Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-36465979

RESUMEN

Lung nodule tracking assessment relies on cross-sectional measurements of the largest lesion profile depicted in initial and follow-up computed tomography (CT) images. However, apparent changes in nodule size assessed via simple image-based measurements may also be compromised by the effect of the background lung tissue deformation on the GGN between the initial and follow-up images, leading to erroneous conclusions about nodule changes due to disease. To compensate for the lung deformation and enable consistent nodule tracking, here we propose a feature-based affine registration method and study its performance vis-a-vis several other registration methods. We implement and test each registration method using both a lung- and a lesion-centered region of interest on ten patient CT datasets featuring twelve nodules, including both benign and malignant GGO lesions containing pure GGNs, part-solid, or solid nodules. We evaluate each registration method according to the target registration error (TRE) computed across 30 - 50 homologous fiducial landmarks surrounding the lesions and selected by expert radiologists in both the initial and follow-up patient CT images. Our results show that the proposed feature-based affine lesion-centered registration yielded a 1.1 ± 1.2 mm TRE, while a Symmetric Normalization deformable registration yielded a 1.2 ± 1.2 mm TRE, and a least-square fit registration of the 30-50 validation fiducial landmark set yielded a 1.5 ± 1.2 mm TRE. Although the deformable registration yielded a slightly higher registration accuracy than the feature-based affine registration, it is significantly more computationally efficient, eliminates the need for ambiguous segmentation of GGNs featuring ill-defined borders, and reduces the susceptibility of artificial deformations introduced by the deformable registration, which may lead to increased similarity between the registered initial and follow-up images, over-compensating for the background lung tissue deformation, and, in turn, compromising the true disease-induced nodule change assessment. We also assessed the registration qualitatively, by visual inspection of the subtraction images, and conducted a pilot pre-clinical study that showed the proposed feature-based lesion-centered affine registration effectively compensates for the background lung tissue deformation between the initial and follow-up images and also serves as a reliable baseline registration method prior to assessing lung nodule changes due to disease.

2.
IEEE Trans Med Imaging ; 40(12): 3424-3435, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34086563

RESUMEN

Perfusion imaging is of great clinical importance and is used to assess a wide range of diseases including strokes and brain tumors. Commonly used approaches for the quantitative analysis of perfusion images are based on measuring the effect of a contrast agent moving through blood vessels and into tissue. Contrast-agent free approaches, for example, based on intravoxel incoherent motion and arterial spin labeling, also exist, but are so far not routinely used clinically. Existing contrast-agent-dependent methods typically rely on the estimation of the arterial input function (AIF) to approximately model tissue perfusion. These approaches neglect spatial dependencies. Further, as reliably estimating the AIF is non-trivial, different AIF estimates may lead to different perfusion measures. In this work we therefore propose PIANO, an approach that provides additional insights into the perfusion process. PIANO estimates the velocity and diffusion fields of an advection-diffusion model best explaining the contrast dynamics without using an AIF. PIANO accounts for spatial dependencies and neither requires estimating the AIF nor relies on a particular contrast agent bolus shape. Specifically, we propose a convenient parameterization of the estimation problem, a numerical estimation approach, and extensively evaluate PIANO. Simulation experiments show the robustness and effectiveness of PIANO, along with its ability to distinguish between advection and diffusion. We further apply PIANO on a public brain magnetic resonance (MR) perfusion dataset of acute stroke patients, and demonstrate that PIANO can successfully resolve velocity and diffusion field ambiguities and results in sensitive measures for the assessment of stroke, comparing favorably to conventional measures of perfusion.


Asunto(s)
Imagen por Resonancia Magnética , Accidente Cerebrovascular , Imagen de Difusión por Resonancia Magnética , Humanos , Perfusión , Imagen de Perfusión , Marcadores de Spin , Accidente Cerebrovascular/diagnóstico por imagen
3.
IEEE Trans Biomed Eng ; 67(11): 3234-3241, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32167884

RESUMEN

OBJECTIVE: Integrate tracked ultrasound and AI methods to provide a safer and more accessible alternative to X-ray for scoliosis measurement. We propose automatic ultrasound segmentation for 3-dimensional spine visualization and scoliosis measurement to address difficulties in using ultrasound for spine imaging. METHODS: We trained a convolutional neural network for spine segmentation on ultrasound scans using data from eight healthy adult volunteers. We tested the trained network on eight pediatric patients. We evaluated image segmentation and 3-dimensional volume reconstruction for scoliosis measurement. RESULTS: As expected, fuzzy segmentation metrics reduced when trained networks were translated from healthy volunteers to patients. Recall decreased from 0.72 to 0.64 (8.2% decrease), and precision from 0.31 to 0.27 (3.7% decrease). However, after finding optimal thresholds for prediction maps, binary segmentation metrics performed better on patient data. Recall decreased from 0.98 to 0.97 (1.6% decrease), and precision from 0.10 to 0.06 (4.5% decrease). Segmentation prediction maps were reconstructed to 3-dimensional volumes and scoliosis was measured in all patients. Measurement in these reconstructions took less than 1 minute and had a maximum error of 2.2° compared to X-ray. CONCLUSION: automatic spine segmentation makes scoliosis measurement both efficient and accurate in tracked ultrasound scans. SIGNIFICANCE: Automatic segmentation may overcome the limitations of tracked ultrasound that so far prevented its use as an alternative of X-ray in scoliosis measurement.


Asunto(s)
Escoliosis , Niño , Humanos , Imagenología Tridimensional , Redes Neurales de la Computación , Escoliosis/diagnóstico por imagen , Columna Vertebral/diagnóstico por imagen , Ultrasonografía
4.
IEEE Trans Biomed Eng ; 66(1): 72-79, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-29993406

RESUMEN

OBJECTIVE: Ultrasound is an effective tool for rapid noninvasive assessment of cardiac structure and function. Determining the cardiorespiratory phases of each frame in the ultrasound video and capturing the cardiac function at a much higher temporal resolution are essential in many applications. Fulfilling these requirements is particularly challenging in preclinical studies involving small animals with high cardiorespiratory rates, requiring cumbersome and expensive specialized hardware. METHODS: We present a novel method for the retrospective estimation of cardiorespiratory phases directly from the ultrasound videos. It transforms the videos into a univariate time series preserving the evidence of periodic cardiorespiratory motion, decouples the signatures of cardiorespiratory motion with a trend extraction technique, and estimates the cardiorespiratory phases using a Hilbert transform approach. We also present a robust nonparametric regression technique for respiratory gating and a novel kernel-regression model for reconstructing images at any cardiac phase facilitating temporal superresolution. RESULTS: We validated our methods using two-dimensional echocardiography videos and electrocardiogram (ECG) recordings of six mice. Our cardiac phase estimation method provides accurate phase estimates with a mean-phase-error range of 3%-6% against ECG derived phase and outperforms three previously published methods in locating ECGs R-wave peak frames with a mean-frame-error range of 0.73-1.36. Our kernel-regression model accurately reconstructs images at any cardiac phase with a mean-normalized-correlation range of 0.81-0.85 over 50 leave-one-out-cross-validation rounds. CONCLUSION AND SIGNIFICANCE: Our methods can enable tracking of cardiorespiratory phases without additional hardware and reconstruction of respiration-free single cardiac-cycle videos at a much higher temporal resolution.


Asunto(s)
Ecocardiografía/métodos , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Animales , Corazón/fisiología , Ratones , Grabación en Video
5.
Rev Sci Instrum ; 89(7): 075107, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30068108

RESUMEN

Noninvasive in vivo imaging technologies enable researchers and clinicians to detect the presence of disease and longitudinally study its progression. By revealing anatomical, functional, or molecular changes, imaging tools can provide a near real-time assessment of important biological events. At the preclinical research level, imaging plays an important role by allowing disease mechanisms and potential therapies to be evaluated noninvasively. Because functional and molecular changes often precede gross anatomical changes, there has been a significant amount of research exploring the ability of different imaging modalities to track these aspects of various diseases. Herein, we present a novel robotic preclinical contrast-enhanced ultrasound system and demonstrate its use in evaluating tumors in a rodent model. By leveraging recent advances in ultrasound, this system favorably compares with other modalities, as it can perform anatomical, functional, and molecular imaging and is cost-effective, portable, and high throughput, without using ionizing radiation. Furthermore, this system circumvents many of the limitations of conventional preclinical ultrasound systems, including a limited field-of-view, low throughput, and large user variability.


