with pre-TAVI LVEF <40% had a significant increase in LVEF 6 to 12 months after TAVI (+9.7 ± 13.6% vs +13.0 ± 11.7%, p = 0.157). In conclusion, patients with NOP-LBBB without pre-TAVI and post-TAVI PPM developed significantly worse long-term outcomes, especially in patients with pre-TAVI LVEF <40%. Further prospective investigation should be undertaken.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Bloqueo de Rama/epidemiología , Bloqueo de Rama/etiología , Bloqueo de Rama/terapia , Insuficiencia Cardíaca/epidemiología , Humanos , Estudios Retrospectivos , Medición de Riesgo/métodos , Volumen Sistólico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Función Ventricular Izquierda
20.
Int J Cardiol Heart Vasc ; 40: 101008, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35330979

RESUMEN

Background: Though the co-prevalence of aortic stenosis (AS) and cardiac amyloidosis (CA) is increasingly recognized, the role of transcatheter aortic valve replacement (TAVR) in patients with CA remains unclear. Methods: The National Readmission Dataset (2016-18) and ICD-10 codes were used to identify those with CA and AS, in conjunction with TAVR status. The primary outcome was a composite of heart failure (HF) readmissions and all-cause mortality. All outcomes were followed up to 1-year with a median follow up time 172-days. Kaplan-Meier curves and multivariate cox-proportional hazard regression were used for time-to-event analysis. Results: Of 1,127 CA patients, 92 (8.2%) had undergone TAVR. Patients with CA who received TAVR were younger and more commonly had coronary artery disease (67.3% vs 44.2%). Teaching (93.6% vs 81.1%) and large hospitals (77.7% vs 59.3%) performed more TAVRs. In multivariate analysis, TAVR was associated with an improved primary outcome (8.9% vs 24.4%, HR:0.32; 95% CI 0.14-0.71, p = 0.007) and with reduced HF readmissions (3.8% vs 19.4%, HR:0.22; 95% CI 0.07-0.68, p = 0.008). All-cause mortality was numerically lower in TAVR patients with CA but did not reach statistical significance. Conclusions: CA patients who receive TAVR are younger, and the procedure is more commonly performed at large, teaching hospitals. TAVR was associated with a lower primary composite outcome of HF readmissions and all-cause mortality.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...