Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 101(5): 911-917, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36856010

RESUMEN

BACKGROUND: Chronic total occlusion (CTO) revascularization is a major source of radiation for both patients and physicians. Therefore, efforts to minimize radiation during CTO percutaneous coronary intervention (PCI) are highly encouraged. AIMS: To evaluate the impact of an Ultra Low fluoroscopic Dose Protocol (ULDP), based on 3.75 frames per second for the fluoroscopy and 7.5 frames per second for the cine acquisition, during CTO PCI. METHODS: One hundred fifty consecutive patients who underwent CTO PCI were retrospectively enrolled. Eighty-five underwent standard dose protocol (SDP) and 65 ULDP. Radiation exposure and acute clinical outcomes were compared between groups. Results were stratified according to lesion complexity. RESULTS: Patients undergoing ULDP, as compared to those undergoing SDP, showed a significant reduction of kerma area product, both for simple lesions (6861.0 vs. 13236.0 mGy × cm2 ; p = 0.014) and complex lesions (CL) (8865.0 vs. 16618.0 mGy × cm2 ; p < 0.001). Similarly, Air Kerma (AK) was lower when ULDP was used (1222.5 vs. 2015.0 cGy in SL, p = 0.134; 1499.0 vs. 2794.0 cGy in CL, p < 0.001). No significant differences were reported regarding procedural success and in-hospital major adverse cardiovascular events between groups. Notably, there was not any crossover from ULDO to SDP due to poor quality images. Interestingly, fluoroscopy time, procedural time and contrast volume was significantly lower in patients undergoing ULDP only for CLs. CONCLUSIONS: ULDP significantly reduces radiation exposure in the setting of high complexity procedures such as CTO PCI. This reduction seemed to be greater with increased procedural complexity and did not impact acute success or adverse clinical events.


Asunto(s)
Oclusión Coronaria , Fluoroscopía , Intervención Coronaria Percutánea , Humanos , Enfermedad Crónica , Angiografía Coronaria/efectos adversos , Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Oclusión Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Sistema de Registros , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
2.
Minerva Cardiol Angiol ; 71(1): 70-76, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34338484

RESUMEN

BACKGROUND: Bioresorbable scaffolds (BRS) have been introduced to overcome the limitations of drug-eluting stents and the ABSORB (Everolimus-Eluting BRS, Abbott Vascular, Santa Clara, CA, USA) was the most extensively tested. Nevertheless, major RCTs reported higher rates of target lesion failures and BRS thrombosis at 3 years follow-up, bringing to the withdrawing of the device from the market. It has been suggested that a better lesions selection and an optimized implantation technique could mitigate the displayed adverse results. METHODS: Consecutive patients undergoing BRS implantation were included in this observational, single center study. Clinical follow-up was conducted up to 4 years. Endpoint of interest was the target lesion failure (TLF), a composite outcome including cardiac death, target vessel myocardial infarction and target lesion revascularization. RESULTS: A total of 62 patients with a mean age of 55±8.5 years were analyzed of which 70.9% presented with an acute coronary syndrome and 59.6% with myocardial infarction. A total of 100 lesions were treated and 51.6% were complex (B2/C). Predilatation was performed in all the case, post-dilatation in 74.1%. All the target vessel reference diameter (RVD) were >2.5 mm (average RVD 3.2±0.24 mm). At 4 years, the rate for TLF was 6.9%. Subgroup's analysis did not show significative differences among groups although consistently higher event rates were found for RVD <2.5 mm (12.6% vs. 6.4%, P=0.5), BRS overlapping (11.8% vs. 5%, P=0.2) and ticagrelor instead of clopidogrel on top of cardioaspirin (9.1% vs. 3%, P=0.2). CONCLUSIONS: This small-sized real-world registry displays lower rates of clinical events during long-term follow-up in respect to previous studies. The avoidance of implantation in small vessels, inclusion of acute myocardial infarction and extensive performance of BRS post-dilatation could explain the observed better results. Long-term outcomes of the ongoing ABSORB IV Trial are needed to confirm this data.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Humanos , Persona de Mediana Edad , Everolimus/uso terapéutico , Implantes Absorbibles , Resultado del Tratamiento , Infarto del Miocardio/cirugía
3.
J Innov Card Rhythm Manag ; 12(1): 4364-4366, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33520351

RESUMEN

A 71-year-old female patient was referred to our center to upgrade a dual-chamber pacemaker to a cardiac resynchronization therapy defibrillator (CRT-D) following the detection of worsened systolic function (ejection fraction:25%-30%) via transthoracic echocardiography. The patient had situs inversus totalis with dextrocardia. She had undergone mitral valve replacement and tricuspid annuloplasty in July 2019, with a concomitant left upper pulmonary lobectomy for neoplasm, detected at cardiac tomography incidentally. In January 2020, we performed an upgrade of the preexisting device to a CRT-D system because the patient developed heart failure, reduction in systolic function, and numerous nonsustained ventricular tachycardias. The right ventricular lead that had been previously implanted was extracted. To facilitate the intervention, we decided to flip the fluoroscopic image, obtained with a right-anterior oblique view, by 180° (right-left), creating the optical impression of a levocardial position.

4.
Europace ; 21(10): 1566-1574, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31390465

RESUMEN

AIMS: Twelve-lead electrocardiogram (ECG) is an established tool in the evaluation of athletes, providing information about life-threatening cardiovascular diseases, such as long QT syndrome. However, the interpretation of ECG is sometimes challenging in children, particularly for the repolarization phase. The aim of this prospective, longitudinal study was to determinate the distribution of QT interval in children practicing sport and to evaluate changes in QT duration overtime. METHODS AND RESULTS: A population of 1473 preadolescents practising sport (12.0 ± 1.8 years, 7-15 years) was analysed. Each athlete was evaluated at baseline, mid-term, and end of the study (mean follow-up: 3 ± 1 years). QT interval was corrected with Bazett (B) and Fridericia (F) formulae. At baseline QT interval corrected with the Bazett formula (QTcB) was 412 ± 25 ms and QT interval corrected with the Fridericia formula (QTcF) 387 ± 21 ms, with no changes during follow-up. Ten children (0.68%) had an abnormal QTc. In those with QTcB and QTcF ≥480 ms, QTc duration persisted abnormal during the follow-up and they were disqualified. Conversely, children with 460 ms < (QTcB) <480 ms had a normal QTc interval at the end of the study. These children had also a normal QTcF. Mean difference in the calculation of QT between the two formulae was 25 ± 11 ms (P < 0.0001). For resting heart rate (HR) ≥82 b.p.m., QTcF was independent from HR contrary to QTcB. CONCLUSION: Normal QTc interval does not change over time in preadolescents. A minority of them has a QTc ≥480 ms; in these subjects, QTc interval remains prolonged. The use of Bazett and Fridericia correction formulae is not interchangeable and the Fridericia correction should be preferred in preadolescents with a resting HR ≥82 b.p.m.


Asunto(s)
Algoritmos , Electrocardiografía/métodos , Frecuencia Cardíaca/fisiología , Síndrome de QT Prolongado/fisiopatología , Deportes/fisiología , Adolescente , Niño , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...