Asunto(s)
Imagenología Tridimensional/instrumentación , Roedores , Ultrasonografía/instrumentación , Animales , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/fisiopatología , Línea Celular Tumoral , Medios de Contraste , Progresión de la Enfermedad , Diseño de Equipo , Femenino , Hemangiosarcoma/diagnóstico por imagen , Hemangiosarcoma/fisiopatología , Humanos , Estudios Longitudinales , Microburbujas , Trasplante de Neoplasias , Variaciones Dependientes del Observador , Proyectos Piloto , Reproducibilidad de los Resultados , Robótica , Programas Informáticos
6.
Ultrasound Med Biol ; 41(7): 1896-904, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25858001

RESUMEN

The recent design of ultra-broadband, multifrequency ultrasound transducers has enabled high-sensitivity, high-resolution contrast imaging, with very efficient suppression of tissue background using a technique called acoustic angiography. Here we perform the first application of acoustic angiography to evolving tumors in mice predisposed to develop mammary carcinoma, with the intent of visualizing and quantifying angiogenesis progression associated with tumor growth. Metrics compared include vascular density and two measures of vessel tortuosity quantified from segmentations of vessels traversing and surrounding 24 tumors and abdominal vessels from control mice. Quantitative morphologic analysis of tumor vessels revealed significantly increased vascular tortuosity abnormalities associated with tumor growth, with the distance metric elevated approximately 14% and the sum of angles metric increased 60% in tumor vessels versus controls. Future applications of this imaging approach may provide clinicians with a new tool in tumor detection, differentiation or evaluation, though with limited depth of penetration using the current configuration.


Asunto(s)
Neoplasias de la Mama/irrigación sanguínea , Neoplasias de la Mama/patología , Diagnóstico por Imagen de Elasticidad/métodos , Interpretación de Imagen Asistida por Computador/métodos , Microvasos/diagnóstico por imagen , Neovascularización Patológica/patología , Algoritmos , Angiografía/métodos , Animales , Neoplasias de la Mama/complicaciones , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Ratones , Neovascularización Patológica/complicaciones , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Biomaterials ; 34(37): 9341-51, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24011714

RESUMEN

A method of 3D functional ultrasound imaging has been developed to enable non-destructive assessment of extracellular matrix scaffolds that have been prepared by decellularization protocols and are intended for recellularization to create organoids. A major challenge in organ decellularization is retaining patent micro-vascular structures crucial for nutrient access and functionality of organoids. The imaging method described here provides statistical distributions of flow rates throughout the tissue volumes, 3D vessel network architecture visualization, characterization of microvessel volumes and sizes, and delineation of matrix from vascular circuits. The imaging protocol was tested on matrix scaffolds that are tissue-specific, but not species-specific, matrix extracts, prepared by a process that preserved >98% of the collagens, collagen-associated matrix components, and matrix-bound growth factors and cytokines. Image-derived data are discussed with respect to assessment of scaffolds followed by proof-of-concept studies in organoid establishment using Hep3B, a human hepatoblast-like cell line. Histology showed that the cells attached to scaffolds with patent vasculature within minutes, achieved engraftment at near 100%, expressed liver-specific functions within 24 h, and yielded evidence of proliferation and increasing differentiation of cells throughout the two weeks of culture studies. This imaging method should prove valuable in analyses of such matrix scaffolds.


