Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Esthet Restor Dent ; 35(8): 1279-1285, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37435810

RESUMEN

OBJECTIVE: This study assessed how the distance from the composite interface and the underlying chromatic substrate affect the color adjustment potential (CAP) of two single-shade composites. MATERIALS AND METHODS: Cylinder-shaped specimens were created using Vittra APS Unique (VU), Charisma Diamond One (DO), and a shaded (A3) composite. Some single-shade specimens were surrounded by the A3 composite, forming dual specimens. Color measurements of simple specimens were taken against a gray background using a spectrophotometer. All specimens were positioned at a 45° angle in a viewing booth under illuminant D65, and images were captured with a DSLR camera against gray or A3 backgrounds. Image colors were measured using image processing software and converted to CIELAB coordinates. Color differences (ΔE00 ) between the single-shade composites and the A3 composite were calculated. CAP was determined by comparing data from simple and dual specimens. RESULTS: No clinically significant differences were observed between color measurements obtained from images and the spectrophotometer. CAP was higher for DO compared to VU and increased as the distance from the composite interface decreased and when specimens were positioned against an A3 background. CONCLUSION: The color adjustment potential increased with decreased distance from the composite interface and against a chromatic background. CLINICAL SIGNIFICANCE: Achieving satisfactory color match in restorations using single-shade composites is crucial, and selecting an appropriate underlying substrate is essential. The color adjustment gradually decreases from the restoration margins towards its center.


Asunto(s)
Resinas Compuestas , Color , Espectrofotometría , Ensayo de Materiales
2.
Braz Oral Res ; 37: e035, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37132724

RESUMEN

This study evaluated the background and effect of surrounding colors on the color blending of a single-shade composite used in a thin layer. Disc-shaped specimens (1.0 mm thickness) were built with the Vittra APS Unique composite surrounded (dual specimens) or not surrounded (simple specimens) by a control composite (shade A1, A2, or A3). Simple specimens were also built with only control composites. The specimen color was measured against white and black backgrounds with a spectrophotometer (CIELAB system). The whiteness index for dentistry (WID) was calculated for simple specimens. Differences (ΔE00) in color and translucency parameters (ΔTP00) between the simple/dual specimens and the controls were calculated. The translucency adjustment potential (TAP) and color adjustment potential (CAP) were estimated based on the ratios between data from simple and dual specimens. The Vittra APS Unique composite showed higher WID values than the controls. No differences between ΔTP00_SIMPLE and ΔTP00_DUAL were observed for any of the shades. The composite shade did not affect TAP values. The lowest values of ΔE00_SIMPLE and ΔE00_DUAL were observed for shade A1 regardless of the background color. For the white background, ΔE00_SIMPLE values did not differ from those of ΔE00_DUAL for all shades. Only A1 showed ΔE00_DUAL values lower than ΔE00_SIMPLE when the black background was used. The highest modulus of CAP (negative values for the white background) was observed when shade A1 surrounded the Vittra APS Unique composite. The color blending ability of the single-shade resin composite used in a thin layer was affected by both the surrounding shade and background color.


Asunto(s)
Resinas Compuestas , Color , Espectrofotometría , Ensayo de Materiales
3.
Restor Dent Endod ; 48(1): e7, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36875813

RESUMEN

Objectives: This study aimed to evaluate the surrounding and underlying shades' effect on the color adjustment potential (CAP) of a single-shade composite used in a thin layer. Materials and Methods: Cylinder specimens (1.0 mm thick) were built with the Vittra APS Unique composite, surrounded (dual specimens) or not (simple specimens) by a control composite (shade A1, A2, or A3). Simple specimens were also built only with the control composites. Each specimen's color was measured against white and black backgrounds or the simple control specimens with a spectrophotometer (CIELAB system). The whiteness index for dentistry (WID) and translucency parameters (TP00) were calculated for simple specimens. Differences (ΔE00) in color between the simple/dual specimens and the controls were calculated. The CAP was calculated based on the ratios between data from simple and dual specimens. Results: The Vittra APS Unique composite showed higher WID and TP00 values than the controls. The highest values of ΔE00 were observed among simple specimens. The color measurements of Vittra APS Unique (simple or dual) against the control specimens presented the lowest color differences. Only surrounding the single-shade composite with a shaded composite barely impacted the ΔE00. The highest CAP values were obtained using a shaded composite under simple or dual specimens. Conclusions: The CAP of Vittra APS Unique was strongly affected by the underlying shade, while surrounding this composite with a shaded one barely affected its color adjustment.

