Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nanomaterials (Basel) ; 14(1)2023 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-38202495

RESUMEN

To generate a stable and effective air-liquid discharge in an open atmosphere, we investigated the effect of the dielectric barrier on the discharge between the pin electrode and liquid surface in an atmospheric-pressure plasma reactor. The atmospheric-pressure plasma reactor used in this study was based on a pin-plate discharge structure, and a metal wire was used as a pin-type power electrode. A plate-type ground electrode was placed above and below the vessel to compare the pin-liquid discharge and pin-liquid barrier discharge (PLBD). The results indicated that the PLBD configuration utilizing the bottom of the vessel as a dielectric barrier outperformed the pin-liquid setup in terms of the discharge stability and that the concentration of reactive species was different in the two plasma modes. PLBD can be used as a digestion technique for determining the phosphorus concentration in natural water sources. The method for decomposing phosphorus compounds by employing PLBD exhibited excellent decomposition performance, similar to the performance of thermochemical digestion-an established conventional method for phosphorus detection in water. The PLBD structure can replace the conventional chemical-agent-based digestion method for determining the total dissolved phosphorus concentration using the ascorbic acid reduction method.

2.
Polymers (Basel) ; 14(22)2022 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-36433044

RESUMEN

In this study, we describe an atmospheric pressure plasma jet (APPJ) device made of four-bore tubing operable in inhospitable humid environments and introduce two potential applications of liquid material processing: decomposition of aqueous phosphorus compounds and solution-plasma polymerization. A four-bore tube was used as the plasma transfer conduit and two diagonal bores contained metal wires. In the proposed APPJ device, the metal wires serving as electrodes are completely enclosed inside the holes of the multi-bore glass tube. This feature allows the APPJ device to operate both safely and reliably in humid environments or even underwater. Thus, we demonstrate that the proposed electrode-embedded APPJ device can effectively decompose aqueous phosphorus compounds into their phosphate form by directly processing the solution sample. As another application of the proposed APPJ device, we also present the successful synthesis of polypyrrole nanoparticles by solution plasma polymerization in liquid pyrrole.

3.
Materials (Basel) ; 14(24)2021 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-34947158

RESUMEN

Here, we proposed a pin-to-liquid dielectric barrier discharge (DBD) structure that used a water-containing vessel body as a dielectric barrier for the stable and effective treatment of aqueous solutions in an open atmosphere. To obtain an intense pin-to-liquid alternating current discharge using a dielectric barrier, discharge characteristics, including the area and shape of a ground-plate-type electrode, were investigated after filling the vessel with equivalent amounts of water. Consequently, as the area of the ground electrode increased, the discharge current became stronger, and its timing became faster. Moreover, we proposed that the pin-to-liquid DBD reactor could be used to decompose phosphorus compounds in water in the form of phosphate as a promising pretreatment method for monitoring total phosphorus in water. The decomposition of phosphorus compounds using the pin-to-liquid DBD reactor demonstrated excellent performance-comparable to the thermochemical pretreatment method-which could be a standard pretreatment method for decomposing phosphorus compounds in water.

4.
Polymers (Basel) ; 13(11)2021 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-34071654

RESUMEN

New nanostructured conducting porous polythiophene (PTh) films are directly deposited on substrates at room temperature (RT) by novel atmospheric pressure plasma jets (APPJs) polymerization technique. The proposed plasma polymerization synthesis technique can grow the PTh films with a very fast deposition rate of about 7.0 µm·min-1 by improving the sufficient nucleation and fragment of the thiophene monomer. This study also compares pure and iodine (I2)-doped PTh films to demonstrate the effects of I2 doping. To check the feasibility as a sensing material, NO2-sensing properties of the I2-doped PTh films-based gas sensors are also investigated. As a result, the proposed APPJs device can produce the high density, porous and ultra-fast polymer films, and polymers-based gas sensors have high sensitivity to NO2 at RT. Our approach enabled a series of processes from synthesis of sensing materials to fabrication of gas sensors to be carried out simultaneously.

