1.
JAMA Cardiol ; 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38776097

RESUMEN

Importance: Atrial fibrillation and obesity are common, and both are increasing in prevalence. Obesity is associated with failure of cardioversion of atrial fibrillation using a standard single set of defibrillator pads, even at high output. Objective: To compare the efficacy and safety of dual direct-current cardioversion (DCCV) using 2 sets of pads, with each pair simultaneously delivering 200 J, with traditional single 200-J DCCV using 1 set of pads in patients with obesity and atrial fibrillation. Design, Setting, and Participants: This was a prospective, investigator-initiated, patient-blinded, randomized clinical trial spanning 3 years from August 2020 to 2023. As a multicenter trial, the setting included 3 sites in Louisiana. Eligibility criteria included body mass index (BMI) of 35 or higher (calculated as weight in kilograms divided by height in meters squared), age 18 years or older, and planned nonemergent electrical cardioversion for atrial fibrillation. Patients who met inclusion criteria were randomized 1:1. Exclusions occurred due to spontaneous cardioversion, instability, thrombus, or BMI below threshold. Interventions: Dual DCCV vs single DCCV. Main Outcomes and Measures: Return to sinus rhythm, regardless of duration, immediately after the first cardioversion attempt of atrial fibrillation, adverse cardiovascular events, and chest discomfort after the procedure. Results: Of 2079 sequential patients undergoing cardioversion, 276 met inclusion criteria and were approached for participation. Of these, 210 participants were randomized 1:1. After exclusions, 200 patients (median [IQR] age, 67.6 [60.1-72.4] years; 127 male [63.5%]) completed the study. The mean (SD) BMI was 41.2 (6.5). Cardioversion was successful more often with dual DCCV compared with single DCCV (97 of 99 patients [98%] vs 87 of 101 patients [86%]; P = .002). Dual cardioversion predicted success (odds ratio, 6.7; 95% CI, 3.3-13.6; P = .01). Patients in the single cardioversion cohort whose first attempt failed underwent dual cardioversion with all subsequent attempts (up to 3 total), all of which were successful: 12 of 14 after second cardioversion and 2 of 14 after third cardioversion. There was no difference in the rating of postprocedure chest discomfort (median in both groups = 0 of 10; P = .40). There were no cardiovascular complications. Conclusions and Relevance: In patients with obesity (BMI ≥35) undergoing electrical cardioversion for atrial fibrillation, dual DCCV results in greater cardioversion success compared with single DCCV, without any increase in complications or patient discomfort. Trial Registration: ClinicalTrials.gov Identifier: NCT04539158.

4.
Prog Cardiovasc Dis ; 66: 37-45, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34332660

RESUMEN

Aortic stenosis is the most common valvulopathy requiring replacement by means of the surgical or transcatheter approach. Transcatheter aortic valve replacement (TAVR) has quickly become a viable and often preferred treatment strategy compared to surgical aortic valve replacement. However, transcatheter heart valve system deployment not infrequently injures the specialized electrical system of the heart, leading to new conduction disorders including high-grade atrioventricular block and complete heart block (CHB) necessitating permanent pacemaker implantation (PPI), which may lead to deleterious effects on cardiac function and patient outcomes. Additional conduction disturbances (e.g., new-onset persistent left bundle branch block, PR/QRS prolongation, and transient CHB) currently lack clearly defined management algorithms leading to variable strategies among institutions. This article outlines the current understanding of the pathophysiology, patient and procedural risk factors, means for further risk stratification and monitoring of patients without a clear indication for PPI, our institutional approach, and future directions in the management and evaluation of post-TAVR conduction disturbances.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Arritmias Cardíacas/terapia , Estimulación Cardíaca Artificial , Sistema de Conducción Cardíaco/fisiopatología , Frecuencia Cardíaca , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Potenciales de Acción , Estenosis de la Válvula Aórtica/epidemiología , Estenosis de la Válvula Aórtica/fisiopatología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Humanos , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...