Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Perfusion ; : 2676591241246080, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38647100

RESUMEN

BACKGROUND: Ultrafiltration (UF) is a common practice during cardiopulmonary bypass (CPB) where it is used as a blood management strategy to reduce red blood cell (RBC) transfusion, minimize adverse effects of hemodilution, and reduce proinflammatory mediators. However, its clinical utilization has been shown to vary throughout the continents. PURPOSE: The purpose of this investigation was to assess the distribution of UF use across the United States. DATA COLLECTION: Data on UF use during cardiac surgery was obtained from a national (United States) perfusion database for adult cardiac procedures performed from January 2016 through December 2018. STUDY SAMPLE: Four geographical regions were established: Northeast (NE), South (SO), Midwest (MW) and West (WE). The primary endpoint was the use of UF with secondary endpoints UF volume, CPB and anesthesia asanguineous volumes, intraoperative allogeneic RBC transfusion, nadir hematocrit and urine output (UO). 92,859 adult cardiac cases from 191 hospitals were reviewed. RESULTS: The NE and the WE had similar usages of UF (59.9% and 59.7% respectively), which were higher than the MW and the SO (38.6% and 34.9%, p < .001). When UF was utilized, the median [IQR] volume removed was highest in the NE (1900 [1200-2800]mL), and similar in all other regions (WE 1500 [850-2400 mL, MW 1500 [900-2300]mL and SO 1500 [950-2200]mL, p < .001. Median total UO was lowest in the NE 400 [210,650]mL vs all other regions (p < .001), and remained so when indexed by patient weight and operative time (NE-0.8 [0.5, 1.3]mL/kg/hour, MW-1.1 [0.7, 1.8] mL/kg/hour, SO-1.3 [0.8, 2.0]mL/kg/hour, WE-1.1 [0.7, 1.3]mL/kg/hour, p < .001. Intraoperative RBC transfusion rate was highest in the SO (21.3%) and WE (20.5%), while similar rates seen in the NE (16.2%) and MW (17.6%), p < .001. CONCLUSIONS: Across the United States there is geographic variation on the use of UF. Further research is warranted to investigate why these practice variations exist and to better understand and determine their reasons for use.

2.
Perfusion ; : 2676591231198366, 2023 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-37632252

RESUMEN

Targeted oxygen delivery during cardiopulmonary bypass (CPB) has received significant attention due to its influence on patient outcomes, especially in mitigating acute kidney injury. While it has gained popularity in select institutions, there remains a gap in establishing it globally across multiple centers. The purpose of this investigation was to describe the development of a quality improvement process of targeted oxygen delivery during CPB across hospitals throughout the United States. A systematic approach to utilize oxygen delivery index (DO2i) as a key performance indicator within hospitals serviced by a national provider of perfusion services. The process included a review of the current literature on DO2i, which yielded a target nadir value (272 mL/min/m2) and an area under the curve (DO2i272AUC) cut off of 632. All data is displayed on a dashboard with results categorized across multiple levels from system-wide to individual clinician performance. From January 2020 through December 2022, DO2i data from 91 hospitals and 11,165 coronary artery bypass graft procedures were collected. During this period the monthly proportion of DO2i measurements above the target nadir DO2i272 ranged from 60.5% to 78.4% with a mean+/-SD of 70.8 +/- 4.2%. Binary logistic regression for the first 7 months following monthly DO2i performance reporting has shown a statistically significant positive linear trend in the probability of achieving the target DO2i272 (p < .001), with a crude increase of approximately 7.8% for DO2i272AUC, and a 73.8% success rate (p < .001). A survey was sent to all individuals measuring oxygen delivery during CPB to assess why a target DO2i272 could not be reached. The two most common responses were an 'inability to improve CPB flow rates' and 'restrictive allogeneic red blood cell transfusion policies'. This study demonstrates that targeting a minimum level of oxygen delivery can serve as a key performance indicator during CPB using a structured quality improvement process.

3.
PLoS One ; 11(4): e0154346, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27111766

RESUMEN

The purpose of the study was to compare the force outputs achieved during a squat exercise using a rotational inertia device in stable versus unstable conditions with different loads and in concentric and eccentric phases. Thirteen male athletes (mean ± SD: age 23.7 ± 3.0 years, height 1.80 ± 0.08 m, body mass 77.4 ± 7.9 kg) were assessed while squatting, performing one set of three repetitions with four different loads under stable and unstable conditions at maximum concentric effort. Overall, there were no significant differences between the stable and unstable conditions at each of the loads for any of the dependent variables. Mean force showed significant differences between some of the loads in stable and unstable conditions (P < 0.010) and peak force output differed between all loads for each condition (P < 0.045). Mean force outputs were greater in the concentric than in the eccentric phase under both conditions and with all loads (P < 0.001). There were no significant differences in peak force between concentric and eccentric phases at any load in either stable or unstable conditions. In conclusion, squatting with a rotational inertia device allowed the generation of similar force outputs under stable and unstable conditions at each of the four loads. The study also provides empirical evidence of the different force outputs achieved by adjusting load conditions on the rotational inertia device when performing squats, especially in the case of peak force. Concentric force outputs were significantly higher than eccentric outputs, except for peak force under both conditions. These findings support the use of the rotational inertia device to train the squatting exercise under unstable conditions for strength and conditioning trainers. The device could also be included in injury prevention programs for muscle lesions and ankle and knee joint injuries.


Asunto(s)
Fuerza Muscular/fisiología , Levantamiento de Peso , Adulto , Atletas , Fenómenos Biomecánicos , Humanos , Articulación de la Rodilla/fisiología , Masculino , Contracción Muscular/fisiología , Músculo Esquelético/fisiología , Reproducibilidad de los Resultados , Entrenamiento de Fuerza , Estrés Mecánico , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...