Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Vet J ; 304: 106098, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38462169

RESUMEN

Corkscrew claw (CC) in dairy cattle is increasingly reported in dairy herds. CC is a progressive deformity of the claw capsule with uncertain aetiology and pathogenesis. Genetics and specific environmental factors are suspected of contributing to the development of this irreversible condition. CC has been found in lame cows; however, the cause and effect has not been established. To perform analysis of risk factors, treatment and pathogenesis, a definition of severity scores is called for. The aim of this study was to measure and analyse CC characteristics from photos of cows' feet to describe and evaluate a scoring system for CC. Width of the visible part of the axial wall, degree of contact between the toe and the floor and angle of the distal part of the abaxial wall as a proxy for the deviation of the abaxial wall was measured from 393 pictures of CC. Based on the measurements on the claws, the parameter "width of the axial wall" was chosen to define the scores. The parameter was divided into three intervals to define either mild CC 0.3-2.0 cm, moderate CC 2.1-3.5 cm or severe CC>3.5 cm and correlation between the parameters; level of contact between the toe and the floor and the angle of the distal abaxial wall was evaluated. There was a significant positive linear correlation between width of the axial wall and angle of the distal part of the abaxial wall (r=0.91), the wider the axial wall, the more the abaxial wall deviated in the distal part. As the width of the axial wall increased the toe increasingly lost contact with the floor, this association was significant for mild CC and moderate CC but not for severe CC. The Interobserver agreement of the CC Scoring system was tested by 30 claw trimmers each scoring 32 cadaver feet and by 2 trained observers on 28 photos of feet using Cohen´s weighted kappa and showed substantial to almost perfect agreement between untrained and trained observers, respectively.


Asunto(s)
Enfermedades de los Bovinos , Enfermedades del Pie , Pezuñas y Garras , Femenino , Bovinos , Animales , Pezuñas y Garras/patología , Enfermedades del Pie/veterinaria , Enfermedades del Pie/patología , Pie/patología , Pisos y Cubiertas de Piso , Enfermedades de los Bovinos/patología , Cojera Animal/etiología
2.
JDS Commun ; 3(2): 160, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36342858

RESUMEN

[This corrects the article DOI: 10.3168/jdsc.2021-0079.].

3.
Animal ; 16(6): 100552, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35687942

RESUMEN

Estimates of milk constituents by Fourier-transform mid-infrared (FTIR) analysis have been shown to be a useful tool in monitoring energy deficit in early-lactation dairy cows. Our objectives were to describe the diurnal variation in milk fatty acids (FAs) and estimate the association of hyperketonemia with concentrations and diurnal patterns of FTIR estimates of milk FA. Blood samples were collected via jugular catheters bihourly for 5 d from multiparous Holstein cows (n = 28) enrolled between 3 and 9 days in milk. Milk samples were collected thrice daily at 0600, 1400, and 2200 h for d 2, 3, and 4 of the study period. Cows were retrospectively classified as hyperketonemic (HYK; n = 13) or non-HYK (n = 15) based on blood beta-hydroxybutyrate (bBHB) concentrations analyzed during the study period. Cows were classified as HYK if bBHB was ≥ 1.2 mmol/l for ≥ 50% (22/44) of bihourly timepoints; cows were classified as non-HYK if bBHB was ≥ 1.2 mmol/l for < 50% of bihourly timepoints. The HYK cows had bBHB ≥ 1.2 mmol/l for 31.4 ± 6.8 timepoints while the non-HYK cows had bBHB ≥ 1.2 mmol/l for 8.0 ± 3.9 timepoints. We used generalized linear mixed models to analyze concentrations of milk FA over time and differences between HYK groups. The relative percentage of de novo, mixed, and preformed FAs all followed diurnal patterns, however only the yield of preformed FA diurnally cycled, reaching a nadir at 0600 h and peaking at 1400 h. The yield per milking of preformed FA was also greater in the HYK cows than in the non-HYK cows. Oleic acid in milk followed a similar diurnal pattern to the yield of preformed FA, likely driving the cyclical nature of preformed FA. Finally, stearic acid was greater in HYK cows. Our results suggest that FTIR estimates of milk FA offer the potential to provide insight on the energy status of early-lactation cows, and when interested in understanding the absolute concentrations and yields of milk FA, diurnal variation should be considered.


Asunto(s)
Enfermedades de los Bovinos , Cetosis , Ácido 3-Hidroxibutírico , Animales , Bovinos , Ácidos Grasos/análisis , Femenino , Cetosis/veterinaria , Lactancia , Leche/química , Estudios Retrospectivos
4.
J Dairy Sci ; 104(4): 4837-4846, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33612216

