Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Pathogens ; 12(3)2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36986317

RESUMEN

Monkeypox virus (MPXV), a member of the Orthopoxvirus (OPXV) genus, is a zoonotic virus, endemic to central and western Africa that can cause smallpox-like symptoms in humans with fatal outcomes in up to 15% of patients. The incidence of MPXV infections in the Democratic Republic of the Congo, where the majority of cases have occurred historically, has been estimated to have increased as much as 20-fold since the end of smallpox vaccination in 1980. Considering the risk global travel carries for future disease outbreaks, accurate epidemiological surveillance of MPXV is warranted as demonstrated by the recent Mpox outbreak, where the majority of cases were occurring in non-endemic areas. Serological differentiation between childhood vaccination and recent infection with MPXV or other OPXVs is difficult due to the high level of conservation within OPXV proteins. Here, a peptide-based serological assay was developed to specifically detect exposure to MPXV. A comparative analysis of immunogenic proteins across human OPXVs identified a large subset of proteins that could potentially be specifically recognized in response to a MPXV infection. Peptides were chosen based upon MPXV sequence specificity and predicted immunogenicity. Peptides individually and combined were screened in an ELISA against serum from well-characterized Mpox outbreaks, vaccinee sera, and smallpox sera collected prior to eradication. One peptide combination was successful with ~86% sensitivity and ~90% specificity. The performance of the assay was assessed against the OPXV IgG ELISA in the context of a serosurvey by retrospectively screening a set of serum specimens from the region in Ghana believed to have harbored the MPXV-infected rodents involved in the 2003 United States outbreak.

2.
J Virol Methods ; 300: 114354, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34774617

RESUMEN

BACKGROUND: The cross-contamination of cell lines in culture is a persistent problem. Genetically modified L20B (Mouse) and RD (Human Rhabdomyosarcoma) cell lines are commonly used in poliovirus research, surveillance, and diagnostics. Cross-contamination between these cell lines leads to unreproducible results and unreliable surveillance data, negatively affecting public health. The gold standard method for cell authentication is Short Tandem Repeats analysis, which is time-consuming and expensive. The disadvantage of STR is limited detection of interspecies contamination. METHODS: This assay targets the mitochondrial cytochrome c oxidase subunit I (MTCO1) gene, a highly conserved and emergent DNA barcode region for detection of cross-contamination in RD and L20B cell lines. The MagNA Pure Compact instrument and ABI 7500 Fast Dx Real-time PCR systems were used for DNA extraction and to perform real-time PCR respectively. RESULTS: The newly developed assay is very sensitive with a limit of detection of 100 RD cells/1 million L20B/mL. The amplification efficiency and R2-value were 102.26% and 0.9969 respectively. We evaluated specificity of the assay with five human and four mouse cell lines, as well as monkey and rat cell lines. The assay showed no cross-reactivity with genomic DNA from human, mouse, rat, or monkey cell lines. The analytical sensitivity was also evaluated by spiking varying amounts of RD cells (0.001% - 10%) into L20B cells. There was no difference in CT values when running single-plex or duplex PCR reactions with similar experimental conditions. CONCLUSIONS: We have developed and validated a TaqMan real-time PCR assay, a sensitive method for the detection of cross-contamination of RD and L20B cell lines.


Asunto(s)
Poliovirus , Animales , Línea Celular , Haplorrinos/genética , Humanos , Ratones , Técnicas de Amplificación de Ácido Nucleico , Poliovirus/genética , Ratas , Reacción en Cadena en Tiempo Real de la Polimerasa , Sensibilidad y Especificidad
3.
PLoS One ; 16(12): e0260487, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34910739

RESUMEN

At the start of the COVID-19 pandemic, the Centers for Disease Control and Prevention (CDC) designed, manufactured, and distributed the CDC 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel for SARS-CoV-2 detection. The diagnostic panel targeted three viral nucleocapsid gene loci (N1, N2, and N3 primers and probes) to maximize sensitivity and to provide redundancy for virus detection if mutations occurred. After the first distribution of the diagnostic panel, state public health laboratories reported fluorescent signal in the absence of viral template (false-positive reactivity) for the N3 component and to a lesser extent for N1. This report describes the findings of an internal investigation conducted by the CDC to identify the cause(s) of the N1 and N3 false-positive reactivity. For N1, results demonstrate that contamination with a synthetic template, that occurred while the "bulk" manufactured materials were located in a research lab for quality assessment, was the cause of false reactivity in the first lot. Base pairing between the 3' end of the N3 probe and the 3' end of the N3 reverse primer led to amplification of duplex and larger molecules resulting in false reactivity in the N3 assay component. We conclude that flaws in both assay design and handling of the "bulk" material, caused the problems with the first lot of the 2019-nCoV Real-Time RT-PCR Diagnostic Panel. In addition, within this study, we found that the age of the examined diagnostic panel reagents increases the frequency of false positive results for N3. We discuss these findings in the context of improvements to quality control, quality assurance, and assay validation practices that have since been improved at the CDC.


