Cardiology ; 148(6): 556-570, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37442111

RESUMEN

BACKGROUND: Elderly patients with aortic stenosis (AS) not only have a reduced life expectancy but also a reduced quality of life (QoL). The benefits of an AS intervention may be considered a balance between a good QoL and a reasonably extended life. However, the different questionnaires being used to determine the QoL were generally not developed for the specific situation of patients with AS and come with strengths and considerable weaknesses. The objective of this article was to provide an overview of the available QoL instruments in AS research, describe their strengths and weaknesses, and provide our assessment of the utility of the available scoring instruments for QoL measurements in AS. SUMMARY: We identified and reviewed the following instruments that are used in AS research: Short Form Health Survey (SF-36/SF-12), EuroQol-5D (EQ-5D), the Illness Intrusiveness Rating Scale (IIRS), the HeartQoL, the Kansas City Cardiomyopathy Questionnaire (KCCQ), the Minnesota Living with Heart Failure Questionnaire (MLHF), the MacNew Questionnaire, and the Toronto Aortic Stenosis Quality of Life Questionnaire (TASQ). KEY MESSAGES: There is no standardized assessment of QoL in patients with AS. Many different questionnaires are being used, but they are rarely specific for AS. There is a need for AS-specific research into the QoL of patients as life prolongation may compete for an improved QoL in this elderly patient group.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Humanos , Anciano , Calidad de Vida , Encuestas y Cuestionarios
2.
Int J Cardiol ; 364: 31-34, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35700856

RESUMEN

BACKGROUND: Para-valvular regurgitation (PVR) after transcatheter aortic valve (TAV) implantation is associated with increased mortality. Redo-TAVI may be applied to treat PVR, yet with unknown efficacy. We thought to assess redo-TAVI efficacy in reducing PVR using the Redo-TAVI registry (45 centers; 600 TAV-in-TAV cases). METHODS: Patients were excluded if redo-TAVI was done urgently (N = 253), for isolated TAV stenosis (N = 107) or if regurgitation location at presentation remained undetermined (N = 123). The study group of patients with PVR (N = 70) were compared against patients with intra-valvular regurgitation (IVR) (N = 41). Echocardiographic examinations of 67 (60%) patients were reassessed in a core-lab for data accuracy validation. RESULTS: Core-lab examination validated the jet location in 66 (98.5%) patients. At 30 days, the rate of residual AR ≥ moderate was 7 (10%) in the PVR cohort vs. 1 (2.4%) in the IVR cohort, p = 0.137. The rate of procedural success was 53 (75.7%) vs. 33 (80.5%), p = 0.561; procedural safety 51 (72.8%) vs. 31 (75.6%), p = 0.727; and mortality 2 (2.9%) vs. 1 (2.4%), p = 0.896 at 30 days and 7 (18.6%) vs. 2 (11.5%), p = 0.671 at 1 year, respectively. Of patients with residual PVR ≥ moderate at 30 days, 5/7 occurred after implanting balloon-expandable in self-expanding TAV and 2/7 after balloon-expandable in balloon-expandable TAV. CONCLUSIONS: This study puts in perspective redo-TAVI efficacy and limitations to treat PVR after TAVI. Patient selection for this and other therapies for PVR needs further investigation.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Enfermedades de las Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Enfermedades de las Válvulas Cardíacas/cirugía , Humanos , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
Circ., cariovasc. interv. (Print) ; 14(6): 010440, June. 2021. graf, ilus, tab
Artículo en Inglés | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1352656

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has determined a paradigm shift in the treatment of patients with severe aortic stenosis. However, the durability of bio prostheses is still a matter of concern, and little is known about the management of degenerated TAV. We sought to evaluate the outcomes of patients with a degenerated TAV treated by means of a second TAVR. METHODS: The TRANSIT is an international registry that included cases of degenerated TAVR from 28 centers. Among around 40 000 patients treated with TAVR in the participating centers, 172 underwent a second TAVR: 57 (33%) for a mainly stenotic degenerated TAV, 97 (56%) for a mainly regurgitant TAV, and 18 (11%) for a combined degeneration. Overall, the rate of New York Heart Association class III/IV at presentation was 73.5%. RESULTS: Valve Academic Research Consortium 2 device success rate was 79%, as a consequence of residual gradient (14%) or regurgitation (7%). At 1 month, the overall mortality rate was 2.9%, while rates of new hospitalization and New York Heart Association class III/IV were 3.6% and 7%, respectively, without significant difference across the groups. At 1 year, the overall mortality rate was 10%, while rates of new hospitalization and New York Heart Association class III/IV were 7.6% and 5.8%, respectively, without significant difference across the groups. No cases of valve thrombosis were recorded. CONCLUSIONS: Selected patients with a degenerated TAV may be safely and successfully treated by means of a second TAVR. This finding is of crucial importance for the adoption of the TAVR technology in a lower risk and younger population.