RESUMEN

Claw horn disruption lesions are a common cause of lameness in dairy cattle. It is commonly agreed that they develop due to excessive pressure from the distal phalanx on the horn-producing tissue in the sole. The distal phalanx is supported by the suspensory apparatus, a large proportion of which is made up of connective tissue. It has been hypothesized that increased laxity of the connective tissue due to hormonal changes around calving may lead to decreased support of the distal phalanx, resulting in a sinking of the bone and increased pressure on the horn-producing tissue. In this longitudinal study, our first objective was to determine whether the thickness of the soft tissue related to the claw sole (the combined depth of the digital cushion and corium; soft-tissue thickness, STT) in the weight-bearing hind claws of live heifers changed around calving (the period from approximately 3 wk before calving to 2 wk after calving). Our second objective was to evaluate the relationship between the body condition score (BCS) of recruited heifers and the STT estimates we obtained. We measured STT (defined as the distance between the distal phalanx and the sole horn) in the apex and the posterior part of the sole of the hind claws of 34 Holstein heifers 4 times over 3 to 4 wk around calving. We determined STT by ultrasonographic measurements through the sole horn on weight-bearing claws. The overall mean STT at site 1 was 3.3 mm [minimum-maximum (min-max): 1.8 to 5.2 mm], and the mean at site 2 was 3.7 mm (min-max: 2.2 to 5.8). The overall mean STT was thickest in the first examination before calving [site 1: 3.4 mm (min-max: 1.9 to 4.7); site 2: 4.1 mm (min-max: 2.7 to 5.8)] and thinnest at site 1 in the second examination after calving (3.2 mm, min-max: 1.8 to 5.2) and at site 2 at the first examination after calving (3.5 mm, min-max: 2.2 to 5.0). We observed an average reduction in STT of -0.2 mm (min-max: 0.8 to -0.9 mm) at site 1 during the study period, but we did not observe this reduction in all animals. At site 2, we found an average reduction in STT of -0.6 mm (min-max: 0.8 to -1.3 mm) from 10 d before calving to 5 d after calving, corresponding to a decrease of approximately 15% (min-max: 0 to 31%). We suggest that this reduction was caused by a rotation of the distal phalanx toward the posterior part of the sole horn in the weeks around calving. During the same period, heifer BCS decreased between 0.25 and 0.5 increments in the BCS scale, but we found no correlation between BCS and STT. However, the heifers experienced many changes related to management, feeding, and time budget during the study period, and the rotation of the distal phalanx and reduction of the STT might be explained not only by calving but also by other factors that affect heifers and their claws during the transition period.


Asunto(s)
Enfermedades de los Bovinos , Enfermedades del Pie , Pezuñas y Garras , Animales , Bovinos , Enfermedades de los Bovinos/diagnóstico por imagen , Femenino , Enfermedades del Pie/veterinaria , Cojera Animal , Estudios Longitudinales
5.
JDS Commun ; 2(4): 207-211, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36338443

RESUMEN

Subclinical hypocalcemia, a reduction in blood calcium concentrations without apparent clinical signs of milk fever, occurs in 25 to 50% of early-postpartum dairy cows. Research has shown that these cows are at an increased risk of additional early-lactation diseases, including left displaced abomasum (LDA), compared with their normocalcemic counterparts. However, no work has assessed the association of total calcium (tCa) concentration at the time of LDA correction with subsequent milk yield and survival within the herd. Pending future development of an economical and accurate on-farm test for hypocalcemia, the ability to assess LDA prognosis after surgical correction based on precorrection blood tCa concentration is of interest to practitioners. Therefore, our objective was to determine the association of blood tCa concentration at the time of LDA surgical correction with milk yield and herd removal in the 60 d after correction. Nine bovine practitioners, located in New York State, were involved in sample collection from 17 herds for this prospective cohort study. Immediately following LDA diagnosis and before surgical correction, blood samples were collected from 152 dairy cows within the first 30 d in milk for serum tCa determination. The association of tCa with milk yield (n = 110) and herd removal (n = 127) in the first 60 d after LDA surgical correction was analyzed using repeated-measures ANOVA and a generalized linear mixed model, respectively, controlling for parity and days in milk at LDA surgical correction and the random effect of herd or practitioner. We found no evidence to support an association of tCa at time of LDA diagnosis with subsequent milk yield, and when cows were grouped by median tCa into low and high groups (tCa ≤2.1 and >2.1 mmol/L, respectively), subsequent milk production was similar (39.4 ± 1.6 and 40.1 ± 1.4 kg/d for low and high, respectively). Furthermore, we found no evidence to support an association of tCa at time of LDA diagnosis with the odds of herd removal (odds ratio = 0.6; 95% confidence interval = 0.4-1.7). Therefore, our study provided no clear evidence to support the association of tCa at time of LDA diagnosis and correction with either milk yield or herd removal during the 8 wk after correction. However, it did demonstrate low to extremely low tCa concentration in cows with LDA. Whether calcium supplementation would improve health and production outcomes in these cows is unclear and worth investigating further.

6.
J Dairy Sci ; 104(1): 715-727, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33189283

RESUMEN

Periparturient cows go through a period of immune suppression often marked by immune cell dysfunction. Further exacerbation of this dysfunction through early-lactation excessive energy deficit (EED) has been associated with increased susceptibility to infectious conditions such as mastitis. Our objective was to explore the association of milk somatic cell score (SCS) and clinical mastitis (CM) diagnosis in cows identified with EED, diagnosed using each of the following: blood and milk ß-hydroxybutyrate (BHB), milk predicted blood nonesterified fatty acid (mpbNEFA) concentrations, or milk de novo fatty acid (FA) relative percentages (rel %). We analyzed data collected from 396 multiparous Holstein cows from 2 New York farms in a prospective cohort study. Coccygeal vessel blood samples and composite milk samples were collected twice weekly from 3 to 18 days in milk (DIM) for a total of 4 time points per cow (T1, T2, T3, T4). Blood was analyzed using a hand-held meter, and milk was analyzed using Fourier-transform mid-infrared spectrometry for milk BHB and mpbNEFA concentrations, milk de novo FA rel %, and somatic cell count. Excessive energy deficit was diagnosed as blood BHB ≥ 1.2 mmol/L, milk BHB ≥ 0.14 mmol/L, mpbNEFA ≥ 0.55 mmol/L, or de novo FA ≤ 22.7 rel %, depending on the model. Clinical mastitis cultures were collected from 4 to 60 DIM by on-farm personnel. Incidence of hyperketonemia as determined by blood BHB was 13.4%, and incidence of CM was 23.9%. Separate repeated-measures ANOVA models were developed for each EED diagnostic analyte for parity groups 2, 3, and ≥4 to assess differences in SCS; t-test analyses were similarly used to assess the association of each diagnostic analyte with CM at each time point. For all diagnostic analytes, apart from milk BHB, cows diagnosed with EED tended to have lower SCS than their non-EED counterparts. This was especially apparent at T1 for all parity groups, and at T2, T3, and T4 for blood BHB and mpbNEFA. For EED diagnosis via mpbNEFA, mean SCS were lower in parity ≥4, with a difference in mean SCS between EED and non-EED animals of 0.7 SCS units, equating to a somatic cell count in EED animals approaching half that of non-EED (EED = 67,000 cells/mL, non-EED = 107,000 cell/mL). No important relationships were observed between CM diagnosis and blood BHB, milk BHB, or mpbNEFA. For de novo FA rel %, reductions in this analyte were noted before CM diagnosis at all time points. Although the relationship between EED and CM is still unclear, our findings suggest that cows in EED, diagnosed using blood BHB or mpbNEFA during the first 18 DIM, have a tendency toward lower SCS compared with their non-EED counterparts.


Asunto(s)
Mastitis Bovina/diagnóstico , Leche/citología , Ácido 3-Hidroxibutírico/metabolismo , Animales , Bovinos , Ácidos Grasos/análisis , Ácidos Grasos no Esterificados/metabolismo , Femenino , Incidencia , Cetosis/epidemiología , Cetosis/etiología , Cetosis/veterinaria , Lactancia , Mastitis Bovina/epidemiología , Mastitis Bovina/etiología , New York , Paridad , Embarazo , Estudios Prospectivos , Espectrofotometría Infrarroja/veterinaria
7.
J Dairy Sci ; 104(2): 2185-2194, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33309356

RESUMEN

Our objective was to investigate the effect of i.v. dextrose as an adjunct therapy to oral propylene glycol on the resolution of hyperketonemia (HYK; blood ß-hydroxybutyrate ≥1.2 mmol/L), disease incidence, and early lactation milk yield. Cows (n = 1,249) between 3 and 16 d in milk (DIM) from 4 New York dairy farms were screened once weekly for HYK for 2 wk. Those with HYK and no previous history of retained placenta, metritis, or HYK were randomly assigned to 1 of 3 treatment groups: 300 mL of oral 100% propylene glycol for 3 d (PG3); 300 mL of oral 100% propylene glycol for 3 d plus 500 mL i.v. 50% dextrose on d 1 (PG3D1); or 300 mL of oral 100% propylene glycol for 3 d plus 500 mL i.v. 50% dextrose on all 3 d (PG3D3). Cows with a blood ß-hydroxybutyrate <1.2 mmol/L at initial screening were re-screened the following week and randomly assigned to the above treatment groups if blood ß-hydroxybutyrate was ≥1.2 mmol/L. Cows were assessed for post-treatment HYK resolution 1 and 2 wk after initial HYK diagnosis. We collected farm-diagnosed occurrence of adverse events (sold, died, metritis, displaced abomasum, or ketosis) during the first 60 DIM and milk yield data from the first 10 wk of lactation from herd management software. We used mixed-effects multivariable Poisson regression models to assess the risk of post-treatment HYK resolution at 1 and 2 wk following initial HYK diagnosis and adverse event occurrence among treated cows. We used repeated-measures ANOVA to assess differences in average daily milk yield between treatments. The overall HYK incidence was 30.1% (n = 373). Sixty-four percent of cows (n = 237) were assigned to a treatment group in the first week (3 to 9 DIM), and 36% (n = 136) assigned the second week (10 to 16 DIM). The incidence of 1 or more adverse events during the first 60 DIM was 9.4% (n = 35). We found no effect of treatment on risk of post-treatment HYK resolution at wk 1 (PG3 56.9%, PG3D1 45.0%, PG3D3 50.0%) or wk 2 (PG3 60.0%, PG3D1 52.1%, PG3D3 59.5%) following initial diagnosis, or for risk of adverse event occurrence (PG3 7.4%, PG3D1 8.0%, PG3D3 12.6%). Average daily milk yield (mean ± SE) was similar between treatment groups (PG3: 42.7 ± 0.6 kg/d, PG3D1: 42.4 ± 0.6 kg/d, PG3D3: 42.6 ± 0.6 kg/d). The addition of dextrose for 1 or 3 d provided no improvement in resolution of ketosis assessed once weekly, reduction in adverse events during the first 60 d of lactation, or a difference in average daily milk yield during the first 10 wk of lactation.


