Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-19964906

RESUMEN

Optimizing wavelength selection for monitoring perfusion during liver transplant requires an in-depth characterization of liver optical properties. With these, the impact of liver absorption and scattering properties can be investigated to select optimal wavelengths for perfusion monitoring. To accomplish this, we are developing a single integrating-sphere-based technique using a unique spatially resolved diffuse reflectance system for multispectral optical properties determination for thick samples. We report early results using a monochromatic source to measure the optical properties of well characterized tissue phantoms made from polystyrene spheres and Trypan blue. The presented results demonstrate the feasibility of using this unique system to measure optical properties of tissue phantoms. We are currently in the process of implementing an automated Levenberg-Marquardt diffuse-reflectance-profile fitting algorithm to enable near realtime robust computation of sample optical properties. Future work will focus on the incorporation of multispectral capability to provide needed data to facilitate development of more realistic liver tissue phantoms.


Asunto(s)
Trasplante de Hígado/instrumentación , Trasplante de Hígado/métodos , Fenómenos Ópticos , Prótesis e Implantes , Animales , Difusión , Hemoglobinas/metabolismo , Hígado/diagnóstico por imagen , Ratones , Oxígeno/metabolismo , Perfusión , Tomografía Computarizada por Rayos X
2.
J Opt Soc Am A Opt Image Sci Vis ; 23(2): 468-75, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16477851

RESUMEN

The pseudodielectric function is often used to represent ellipsometric data and corresponds to the actual dielectric functions of materials when there is no surface overlayer and the material is isotropic. If a uniaxial material is oriented such that the optic axis is in the plane of incidence or is perpendicular to the plane of incidence, then the cross-polarization terms are zero and appropriate pseudodielectric functions can be determined from the ellipsometry data. We calculate the pseudodielectric functions for uniaxial crystals in three primary symmetry directions: (1) the optic axis is perpendicular to the plane of incidence, (2) the optic axis is in the plane of the sample surface and parallel to the plane of incidence, and (3) the optic axis is in the plane of the sample surface and perpendicular to the plane of incidence. These results are expanded in terms of the difference in the ordinary and extraordinary dielectric functions and compared with the approximation of Aspnes [J. Opt. Soc. Am. 70, 1275 (1980)]. Comparisons are made with experimental results on oriented crystals of rutile (TiO2), and a simple procedure is presented to determine the complex dielectric function from standard ellipsometry techniques.

3.
Diabetes Technol Ther ; 3(2): 201-7, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11478325

RESUMEN

In the recent past, several noninvasive optically based methods have been proposed for physiologic glucose sensing. One proposed optical sensing site has been the eye, which, due to its unique optical properties, can be considered as a transparent optical window into the body. In particular, the aqueous humor within the anterior chamber of the eye has been shown to contain glucose levels correlated to those of blood. Concern, however, has been expressed that using the aqueous humor solution as a measure of blood glucose may be problematic due to the potential transport time delay between the blood and the aqueous humor glucose concentrations. This investigation was performed to measure the transport time delay in a rabbit model. The time delay between the blood and aqueous humor glucose concentrations was measured invasively in five New Zealand White rabbits over a series of weeks. An anesthesia protocol containing the drug Xylazine was used to elevate the blood glucose levels to a level commonly seen in diabetic patients. The difference between the glucose peak location times occurring in the blood and aqueous humor glucose response was measured and defined as the transport time delay. The average transport time lag was measured to be under 5 min. This measured time delay indicates that, indeed, the eye could potentially be used as a sensing site for indirect blood glucose measurements and may eventually aid the development of a noninvasive glucose sensor due to its unique optical properties compared to other biological tissues.


Asunto(s)
Humor Acuoso/metabolismo , Glucemia/metabolismo , Glucosa/metabolismo , Anestésicos Locales , Animales , Transporte Biológico , Automonitorización de la Glucosa Sanguínea/métodos , Automonitorización de la Glucosa Sanguínea/tendencias , Diabetes Mellitus/inducido químicamente , Diabetes Mellitus/metabolismo , Modelos Animales de Enfermedad , Lidocaína , Concentración Osmolar , Conejos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS