1.
J Chromatogr A ; 1685: 463584, 2022 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-36323099

RESUMEN

Comprehensive two-dimensional liquid chromatography (LC×LC) can provide enhanced resolving power and higher peak capacities for the separation of complex samples. The transfer of fractions of too high eluotropic strength from the first dimension, however, can lead to peak broadening. This process is related to the column dimensions, the flow rates, mobile phase compositions, and stationary phase compatibility. Temperature-responsive LC (TRLC) uses a smart polymer coupled to silica (poly(N-isopropylacrylamide), pNIPAAm), that exhibits a change in polarity upon modest variations in column temperature. Retention is thus modulated by temperature and not by organic solvents, allowing for the use of purely aqueous mobile phases. As these aqueous mobile phases depict a very low eluotropic strength on a reversed-phase column, it facilitates band refocusing at the second-dimension column head in TRLC×RPLC. One of the remaining obstacles of TRLC is the long analysis time. In this research, the potential of this column combination in terms of analyte refocusing will be exploited. First, it is shown that upwards flow gradients can be implemented in the first dimension of TRLC×RPLC. As the flow in the second dimension is maintained at a constant level, a first-dimension flow gradient does not lead to impaired sensitivity and has no negative effects on the resulting peak size. Then, the novel combination of a downwards temperature gradient with an upwards flow gradient will be introduced to speed up the analyses further. Analysis time was, depending on the method used, reduced by 36-54%, as demonstrated by the analysis of mixtures of food additives, phenolic compounds, and small molecule pharmaceuticals mimicking impurity analysis at a 0.05% level.


Asunto(s)
Cromatografía de Fase Inversa , Fenoles , Cromatografía Liquida/métodos , Temperatura , Cromatografía de Fase Inversa/métodos , Fenoles/química , Solventes , Agua
2.
Anal Chem ; 94(48): 16728-16737, 2022 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-36440685

RESUMEN

In comprehensive two-dimensional liquid chromatography (LC × LC), solvents of high eluotropic strength are frequently used in the first dimension (1D), which lead to peak broadening in the second dimension (2D). In the majority of the current LC × LC column combinations, analytes are less than optimally refocused upon transfer to the second column, which negatively affects sensitivity. Furthermore, the typical combination of 1 or 2.1 mm columns in the 1D paired with a 3 mm (or broader) column in the 2D leads to at least a 9- or 4-fold dilution and a corresponding loss of sensitivity when using concentration-sensitive detectors. This occurs due to the enhanced radial dilution of the analytes in a broader column, while the sensitivity problem is further exacerbated in LC × LC due to the high flow operated 2D. In this paper, we introduce a solution to neutralize and inverse this dilution problem through a reconcentrating solution using temperature-responsive liquid chromatography (TRLC) in the 1D, which is a purely aqueous separation mode. Full solute refocusing at the 2D column head is thereby obtained when TRLC is combined with reversed-phase liquid chromatography (RPLC). This is shown for the combination of a 2.1 mm I.D. TRLC column with decreasing RPLC column diameters (3-2.1-1 mm) operated at the same linear velocities, hence a resulting decrease in dilution, respectively. Ultraviolet (UV) and electrospray ionization time-of-flight mass spectrometry (ESI-TOF-MS) detection were used to determine the experimental detection limits. Sensitivity improvements with UV detection were somewhat lower than expected, but represent ∼1.5- and 3-fold sensitivity enhancement when using a 1 mm I.D. column compared to 2.1 or 3 mm I.D. columns in the 2D, respectively. This is attributed to extra-column dispersion and the poorer performance of 1 mm I.D. columns. A major benefit of the use of 1 mm I.D. columns in the 2D is that it allows split-free coupling of 2D effluent with ESI-MS (at 450 µL/min), making the coupling robust and simple. When using ESI-MS even better, albeit more variable, sensitivity enhancements were obtained on the narrower columns. The benefits of the methodology are demonstrated for paraben test solutes and for phenolic compounds in a blueberry extract by TRLC × RPLC-UV-ESI-TOF-MS.


Asunto(s)
Cromatografía de Fase Inversa , Espectrometría de Masa por Ionización de Electrospray , Temperatura , Cromatografía Liquida/métodos , Cromatografía de Fase Inversa/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Solventes/química
3.
Anal Chim Acta ; 1231: 340441, 2022 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-36220293

RESUMEN

Refractive index detection (RID) is attractive because it allows approaching the benefits of universal detection with liquid chromatography, by which ideally standard independent calibration and hence compound independent quantification becomes possible. Nevertheless, the implementation of RID has remained limited as it offers poor detection sensitivity while only being compatible with isocratic mobile phases. The implementation of compositional solvent gradients has remained prohibitively challenging in commercial HPLC-RID systems due to the resulting drastic alterations in refractive index and extreme baseline drift. While the refractive index is also highly dependent on temperature, more leeway appears possible to mitigate the problem, particularly when the used temperature gradients can be limited. Temperature-responsive liquid chromatography (TRLC) allows obtaining isocratic reversed phase type of separations, whereby retention is modulated via temperature changes âˆ¼ 15 °C-20 °C above and below the polymer conversion temperature. Elution profiles, reminiscent of what can be obtained with solvent gradients in conventional RPLC, can then be obtained by enacting downwards temperature gradients on the columns. This work comprises a proof-of-principle to illustrate the possibilities of combining thermal gradient TRLC with RID. The observed baseline drift appeared thereby very minor (<5 nRIU min-1), and hence easily controllable. Short chain fatty acids are used as representative compounds to assess this new approach. Overlapping calibration lines are accordingly obtained for all fatty acids between butyric and decanoic acid.


Asunto(s)
Polímeros , Refractometría , Cromatografía Líquida de Alta Presión/métodos , Cromatografía Liquida/métodos , Ácidos Decanoicos , Ácidos Grasos , Refractometría/métodos , Solventes/química , Temperatura
4.
Talanta ; 236: 122889, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34635268

RESUMEN

Phenolic compounds are an interesting class of natural products because of their proposed contribution to health benefits of foods and beverages and as a bio-source of organic (aromatic) building blocks. Phenolic extracts from natural products are often highly complex and contain compounds covering a broad range in molecular properties. While many 1D-LC and mass spectrometric approaches have been proposed for the analysis of phenolics, this complexity inevitably leads to challenging identification and purification. New insights into the composition of phenolic extracts can be obtained through online comprehensive two-dimensional liquid chromatography (LC × LC) coupled to photodiode array and mass spectrometric detection. However, several practical hurdles must be overcome to achieve high peak capacities and to obtain robust methods with this technique. In many LC × LC configurations, refocusing of analytes at the head of the 2D column is hindered by the high eluotropic strength of the solvent transferred from the 1D to the 2D, leading to peak breakthrough or broadening. LC × LC combinations whereby a purely aqueous mobile phase is used in the 1D and RPLC is used in the 2D are unaffected by these phenomena, leading to more robust methods. In this contribution, the combination of temperature-responsive liquid chromatography (TRLC) with RPLC is used for the first time for the analysis of phenolic extracts of natural origin to illustrate the potential of this alternative combination for natural product analyses. The possibilities of the combination are investigated through analysis of wine extracts by TRLC × RPLC-DAD and TRLC × RPLC-ESI-MS.


Asunto(s)
Cromatografía de Fase Inversa , Vino , Cromatografía Liquida , Fenoles/análisis , Temperatura
5.
Analyst ; 146(22): 6990-6996, 2021 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-34668892