Asunto(s)
Enfermedades de los Bovinos/tratamiento farmacológico , Glucosa/uso terapéutico , Cetosis/veterinaria , Propilenglicol/uso terapéutico , Ácido 3-Hidroxibutírico/sangre , Animales , Bovinos , Enfermedades de los Bovinos/sangre , Pruebas Diagnósticas de Rutina , Femenino , Cetosis/tratamiento farmacológico , Lactancia , Leche , New York , Embarazo , Gastropatías/veterinaria
8.
J Dairy Sci ; 104(1): 818-825, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33162068

RESUMEN

Most dairy cows experience a period of energy deficit in early lactation, resulting in increased plasma concentrations of nonesterified fatty acids (NEFA) and ß-hydroxybutyrate (BHB). Our objectives were to determine (1) the diurnal variation in plasma BHB and NEFA, (2) the correlation between plasma NEFA and BHB when accounting for diurnal changes, and (3) the effect of hyperketonemia (HYK) on the diurnal pattern of blood metabolites. Jugular catheters were placed in 28 multiparous Holstein cows between 3 and 9 days in milk, and blood samples were collected every 2 h for 96 h. Cows were retrospectively classified as HYK positive (HYK; n = 13) if they had plasma BHB concentrations ≥1.2 mmol/L for ≥3 study days, or HYK negative (non-HYK; n = 15) if they had plasma BHB concentrations ≥1.2 mmol/L for ≤2 study days. Generalized linear mixed models were used to analyze concentrations of analytes over time and differences in metabolites between HYK groups. The correlation between total plasma NEFA and BHB was analyzed by calculating the area under the curve for plasma NEFA and BHB for all cows. Plasma NEFA reached a peak approximately 2 h before morning feed delivery, falling to a nadir in the late evening. Plasma BHB was at a nadir at the time of morning feed delivery, peaking 4 h later. We observed a strong positive correlation between daily plasma NEFA and BHB. Additionally, HYK cows had greater concentrations of plasma NEFA and BHB than non-HYK cows. The HYK cows also experienced a greater magnitude of change in BHB throughout the day than the non-HYK cows. Our results suggest that the time relative to feeding should be considered when analyzing plasma metabolites, as classification of energy status may change throughout a day.


Asunto(s)
Ácido 3-Hidroxibutírico/sangre , Enfermedades de los Bovinos/sangre , Ritmo Circadiano/fisiología , Ácidos Grasos no Esterificados/sangre , Cetosis/veterinaria , Lactancia/sangre , Animales , Bovinos , Metabolismo Energético/fisiología , Femenino , Cetosis/sangre , Estudios Retrospectivos
9.
J Dairy Sci ; 103(1): 922-928, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31733856

RESUMEN

Our objectives were to examine the stability of (1) serum and plasma total calcium (tCa) after delayed separation of bovine whole blood stored at 4°C, and (2) frozen serum and plasma tCa stored at -80°C. Whole blood was collected from 19 cows into vacutainer tubes (Becton Dickinson, Franklin Lakes, NJ) containing no additives (serum) or lithium heparin (plasma). Baseline tCa concentrations (0-h tCa) were determined on serum and plasma harvested within 2 h of blood collection. To evaluate the effect of prolonged whole blood storage at 4°C, serum and plasma were harvested from samples after 6, 24, 48, 72 h, and 7 and 14 d of storage. For evaluation of the stability of frozen serum and plasma stored at -80°C, samples were stored for 7 d and 1, 3, 6, and 12 mo. The median 0-h tCa concentration for serum and plasma was 2.25 mmol/L (range: 1.58 to 2.60 mmol/L) and 2.28 mmol/L (range: 1.60 to 2.65 mmol/L), respectively. The average difference in tCa from 0-h samples ranged from -0.02 to 0.03 mmol/L for all samples stored at either 4 or -80°C. The median within-cow variability for whole blood samples stored at 4°C was 1.1 and 1.0% for serum and plasma, respectively, and for serum and plasma stored at -80°C was 1.1 and 1.3%, respectively. When whole blood was stored at 4°C, no differences in serum or plasma tCa concentrations were observed across the evaluated time points as compared with 0-h concentrations. Similarly, frozen serum and plasma stored at -80°C remained stable up to 12 mo. Therefore, our findings show that whole blood samples may be stored for at least 14 d at 4°C in vacutainer tubes containing no additives or lithium heparin without biologically important changes in tCa concentrations beyond expected analytical variation. Additionally, serum or plasma may be stored at -80°C for up to 12 mo with no effect on tCa concentrations.


Asunto(s)
Recolección de Muestras de Sangre/veterinaria , Calcio/sangre , Bovinos/sangre , Animales , Pruebas Diagnósticas de Rutina , Femenino , Temperatura
10.
J Dairy Sci ; 102(11): 10129-10139, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31495624

RESUMEN

Partial least squares regression estimates of milk and blood constituents using Fourier-transform mid-infrared (FTIR) analysis have shown promise as a tool for monitoring early-lactation excessive energy deficit in dairy herds. Our objective was to analyze milk via FTIR to determine the association of early-lactation predicted milk ß-hydroxybutyrate (BHB) concentrations, predicted blood nonesterified fatty acid (NEFA) concentrations, and predicted milk de novo fatty acid (FA) percentages relative to total FA concentrations, with the risk of disease or removal in early lactation (hyperketonemia, displaced abomasum, metritis, culling, or death) and average daily milk yield during the first 15 wk of lactation. We enrolled 517 multiparous Holstein cows from 2 dairy farms in New York. Composite milk samples were collected twice weekly from 3 to 18 DIM for a total of 4 timepoints (T1, T2, T3, T4) and analyzed using FTIR spectrometry for milk BHB and FA composition and predicted blood NEFA. Blood samples were collected for hyperketonemia determination (BHB ≥ 1.2 mmol/L) using a handheld meter, and farm-diagnosed occurrence of disease or removal during the first 30 DIM and average daily milk yield during the first 15 wk of lactation were collected from herd management software. The incidence of disease or removal between 3 and 18 DIM was 20.2%. Explanatory models for disease or removal were developed for each predicted constituent of interest at each timepoint using fixed-effect multivariable Poisson regression. Repeated measures ANOVA models were developed for each predicted constituent to assess differences in average daily milk yield. For all timepoints, increased risk of disease or removal was associated with higher predicted milk BHB [relative risk (RR)T1 = 2.0; RRT2 = 3.4; RRT3 = 5.2; RRT4 = 9.1], higher predicted blood NEFA (RRT1 = 2.7; RRT2 = 2.5; RRT3 = 3.8; RRT4 = 10.0), and lower predicted milk de novo FA relative percentages (RRT1 = 2.9; RRT2 = 3.3; RRT3 = 5.8; RRT4 = 7.2). Average daily milk yield was increased for cows above the cut point for predicted milk BHB (2.1 kg/d) and predicted blood NEFA (3.5 kg/d) and below the cut point for de novo FA relative percentages (2.3 kg/d). Our results suggest that FTIR-predicted milk BHB, blood NEFA, and milk de novo FA relative percentages are promising indicators of subsequent disease or removal in early lactation; their positive relationship with milk yield warrants further exploration.