5.
Materials (Basel) ; 14(5)2021 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-33800238

RESUMEN

The use of low-voltage-driven plasma in atmospheric pressure (AP) plasma polymerization is considered as a simple approach to reducing the reactivity of the monomer fragments in order to prevent excessive cross-linking, which would have a negative effect on the structural properties of the polymerized thin films. In this study, AP-plasma polymerization can be processed at low voltage by an AP-plasma reactor with a wire electrode configuration. A bare tungsten wire is used as a powered electrode to initiate discharge in the plasma area (defined as the area between the wide glass tube and the substrate stand), thus allowing plasma polymerization to proceed at a lower voltage compared to other AP-plasma reactors with dielectric barriers. Thus, transparent polyaniline (PANI) films are successfully synthesized. The surface morphology, roughness, and film thickness of the PANI films are characterized by field emission scanning electron microscopy and atomic force microscopy. Thus, the surface of the polymerized film is shown to be homogenous, smooth, and flat, with a low surface roughness of 1 nm. In addition, the structure and chemical properties of the PANI films are investigated by Fourier transform infrared spectroscopy, thus revealing an improvement in the degree of polymerization, even though the process was performed at low voltage.

6.
Polymers (Basel) ; 13(3)2021 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-33525506

RESUMEN

In-situ iodine (I2)-doped atmospheric pressure (AP) plasma polymerization is proposed, based on a newly designed AP plasma reactor with a single wire electrode that enables low-voltage-driven plasma polymerization. The proposed AP plasma reactor can proceed plasma polymerization at low voltage levels, thereby enabling an effective in-situ I2 doping process by maintaining a stable glow discharge state even if the applied voltage increases due to the use of a discharge gas containing a large amount of monomer vapors and doping materials. The results of field-emission scanning electron microscopy (FE-SEM) and Fourier transformation infrared spectroscopy (FT-IR) show that the polyaniline (PANI) films are successfully deposited on the silicon (Si) substrates, and that the crosslinking pattern of the synthesized nanoparticles is predominantly vertically aligned. In addition, the in-situ I2-doped PANI film fabricated by the proposed AP plasma reactor exhibits excellent electrical resistance without electrical aging behavior. The developed AP plasma reactor proposed in this study is more advantageous for the polymerization and in-situ I2 doping of conductive polymer films than the existing AP plasma reactor with a dielectric barrier.

7.
Ind Health ; 59(3): 161-170, 2021 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-33504718

RESUMEN

The purpose of this study was to evaluate upper-limb cooling following (treadmill) exercise performed in the heat (33℃, 70% relative humidity) at each of three speeds: light (6 km.h-1), intermediate (8 km.h-1) and moderate intensity (10 km.h-1). In all trials, exercise ceased when rectal temperature reached 39.0℃. Participants adopted a sitting position for a 20-min recovery, and liquid-cooling sleeves with cold water (6.3℃ were immediately positioned. The chosen work rates resulted in a two-fold difference in exercise duration across those trials, which terminated without significant between-trial differences within either auditory canal or rectal temperatures. Auditory canal temperature elevation rates became progressively faster as the work rate increased: 0.03℃.min-1 (light), 0.05℃.min-1 (intermediate) and 0.07℃.min-1 (moderate) (p<0.05). However, heat extraction during recovery did not differ among those treatments: -11.2 W (SE 0.5; light), -11.8 W (0.6; intermediate) and -12.3 W (0.5; moderate; p>0.05). That outcome was reflected in auditory canal cooling rates (0.03℃.min-1 [light], 0.04℃.min-1 [intermediate] and 0.05℃.min-1 [moderate]). Nevertheless, rectal temperatures continued to rise throughout recovery. It is concluded that heat extraction from moderately hyperthermic individuals, using upper-limb cooling sleeves, appears to be equally rapid, regardless of heating speed, providing the same level of hyperthermia was attained prior to initiating treatment.


Asunto(s)
Antebrazo , Calefacción , Temperatura Corporal , Regulación de la Temperatura Corporal , Frío , Fiebre , Calor , Humanos
8.
Nanomaterials (Basel) ; 12(1)2021 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-35009982

RESUMEN

In atmospheric pressure (AP) plasma polymerization, increasing the effective volume of the plasma medium by expanding the plasma-generating region within the plasma reactor is considered a simple method to create regular and uniform polymer films. Here, we propose a newly designed AP plasma reactor with a cruciform wire electrode that can expand the discharge volume. Based on the plasma vessel configuration, which consists of a wide tube and a substrate stand, two tungsten wires crossed at 90 degrees are used as a common powered electrode in consideration of two-dimensional spatial expansion. In the wire electrode, which is partially covered by a glass capillary, discharge occurs at the boundary where the capillary terminates, so that the discharge region is divided into fourths along the cruciform electrode and the discharge volume can successfully expand. It is confirmed that although a discharge imbalance in the four regions of the AP plasma reactor can adversely affect the uniformity of the polymerized, nanostructured polymer film, rotating the substrate using a turntable can significantly improve the film uniformity. With this AP plasma reactor, nanostructured polythiophene (PTh) films are synthesized and the morphology and chemical properties of the PTh nanostructure, as well as the PTh-film uniformity and electrical properties, are investigated in detail.