RESUMEN

Temperature-responsive liquid chromatography (TRLC) allows for extensive retention and selectivity tuning through temperature in HPLC. This is mainly achieved through the use of a stationary phases comprising of a temperature-responsive polymer which undergoes a reversible change from hydrophilic to hydrophobic behaviour upon increasing the temperature. The approach can allow for reversed phase type separations to be achieved with purely aqueous mobile phases, whereby the retention is controlled through temperature instead of mobile phase composition. Despite the promising nature of such form of retention control under isocratic mobile phase conditions, TRLC can suffer from excessive retention of highly apolar solutes even at lower column temperatures whereby the polymer is considered hydrophilic. This is related both to a residual apolarity of the polymer chain and due to the high log P's and low water solubility of higly apolar compounds. While it was known that elution in TRLC doesn't necessarily has to be performed under purely aqueous conditions and that the use of organic co-solvents to the water is possible, the impact thereof on the temperature responsive behaviour itself had not yet been investigated in a systematic way. Therefore in this work the advantages and drawbacks of the use of the organic co-solvents methanol and acetonitrile in TRLC is assessed on two types of temperature reponsive phases: poly-N-N-propylacrylamide (PNNPAAm) and poly-N-isopropylacrylamide (PNIPAAm). The influence of organic co-solvents is investigated with two representative test mixtures (comprising 4 parabens and 5 apolar steroids).


Asunto(s)
Solventes , Cromatografía Líquida de Alta Presión , Cromatografía Liquida , Interacciones Hidrofóbicas e Hidrofílicas , Temperatura
6.
J Chromatogr A ; 1654: 462425, 2021 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-34425285

RESUMEN

Temperature Responsive Liquid Chromatography (TRLC) offers an alternative and environmentally friendly way to perform reversed-phase like separations. Its use of temperature responsive polymers to control retention based on column temperature, instead of the fraction of organic modifier in the mobile phase mobile, eliminates the need for solvent composition gradients and allows, for example, for purely aqueous separations. In principle this temperature induced retention should allow for gradient elutions to be performed using downward temperature gradients to control retention and refocus the analyte peaks. Yet, the unavailability of dedicated commercial temperature controlling systems allowing suitable temperature control in TRLC limits implementations thereof often to isothermal or step gradient applications. In this work we study the potential of 1) a simple yet programmable water bath and of 2) a modified HPLC system allowing column temperature programming through controlled mixing of a warm and cold mobile phase streams. The performance of both systems was evaluated under both isocratic and gradient applications, resulting in a more thorough understanding of the influence of temperature gradients in TRLC. This knowledge is then applied to a sample of phenolic solutes, illustrating that, although both systems have some flaws, both are able to impose temperature gradients in TRLC resulting in significantly reduced retention and enhanced refocusing of the analyte peak.


Asunto(s)
Técnicas de Química Analítica , Cromatografía Líquida de Alta Presión , Temperatura , Técnicas de Química Analítica/métodos , Soluciones , Solventes
7.
Anal Chim Acta ; 1142: 157-168, 2021 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-33280693

RESUMEN

A comprehensive two-dimensional liquid chromatography-based biomimetic platform (LCxLC) has been developed and validated for drug diffusion studies. Human serum albumin (HSA) and immobilized artificial membrane (IAM) were thereby used in the first (1D) and second (2D) separation dimension, respectively. While the former was meant to emulate the blood, the latter was instead intended to mimic the intestinal mucosa epithelium. Therefore, the experimental conditions, i.e. pH, temperature and buffer composition, were modulated to reflect faithfully in vivo conditions. 30 compounds, whose effective intestinal permeability (Peff) assayed in situ on humans by a validated technique was known from the literature, were used as model drugs. A good and orthogonal separation was achieved for the whole dataset, although for a better distribution of the most polar compounds in the elution window a segmented gradient elution program had to be employed. Interestingly, the passively uptaken compounds having the most favourable Peff populated a specific area of the 2D plots, implying that the affinity for HSA and IAM has to lie in specific ranges in order for a compound to be satisfactorily absorbed from the intestinal lumen. Although these results should be regarded as preliminary, this work paves an entirely new and unprecedented way to profile pharmaceutically relevant compounds for their in vivo absorption and distribution potential.