Asunto(s)
Ácido 3-Hidroxibutírico/sangre , Enfermedades de los Bovinos/sangre , Ácidos Grasos no Esterificados/sangre , Leche/química , Espectroscopía Infrarroja por Transformada de Fourier/veterinaria , Animales , Bovinos , Enfermedades de los Bovinos/fisiopatología , Ácidos Grasos/análisis , Femenino , Lactancia , Análisis de los Mínimos Cuadrados , Leche/metabolismo , New York
11.
J Dairy Sci ; 102(5): 4364-4375, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30827556

RESUMEN

Claw horn disruptions in the bovine claw are believed to be a consequence of pressure on the sole corium from the third phalanx, which may be caused by a weakening of the suspensory apparatus in the claw. We aimed to develop an ultrasonographic method that would make it possible to measure the thickness of the soft tissue between the third phalanx and the sole horn on a weight-bearing claw. A device was developed to record the sole horn and soft tissue thickness indirectly through a polyethylene plate, and 52 feet from slaughtered cows were examined using ultrasonography, both directly and indirectly. Soft tissue and sole horn thickness measurements in the apex and the plantar part of the sole were compared with anatomical measurements of transected claws. To assess the method on weight-bearing versus non-weight-bearing claws, we examined the hind claws of 10 live cattle without transection. We found a weak correlation between the soft tissue thickness measured by ultrasound and anatomical measurements. A strong correlation was observed between the direct ultrasound approach and the developed indirect method. There was a considerable difference between weight-bearing and non-weight-bearing claws, signifying a weak or nonexistent correlation. However, this part of the study was only done on 10 live cows and the results should be interpreted with caution. We concluded that it would be possible to measure the soft tissue using an indirect ultrasound approach on a weight-bearing-claw standing on a polyethylene plate. The major difference between the results of weight-bearing versus non-weight-bearing claws suggests that future studies of the suspensory apparatus could focus on weight-bearing claws.


Asunto(s)
Bovinos , Industria Lechera/métodos , Pezuñas y Garras/diagnóstico por imagen , Ultrasonografía/veterinaria , Animales , Bovinos/anatomía & histología , Dermis/anomalías , Femenino , Pezuñas y Garras/anomalías , Pezuñas y Garras/anatomía & histología , Ultrasonografía/instrumentación , Ultrasonografía/métodos , Soporte de Peso
12.
Prev Vet Med ; 163: 51-57, 2019 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-30670186

RESUMEN

Our objective was to evaluate a 200,000 cells/mL somatic cell count (SCC) cut-point on both the quarter and composite level to determine its effectiveness at identifying subclinical mastitis infections in one commercial dairy herd in Central New York. Milk samples from 107 Holstein cows were used for analysis. All cows were eligible for enrollment provided they had 4 working udder quarters, were >14 and <365 d in milk, and had no clinical mastitis event or treatment with intramammary antibiotics ≤14 d prior to d of sampling. A total of 428 quarter and 107 composite samples from 34 primiparous and 73 multiparous animals were analyzed for total SCC and aerobic culture. Performance of SCC for identification of subclinically infected animals was evaluated against the gold standard aerobic culture. Sensitivities for a 200,000 cells/mL cut-point on both the quarter and composite basis were 28.6%, and specificities were 91.5% and 87.3% on the quarter and composite basis, respectively. Receiver operating characteristic (ROC) curves determined on a quarter basis found the cut-point that optimized the sensitivity and specificity of a positive culture was 32,000 cells/mL, with a sensitivity of 76.2%, a specificity of 62.4%, and an area under the curve (AUC) of 0.73. The ROC curve cut-point that optimized the sensitivity and specificity for the composite samples was 75,000 cells/mL, with a sensitivity of 57.1%, a specificity of 78.9%, and an AUC of 0.67. A large proportion of culture positive primiparous cows (38%) had low SCC (median of 101,000 cells/mL on the quarter and 80,000 cells/mL on the composite level), and therefore, when multiparous cows were examined separately, the cut-point that optimized sensitivity and specificity on the quarter basis increased to 645,000 cells/mL with a corresponding sensitivity of 34.8%, specificity of 97.5%, and AUC of 0.65. On the composite basis, the cut-point based on multiparous cows only was 152,000 cells/mL, with a corresponding sensitivity of 60.0%, and specificity of 82.0%, and an AUC of 0.65. Our data indicate that the 200,000 cells/mL cut-point was inefficient in identifying subclinically infected animals, regardless of whether quarter or composite sampling was used. The low prevalence of subclinical infections as well as the large proportion of minor pathogens, especially in primiparous animals, contributed to this inefficiency. This case study provides evidence that, with continued improvement upon mastitis control and reduction in major mastitis pathogens, blanket cut-points may no longer provide the same diagnostic usefulness as they once did.