9.
Polymers (Basel) ; 12(10)2020 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-32998239

RESUMEN

This paper investigates the properties of thiophene and aniline copolymer (TAC) films deposited by using atmospheric pressure plasma jets copolymerization technique relative to various blending ratios of aniline and thiophene monomer for synthesizing the donor-acceptor conjugated copolymers. Field emission scanning electron microscopy (FE-SEM) and atomic force microscopy are utilized to measure the surface morphology, roughness and film thickness of TAC films. Structural and chemical properties of TAC films are investigated by Fourier transforms-infrared spectroscopy (FT-IR), time of flight secondary ion mass spectrometry, and X-ray photoelectron spectroscopy. FE-SEM images show that the film thickness and nanoparticles size of the TAC films increase with an addition thiophene monomer in the aniline monomer. FE-SEM, FT-IR results show that TAC films are successfully synthesized on glass substrates in all cases. The iodine doped TAC film on the Si substrate with interdigitated electrodes shows the lowest electrical resistance at blending condition of thiophene of 25%.

10.
Ind Health ; 58(2): 91-106, 2020 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-31257232

RESUMEN

This study investigated the separate and combined effects of skin cooling and cold fluid ingestion on the alleviation of heat strain when wearing protective firefighting clothing at an air temperature of 30°C with 50%RH. A vest with the dual functions of cooling and providing sports drink supply (1.2% body mass) was developed. Eight males participated in the following four conditions: control [CON], drinking only [DO], cooling only [CO], and both cooling and drinking [CD]. The results showed that rectal (Tre), mean skin temperature (Tsk) and heart rate (HR) during recovery were lower for CD than for CON (p<0.05), while no significant differences between the four conditions were found during exercise. CO significantly reduced mean Tsk and HR and improved thermal sensation, whereas DO was effective for relieving thirst and lowering HR in recovery. In summary, the combined effect of skin cooling and fluid ingestion was synergistically manifested in Tre, Tsk and thermal sensation in recovery.Practitioner Summary: The present results provide data on a novel vest that contributes to alleviating firefighters' heat strain. Because a cooling vest after melting may be a burden for firefighters, this study indicates a practical way to reduce the additional weight load of the vest by drinking the melted fluid of the cooling packs.


Asunto(s)
Ingestión de Líquidos/fisiología , Bomberos , Calor , Ropa de Protección , Adulto , Temperatura Corporal/fisiología , Ejercicio Físico/fisiología , Frecuencia Cardíaca/fisiología , Respuesta al Choque Térmico , Humanos , Masculino , Temperatura Cutánea
11.
Polymers (Basel) ; 11(3)2019 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-30960380

RESUMEN

Pinhole free layers are needed in order to prevent oxygen and water from damaging flexible electrical and bio-devices. Although polymerized methyl methacrylate (polymethyl methacrylate, PMMA) for the pinhole free layer has been studied extensively in the past, little work has been done on synthesizing films of this material using atmospheric pressure plasma-assisted electro-polymerization. Herein, we report the synthesis and properties of plasma-PMMA (pPMMA) synthesized using the atmospheric pressure plasma-assisted electro-polymerization technique at room temperature. According to the Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS), and time of flight-secondary ion mass spectrometry (ToF-SIMS) results, the characteristic peaks from the pPMMA polymer chain were shown to have been detected. The results indicate that the percentage of hydrophobic groups (C⁻C and C⁻H) is greater than that of hydrophilic groups (C⁻O and O⁻C=O). The field emission-scanning electron microscope (FE-SEM) and thickness measurement results show that the surface morphology is quite homogenous and amorphous in nature, and the newly proposed pPMMA film at a thickness of 1.5 µm has high transmittance (about 93%) characteristics. In addition, the results of water contact angle tests show that pPMMA thin films can improve the hydrophobicity.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...