4.
Braz. oral res. (Online) ; 37: e035, 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1430033

RESUMEN

Abstract This study evaluated the background and effect of surrounding colors on the color blending of a single-shade composite used in a thin layer. Disc-shaped specimens (1.0 mm thickness) were built with the Vittra APS Unique composite surrounded (dual specimens) or not surrounded (simple specimens) by a control composite (shade A1, A2, or A3). Simple specimens were also built with only control composites. The specimen color was measured against white and black backgrounds with a spectrophotometer (CIELAB system). The whiteness index for dentistry (WID) was calculated for simple specimens. Differences (ΔE00) in color and translucency parameters (ΔTP00) between the simple/dual specimens and the controls were calculated. The translucency adjustment potential (TAP) and color adjustment potential (CAP) were estimated based on the ratios between data from simple and dual specimens. The Vittra APS Unique composite showed higher WID values than the controls. No differences between ΔTP00_SIMPLE and ΔTP00_DUAL were observed for any of the shades. The composite shade did not affect TAP values. The lowest values of ΔE00_SIMPLE and ΔE00_DUAL were observed for shade A1 regardless of the background color. For the white background, ΔE00_SIMPLE values did not differ from those of ΔE00_DUAL for all shades. Only A1 showed ΔE00_DUAL values lower than ΔE00_SIMPLE when the black background was used. The highest modulus of CAP (negative values for the white background) was observed when shade A1 surrounded the Vittra APS Unique composite. The color blending ability of the single-shade resin composite used in a thin layer was affected by both the surrounding shade and background color.

5.
Braz Dent J ; 33(5): 126-132, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36287494

RESUMEN

This study evaluated the effect of surrounded shade and specimens` thickness on the color adjustment potential (CAP) of a single-shade composite. The composite Vittra APS Unique was surrounded (dual specimens) or not (simple specimens) by a control composite (shade A1, A2, or A3). Simple specimens of the control composite were also confectioned. Opacity and whiteness index for dentistry (WID) were calculated for simple specimens. Color differences between the simple (ΔE*SIMPLE)/ dual specimens (ΔE*DUAL) and the controls were calculated. CAP was calculated based on the ratio between ΔE* SIMPLE and ΔE* DUAL. The tested composite presented lower opacity (53 to 62% vs. 80 to 93%) and higher WID (≈ 42 vs. 18 to 32) than controls. Irrespective of the specimens' thickness (1.0/ 1.5 mm), the lowest values of ΔE* SIMPLE (11.1/ 10.8) and ΔE*DUAL (7.2/ 6.1) were observed using the surrounding shade A1. The shade A3 yielded higher ΔE*SIMPLE (16.4/ 17.1) and ΔE* DUAL (11.3/ 12.3) than the A2 (ΔE*SIMPLE = 13.4/ 14.6; and ΔE* DUAL = 9.7/ 10.3). The specimen`s thickness significantly affected the CAP (0.35 and 0.44 for 1.0 and 1.5 mm, respectively) only for shade A1, which had the highest CAP values. The shade A3 resulted in higher CAP values (0.31) than A2 (0.27) when 1.0-mm thick specimens were used, but similar values were observed for 1.5 thick specimens (≈ 0.29). In conclusion, both surrounding shade and specimen thickness can affect the CAP of a single-shade resin composite.