Asunto(s)
Matriz Extracelular/diagnóstico por imagen , Hígado/diagnóstico por imagen , Organoides/citología , Andamios del Tejido/química , Animales , Línea Celular , Matriz Extracelular/química , Matriz Extracelular/ultraestructura , Humanos , Hígado/citología , Hígado/ultraestructura , Ratas , Ratas Wistar , Ultrasonografía
8.
IEEE Trans Med Imaging ; 32(11): 2114-26, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23899632

RESUMEN

We propose a deformable image registration algorithm that uses anisotropic smoothing for regularization to find correspondences between images of sliding organs. In particular, we apply the method for respiratory motion estimation in longitudinal thoracic and abdominal computed tomography scans. The algorithm uses locally adaptive diffusion tensors to determine the direction and magnitude with which to smooth the components of the displacement field that are normal and tangential to an expected sliding boundary. Validation was performed using synthetic, phantom, and 14 clinical datasets, including the publicly available DIR-Lab dataset. We show that motion discontinuities caused by sliding can be effectively recovered, unlike conventional regularizations that enforce globally smooth motion. In the clinical datasets, target registration error showed improved accuracy for lung landmarks compared to the diffusive regularization. We also present a generalization of our algorithm to other sliding geometries, including sliding tubes (e.g., needles sliding through tissue, or contrast agent flowing through a vessel). Potential clinical applications of this method include longitudinal change detection and radiotherapy for lung or abdominal tumours, especially those near the chest or abdominal wall.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Radiografía Abdominal/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Bases de Datos Factuales , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Mecánica Respiratoria/fisiología
9.
Proc SPIE Int Soc Opt Eng ; 8672: 86720V, 2013 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-24465118

RESUMEN

The skull of young children is made up of bony plates that enable growth. Craniosynostosis is a birth defect that causes one or more sutures on an infant's skull to close prematurely. Corrective surgery focuses on cranial and orbital rim shaping to return the skull to a more normal shape. Functional problems caused by craniosynostosis such as speech and motor delay can improve after surgical correction, but a post-surgical analysis of brain development in comparison with age-matched healthy controls is necessary to assess surgical outcome. Full brain segmentations obtained from pre- and post-operative computed tomography (CT) scans of 8 patients with single suture sagittal (n=5) and metopic (n=3), non-syndromic craniosynostosis from 41 to 452 days-of-age were included in this study. Age-matched controls obtained via 4D acceleration-based regression of a cohort of 402 full brain segmentations from healthy controls magnetic resonance images (MRI) were also used for comparison (ages 38 to 825 days). 3D point-based models of patient and control cohorts were obtained using SPHARM-PDM shape analysis tool. From a full dataset of regressed shapes, 240 healthy regressed shapes between 30 and 588 days-of-age (time step = 2.34 days) were selected. Volumes and shape metrics were obtained for craniosynostosis and healthy age-matched subjects. Volumes and shape metrics in single suture craniosynostosis patients were larger than age-matched controls for pre- and post-surgery. The use of 3D shape and volumetric measurements show that brain growth is not normal in patients with single suture craniosynostosis.

10.
Radiology ; 264(3): 733-40, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22771882

RESUMEN

PURPOSE: To determine if the morphologies of microvessels could be extracted from contrast material-enhanced acoustic angiographic ultrasonographic (US) images and used as a quantitative basis for distinguishing healthy from diseased tissue. MATERIALS AND METHODS: All studies were institutional animal care and use committee approved. Three-dimensional contrast-enhanced acoustic angiographic images were acquired in both healthy (n = 7) and tumor-bearing (n = 10) rats. High-spatial-resolution and high signal-to-noise acquisition was enabled by using a prototype dual-frequency US transducer (transmit at 4 MHz, receive at 30 MHz). A segmentation algorithm was utilized to extract microvessel structure from image data, and the distance metric (DM) and the sum of angles metric (SOAM), designed to distinguish different types of tortuosity, were applied to image data. The vessel populations extracted from tumor-bearing tissue volumes were compared against vessels extracted from tissue volumes in the same anatomic location within healthy control animals by using the two-sided Student t test. RESULTS: Metrics of microvascular tortuosity were significantly higher in the tumor population. The average DM of the tumor population (1.34 ± 0.40 [standard deviation]) was 23.76% higher than that of the control population (1.08 ± 0.08) (P < .0001), while the average SOAM (22.53 ± 7.82) was 50.73% higher than that of the control population (14.95 ± 4.83) (P < .0001). The DM and SOAM metrics for the control and tumor populations were significantly different when all vessels were pooled between the two animal populations. In addition, each animal in the tumor population had significantly different DM and SOAM metrics relative to the control population (P < .05 for all; P value ranges for DM, 3.89 × 10(-)(7) to 5.63 × 10(-)(3); and those for SOAM, 2.42 × 10(-)(12) to 1.57 × 10(-)(3)). CONCLUSION: Vascular network quantification by using high-spatial-resolution acoustic angiographic images is feasible. Data suggest that the angiogenic processes associated with tumor development in the models studied result in higher instances of vessel tortuosity near the tumor site.