Asunto(s)
Mastitis Bovina/diagnóstico , Leche/citología , Animales , Infecciones Asintomáticas , Bovinos , Recuento de Células/veterinaria , Industria Lechera , Femenino
13.
J Dairy Sci ; 101(10): 9321-9331, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30077442

RESUMEN

The objectives of this study were to characterize the epidemiology of subclinical hypocalcemia (SCH) in Holstein dairy cows by assessing the temporal associations of plasma Ca concentrations in the first 4 d in milk (DIM) with the risk of cows being diagnosed with metritis or displaced abomasum (or both), and milk production across the first 15 wk of lactation. A prospective cohort study was conducted in 2 dairy herds in New York State, in which cows had a blood sample collected daily for the first 4 DIM. A total of 396 Holstein cows (137 primiparous and 259 multiparous) were enrolled. Multivariable Poisson regression models were built to evaluate the associations of plasma Ca concentration at each of the 4 d following parturition with the risk of primiparous cows being diagnosed with metritis and multiparous cows being diagnosed with metritis, displaced abomasum, or both. Similarly, generalized linear mixed models were built to evaluate the associations of plasma Ca concentration with milk production across the first 15 wk of lactation. Plasma Ca concentration was assessed on a continuous scale in all models; dichotomization and SCH classification only occurred in the final models if the Ca concentration variable was meaningful by creating an optimized threshold based on receiver operating characteristic curve analysis. Plasma Ca concentration assessed at 1 DIM was not associated with the risk of metritis in primiparous cows, but an association was observed at 2, 3, and 4 DIM (critical thresholds were plasma Ca concentration ≤2.15, 2.10, and 2.15 mmol/L, respectively). Plasma Ca concentration was associated with the risk of metritis or displaced abomasum diagnosis (or both) for 2nd parity animals at 2 DIM (threshold ≤1.97 mmol/L), and at 4 DIM for 3rd and greater lactations (threshold ≤2.20 mmol/L). Reduced plasma Ca concentration was associated with higher milk production when assessed at 1 DIM in primiparous and multiparous cows, and lower milk production when assessed at 4 DIM in multiparous cows only. For primiparous cows, plasma Ca concentration was not associated with lower milk production at any of the DIM assessed. In conclusion, assessments of SCH at the individual cow level must take into account the DIM of Ca concentration measurement and parity of the cow, as the epidemiology of the disorder was demonstrated to be highly dependent on these variables. This study advances the knowledge of the epidemiology of SCH and better establishes thresholds for optimizing SCH diagnosis.


Asunto(s)
Calcio/sangre , Enfermedades de los Bovinos/epidemiología , Hipocalcemia/veterinaria , Lactancia/sangre , Animales , Bovinos , Femenino , Hipocalcemia/epidemiología , Leche/metabolismo , Periodo Posparto , Embarazo , Estudios Prospectivos
14.
J Dairy Sci ; 101(2): 1334-1343, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29248221

RESUMEN

The objective of this study was to assess an optimized ion-selective electrode Ca-module prototype as a potential cow-side device for ionized Ca (iCa) measurements in bovine blood. A linearity experiment showed no deviation from linearity over a range of iCa concentrations compared with a commercial point-of-care (POC) device commonly used in the field (POCVS; VetScan i-STAT, Abaxis North America, Union City, CA) and a laboratory gold standard benchtop blood-gas analyzer [reference analyzer (RA); ABL-800 FLEX, Radiometer Medical, Copenhagen, Denmark]. Coefficient of variation on 3 samples with high, within-range, and low iCa concentrations ranged from 1.0 to 3.9% for the prototype. A follow-up validation experiment was performed, in which our objectives were to (1) assess the performance of the prototype cow-side against the POCVS (farm gold-standard) using fresh non-anticoagulated whole-blood samples; (2) assess the performance of the prototype and the POCVS against the RA in a diagnostic laboratory using blood collected in a heparin-balanced syringe; and (3) assess the agreement of the prototype and POCVS on-farm (fresh non-anticoagulated whole blood) against the RA on heparin-balanced blood. Finally, sensitivity and specificity of the results obtained by the prototype and the POCVS cow-side compared with the results obtained by the laboratory RA using 3 different iCa cut points for classification of subclinical hypocalcemia were calculated. A total of 101 periparturient Holstein cows from 3 dairy farms in New York State were used for the second experiment. Ionized Ca results from the prototype cow-side were, on average, 0.06 mmol/L higher than the POCVS. With heparin-balanced samples under laboratory conditions, the prototype and POCVS measured an average 0.04 mmol/L higher and lower, respectively, compared with the RA. Results from the prototype and POCVS cow-side were 0.01 mmol/L higher and 0.05 mmol/L lower, respectively, compared with results from the laboratory RA on heparinized blood. Sensitivity and specificity for the prototype and the POCVS under farm conditions at 3 potential subclinical hypocalcemia cut points were 100 and ≥93.5%, respectively. This novel ion-selective electrode Ca-module could become a rapid low-cost tool for assessing iCa cow-side, while qualitatively allowing classification of subclinical hypocalcemia on-farm.


