1.
Eur J Pediatr ; 183(2): 815-825, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38017338

RESUMEN

Foreign body aspiration (FBA) is a common cause of pediatric morbidity, but a standardized protocol to guide decision-making about bronchoscopy is lacking. We aimed to validate a new Foreign body aspiration score (FOBAS) for the pediatric emergency department (ED). Patients aged 0-18 years referred to the ED for suspected FBA were prospectively enrolled. FOBAS was calculated according to clinical features of a choking episode, sudden cough, exposure to nuts, absence of fever and rhinitis, stridor, and unilateral auscultatory and radiological findings. FBA risk was evaluated based on the total score (low, 1-3; moderate, 4-6; high, 7-10). Low-risk children were discharged from the ED and followed clinically. Moderate-risk children were hospitalized and evaluated by a pediatric pulmonologist, and high-risk children were referred directly for therapeutic bronchoscopy. Among the 100 enrolled children (59% males; median age 20 [interquartile range 11-39] months), a foreign body was diagnosed in 1/49 (2%), 14/41 (34.1%), and 9/10 (90%) with low, moderate, and high FOBAS, respectively (P < .001). Logistic regression indicated a higher risk for FBA with higher scores. The odds ratio for each additional point was 2.75 (95% confidence interval 1.78-4.24), and FOBAS showed a high predictive value for FBA (area under the curve 0.89). FOBAS implementation significantly reduced the rate of negative bronchoscopies, from 67.4% annually during 2016-2019 to 50% in 2020 (P = .042). CONCLUSION: FOBAS reliably predicts FBA in cases of suspected FBA and improves management and in-hospital decision-making. WHAT IS KNOWN: • Foreign body aspiration is a major cause of pediatric morbidity and mortality. • Currently, there is no unified protocol for children referred to the emergency department for suspected FBA, therefore, a well-defined algorithm is needed to improve the decision-making process. WHAT IS NEW: • The pediatric Foreign body aspiration score (FOBAS) is a new, prospectively validated clinical score that shows high sensitivity and specificity for the presence of FBA in children. • FOBAS reduces unnecessary admissions and invasive procedures and leads to better clinical outcomes.


Asunto(s)
Obstrucción de las Vías Aéreas , Cuerpos Extraños , Masculino , Niño , Humanos , Lactante , Preescolar , Femenino , Estudios Retrospectivos , Aspiración Respiratoria/diagnóstico , Aspiración Respiratoria/etiología , Aspiración Respiratoria/terapia , Broncoscopía/efectos adversos , Broncoscopía/métodos , Obstrucción de las Vías Aéreas/diagnóstico , Obstrucción de las Vías Aéreas/etiología , Obstrucción de las Vías Aéreas/terapia , Algoritmos , Cuerpos Extraños/diagnóstico , Cuerpos Extraños/terapia , Cuerpos Extraños/complicaciones
2.
Circ Cardiovasc Imaging ; 16(11): e015569, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37955139

RESUMEN

BACKGROUND: We aimed to assess in a prospective multicenter study the quality of echocardiographic exams performed by inexperienced users guided by a new artificial intelligence software and evaluate their suitability for diagnostic interpretation of basic cardiac pathology and quantitative analysis of cardiac chamber and function. METHODS: The software (UltraSight, Ltd) was embedded into a handheld imaging device (Lumify; Philips). Six nurses and 3 medical residents, who underwent minimal training, scanned 240 patients (61±16 years; 63% with cardiac pathology) in 10 standard views. All patients were also scanned by expert sonographers using the same device without artificial intelligence guidance. Studies were reviewed by 5 certified echocardiographers blinded to the imager's identity, who evaluated the ability to assess left and right ventricular size and function, pericardial effusion, valve morphology, and left atrial and inferior vena cava sizes. Finally, apical 4-chamber images of adequate quality, acquired by novices and sonographers in 100 patients, were analyzed to measure left ventricular volumes, ejection fraction, and global longitudinal strain by an expert reader using conventional methodology. Measurements were compared between novices' and experts' images. RESULTS: Of the 240 studies acquired by novices, 99.2%, 99.6%, 92.9%, and 100% had sufficient quality to assess left ventricular size and function, right ventricular size, and pericardial effusion, respectively. Valve morphology, right ventricular function, and left atrial and inferior vena cava size were visualized in 67% to 98% exams. Images obtained by novices and sonographers yielded concordant diagnostic interpretation in 83% to 96% studies. Quantitative analysis was feasible in 83% images acquired by novices and resulted in high correlations (r≥0.74) and small biases, compared with those obtained by sonographers. CONCLUSIONS: After minimal training with the real-time guidance software, novice users can acquire images of diagnostic quality approaching that of expert sonographers in most patients. This technology may increase adoption and improve accuracy of point-of-care cardiac ultrasound.


