Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Open Vet J ; 14(3): 846-851, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38682139

RESUMEN

Background: Healthy vision in humans and animals requires a stable tear film. The environmental factor could affect the status of the tear film. Therefore, assessing the tear film in animals is essential to avoid visual system disturbance. Aim: The current research used a noninvasive device to evaluate the tear meniscus height (TMH) and lipid layer pattern (LLP) in domestic cats. In addition, the scores were compared with those of humans with healthy eyes. Methods: Fifty-four domestic cats (28 males and 26 females; mean ± SD = 13.9 ± 18.2 months) were randomly selected and included in the study. The cats were healthy, without any ocular disorders or diseases. Fifty-four healthy eye subjects (27 males and 27 females; mean ± SD = 25.6 ± 5.1 years) were randomly recruited and took part in the study for comparison. EASYTEAR View+ was used, for the first time, to assess the tear film parameters on the right eye of each subject. The examiner allowed a 5-minute gap between the tests. Each test was performed by the same examiner three times, followed by calculating the mean scores. Results: Significant differences (Mann-Whitney U test) were found in the median scores of LLP (p = 0.009) between cats and subjects with healthy eyes. The median TMH score was higher in cats (0.18 mm) than in humans (0.14). However, no significant difference (Mann-Whitney U Test, p = 0.210) exists in the TMH scores between cats and humans. The LLP analysis indicated that a dense white-blue lipid layer (grade 4 or D; lipid layer thickness, LLT, = approximately 80 nm) was predominant in both cats (N = 24, 44.4%) and humans (N = 29, 53.7%). In comparison, variable colors lipid layer (grade 5 or E; LLT = 90-140 nm) was a minority in cats (N = 5, 9.3%) and common in humans (N = 16, 29.6%). The statistical analysis indicated medium correlations between cats' TMH and LLP scores (r = 0.431, p < 0.01) and between age and TMH scores in humans (r = 0.440, p < 0.01). In addition, it indicated a weak correlation (r = 0.291, p < 0.05) between the LLP scores in cats and humans. Conclusion: Assessing animals' tear film is essential to avoid any ocular disorders. EASYTEAR View+ is efficiently used to evaluate domestic cats' TMH and LLP. Cats have thicker lipid layers and longer TMH comparable to those reported for humans with healthy eyes.


Asunto(s)
Lágrimas , Animales , Gatos/fisiología , Lágrimas/fisiología , Masculino , Femenino , Lípidos/análisis , Humanos
2.
Open Vet J ; 14(3): 879-884, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38682146

RESUMEN

Background: Maintaining a stable tear film is crucial for having healthy human and animal vision. Animals are expected to have thicker lipid layers than humans due to living in high-temperature and humid environments. Aim: The study aimed to evaluate the lipid layer patterns (LLPs) in Arabian dogs and rabbits using a non-invasive, practical, and easy-to-use device and compare them to humans with healthy eyes. Methods: The study included 75 domestic Arabian dogs (42 males and 33 females; mean ± SD = 6.1 ± 12.7 months) and 75 rabbits (37 males and 38 females; mean ± SD = 3.1 ± 3.4 months). In addition, 75 individuals with healthy eyes (39 males and 36 females; mean ± SD = 25.7 ± 5.0 years) were included for comparison. EASYTEAR View+ assessed the LLP in each animal's and individual's right eye. Results: The median LLP grades significantly differed between dogs and humans (Mann-Whitney U test, p < 0.001). Similarly, the LLP grades differed significantly between rabbits and humans (Mann-Whitney U test, p < 0.001). No significant difference (Mann-Whitney U test) in the LLP grades between dogs and rabbits was found. The analysis indicated that most dogs had either an A (34.7%) or a B grade (37.3%). Similarly, rabbits had predominantly A or 1 (46.7%) and B (30.7%) grades. On the other hand, humans had predominantly D (53.3%) and E (30.7%) grades. Conclusion: The EASYTEAR View+ has been employed to assess LLP in dogs and rabbits, and the measurements were compared to those of humans with normal ocular health. Dogs and rabbits have thinner lipid layers than healthy humans.