Asunto(s)
Calcio/sangre , Enfermedades de los Bovinos/diagnóstico , Hipocalcemia/veterinaria , Sistemas de Atención de Punto , Animales , Análisis de los Gases de la Sangre , Bovinos , Enfermedades de los Bovinos/sangre , Femenino , Hipocalcemia/sangre , Hipocalcemia/diagnóstico , Sensibilidad y Especificidad
15.
J Dairy Sci ; 99(11): 9136-9142, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27568045

RESUMEN

The objective of this study was to evaluate 4 handheld ketone meters for use in on-farm ß-hydroxybutyrate (BHB) monitoring of hyperketonemia in transition dairy cows. Blood samples taken from 250 Holstein cows between 262d pregnant and 15d in milk were evaluated on 4 different handheld ketone meters: Precision Xtra (Abbott Laboratories, Abbott Park, IL), TaiDoc (Pharmadoc, Lüdersdorf, Germany), Nova Max (Nova Biomedical, Billerica, MA), and Nova Vet (Nova Biomedical). Samples were screened using the Precision Xtra and tested on the remaining 3 m if the sample BHB concentration fell into predetermined ranges. A total of 89 samples were used for analysis. Performance of each meter was compared with the average of 2 plasma BHB concentrations both determined by a gold standard spectrophotometric Randox assay performed at 2 independent laboratories. Agreement between the 2 laboratories was very strong (Pearson correlation=0.998). All meters had Pearson correlation coefficients greater than 0.95. The Precision Xtra and TaiDoc meters were 100.0% sensitive and 73.5% specific at a BHB concentration cut point of 1.2mmol/L. The Nova Vet and Nova Max meters had sensitivities of 94.9 and 74.4% and specificities of 91.8 and 100.0%, respectively, at the same cut point. Agreement between the gold standard and the handheld meter was the best for the Nova Vet meter when evaluated using a Bland Altman graph with a mean BHB difference of 0.08mmol/L. Trends in bias were noted with the Precision Xtra and Nova Max meters resulting in increasing average discrepancy between the gold standard and the meter for both at higher plasma BHB concentrations and mean BHB differences of -0.34 and 0.26mmol/L, respectively. The coefficient of variation was <10% for the Precision Xtra, TaiDoc, and Nova Vet meters, and <15% for the Nova Max meter. We conclude that the TaiDoc and Nova Vet meters, similar to the already validated Precision Xtra meter, are acceptable for use in on-farm testing for monitoring and treatment of hyperketonemia.


Asunto(s)
Enfermedades de los Bovinos/diagnóstico , Cetosis/veterinaria , Ácido 3-Hidroxibutírico/sangre , Animales , Bovinos , Femenino , Leche , Sensibilidad y Especificidad
16.
Diabetes Metab ; 42(2): 105-11, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26677772

RESUMEN

AIM: The aim of this study was to assess interactions between glucose and iron homoeostasis in the adipose tissue (AT) of obese subjects. METHODS: A total of 46 obese patients eligible for bariatric surgery were recruited into the study. Anthropometric and biochemical characteristics were assessed, and biopsies of subcutaneous (SCAT) and visceral adipose tissue (VAT) performed. The mRNA levels of genes involved in iron and glucose homoeostasis were measured in their AT and compared with a pool of control samples. RESULTS: Gene expression of hepcidin (HAMP) was significantly increased in the SCAT and VAT of obese patients, while transferrin receptor (TFRC) expression was reduced, compared with non-obese controls, suggesting a higher iron load in obese patients. Also, mRNA levels of adiponectin (ADIPOQ) were decreased in both SCAT and VAT in obese patients, and correlated negatively with hepcidin expression, while adiponectin expression was positively correlated with TFRC expression in both SCAT and VAT. Interestingly, TFRC expression in VAT correlated negatively with several metabolic parameters, such as fasting blood glucose and LDL cholesterol. CONCLUSION: Iron content appears to be increased in the SCAT and VAT of obese patients, and negatively correlated with adiponectin expression, which could be contributing to insulin resistance and the metabolic complications of obesity.


Asunto(s)
Adiponectina/metabolismo , Tejido Adiposo/metabolismo , Hierro/sangre , Obesidad Mórbida/metabolismo , Adiponectina/análisis , Adiponectina/genética , Tejido Adiposo/química , Adulto , Femenino , Hepcidinas/análisis , Hepcidinas/genética , Hepcidinas/metabolismo , Humanos , Resistencia a la Insulina , Masculino , Persona de Mediana Edad , Obesidad Mórbida/sangre , Obesidad Mórbida/epidemiología , Estudios Prospectivos
17.
Eur Arch Paediatr Dent ; 17(2): 97-105, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26661271

RESUMEN

AIM: This was to explore the socio-behavioural risk factors for ECC in Cambodia. Early childhood caries (ECC) is a significant health problem in Cambodia. METHODS: A convenience sample of 362 primary caregiver-child dyads were selected. The children were aged between birth and 6 years old and participated in a structured interview and intra-oral examination. RESULTS: ECC was diagnosed in 244 of 362 (65.6%) children and 178 (50.6%) had severe early childhood caries (sECC). There were significant associations between caries experience and tooth brushing, dietary, and nursing habits. The odds ratio (OR) for sECC in those children who started brushing before the age of 18 months was 0.41 (CI 0.18, 0.93). However, for those children who continued to breast-feed after the age of 2 years the OR was 5.31 (CI 1.50, 18.79). CONCLUSIONS: The most prominent risk factors for ECC in the present study were lack of tooth brushing and breast-feeding past the age of 2 years.


