Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Acute Med Surg ; 11(1): e954, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38655507

RESUMEN

Background: Factor Xa inhibitors are direct oral anticoagulants that are extremely useful in clinical applications, safe, and do not require dose adjustment. It is desirable to be able to monitor their effects in the event of hemorrhagic complications requiring neutralization. However, it is difficult to monitor their activity and neutralization using conventional coagulation tests. Case Presentation: We report three patients taking factor Xa inhibitors who underwent rotational thromboelastography (ROTEM) monitoring before and after neutralization with andexanet alfa. All three patients had hemorrhagic complications that required neutralization of their factor Xa inhibitors using andexanet alfa. One ROTEM parameter, the EXTEM clotting time (EXTEM-CT), was immediately shortened after andexanet alfa bolus administration, without subsequent extension of the EXTEM-CT assessed 4 h after the bolus dose. Conclusion: ROTEM parameters, particularly EXTEM-CT, might be useful for monitoring neutralization of factor Xa inhibitors.

2.
J Toxicol Sci ; 48(12): 641-644, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38044125

RESUMEN

Guanfacine hydrochloride extended-release (GXR) is used to treat attention deficit hyperactivity disorder. It is a selective α2A-adrenorecepor agonist that was reported to cause QT prolongation and hypotension in the event of overdosing. We report the case of a 17-year-old man who took 226 tablets of GXR 3 mg for attempted suicide. He was found complaining of dyspnea, and emergency medical services were called. When the patient was transferred to our hospital, his Glasgow coma scale was 12 (E4V3M5). He was agitated and hypoxemic. He was intubated for invasive mechanical ventilation under sedation. His chest X-ray and computed tomography scan showed pulmonary edema. Transthoracic echocardiography showed markedly reduced cardiac function. His serum guanfacine concentration peaked on day 3 after admission. His pulmonary edema improved quickly after a decrease in serum guanfacine concentration, but cardiac decompensation persisted for about 1 month. This case reveals that the decline in cardiac function after guanfacine intoxication is prolonged even after its serum concentration has decreased.


Asunto(s)
Guanfacina , Edema Pulmonar , Adolescente , Humanos , Masculino , Agonistas de Receptores Adrenérgicos alfa 2/efectos adversos , Trastorno por Déficit de Atención con Hiperactividad/tratamiento farmacológico , Preparaciones de Acción Retardada/efectos adversos , Guanfacina/sangre , Guanfacina/toxicidad , Edema Pulmonar/inducido químicamente
3.
Intern Med ; 62(5): 717-722, 2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36543214

RESUMEN

Objectives Coronavirus disease 2019 (COVID-19) reportedly causes thromboembolic complications due to coagulopathy with hypercoagulability and a hypofibrinolytic state. We evaluated the time-course of coagulopathy in patients with severe COVID-19 from admission to discharge from our intensive-care unit (ICU). Methods We conducted a retrospective study of adults with severe COVID-19 admitted to our ICU between January 20, 2021, and March 31, 2022. We obtained clinical information, laboratory data, and rotational thromboelastometry (ROTEM) parameters at admission and discharge. Results Fifteen patients were included. Fibrinogen and D-dimer values did not change significantly but were above the normal ranges at admission and discharge. Regarding ROTEM parameters, the maximum clot firmness in fibrinogen function (FIBTEM), a marker of hypercoagulability, did not change significantly but was above the normal range at admission and discharge [median (interquartile range), admission vs. discharge: 31 (25-34) mm vs. 31 (27-32) mm, p=0.589]. The maximum lysis at 60 minutes in the extrinsic coagulation pathway (EXTEM) and intrinsic coagulation pathway (INTEM), as markers of the fibrinolytic function, were both significantly lower at discharge than at admission [median (interquartile range), admission vs. discharge: EXTEM, 3 (2-4) vs. 1 (0-2), p=0.011; INTEM, 3 (1-6) vs. 1 (0-2), p=0.008]. Conclusion This study revealed a persistent hypercoagulable state at ICU discharge and a worse hypofibrinolytic state at discharge than at admission. These results may contribute to a better understanding of coagulopathies in the acute to subacute phases of severe COVID-19.


Asunto(s)
Trastornos de la Coagulación Sanguínea , COVID-19 , Trombofilia , Adulto , Humanos , Tromboelastografía/métodos , Estudios Retrospectivos , Pruebas de Coagulación Sanguínea , Fibrinógeno
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...