Asunto(s)
Resinas Compuestas , Porcelana Dental , Color , Ensayo de Materiales
6.
Braz. dent. j ; 33(5): 126-132, Sep.-Oct. 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1403789

RESUMEN

Abstract This study evaluated the effect of surrounded shade and specimens` thickness on the color adjustment potential (CAP) of a single-shade composite. The composite Vittra APS Unique was surrounded (dual specimens) or not (simple specimens) by a control composite (shade A1, A2, or A3). Simple specimens of the control composite were also confectioned. Opacity and whiteness index for dentistry (WID) were calculated for simple specimens. Color differences between the simple (ΔE*SIMPLE)/ dual specimens (ΔE*DUAL) and the controls were calculated. CAP was calculated based on the ratio between ΔE* SIMPLE and ΔE* DUAL. The tested composite presented lower opacity (53 to 62% vs. 80 to 93%) and higher WID (≈ 42 vs. 18 to 32) than controls. Irrespective of the specimens' thickness (1.0/ 1.5 mm), the lowest values of ΔE* SIMPLE (11.1/ 10.8) and ΔE*DUAL (7.2/ 6.1) were observed using the surrounding shade A1. The shade A3 yielded higher ΔE*SIMPLE (16.4/ 17.1) and ΔE* DUAL (11.3/ 12.3) than the A2 (ΔE*SIMPLE = 13.4/ 14.6; and ΔE* DUAL = 9.7/ 10.3). The specimen`s thickness significantly affected the CAP (0.35 and 0.44 for 1.0 and 1.5 mm, respectively) only for shade A1, which had the highest CAP values. The shade A3 resulted in higher CAP values (0.31) than A2 (0.27) when 1.0-mm thick specimens were used, but similar values were observed for 1.5 thick specimens (≈ 0.29). In conclusion, both surrounding shade and specimen thickness can affect the CAP of a single-shade resin composite.


Resumo Este estudo avaliou o efeito da cor circundante e da espessura da amostra no potencial de ajuste de cor (PAC) de uma resina monocromática. O compósito Vittra APS Unique foi circundado (amostras duplas) ou não (amostras simples) com um compósito controle (cor A1, A2 ou A3). Amostras simples do compósito controle também foram confeccionadas. A opacidade e o índice de brancura para odontologia (IBO) foram calculados para as amostras simples. As diferenças de cor entre amostras simples (ΔE*SIMPLE) / duplas (ΔE*DUAL) e os controles foram calculados. PAC foi calculado baseado na razão entre ΔE* SIMPLE e ΔE* DUAL. O compósito testado apresentou menor opacidade (53 a 62% vs. 80 a 93%) e maior IBO (≈ 42 vs. 18 a 32) que os controles. Independente da espessura da amostra (1,0/ 1,5 mm), os valores mais baixos de ΔE* SIMPLE (11,1/ 10,8) e ΔE*DUAL (7,2/ 6,1) foram observadas quando a resina circundante era A1. A cor A3 resultou em maior ΔE*SIMPLE (16,4/ 17,1) e ΔE* DUAL (11,3/ 12,3) do que A2 (ΔE*SIMPLE = 13,4/ 14,6; e ΔE* DUAL = 9,7/ 10,3). A espessura das amostras afetou significativamente o PAC (0,35 e 0,44 para 1,0 e 1,5 mm, respectivamente) apenas para a cor A1, que teve os maiores valores de PAC. A cor A3 resultou nos maiores valores de PAC (0,31) que A2 (0,27) quando amostras de 1,0 mm de espessura foram usadas, mas valores similares foram observados para amostras de 1,5 mm (≈ 0,29). Como conclusão, tanto a cor circundante como a espessura das amostras podem afetar o PAC de um compósito resinoso monocromático.