Asunto(s)
Fibrosarcoma/diagnóstico por imagen , Imagenología Tridimensional/métodos , Microcirculación , Neovascularización Patológica/diagnóstico por imagen , Animales , Medios de Contraste , Modelos Animales de Enfermedad , Femenino , Procesamiento de Imagen Asistido por Computador , Microburbujas , Estudios Prospectivos , Ratas , Ratas Endogámicas F344 , Transductores , Ultrasonografía
11.
Neuroimage Clin ; 1(1): 1-17, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-24179732

RESUMEN

Recent contributions to the body of knowledge on traumatic brain injury (TBI) favor the view that multimodal neuroimaging using structural and functional magnetic resonance imaging (MRI and fMRI, respectively) as well as diffusion tensor imaging (DTI) has excellent potential to identify novel biomarkers and predictors of TBI outcome. This is particularly the case when such methods are appropriately combined with volumetric/morphometric analysis of brain structures and with the exploration of TBI-related changes in brain network properties at the level of the connectome. In this context, our present review summarizes recent developments on the roles of these two techniques in the search for novel structural neuroimaging biomarkers that have TBI outcome prognostication value. The themes being explored cover notable trends in this area of research, including (1) the role of advanced MRI processing methods in the analysis of structural pathology, (2) the use of brain connectomics and network analysis to identify outcome biomarkers, and (3) the application of multivariate statistics to predict outcome using neuroimaging metrics. The goal of the review is to draw the community's attention to these recent advances on TBI outcome prediction methods and to encourage the development of new methodologies whereby structural neuroimaging can be used to identify biomarkers of TBI outcome.

12.
Med Image Comput Comput Assist Interv ; 14(Pt 2): 639-46, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21995083

RESUMEN

Standard image registration methods do not account for changes in image appearance. Hence, metamorphosis approaches have been developed which jointly estimate a space deformation and a change in image appearance to construct a spatio-temporal trajectory smoothly transforming a source to a target image. For standard metamorphosis, geometric changes are not explicitly modeled. We propose a geometric metamorphosis formulation, which explains changes in image appearance by a global deformation, a deformation of a geometric model, and an image composition model. This work is motivated by the clinical challenge of predicting the long-term effects of traumatic brain injuries based on time-series images. This work is also applicable to the quantification of tumor progression (e.g., estimating its infiltrating and displacing components) and predicting chronic blood perfusion changes after stroke. We demonstrate the utility of the method using simulated data as well as scans from a clinical traumatic brain injury patient.


Asunto(s)
Lesiones Encefálicas/patología , Diagnóstico por Imagen/métodos , Neoplasias/patología , Algoritmos , Mapeo Encefálico/métodos , Progresión de la Enfermedad , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Modelos Estadísticos , Modelos Teóricos , Perfusión , Programas Informáticos , Accidente Cerebrovascular/patología
13.
Proc IEEE Int Symp Biomed Imaging ; : 407-413, 2011 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-21785755

RESUMEN

Traditional deformable image registration imposes a uniform smoothness constraint on the deformation field. This is not appropriate when registering images visualizing organs that slide relative to each other, and therefore leads to registration inaccuracies. In this paper, we present a deformation field regularization term that is based on anisotropic diffusion and accommodates the deformation field discontinuities that are expected when considering sliding motion. The registration algorithm was assessed first using artificial images of geometric objects. In a second validation, monomodal chest images depicting both respiratory and cardiac motion were generated using an anatomically-realistic software phantom and then registered. Registration accuracy was assessed based on the distances between corresponding segmented organ surfaces. Compared to an established diffusive regularization approach, the anisotropic diffusive regularization gave deformation fields that represented more plausible image correspondences, while giving rise to similar transformed moving images and comparable registration accuracy.