Asunto(s)
Fibrilación Atrial , Derrame Pericárdico , Humanos , Inteligencia Artificial , Volumen Sistólico , Derrame Pericárdico/diagnóstico por imagen , Estudios Prospectivos , Ecocardiografía/métodos
3.
Eur J Pediatr ; 182(9): 4205-4212, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37450025

RESUMEN

Foreign Body Aspiration (FBA) is a common medical emergency among young children, but the evaluation and management of a suspected FBA case can vary across physicians and centers. We aimed to identify which clinical, laboratory, and radiological findings can predict FBA in children and to evaluate a clinical score to improve FBA prediction. This is a retrospective cohort study of patients aged 0-18 years admitted to Soroka University Medical Center between 2010 and 2020 with suspected FBA. All patients underwent flexible bronchoscopy and were divided into positive and negative FBA groups. A newly developed foreign body aspiration score (FOBAS), based on medical history, physical examination, and chest X-ray findings, was evaluated for its predictability. The study included 412 children (median age 21 months, 56.8% females), of whom 154 (37.4%) had FBA and 258 (62.6%) did not. Multivariate regression analysis showed exposure to nuts/seeds, unilateral wheezing or decreased breath sounds, stridor, and suggestive findings on chest X-ray were significant risk factors for FBA (OR [95%CI] -1.994[1.290-3.082], 1.487[1.206-1.832], 1.883 [1.011-3.509] and 2.386[1.917-2.970], respectively). However, a choking episode, acute cough, and absence of fever and rhinorrhea did not predict FBA. FOBAS showed an increased risk of FBA for each additional point of the score, with an odds ratio of 1.572 (95% CI-1.389-1.799).  Conclusion: FOBAS is a good predictor for the presence of FBA in children. Once prospectively validated, FOBAS could aid in decision-making at the emergency department, enabling more standardized care, reducing unnecessary procedures, and leading to better clinical outcomes. What is Known: • The evaluation and management of a child with suspected foreign body aspiration (FBA) vary across physicians and centers, without a consensus regarding the indications and criteria for performing bronchoscopy. • Flexible bronchoscopy is the standard procedure for the diagnosis and sometimes treatment of FBA in children, but it may hold potential complications. What is New: • We propose a newly developed foreign body aspiration score (FOBAS), based on medical history, physical examination, and chest X-ray findings, for the prediction of FBA in children at the emergency department. • The FOBAS is a good predictor of FBA in children. The score enables more standardized care and may reduce unnecessary procedures.


Asunto(s)
Cuerpos Extraños , Femenino , Niño , Humanos , Lactante , Preescolar , Masculino , Estudios Retrospectivos , Cuerpos Extraños/diagnóstico , Cuerpos Extraños/complicaciones , Broncoscopía/efectos adversos , Broncoscopía/métodos , Radiografía , Tos/etiología , Ruidos Respiratorios/etiología
5.
Eur J Pediatr ; 182(7): 3101-3109, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37081195

RESUMEN

Chest X-ray (CXR) is an important tool in the assessment of children with suspected foreign body aspiration (FBA), although it can falsely be interpreted as normal in one-third of the cases. The aim of this study is to evaluate the positive predictive value of CXR in children hospitalized with suspected FBA, when interpreted by three disciplines: pediatric pulmonology, pediatric radiology, and pediatric residents. This is a retrospective study that included children aged 0-18 years, admitted with suspected FBA, between 2009 and 2020 in one tertiary center. All patients underwent CXR and a flexible/rigid bronchoscopy for the definitive diagnosis of FBA, up to 1 week apart. Two physicians from each discipline interpreted the CXR, independently. Intra-raters' and inter-raters' agreements were assessed. Sensitivity, specificity, and area under the curve (AUC) were calculated for each discipline. Four hundred seventy-three children were included in the study, 175 (37%) with FBA and 298 (63%) without FBA on flexible/rigid bronchoscopy. The most common radiological findings, as interpreted by a pediatric pulmonologist, were unilateral hyperinflation (47%), radiopaque FB (37.6%), lobar atelectasis (10.3%), unilateral hyperinflation with atelectasis (3.4%), and lobar consolidation (1.7%). Intra-raters' agreement ranged from 0.744 (p < 0.001) among pediatric pulmonologists to 0.326 (p < 0.001) among pediatric radiologists. AUC for predicting FBA based on a CXR was 0.81, 0.77, and 0.7 when interpreted by pediatric pulmonologists, pediatric residents, and radiologists, respectively (p < 0.001). CONCLUSIONS: CXR has a high positive predictive value and independently predicts FBA in children; however, normal CXR should not rule out FBA. Predictability is variable among different disciplines. WHAT IS KNOWN: • Chest X-ray is an important tool in the assessment of children with suspected foreign body aspiration (FBA). • Chest X-ray can be interpreted as normal in one-third of the cases. WHAT IS NEW: • Chest X-ray independently predicts FBA in children, with a high positive predictive value. • The ability of chest x-ray to predict FBA in children differs between pediatric residents, pediatric radiologists, and pediatric pulmonologists.


Asunto(s)
Cuerpos Extraños , Atelectasia Pulmonar , Niño , Humanos , Lactante , Estudios Retrospectivos , Neumólogos , Rayos X , Broncoscopía , Cuerpos Extraños/diagnóstico por imagen , Radiólogos