Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38426638

RESUMEN

Alzheimer's disease is the most common cause of dementia and a leading cause of mortality in the elderly population. Diagnosis of Alzheimer's disease has traditionally relied on evaluation of clinical symptoms for cognitive impairment with a definitive diagnosis requiring post-mortem demonstration of neuropathology. However, advances in disease pathogenesis have revealed that patients exhibit Alzheimer's disease pathology several decades before the manifestation of clinical symptoms. Magnetic resonance imaging (MRI) plays an important role in the management of patients with Alzheimer's disease. The clinical availability of molecular MRI (mMRI) contrast agents can revolutionize the diagnosis of Alzheimer's disease. In this article, we review advances in nanoparticle contrast agents, also referred to as nanoprobes, for mMRI of Alzheimer's disease. This article is categorized under: Diagnostic Tools > In Vivo Nanodiagnostics and Imaging Therapeutic Approaches and Drug Discovery > Nanomedicine for Neurological Disease.


Asunto(s)
Enfermedad de Alzheimer , Disfunción Cognitiva , Humanos , Anciano , Enfermedad de Alzheimer/diagnóstico por imagen , Medios de Contraste , Tomografía de Emisión de Positrones/métodos , Disfunción Cognitiva/patología , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/patología
2.
J Hepatol ; 80(4): 610-621, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38242326

RESUMEN

BACKGROUND & AIMS: Patients with metastatic, treatment-refractory, and relapsed hepatoblastoma (HB) have survival rates of less than 50% due to limited treatment options. To develop new therapeutic strategies for these patients, our laboratory has developed a preclinical testing pipeline. Given that histone deacetylase (HDAC) inhibition has been proposed for HB, we hypothesized that we could find an effective combination treatment strategy utilizing HDAC inhibition. METHODS: RNA sequencing, microarray, NanoString, and immunohistochemistry data of patient HB samples were analyzed for HDAC class expression. Patient-derived spheroids (PDSp) were used to screen combination chemotherapy with an HDAC inhibitor, panobinostat. Patient-derived xenograft (PDX) mouse models were developed and treated with the combination therapy that showed the highest efficacy in the PDSp drug screen. RESULTS: HDAC RNA and protein expression were elevated in HB tumors compared to normal livers. Panobinostat (IC50 of 0.013-0.059 µM) showed strong in vitro effects and was associated with lower cell viability than other HDAC inhibitors. PDSp demonstrated the highest level of cell death with combination treatment of vincristine/irinotecan/panobinostat (VIP). All four models responded to VIP therapy with a decrease in tumor size compared to placebo. After 6 weeks of treatment, two models demonstrated necrotic cell death, with lower Ki67 expression, decreased serum alpha fetoprotein and reduced tumor burden compared to paired VI- and placebo-treated groups. CONCLUSIONS: Utilizing a preclinical HB pipeline, we demonstrate that panobinostat in combination with VI chemotherapy can induce an effective tumor response in models developed from patients with high-risk, relapsed, and treatment-refractory HB. IMPACT AND IMPLICATIONS: Patients with treatment-refractory hepatoblastoma have limited treatment options with survival rates of less than 50%. Our manuscript demonstrates that combination therapy with vincristine, irinotecan, and panobinostat reduces the size of high-risk, relapsed, and treatment-refractory tumors. With this work we provide preclinical evidence to support utilizing this combination therapy as an arm in future clinical trials.