14.
Proc SPIE Int Soc Opt Eng ; 79642011 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21666884

RESUMEN

We present on-going work on multi-resolution sulcal-separable meshing for approach-specific neurosurgery simulation, in conjunction multi-grid and Total Lagrangian Explicit Dynamics finite elements. Conflicting requirements of interactive nonlinear finite elements and small structures lead to a multi-grid framework. Implications for meshing are explicit control over resolution, and prior knowledge of the intended neurosurgical approach and intended path. This information is used to define a subvolume of clinical interest, within some distance of the path and the target pathology. Restricted to this subvolume are a tetrahedralization of finer resolution, the representation of critical tissues, and sulcal separability constraint for all mesh levels.

15.
Neurobiol Aging ; 31(2): 290-300, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18471935

RESUMEN

Histological and magnetic resonance imaging studies have demonstrated that age-associated alterations of the human brain may be at least partially related to vascular alterations. Relatively little information has been published on vascular changes associated with healthy aging, however. The study presented in this paper examined vessels segmented from standardized, high-resolution, magnetic resonance angiograms (MRAs) of 100 healthy volunteers (50 males, 50 females), aged 18-74, without hypertension or other disease likely to affect the vasculature. The subject sample was divided into 5 age groups (n=20/group) with gender equally distributed per group. The anterior cerebral, both middle cerebral, and the posterior circulations were examined for vessel number, vessel radius, and vessel tortuosity. Males exhibited larger vessel radii regardless of age and across all anatomical regions. Both males and females displayed a lower number of MRA-discernible vessels with age, most marked in the posterior circulation. Age-associated tortuosity increases were relatively mild. Our multi-modal image database has been made publicly available for use by other investigators.


Asunto(s)
Envejecimiento/patología , Vasos Sanguíneos/patología , Encéfalo/patología , Adolescente , Adulto , Anciano , Arteria Cerebral Anterior/patología , Femenino , Humanos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Arteria Cerebral Media/patología , Caracteres Sexuales , Adulto Joven
16.
Neuroimage ; 47 Suppl 2: T143-51, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19103295

RESUMEN

A patient with glioblastoma multiforme underwent serial computerized analysis of tumor-associated vasculature defined from magnetic resonance angiographic (MRA) scans obtained over almost a four year period. The clinical course included tumor resection with subsequent radiation therapy, a long symptom-free interval, emergence of a new malignant focus, resection of that focus, a stroke, and treatment with chemotherapy and anti-angiogenic therapy. Image analysis methods included segmentation of vessels from each MRA and statistical comparison of vessel morphology over 4 regions of interest (the initial tumor site, the second tumor site, a distant control region, and the entire brain) to the same 4 regions of interest in 50 healthy volunteers (26 females and 24 males; mean age 39 years). Results suggested that following completion of focal radiation therapy (RT) vessel shape abnormalities, if elevated at the time of RT completion, may progressively normalize for months in focal regions, that progressively severe vessel shape abnormalities can precede the emergence of a gadolinium enhancing lesion by months, that lesion resection can produce a dramatic but highly transient drop in abnormal vessel tortuosity both focally and globally, and that treatment with anti-angiogenic agents does not necessarily normalize vessel shape. Quantitative measurements of vessel morphology as defined from MRA may provide useful insights into tumor development and response to therapy.


