Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 45(5): 612-618, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35383979

RESUMEN

BACKGROUND: Although radiofrequency (RF) catheter ablation of cavo-tricuspid isthmus (CTI) is an established treatment for typical right atrial flutter (RAFL), it remains to be established whether local tissue impedance (LI) is able to predict effective CTI ablation and what LI drop values during ablation should be used to judge a lesion as effective. We aimed to investigate the ability of LI to predict ablation efficacy in patients with RAFL. METHODS: RF delivery was guided by the DirectSense™ algorithm. Successful single RF application was defined according to a defragmentation of atrial potentials (DAP), reduction of voltage (RedV) by at least 80% or changes on unipolar electrogram (UPC). The ablation endpoint was the creation of bidirectional conduction block (BDB) across the isthmus. RESULTS: 392 point-by-point RF applications were analyzed in 48 consecutive RAFL patients. The mean baseline LI was 105.4 ± 12Ω prior to ablation and 92.0 ± 11Ω after ablation (p < 0.0001). According to validation criteria, absolute drops in impedance were larger at successful ablation sites than at ineffective ablation sites (DAP: 17.8 ± 6Ω vs. 8.7 ± 4Ω; RedV: 17.2 ± 6Ω vs. 7.8 ± 5Ω; UPC: 19.6 ± 6Ω vs. 10.1 ± 5Ω, all p < 0.0001). LI drop values significantly increased according to the number of criteria satisfied (ranging from 7.5Ω to 19.9). BDB was obtained in all cases. No procedure-related adverse events were reported. CONCLUSIONS: A LI-guided approach to CTI ablation was safe and effective in treating RAFL. The magnitude of LI drop was associated with effective lesion formation and BDB and could be used as a marker of ablation efficacy. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Ablación por Catéter/efectos adversos , Impedancia Eléctrica , Bloqueo Cardíaco/etiología , Humanos , Resultado del Tratamiento
2.
Clin Case Rep ; 9(8): e04477, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34457275

RESUMEN

Permanent His bundle pacing is a physiological alternative to right ventricular pacing, resulting in a lower probability of pacing-induced cardiomyopathy and left ventricular ejection fraction deterioration. The combined use of UHD mapping systems allows precise and detailed information on the His bundle location, possibly providing more pacing option locations.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...