Asunto(s)
Lípidos , Animales , Conejos , Perros , Masculino , Femenino , Lípidos/análisis , Lágrimas/fisiología , Humanos
3.
PLoS One ; 18(2): e0280853, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36735697

RESUMEN

PURPOSE: To investigate the effect of the addition of a low concentration of sodium chloride (NaCl) and potassium chloride (KCl) solutions on the tear ferning (TF) patterns of tears collected from humans. METHODS: A tear sample (20 µL) was collected from the right eye of 23 males and 7 females (25.4 ± 6.6 years). The tears were collected in one sitting for healthy subjects (N = 13). For dry eye participants (N = 17), the tear samples were collected in two separate settings with five minutes gap in between. A sample (1 µL) from each tear was dried on a glass slide, and the obtained ferns were observed using a microscope and graded using the five-point TF grading scale. Mixtures of tear samples (0.5 µL) and different volumes (0.5-2.5 µL) of each electrolyte (10-30 mg in 100 mL of water) solution were prepared, and their TF patterns were recorded and compared with those of the corresponding pure tears. RESULTS: Significant improvements (Wilcoxon test, P < 0.001) have been seen in the TF grades of the tear samples after the addition of NaCl and KCl solutions. A significant difference (Wilcoxon test, P = 0.016) was found between the TF grades when NaCl and KCl solutions were added to the tear samples. The TF grades of pure tears collected from dry-eye subjects ranged from 2.1 to 3.5, based on the five points grading scale, and decreased to be in the range of 0.4 to 1.6 after the addition of electrolyte solutions. While the TF grades of pure tears collected from normal-eye ranged from 1.2 to 1.9 and improved after the addition of electrolyte solution to be in the range of 0.4 to 1.5. CONCLUSIONS: The TF test was used in vitro to assess the impact of the addition of a low concentration of sodium and potassium chloride solutions on tears collected from humans. The TF grades of human tears significantly improved after the addition of either sodium or potassium chloride solution. The mechanism for the improvement in TF grades due to the addition of electrolyte solutions must be investigated.


Asunto(s)
Síndromes de Ojo Seco , Laceraciones , Masculino , Femenino , Humanos , Cloruro de Sodio , Cloruro de Potasio , Electrólitos , Lágrimas , Sodio
4.
PLoS One ; 17(11): e0277803, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36383575

RESUMEN

PURPOSE: Due to the COVID-19 pandemic, wearing a face mask has become an essential measure to reduce the rate of virus spreading. The aim of the study was to assess the effect of wearing a surgical face mask for a short period on the tear film parameters in subjects with a high body mass index (BMI). METHODS: Twenty-five females with a high BMI (31.4 ± 5.5 kg/m2) aged 18-35 years (22.7 ± 4.6 years) participated in the study. In addition, a control group consisting of 25 females (23.0 ± 6.7 years) with a high BMI (29.9 ± 4.1 kg/m2) participated in the study in which no mask was worn. The standardized patient evaluation of eye dryness (SPEED) questionnaire was completed first, followed by the phenol red thread (PRT) and tear ferning (TF) tests, before wearing the face mask. The subjects wore the face mask for 1 hour, and the measurements were performed again immediately after its removal. For the control group, the measurements were performed twice with one hour gap. RESULTS: Significant (Wilcoxon test, p < 0.05) differences were found between the SPEED scores (p = 0.035) and the PRT measurement (p = 0.042), before and after wearing the surgical face mask. The PRT scores have improved after wearing the surgical face mask, while the dry eye symptoms detected by the SPEED questionnaire have increased. On the other hand, no significant (Wilcoxon test, p = 0.201) differences were found between the TF grades before and after wearing a surgical face mask. For the control group, no significant (Wilcoxon test, p > 0.05) differences were found between the two scores from the SPEED questionnaire and the PRT, and TF tests. CONCLUSIONS: Wearing a surgical face mask for a short duration leads to a change in volume and quality of tears as well as dry eye symptoms in women with a high BMI.


Asunto(s)
COVID-19 , Síndromes de Ojo Seco , Laceraciones , Humanos , Femenino , Máscaras , Índice de Masa Corporal , Pandemias , Síndromes de Ojo Seco/etiología , Síndromes de Ojo Seco/diagnóstico , Fenolsulfonftaleína
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...