Asunto(s)
Hepatoblastoma , Neoplasias Hepáticas , Humanos , Ratones , Animales , Panobinostat/farmacología , Panobinostat/uso terapéutico , Hepatoblastoma/tratamiento farmacológico , Irinotecán/uso terapéutico , Vincristina/uso terapéutico , Recurrencia Local de Neoplasia/tratamiento farmacológico , Recurrencia Local de Neoplasia/inducido químicamente , Inhibidores de Histona Desacetilasas/uso terapéutico , Neoplasias Hepáticas/patología , Ácidos Hidroxámicos/farmacología
3.
Bioeng Transl Med ; 8(6): e10594, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38023719

RESUMEN

Immune checkpoint inhibitors (ICI), pembrolizumab and atezolizumab, were recently approved for treatment-refractory triple-negative breast cancer (TNBC), where those with Programmed death-ligand 1 (PD-L1) positive early-stage disease had improved responses. ICIs are administered systemically in the clinic, however, reaching effective therapeutic dosing is challenging due to severe off-tumor toxicities. As such, intratumoral (IT) injection is increasingly investigated as an alternative delivery approach. However, repeated administration, which sometimes is invasive, is required due to rapid drug clearance from the tumor caused by increased interstitial fluid pressure. To minimize off-target drug biodistribution, we developed the nanofluidic drug-eluting seed (NDES) platform for sustained intratumoral release of therapeutic via molecular diffusion. Here we compared drug biodistribution between the NDES, intraperitoneal (IP) and intratumoral (IT) injection using fluorescently labeled PD-L1 monoclonal antibody (αPD-L1). We used two syngeneic TNBC murine models, EMT6 and 4T1, that differ in PD-L1 expression, immunogenicity, and transport phenotype. We investigated on-target (tumor) and off-target distribution using different treatment approaches. As radiotherapy is increasingly used in combination with immunotherapy, we sought to investigate its effect on αPD-L1 tumor accumulation and systemic distribution. The NDES-treated cohort displayed sustained levels of αPD-L1 in the tumor over the study period of 14 days with significantly lower off-target organ distribution, compared to the IP or IT injection. However, we observed differences in the biodistribution of αPD-L1 across tumor models and with radiation pretreatment. Thus, we sought to extensively characterize the tumor properties via histological analysis, diffusion evaluation and nanoparticles contrast-enhanced CT. Overall, we demonstrate that ICI delivery via NDES is an effective method for sustained on-target tumor delivery across tumor models and combination treatments.

4.
medRxiv ; 2023 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-36993653

RESUMEN

Introduction: Placenta accreta spectrum (PAS) occurs when the placenta is pathologically adherent to the myometrium. An intact retroplacental clear space (RPCS) is a marker of normal placentation, but visualization with conventional imaging techniques is a challenge. In this study, we investigate use of an FDA-approved iron oxide nanoparticle, ferumoxytol, for contrast-enhanced magnetic resonance imaging of the RPCS in mouse models of normal pregnancy and PAS. We then demonstrate the translational potential of this technique in human patients presenting with severe PAS (FIGO Grade 3C), moderate PAS (FIGO Grade 1), and no PAS. Methods: A T1-weighted gradient recalled echo (GRE) sequence was used to determine the optimal dose of ferumoxytol in pregnant mice. Pregnant Gab3 -/- mice, which demonstrate placental invasion, were then imaged at day 16 of gestation alongside wild-type (WT) pregnant mice which do not demonstrate invasion. Signal-to-noise ratio (SNR) was computed for placenta and RPCS for all fetoplacental units (FPUs) with ferumoxytol-enhanced magnetic resonance imaging (Fe-MRI) and used for the determination of contrast-to-noise ratio (CNR). Fe-MRI was also performed in 3 pregnant subjects using standard T1 and T2 weighted sequences and a 3D magnetic resonance angiography (MRA) sequence. RPCS volume and relative signal were calculated in all three subjects. Results: Ferumoxytol administered at 5 mg/kg produced strong T1 shortening in blood and led to strong placental enhancement in Fe-MRI images. Gab3 -/- mice demonstrated loss of hypointense region characteristic of the RPCS relative to WT mice in T1w Fe-MRI. CNR between RPCS and placenta was lower in FPUs of Gab3 -/- mice compared to WT mice, indicating higher degrees of vascularization and interruptions throughout the space. In human patients, Fe-MRI at a dose of 5 mg/kg enabled high uteroplacental vasculature signal and quantification of the volume and signal profile in severe and moderate invasion of the placenta relative to a non-PAS case. Discussion: Ferumoxytol, an FDA-approved iron oxide nanoparticle formulation, enabled visualization of abnormal vascularization and loss of uteroplacental interface in a murine model of PAS. The potential of this non-invasive visualization technique was then further demonstrated in human subjects. Diagnosis of placental invasion using Fe-MRI may provide a sensitive method for clinical detection of PAS.