Asunto(s)
Lactancia Materna , Caries Dental/epidemiología , Cepillado Dental , Preescolar , Caries Dental/diagnóstico , Dieta , Femenino , Conductas Relacionadas con la Salud , Humanos , Masculino , Proyectos Piloto , Prevalencia , Factores de Riesgo
18.
Life Sci ; 138: 52-6, 2015 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-25534441

RESUMEN

AIMS: Several lines of evidence suggest that the endocannabinoid system is involved in the regulation of glial activity. Enhanced levels of the endocannabinoid N-arachidonoyl ethanolamine (AEA, also referred to as anandamide) as well as non-cannabinoid lipids like palmitoylethanolamine (PEA) due to genetic deletion or pharmacologic blockade of its degrading enzyme fatty acid amide hydrolase (FAAH) reduced neuroinflammatory changes in models of neurodegeneration. Now we addressed the question if genetic deletion of FAAH also influences age-related neuroinflammation. MAIN METHODS: To answer this question we compared the number and size of microglia in young and old wild-type and FAAH(-/-) mice and analysed the distribution of microglia sizes in the four groups. Additionally, we analysed IL-6 and IL-1ß levels with ELISA and astrocyte activities as ratio of GFAP-positive areas in the hippocampus. KEY FINDINGS: Ageing was associated with an increased number and activity of microglia, elevated IL-6 and IL-1ß levels and enhanced area covered by astrocytes in wild-type animals. Unexpectedly, in FAAH(-/-) animals the number of microglia and the ratio of activated microglia and IL-1ß level were already higher in young animals than in age-matched wild-type controls. There was no further age-related increase in these inflammation markers in the knockout line. SIGNIFICANCE: Our results suggest that AEA is involved in the regulation of microglia activity. Life-long elevation of AEA levels disturbs microglial regulation and leads to pro-inflammatory changes.


Asunto(s)
Amidohidrolasas/genética , Amidohidrolasas/fisiología , Microglía/fisiología , Envejecimiento/genética , Envejecimiento/patología , Animales , Astrocitos/metabolismo , Tamaño de la Célula , Citocinas/metabolismo , Genotipo , Proteína Ácida Fibrilar de la Glía/metabolismo , Hipocampo/metabolismo , Hipocampo/patología , Inflamación/genética , Inflamación/patología , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Microglía/ultraestructura
19.
Thorax ; 66(4): 315-9, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21169285

RESUMEN

BACKGROUND: In lung cancer screening the ability to distinguish malignant from benign nodules is a key issue. This study evaluates the ability of positron emission tomography (PET) and volume doubling time (VDT) to discriminate between benign and malignant nodules. METHODS: From the Danish Lung Cancer Screening Trial, participants with indeterminate nodules who were referred for a 3-month rescan were investigated. Resected nodules and indolent nodules (ie, stable for at least 2 years) were included. Between the initial scan and the 3-month rescan, participants were referred for PET. Uptake on PET was categorised as most likely benign to malignant (grades I-IV). VDT was calculated from volume measurements on repeated CT scans using semiautomated pulmonary nodule evaluation software. Receiver operating characteristic (ROC) analyses were used to determine the sensitivity and specificity of PET and VDT. RESULTS: A total of 54 nodules were included. The prevalence of lung cancer was 37%. In the multivariate model both PET (OR 2.63, p<0.01) and VDT (OR 2.69, p<0.01) were associated with lung cancer. The sensitivities and specificities of both PET and VDT were 71% and 91%, respectively. Cut-off points for malignancy were PET>II and VDT<1 year, respectively. Combining PET and VDT resulted in a sensitivity of 90% and a specificity of 82%; ROC cut-off point was either PET or VDT indicating malignancy. CONCLUSION: PET and VDT predict lung cancer independently of each other. The use of both PET and VDT in combination is recommended when screening for lung cancer with low-dose CT.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Anciano , Diagnóstico Diferencial , Progresión de la Enfermedad , Detección Precoz del Cáncer/métodos , Métodos Epidemiológicos , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones/métodos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos
20.
Eur Radiol ; 20(8): 1878-85, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20306082

RESUMEN

OBJECTIVE: We examined the reproducibility of lung nodule volumetry software that offers three different volumetry algorithms. METHODS: In a lung cancer screening trial, 188 baseline nodules >5 mm were identified. Including follow-ups, these nodules formed a study-set of 545 nodules. Nodules were independently double read by two readers using commercially available volumetry software. The software offers readers three different analysing algorithms. We compared the inter-observer variability of nodule volumetry when the readers used the same and different algorithms. RESULTS: Both readers were able to correctly segment and measure 72% of nodules. In 80% of these cases, the readers chose the same algorithm. When readers used the same algorithm, exactly the same volume was measured in 50% of readings and a difference of >25% was observed in 4%. When the readers used different algorithms, 83% of measurements showed a difference of >25%. CONCLUSION: Modern volumetric software failed to correctly segment a high number of screen detected nodules. While choosing a different algorithm can yield better segmentation of a lung nodule, reproducibility of volumetric measurements deteriorates substantially when different algorithms were used. It is crucial even in the same software package to choose identical parameters for follow-up.


Asunto(s)
Algoritmos , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Validación de Programas de Computación , Programas Informáticos , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...