7.
Restor Dent Endod ; 46(3): e37, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34513643

RESUMEN

OBJECTIVES: This systematic review evaluated the efficacy of the supplementary use of the XP-endo Finisher on bacteria content reduction in the root canal system. MATERIALS AND METHODS: In-vitro studies evaluating the use of the XP-endo Finisher on bacteria content were searched in four databases in July 2020. Two authors independently screened the studies for eligibility. Data were extracted, and risk of bias was assessed. Data were meta-analyzed by using random-effects model to compare the effect of the supplementary use (experimental) or not (control) of the XP-endo Finisher on bacteria counting reduction, and results from different endodontic protocols were combined. Four studies met the inclusion criteria while 1 study was excluded from the meta-analysis due to its high risk of bias and outlier data. The 3 studies that made it to the meta-analysis had an unclear risk of bias for at least one criterion. RESULTS: No heterogeneity was observed among the results of the studies included in the meta-analysis. The study excluded from the meta-analysis assessing the bacteria counting deep in the dentin demonstrated further bacteria reduction upon the use of the XP-endo Finisher. CONCLUSIONS: This systematic review found no evidence supporting the supplementary use of the XP-endo Finisher on further bacteria counting the reduction in the root canal.

8.
Restor Dent Endod ; 46(2): e23, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-34123759

RESUMEN

OBJECTIVES: This study assessed the reliability of digital color measurements using images of resin composite specimens captured with a cellphone. MATERIALS AND METHODS: The reference color of cylindrical specimens built-up with the use of resin composite (shades A1, A2, A3, and A4) was measured with a portable spectrophotometer (CIELab). Images of the specimens were obtained individually or pairwise (compared shades in the same photograph) under standardized parameters. The color of the specimens was measured in the images using RGB system and converted to CIELab system using image processing software. Whiteness index (WID) and color differences (ΔE00) were calculated for each color measurement method. For the cellphone, the ΔE00 was calculated between the pairs of shades in separate images and in the same image. Data were analyzed using 2-way repeated-measures analysis of variance (α = 0.05). Linear regression models were used to predict the reference ΔE00 values of those calculated using color measured in the images. RESULTS: Images captured with the cellphone resulted in different WID values from the spectrophotometer only for shades A3 and A4. No difference to the reference ΔE00 was observed when individual images were used. In general, a similar ranking of ΔE00 among resin composite shades was observed for all methods. Stronger correlation coefficients with the reference ΔE00 were observed using individual than pairwise images. CONCLUSIONS: This study showed that the use of cellphone images to measure the color difference seems to be a feasible alternative providing outcomes similar to those obtained with the spectrophotometer.

9.
J. appl. oral sci ; 29: e20200511, 2021. tab, graf
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1143152

RESUMEN

Abstract Objective To evaluate the effect of the association between external and internal tooth bleaching on color changes in dentin and enamel, individually or recombined, previously stained with triple antibiotic paste (TAP). Methodology Forty enamel-dentin specimens from bovine incisors were separated into ten blocks according to similarity in their whiteness index (WID). Three specimens within each block were stained by dentin exposure to TAP, and the remaining specimen was used as control to estimate color changes. Specimens were sectioned to separate tissues, and dentin and enamel colors were measured individually and after being recombined. Alterations in color (CIEDE2000 - ΔE00) and translucency parameter (TP) resulting from staining were estimated by color difference between stained and control specimens. The contribution of each tissue to the color change (CTCC) was also calculated. Non-sectioned stained specimens were bleached by applying sodium perborate on dentin, associated or not with 35% hydrogen peroxide on enamel. Color changes caused by bleaching procedures were estimated and data were analyzed using the paired t-test or Two-way repeated measures ANOVA. Results TAP caused more pronounced changes in dentin, but enamel color was also affected. Both protocols presented a similar ΔE00, and dentin showed the greater color change. After exposure to TAP, we observed a reduction in WID; WID values were the same for bleached and control specimens regardless of protocol. We found no significant effect of substrate and bleaching technique on TP. Enamel played a more critical role in color changes caused by either staining or bleaching procedures. Conclusion Enamel color played a greater role on tooth color changes than dentin. External and internal bleaching association did not improve bleaching effect on specimens stained with TAP.


Asunto(s)
Animales , Bovinos , Color , Esmalte Dental , Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Técnicas In Vitro , Peróxido de Hidrógeno
10.
J Appl Oral Sci ; 29: e20200511, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33331429

RESUMEN

OBJECTIVE: To evaluate the effect of the association between external and internal tooth bleaching on color changes in dentin and enamel, individually or recombined, previously stained with triple antibiotic paste (TAP). METHODOLOGY: Forty enamel-dentin specimens from bovine incisors were separated into ten blocks according to similarity in their whiteness index (WID). Three specimens within each block were stained by dentin exposure to TAP, and the remaining specimen was used as control to estimate color changes. Specimens were sectioned to separate tissues, and dentin and enamel colors were measured individually and after being recombined. Alterations in color (CIEDE2000 - ΔE00) and translucency parameter (TP) resulting from staining were estimated by color difference between stained and control specimens. The contribution of each tissue to the color change (CTCC) was also calculated. Non-sectioned stained specimens were bleached by applying sodium perborate on dentin, associated or not with 35% hydrogen peroxide on enamel. Color changes caused by bleaching procedures were estimated and data were analyzed using the paired t-test or Two-way repeated measures ANOVA. RESULTS: TAP caused more pronounced changes in dentin, but enamel color was also affected. Both protocols presented a similar ΔE00, and dentin showed the greater color change. After exposure to TAP, we observed a reduction in WID; WID values were the same for bleached and control specimens regardless of protocol. We found no significant effect of substrate and bleaching technique on TP. Enamel played a more critical role in color changes caused by either staining or bleaching procedures. CONCLUSION: Enamel color played a greater role on tooth color changes than dentin. External and internal bleaching association did not improve bleaching effect on specimens stained with TAP.


Asunto(s)
Color , Esmalte Dental , Dentina , Blanqueamiento de Dientes , Animales , Bovinos , Peróxido de Hidrógeno , Técnicas In Vitro , Blanqueadores Dentales
11.
Cranio ; 36(1): 19-28, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28128016

RESUMEN

OBJECTIVE: To evaluate the influence of ULF-TENS on the displacement of the mandibular condyle and on the repeatability of centric relation (CR) registration of three different techniques: bimanual manipulation (BM), long strip technique, and harmonic centric occlusal relationship (R.O.C.A. wires). METHODS: Twenty-five participants without temporomandibular disorder (TMD) underwent two study stages conducted via electronic position analysis: (1) three CR records were made, one for each manipulation technique; (2) the ULF-TENS was applied for 30 min, and after that the same CR records were repeated. STATISTICAL ANALYSES: Mann-Whitney, ICC, and one-tailed F test. RESULTS: The ULF-TENS did not influence the condyle total displacement, regardless of CR recording technique used (p > 0.05). BM showed an improvement in repeatability after ULF-TENS. DISCUSSION: Concerning the variance, BM showed less variation at the X-axis. Long strip technique and R.O.C.A. wires varied less at the Y-axis. Long strip technique was again less variable at the Z-axis.


Asunto(s)
Relación Céntrica , Cóndilo Mandibular/fisiopatología , Trastornos de la Articulación Temporomandibular/fisiopatología , Trastornos de la Articulación Temporomandibular/terapia , Estimulación Eléctrica Transcutánea del Nervio/métodos , Adulto , Femenino , Humanos , Registro de la Relación Maxilomandibular , Masculino , Encuestas y Cuestionarios
12.
Cranio ; 35(1): 46-51, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27077251