5.
Adv Sci (Weinh) ; 10(10): e2206435, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36721029

RESUMEN

The first line of treatment for most solid tumors is surgical resection of the primary tumor with adequate negative margins. Incomplete tumor resections with positive margins account for over 75% of local recurrences and the development of distant metastases. In cases of oral cavity squamous cell carcinoma (OSCC), the rate of successful tumor removal with adequate margins is just 50-75%. Advanced real-time imaging methods that improve the detection of tumor margins can help improve success rates,overall safety, and reduce the cost. Fluorescence imaging in the second near-infrared (NIR-II) window has the potential to revolutionize the field due to its high spatial resolution, low background signal, and deep tissue penetration properties, but NIR-II dyes with adequate in vivo performance and safety profiles are scarce. A novel NIR-II fluorophore, XW-03-66, with a fluorescence quantum yield (QY) of 6.0% in aqueous media is reported. XW-03-66 self-assembles into nanoparticles (≈80 nm) and has a systemic circulation half-life (t1/2 ) of 11.3 h. In mouse models of human papillomavirus (HPV)+ and HPV- OSCC, XW-03-66 outperformed indocyanine green (ICG), a clinically available NIR dye, and enabled intraoperative NIR-II image-guided resection of the tumor and adjacent draining lymph node with negative margins. In vitro and in vivo toxicity assessments revealed minimal safety concerns for in vivo applications.


Asunto(s)
Neoplasias de la Boca , Infecciones por Papillomavirus , Ratones , Animales , Humanos , Espectroscopía Infrarroja Corta/métodos , Verde de Indocianina , Colorantes Fluorescentes/química , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/cirugía
6.
Acad Radiol ; 30(7): 1384-1391, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36167627

RESUMEN

INTRODUCTION: Prior preclinical studies established the utility of liposomal nanoparticle blood-pool contrast agents in visualizing the retroplacental clear space (RPCS), a marker of normal placentation, while sparing fetuses from exposure because the agent does not cross the placental barrier. In this work, we characterized RPCS disruption in a mouse model of placenta accreta spectrum (PAS) using these agents. MATERIALS AND METHODS: Contrast-enhanced MRI (CE-MRI) and computed tomography (CE-CT) using liposomal nanoparticles bearing gadolinium (liposomal-Gd) and iodine were performed in pregnant Gab3-/- and wild type (WT) mice at day 16 of gestation. CE-MRI was performed on a 1T scanner using a 2D T1-weighted sequence (100×100×600 µm3 voxels) and CE-CT was performed at a higher resolution (70×70×70 µm3 voxels). Animals were euthanized post-imaging and feto-placental units (FPUs) were harvested for histological examination. RPCS conspicuity was scored through blinded assessment of images. RESULTS: Pregnant Gab3-/- mice showed elevated rates of complicated pregnancy. Contrast-enhanced imaging demonstrated frank infiltration of the RPCS of Gab3-/- FPUs. RPCS in Gab3-/- FPUs was smaller in volume, demonstrated a heterogeneous signal profile, and received lower conspicuity scores than WT FPUs. Histology confirmed in vivo findings and demonstrated staining consistent with a thinner RPCS in Gab3-/- FPUs. DISCUSSION: Imaging of the Gab3-/- mouse model at late gestation with liposomal contrast agents enabled in vivo characterization of morphological differences in the RPCS that could cause the observed pregnancy complications. An MRI-based method for visualizing the RPCS would be valuable for early detection of invasive placentation.