Asunto(s)
Vasos Sanguíneos/patología , Neoplasias Encefálicas/patología , Glioblastoma/patología , Procesamiento de Imagen Asistido por Computador , Adulto , Anciano , Inhibidores de la Angiogénesis/uso terapéutico , Vasos Sanguíneos/efectos de los fármacos , Encéfalo/irrigación sanguínea , Encéfalo/efectos de los fármacos , Encéfalo/patología , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirugía , Angiografía Cerebral , Femenino , Glioblastoma/radioterapia , Glioblastoma/cirugía , Humanos , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Recurrencia Local de Neoplasia/cirugía , Accidente Cerebrovascular/tratamiento farmacológico , Accidente Cerebrovascular/patología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
17.
Artículo en Inglés | MEDLINE | ID: mdl-17354829

RESUMEN

We have developed a novel model-to-image registration technique which aligns a 3-dimensional model of vasculature with two semiorthogonal fluoroscopic projections. Our vascular registration method is used to intra-operatively initialize the alignment of a catheter and a preoperative vascular model in the context of image-guided TIPS (Transjugular, Intrahepatic, Portosystemic Shunt formation) surgery. Registration optimization is driven by the intensity information from the projection pairs at sample points along the centerlines of the model. Our algorithm shows speed, accuracy and consistency given clinical data.


Asunto(s)
Imagenología Tridimensional/métodos , Modelos Biológicos , Derivación Portosistémica Intrahepática Transyugular/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Técnica de Sustracción , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Inteligencia Artificial , Simulación por Computador , Arteria Hepática/diagnóstico por imagen , Arteria Hepática/cirugía , Venas Hepáticas/diagnóstico por imagen , Venas Hepáticas/cirugía , Humanos , Reconocimiento de Normas Patrones Automatizadas/métodos , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Interfaz Usuario-Computador
19.
Acad Radiol ; 12(5): 585-95, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15866131

RESUMEN

RATIONALE AND OBJECTIVES: To determine the effects of three image-processing algorithms on diagnostic accuracy of digital mammography in comparison with conventional screen-film mammography. MATERIALS AND METHODS: A total of 201 cases consisting of nonprocessed soft copy versions of the digital mammograms acquired from GE, Fischer, and Trex digital mammography systems (1997-1999) and conventional screen-film mammograms of the same patients were interpreted by nine radiologists. The raw digital data were processed with each of three different image-processing algorithms creating three presentations-manufacturer's default (applied and laser printed to film by each of the manufacturers), MUSICA, and PLAHE-were presented in soft copy display. There were three radiologists per presentation. RESULTS: Area under the receiver operating characteristic curve for GE digital mass cases was worse than screen-film for all digital presentations. The area under the receiver operating characteristic for Trex digital mass cases was better, but only with images processed with the manufacturer's default algorithm. Sensitivity for GE digital mass cases was worse than screen film for all digital presentations. Specificity for Fischer digital calcifications cases was worse than screen film for images processed in default and PLAHE algorithms. Specificity for Trex digital calcifications cases was worse than screen film for images processed with MUSICA. CONCLUSION: Specific image-processing algorithms may be necessary for optimal presentation for interpretation based on machine and lesion type.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Mamografía/instrumentación , Intensificación de Imagen Radiográfica , Algoritmos , Enfermedades de la Mama/diagnóstico por imagen , Humanos , Modelos Lineales , Curva ROC , Sensibilidad y Especificidad
20.
Artículo en Inglés | MEDLINE | ID: mdl-16685829

RESUMEN

Graph methods that summarize vasculature by its branching topology are not sufficient for the statistical characterization of a population of intra-cranial vascular networks. Intra-cranial vascular networks are typified by topological variations and long, wandering paths between branch points. We present a graph-based representation, called spatial graphs, that captures both the branching patterns and the spatial locations of vascular networks. Furthermore, we present companion methods that allow spatial graphs to (1) statistically characterize populations of vascular networks, (2) generate the central vascular network of a population of vascular networks, and (3) distinguish between populations of vascular networks. We evaluate spatial graphs by using them to distinguish the gender and handedness of individuals based on their intra-cranial vascular networks.


Asunto(s)
Algoritmos , Angiografía Cerebral/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Angiografía por Resonancia Magnética/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Inteligencia Artificial , Vasos Sanguíneos , Análisis Discriminante , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...