RESUMEN

OBJECTIVE: To compare the amplitude of mandibular movement measurements obtained by two different methods: the ultrasound JAM system and digital caliper rule in individuals with temporomandibular disorder (TMD) vs. METHOD: Sixty individuals, without distinction between sex and age were evaluated: 30 with diagnosis of TMD (RDC/TMD) and 30 controls. Mandibular movements of opening, protrusion, and left and right laterality were measured by means of two Instruments: Digital caliper rule and 3D ultrasonic Jaw Motion Analyzer (JMA-Zebris Medizintechnik, Isny/Allgäu, Germany). Data obtained were analyzed by descriptive analysis and compared by parametric statistics (Student's t-test), adopting a 5% level of significance. RESULTS: When comparing the digital caliper rule with JMA, no significant differences were found for any of the movements evaluated (p > 0.05). In the comparison between groups, a difference was found in protrusion for both instruments used: JMA (p = 0.004) and digital caliper rule (p = 0.003), with the TMD group presenting reduced movement of protrusion when compared with the control group. DISCUSSION: This study found no differences in obtaining the amplitude of mandibular movements when using the digital caliper rule or JMA system; both methods are effective. However, the ultrasonic system allows other types of analyses to be performed, such as the trajectory and speed of movement. Among the mandibular movements analyzed, protrusion was shown to be more compromised and limited in TMDs.


Asunto(s)
Mandíbula/fisiopatología , Rango del Movimiento Articular/fisiología , Trastornos de la Articulación Temporomandibular/fisiopatología , Ultrasonografía/métodos , Brasil , Estudios Transversales , Humanos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Mandíbula/diagnóstico por imagen , Movimiento/fisiología , Examen Físico/métodos , Trastornos de la Articulación Temporomandibular/diagnóstico por imagen , Ultrasonografía/instrumentación
13.
J Oral Maxillofac Surg ; 70(1): 12-8, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21940090

RESUMEN

PURPOSE: Third molar removal is usually accompanied by a high degree of patient anxiety. Lack of knowledge about the procedure is a major contributor to this anxiety. The aim of this study was to investigate the perioperative perceptions of patients who underwent extraction of third molars to assess their concerns during the surgical experience. MATERIALS AND METHODS: Issues related to preoperative, intraoperative, and postoperative phases of the experience were assessed with the purpose of identifying the most frequent questions and misconceptions. Data were assessed to correlate the influence of previous experience with extraction(s) with the appropriate knowledge of third molar surgery, as well as knowledge variations as to the age and gender of the patients. RESULTS: The sample was composed of 67 patients (43 female patients and 24 male patients) divided into 2 groups: The first had some previous experience with extractions (25 patients), and the second had no experience (42 patients). The most frequent questions regarded the number of teeth to be extracted (65.4%), and the most prevalent misconception was about medications before surgery (28.4%). Patients with a previous history of dental extractions had more questions about use of medication before surgery (P = .03). Patients without previous experience with extraction had more concerns about anesthesia techniques (P = .02) or the number of teeth that would be removed during the same procedure (P = .02). Other questions and misconceptions were not different between these groups. CONCLUSIONS: Patients with a history of tooth extraction and those without it presented different patterns of knowledge about third molar surgery. Both groups of patients needed detailed perioperative instructions about the procedure. These results may provide oral and maxillofacial surgeons with useful information about patients' knowledge throughout the surgical process.


Asunto(s)
Conocimientos, Actitudes y Práctica en Salud , Tercer Molar/cirugía , Extracción Dental/métodos , Diente Impactado/cirugía , Adolescente , Adulto , Factores de Edad , Anestesia Dental/métodos , Actitud Frente a la Salud , Estudios Transversales , Ansiedad al Tratamiento Odontológico/psicología , Dieta , Quimioterapia , Femenino , Humanos , Cuidados Intraoperatorios , Masculino , Persona de Mediana Edad , Higiene Bucal , Dolor Postoperatorio/clasificación , Educación del Paciente como Asunto , Cuidados Posoperatorios , Cuidados Preoperatorios , Estudios Prospectivos , Recuperación de la Función/fisiología , Factores Sexuales , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...