Asunto(s)
Nanopartículas , Placenta , Femenino , Embarazo , Animales , Ratones , Placenta/diagnóstico por imagen , Medios de Contraste , Imagen por Resonancia Magnética , Modelos Animales de Enfermedad , Estudios Retrospectivos , Proteínas Adaptadoras Transductoras de Señales
7.
Sci Rep ; 10(1): 16185, 2020 09 30.
Artículo en Inglés | MEDLINE | ID: mdl-32999398

RESUMEN

In these preclinical studies, we describe ADx-001, an Aß-targeted liposomal macrocyclic gadolinium (Gd) imaging agent, for MRI of amyloid plaques. The targeting moiety is a novel lipid-PEG conjugated styryl-pyrimidine. An MRI-based contrast agent such as ADx-001 is attractive because of the lack of radioactivity, ease of distribution, long shelf life, and the prevalence of MRI scanners. Dose-ranging efficacy studies were performed on a 1 T MRI scanner using a transgenic APP/PSEN1 mouse model of Alzheimer's disease. ADx-001 was tested at 0.10, 0.15, and 0.20 mmol Gd/kg. Gold standard post-mortem amyloid immunostaining was used for the determination of sensitivity and specificity. ADx-001 toxicity was evaluated in rats and monkeys at doses up to 0.30 mmol Gd/kg. ADx-001 pharmacokinetics were determined in monkeys and its tissue distribution was evaluated in rats. ADx-001-enhanced MRI demonstrated significantly higher (p < 0.05) brain signal enhancement in transgenic mice relative to wild type mice at all dose levels. ADx-001 demonstrated high sensitivity at 0.20 and 0.15 mmol Gd/kg and excellent specificity at all dose levels for in vivo imaging of ß amyloid plaques. ADx-001 was well tolerated in rats and monkeys and exhibited the slow clearance from circulation and tissue biodistribution typical of PEGylated nanoparticles.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Amiloide/metabolismo , Medios de Contraste/administración & dosificación , Imagen por Resonancia Magnética/métodos , Placa Amiloide/diagnóstico por imagen , Enfermedad de Alzheimer/genética , Enfermedad de Alzheimer/metabolismo , Precursor de Proteína beta-Amiloide/genética , Animales , Medios de Contraste/farmacocinética , Modelos Animales de Enfermedad , Relación Dosis-Respuesta a Droga , Humanos , Macaca fascicularis , Masculino , Ratones , Ratones Transgénicos , Fragmentos de Péptidos/metabolismo , Placa Amiloide/genética , Placa Amiloide/metabolismo , Presenilina-1/genética , Ratas , Distribución Tisular
8.
Sci Rep ; 9(1): 18707, 2019 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-31822711

RESUMEN

Non-invasive methods for estimating placental fractional blood volume (FBV) are of great interest for characterization of vascular perfusion in placentae during pregnancy to identify placental insufficiency that may be indicative of local ischemia or fetal growth restriction (FGR). Nanoparticle contrast-enhanced magnetic resonance imaging (CE-MRI) may enable direct placental FBV estimation and may provide a reliable, 3D alternative to assess maternal-side placental perfusion. In this pre-clinical study, we investigated if placental FBV at 14, 16, and 18 days of gestation could be estimated through contrast-enhanced MRI using a long circulating blood-pool liposomal gadolinium contrast agent that does not penetrate the placental barrier. Placental FBV estimates of 0.47 ± 0.06 (E14.5), 0.50 ± 0.04 (E16.5), and 0.52 ± 0.04 (E18.5) were found through fitting pre-contrast and post-contrast T1 values in placental tissue using a variable flip angle method. MRI-derived placental FBV was validated against nanoparticle contrast-enhanced computed tomography (CE-CT) derived placental FBV, where signal is directly proportional to the concentration of iodine contrast agent. The results demonstrate successful estimation of the placental FBV, with values statistically indistinguishable from the CT derived values.


Asunto(s)
Medios de Contraste/metabolismo , Placenta/irrigación sanguínea , Placenta/diagnóstico por imagen , Animales , Volumen Sanguíneo , Femenino , Gadolinio , Liposomas , Imagen por Resonancia Magnética/métodos , Ratones , Ratones Endogámicos C57BL , Nanopartículas , Placenta/metabolismo , Embarazo
9.
Placenta ; 77: 1-7, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30827350

RESUMEN

INTRODUCTION: Visualization of the retroplacental clear space (RPCS) may provide critical insight into the development of abnormally invasive placenta (AIP). In this pre-clinical study, we characterized the appearance of the RPCS on magnetic resonance imaging (MRI) during the second half of gestation using a liposomal gadolinium contrast agent (liposomal-Gd). MATERIALS AND METHODS: Studies were performed in fifteen pregnant C57BL/6 mice at 10, 12, 14, 16, and 18 days of gestation. MRI was performed on a 1T permanent magnet scanner. Pre-contrast and post-contrast images were acquired using T1-weighted gradient-recalled echo (T1w-GRE) and T2-weighted fast spin echo (T2w-FSE) sequences. Animals were euthanized after imaging and feto-placental units harvested for histological examination. Visualization of the RPCS was scored by a maternal-fetal radiologist and quantified by measuring the contrast-to-noise ratio (CNR) on T1w images. Feto-placental features were segmented for analysis of volumetric changes during gestation. RESULTS: Contrast-enhanced T1w images enabled the visualization of structural changes in placental development between days 10-18 of gestation. Although the placental margin on the fetal side was clearly visible at all time points, the RPCS was partially visible at day 10 of gestation, and clearly visible by day 12. Hematoxylin and eosin (H&E) staining of the placental tissue corroborated MRI findings of structural and morphological changes in the placenta. CONCLUSIONS: Contrast-enhanced MR imaging using liposomal-Gd enabled adequate visualization of the retroplacental clear space starting at day 12 of gestation. The agent also enabled characterization of placental structure and morphological changes through gestation.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Placenta/diagnóstico por imagen , Animales , Medios de Contraste , Femenino , Gadolinio , Edad Gestacional , Liposomas , Ratones , Ratones Endogámicos C57BL , Modelos Animales , Placenta/anatomía & histología , Placentación , Embarazo
10.
Contrast Media Mol Imaging ; 2018: 1693513, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30538612

RESUMEN

Fluorine-19 (19F) magnetic resonance imaging (MRI) has the potential for a wide range of in vivo applications but is limited by lack of flexibility in exogenous probe formulation. Most 19F MRI probes are composed of perfluorocarbons (PFCs) or perfluoropolyethers (PFPEs) with intrinsic properties which limit formulation options. Hydrophilic organofluorine molecules can provide more flexibility in formulation options. We report herein a hyperfluorinated hydrophilic organoflourine, ET1084, with ∼24 wt. % 19F content. It dissolves in water and aqueous buffers to give solutions with ≥8 M 19F. 19F MRI phantom studies at 9.4T employing a 10-minute multislice multiecho (MSME) scan sequence show a linear increase in signal-to-noise ratio (SNR) with increasing concentrations of the molecule and a detection limit of 5 mM. Preliminary cytotoxicity and genotoxicity assessments suggest it is safe at concentrations of up to 20 mM.


Asunto(s)
Medios de Contraste/química , Flúor , Fluorocarburos/química , Imagen por Resonancia Magnética/métodos , Medios de Contraste/toxicidad , Fluorocarburos/toxicidad , Interacciones Hidrofóbicas e Hidrofílicas , Límite de Detección , Fantasmas de Imagen , Relación Señal-Ruido , Solubilidad
11.
J Biomech ; 73: 40-49, 2018 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-29580689