Asunto(s)
COVID-19 , Cartilla de ADN , Reacciones Falso Positivas , Humanos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2
4.
Sci Rep ; 11(1): 9682, 2021 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-33958613

RESUMEN

The need for high-affinity, SARS-CoV-2-specific monoclonal antibodies (mAbs) is critical in the face of the global COVID-19 pandemic, as such reagents can have important diagnostic, research, and therapeutic applications. Of greatest interest is the ~ 300 amino acid receptor binding domain (RBD) within the S1 subunit of the spike protein because of its key interaction with the human angiotensin converting enzyme 2 (hACE2) receptor present on many cell types, especially lung epithelial cells. We report here the development and functional characterization of 29 nM-affinity mouse SARS-CoV-2 mAbs created by an accelerated immunization and hybridoma screening process. Differing functions, including binding of diverse protein epitopes, viral neutralization, impact on RBD-hACE2 binding, and immunohistochemical staining of infected lung tissue, were correlated with variable gene usage and sequence.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/inmunología , COVID-19/inmunología , SARS-CoV-2/inmunología , Animales , COVID-19/diagnóstico , Prueba Serológica para COVID-19 , Epítopos/inmunología , Femenino , Humanos , Inmunización , Ratones , Ratones Endogámicos BALB C , Modelos Moleculares , SARS-CoV-2/aislamiento & purificación , Glicoproteína de la Espiga del Coronavirus/inmunología
5.
J Virol Methods ; 287: 114004, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33098957

RESUMEN

Zika virus (ZIKV) infection remains a public health concern necessitating demand for long-term virus production for diagnostic assays and R&D activities. Inactivated virus constitutes an important component of the Trioplex rRT-PCR assay and serological IgM assay (MAC-ELISA). The aim of our study is to establish standard methods of ZIKV inactivation while maintaining antigenicity and RNA integrity. We tested viral supernatants by four different inactivation methods: 1. Heat inactivation at 56 °C and 60 °C; 2. Gamma-Irradiation; 3. Chemical inactivation by Beta-propiolactone (BPL) and 4. Fast-acting commercial disinfecting agents. Effectivity was measured by cytopathic effect (CPE) and plaque assay. RNA stability and antigenicity were measured by RT-PCR and MAC-ELISA, respectively. Results: Heat inactivation: Low titer samples, incubated at 56 °C for 2 h, showed neither CPE or plaques compared to high titer supernatants that required 2.5 h. Inactivation occurred at 60 °C for 60 min with all virus titers. Gamma irradiation: Samples irradiated at ≥3 Mrad for low virus concentrations and ≥5Mrad for high virus titer completely inactivated virus. Chemical Inactivation: Neither CPE nor plaques were observed with ≥0.045 % BPL inactivation of ZIKV. Disinfectant: Treatment of viral supernatants with Micro-Chem Plus™, inactivated virus in 2 min, whereas, Ethanol (70 %) and STERIS Coverage® Spray TB inactivated the virus in 5 min.


Asunto(s)
Infección por el Virus Zika , Virus Zika , Desinfección , Humanos , Indicadores y Reactivos , Inactivación de Virus , Infección por el Virus Zika/diagnóstico
6.
J Appl Lab Med ; 5(2): 273-280, 2020 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32445395

RESUMEN

BACKGROUND: Irradiative sterilization of clinical specimens prior to chemical laboratory testing provides a way to not only sterilize pathogens and ensure laboratorian safety but also preserve sample volume and maintain compatibility with quantitative chemical diagnostic protocols. Since the compatibility of clinical biomarkers with gamma irradiation is not well characterized, a subset of diagnostic biomarkers ranging in molecular size, concentration, and clinical matrix was analyzed to determine recovery following gamma irradiation. METHODS: Sample irradiation of previously characterized quality control materials (QCs) at 5 Mrad was carried out at the Gamma Cell Irradiation Facility at the Centers for Disease Control and Prevention (CDC) in Atlanta, GA. Following irradiation, the QCs were analyzed alongside non-irradiated QCs to determine analyte recovery between dosed and control samples. RESULTS: Biomarkers for exposure to abrin, ricin, and organophosphorus nerve agents (OPNAs) were analyzed for their stability following gamma irradiation. The diagnostic biomarkers included adducts to butyrylcholinesterase, abrine, and ricinine, respectively, and were recovered at over 90% of their initial concentration. CONCLUSIONS: The results from this pilot study support the implementation of an irradiative sterilization protocol for possible mixed-exposure samples containing both chemical and biological threat agents (mixed CBTs). Furthermore, irradiative sterilization significantly reduces a laboratorian's risk of infection from exposure to an infectious agent without compromising chemical diagnostic testing integrity, particularly for diagnostic assays in which the chemical analyte has been shown to be fully conserved following a 5 Mrad irradiative dose.


Asunto(s)
Biomarcadores , Rayos gamma , Esterilización , Alcaloides/análisis , Alcaloides/química , Biomarcadores Farmacológicos/análisis , Biomarcadores Farmacológicos/química , Seguridad Química , Cromatografía Líquida de Alta Presión , Seguridad de Productos para el Consumidor , Seguridad de Equipos , Alcaloides Indólicos/análisis , Alcaloides Indólicos/química , Proyectos Piloto , Piridonas/análisis , Piridonas/química , Control de Calidad , Dosis de Radiación , Esterilización/métodos
7.
Anal Bioanal Chem ; 411(12): 2493-2509, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30911800

RESUMEN

Inhalation of Bacillus anthracis spores can cause a rapidly progressing fatal infection. B. anthracis secretes three protein toxins: lethal factor (LF), edema factor (EF), and protective antigen (PA). EF and LF may circulate as free or PA-bound forms. Both free EF (EF) and PA-bound-EF (ETx) have adenylyl cyclase activity converting ATP to cAMP. We developed an adenylyl cyclase activity-based method for detecting and quantifying total EF (EF+ETx) in plasma. The three-step method includes magnetic immunocapture with monoclonal antibodies, reaction with ATP generating cAMP, and quantification of cAMP by isotope-dilution HPLC-MS/MS. Total EF was quantified from 5PL regression of cAMP vs ETx concentration. The detection limit was 20 fg/mL (225 zeptomoles/mL for the 89 kDa protein). Relative standard deviations for controls with 0.3, 6.0, and 90 pg/mL were 11.7-16.6% with 91.2-99.5% accuracy. The method demonstrated 100% specificity in 238 human serum/plasma samples collected from unexposed healthy individuals, and 100% sensitivity in samples from 3 human and 5 rhesus macaques with inhalation anthrax. Analysis of EF in the rhesus macaques showed that it was detected earlier post-exposure than B. anthracis by culture and PCR. Similar to LF, the kinetics of EF over the course of infection were triphasic, with an initial rise (phase-1), decline (phase-2), and final rapid rise (phase-3). EF levels were ~ 2-4 orders of magnitude lower than LF during phase-1 and phase-2 and only ~ 6-fold lower at death/euthanasia. Analysis of EF improves early diagnosis and adds to our understanding of anthrax toxemia throughout infection. The LF/EF ratio may also indicate the stage of infection and need for advanced treatments.


Asunto(s)
Carbunco/patología , Antígenos Bacterianos/sangre , Bacillus anthracis/patogenicidad , Toxinas Bacterianas/sangre , Cromatografía Líquida de Alta Presión/métodos , Infecciones del Sistema Respiratorio/patología , Espectrometría de Masas en Tándem/métodos , Toxemia/patología , Adenosina Trifosfato/metabolismo , Animales , Carbunco/sangre , Estudios de Casos y Controles , AMP Cíclico/biosíntesis , Progresión de la Enfermedad , Ensayo de Inmunoadsorción Enzimática , Humanos , Límite de Detección , Macaca mulatta , Reacción en Cadena de la Polimerasa , Infecciones del Sistema Respiratorio/sangre , Toxemia/sangre , Toxemia/microbiología
8.
Mycoses ; 62(6): 513-518, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30801778

RESUMEN

Candida auris is an emerging multidrug-resistant yeast associated with invasive infection in healthcare settings. Recently, C auris cases in the United States have been detected in 11 states with the majority of cases in New York, New Jersey and Illinois. Rapid and accurate identification of C auris is critical for patient care and the implementation of public health measures to control the spread of infection. Our aim was to develop and validate a rapid DNA extraction method using the Roche MagNA Pure 96 instrument and a TaqMan real-time PCR assay for reliable, high-throughput identification of C auris. We evaluated 247 patient dermal swab samples previously analysed by culture/MALDI-TOF. The diagnostic sensitivity and specificity were 93.6% and 97.2%, respectively. The assay was highly reproducible with a detection limit of 1 C auris CFU/10 µL. A receiver operating characteristic curve analysis of the real-time PCR data showed an area of 0.982 under the curve, with a CT cut-off value of ≤37.0. The turnaround time from DNA extraction to real-time PCR results was approximately 200 samples/day. In conclusion, we successfully validated a rapid and high-throughput method for accurate and reproducible identification of C auris with a significantly reduced turnaround time compared to culture/MALDI-TOF based methods.