Asunto(s)
Biomimética , Membranas Artificiales , Cromatografía Líquida de Alta Presión , Desarrollo de Medicamentos , Humanos , Permeabilidad
8.
J Chromatogr A ; 1630: 461561, 2020 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-32992220

RESUMEN

In this study, the possibilities of temperature responsive × reversed phase liquid chromatography (TRLC × RPLC) are assessed in terms of pharmaceutical impurity analysis. Due to the increased peak capacity per unit time they offer, two-dimensional LC approaches are gaining relevance for the analysis of complex drug formulations. Because the latter depicts a larger predisposition for the occurrence of an increased number of impurities, current 1D-HPLC approaches often prove insufficient. Since many LC × LC methods are limited by modulation, solvent compatibility, orthogonality, and sensitivity issues, the combination of TRLC × RPLC is explored in this work for pharmaceutical impurity analysis. As this combination of a purely aqueous separation with RPLC allows for systematic and optimization-free refocusing in the second dimension, it opens possibilities for generic LC × LC requiring minimal to no method development, in this way overcoming a major perceived contemporary hurdle of LC × LC. The approach is demonstrated with a representative mixture of 17 solutes comprising 11 corticosteroids and 6 progestogens. Orthogonality and peak capacities were assessed on three RP core-shell column selectivities (Poroshell EC-C18, phenyl-hexyl and PFP). Although the TRLC × EC-C18 combination offered somewhat better orthogonality, the combination with the PFP column proved the best for the separation at hand. Depending on the composition of the mixture, the use of full, shifted, or segmented gradients allowed facile optimization of the separation. The developed platform allowed detection of the impurities at the 0.05% level compared to a selected main compound, while also opening up possibilities for analysis of formulations comprising two active ingredients.

9.
Anal Chem ; 92(14): 9815-9822, 2020 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-32598128

RESUMEN

Temperature responsive liquid chromatography (TRLC) allows for separation of organic solutes in purely aqueous mobile phases whereby retention is controlled through temperature. The vast majority of the work has thus far been performed on poly[N-isopropylacrylamide] (PNIPAAm)-based columns, while the performance of other temperature responsive polymers has rarely been compared under identical conditions. Therefore, in this work, two novel TRLC phases based on poly[N-n-propylacrylamide] (PNNPAAm) and poly[N,N-diethylacrylamide] (PDEAAm) are reported and compared to the state of the art PNIPAAm based column. Optimal comparison is thereby obtained by the use of controlled radical polymerizations, identical molecular weights, and by maximizing carbon loads on the silica supporting material. Analysis of identical test mixtures of homologue series and pharmaceutical samples revealed that PNNPAAm performs in a similar way as PNIPAAm while offering enhanced retention and a shift of the useable temperature range toward lower temperatures. PDEAAm offers a range of novel possibilities as it depicts a different selectivity, allowing for enhanced resolution in TRLC in, for example, coupled column systems. Reduced plate heights of 3 could be obtained on the homemade columns, offering the promise for reasonable column efficiencies in TRLC despite the use of bulky polymers as stationary phases in HPLC.

10.
Anal Chem ; 90(8): 4961-4967, 2018 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-29551061

RESUMEN

Comprehensive two-dimensional liquid chromatography (LC × LC) allows for substantial gains in theoretical peak capacity in the field of liquid chromatography. However, in practice, theoretical performance is rarely achieved due to a combination of undersampling, orthogonality, and refocusing issues prevalent in many LC × LC applications. This is intricately linked to the column dimensions, flow rates, and mobile-phase compositions used, where, in many cases, incompatible or strong solvents are introduced in the second-dimension (2D) column, leading to peak broadening and the need for more complex interfacing approaches. In this contribution, the combination of temperature-responsive (TR) and reversed-phase (RP) LC is demonstrated, which, due to the purely aqueous mobile phase used in TRLC, allows for complete and more generic refocusing of organic solutes prior to the second-dimension RP separation using a conventional 10-port valve interface. Thus far, this was only possible when combining other purely aqueous modes such as ion exchange or gel filtration chromatography with RPLC, techniques which are limited to the analysis of charged or high MW solutes, respectively. This novel TRLC × RPLC combination relaxes undersampling constraints and complete refocusing and therefore offers novel possibilities in the field of LC × LC including temperature modulation. The concept is illustrated through the TRLC × RPLC analysis of mixtures of neutral organic solutes.