RESUMEN

The objective of this study was to characterize the relationships between motion in the scalp, skull, and brain. In vivo estimates of motion transmission from the skull to the brain may illuminate the mechanics of traumatic brain injury. Because of challenges in directly sensing skull motion, it is useful to know how well motion of soft tissue of the head, i.e., the scalp, can approximate skull motion or predict brain tissue deformation. In this study, motion of the scalp and brain were measured using magnetic resonance elastography (MRE) and separated into components due to rigid-body displacement and dynamic deformation. Displacement estimates in the scalp were calculated using low motion-encoding gradient strength in order to reduce "phase wrapping" (an ambiguity in displacement estimates caused by the 2 π-periodicity of MRE phase contrast). MRE estimates of scalp and brain motion were compared to skull motion estimated from three tri-axial accelerometers. Comparison of the relative amplitudes and phases of harmonic motion in the scalp, skull, and brain of six human subjects indicate that data from scalp-based sensors should be used with caution to estimate skull kinematics, but that fairly consistent relationships exist between scalp, skull, and brain motion. In addition, the measured amplitude and phase relationships of scalp, skull, and brain can be used to evaluate and improve mathematical models of head biomechanics.


Asunto(s)
Encéfalo/fisiología , Diagnóstico por Imagen de Elasticidad , Movimiento , Cuero Cabelludo/fisiología , Cráneo/fisiología , Adulto , Fenómenos Biomecánicos , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Masculino , Cuero Cabelludo/diagnóstico por imagen , Cráneo/diagnóstico por imagen
12.
J Biomech ; 69: 10-18, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29395225

RESUMEN

The mechanical properties of brain tissue in vivo determine the response of the brain to rapid skull acceleration. These properties are thus of great interest to the developers of mathematical models of traumatic brain injury (TBI) or neurosurgical simulations. Animal models provide valuable insight that can improve TBI modeling. In this study we compare estimates of mechanical properties of the Yucatan mini-pig brain in vivo and ex vivo using magnetic resonance elastography (MRE) at multiple frequencies. MRE allows estimations of properties in soft tissue, either in vivo or ex vivo, by imaging harmonic shear wave propagation. Most direct measurements of brain mechanical properties have been performed using samples of brain tissue ex vivo. It has been observed that direct estimates of brain mechanical properties depend on the frequency and amplitude of loading, as well as the time post-mortem and condition of the sample. Using MRE in the same animals at overlapping frequencies, we observe that porcine brain tissue in vivo appears stiffer than porcine brain tissue samples ex vivo at frequencies of 100 Hz and 125 Hz, but measurements show closer agreement at lower frequencies.


Asunto(s)
Encéfalo/diagnóstico por imagen , Diagnóstico por Imagen de Elasticidad , Imagen por Resonancia Magnética , Fenómenos Mecánicos , Porcinos , Animales , Fenómenos Biomecánicos , Modelos Teóricos , Porcinos Enanos
13.
J Biomech Eng ; 139(5)2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28267188

RESUMEN

In traumatic brain injury (TBI), membranes such as the dura mater, arachnoid mater, and pia mater play a vital role in transmitting motion from the skull to brain tissue. Magnetic resonance elastography (MRE) is an imaging technique developed for noninvasive estimation of soft tissue material parameters. In MRE, dynamic deformation of brain tissue is induced by skull vibrations during magnetic resonance imaging (MRI); however, skull motion and its mode of transmission to the brain remain largely uncharacterized. In this study, displacements of points in the skull, reconstructed using data from an array of MRI-safe accelerometers, were compared to displacements of neighboring material points in brain tissue, estimated from MRE measurements. Comparison of the relative amplitudes, directions, and temporal phases of harmonic motion in the skulls and brains of six human subjects shows that the skull-brain interface significantly attenuates and delays transmission of motion from skull to brain. In contrast, in a cylindrical gelatin "phantom," displacements of the rigid case (reconstructed from accelerometer data) were transmitted to the gelatin inside (estimated from MRE data) with little attenuation or phase lag. This quantitative characterization of the skull-brain interface will be valuable in the parameterization and validation of computer models of TBI.


Asunto(s)
Encéfalo/citología , Diagnóstico por Imagen de Elasticidad , Cráneo/fisiología , Fenómenos Biomecánicos , Encéfalo/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Movimiento , Fantasmas de Imagen , Cráneo/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...