Asunto(s)
Candida/aislamiento & purificación , Candidiasis Invasiva/diagnóstico , Candidiasis Invasiva/microbiología , ADN de Hongos/aislamiento & purificación , Técnicas de Diagnóstico Molecular/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Manejo de Especímenes/métodos , Candida/genética , Enfermedades Transmisibles Emergentes/diagnóstico , Enfermedades Transmisibles Emergentes/microbiología , ADN de Hongos/genética , Farmacorresistencia Fúngica Múltiple , Humanos , Curva ROC , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo , Estados Unidos
9.
Biosens Bioelectron ; 100: 85-88, 2018 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-28865242

RESUMEN

We have developed a cost-effective and portable graphene-enabled biosensor to detect Zika virus with a highly specific immobilized monoclonal antibody. Field Effect Biosensing (FEB) with monoclonal antibodies covalently linked to graphene enables real-time, quantitative detection of native Zika viral (ZIKV) antigens. The percent change in capacitance in response to doses of antigen (ZIKV NS1) coincides with levels of clinical significance with detection of antigen in buffer at concentrations as low as 450pM. Potential diagnostic applications were demonstrated by measuring Zika antigen in a simulated human serum. Selectivity was validated using Japanese Encephalitis NS1, a homologous and potentially cross-reactive viral antigen. Further, the graphene platform can simultaneously provide the advanced quantitative data of nonclinical biophysical kinetics tools, making it adaptable to both clinical research and possible diagnostic applications. The speed, sensitivity, and selectivity of this first-of-its-kind graphene-enabled Zika biosensor make it an ideal candidate for development as a medical diagnostic test.


Asunto(s)
Anticuerpos Inmovilizados/química , Antígenos Virales/análisis , Técnicas Biosensibles/métodos , Grafito/química , Infección por el Virus Zika/diagnóstico , Virus Zika/aislamiento & purificación , Antígenos Virales/sangre , Técnicas Biosensibles/instrumentación , Diseño de Equipo , Humanos , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Sensibilidad y Especificidad , Infección por el Virus Zika/sangre , Infección por el Virus Zika/virología
10.
J Immunol Methods ; 408: 78-88, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24857756

RESUMEN

Inhalation anthrax is a rare but acute infectious disease following adsorption of Bacillus anthracis spores through the lungs. The disease has a high fatality rate if untreated, but early and correct diagnosis has a significant impact on case patient recovery. The early symptoms of inhalation anthrax are, however, non-specific and current anthrax diagnostics are primarily dependent upon culture and confirmatory real-time PCR. Consequently, there may be a significant delay in diagnosis and targeted treatment. Rapid, culture-independent diagnostic tests are therefore needed, particularly in the context of a large scale emergency response. The aim of this study was to evaluate the ability of monoclonal antibodies to detect anthrax toxin proteins that are secreted early in the course of B. anthracis infection using a time-resolved fluorescence (TRF) immunoassay. We selected monoclonal antibodies that could detect protective antigen (PA), as PA83 and also PA63 and LF in the lethal toxin complex. The assay reliable detection limit (RDL) was 6.63×10(-6)µM (0.551ng/ml) for PA83 and 2.51×10(-5)µM (1.58ng/ml) for PA63. Despite variable precision and accuracy of the assay, PA was detected in 9 out of 10 sera samples from anthrax confirmed case patients with cutaneous (n=7), inhalation (n=2), and gastrointestinal (n=1) disease. Anthrax Immune Globulin (AIG), which has been used in treatment of clinical anthrax, interfered with detection of PA. This study demonstrates a culture-independent method of diagnosing anthrax through the use of monoclonal antibodies to detect PA and LF in the lethal toxin complex.


Asunto(s)
Carbunco/diagnóstico , Anticuerpos Monoclonales , Antígenos Bacterianos/sangre , Bacillus anthracis/inmunología , Toxinas Bacterianas/sangre , Europio , Inmunoensayo/métodos , Carbunco/sangre , Carbunco/inmunología , Vacunas contra el Carbunco/inmunología , Biomarcadores/sangre , Estudios de Casos y Controles , Diagnóstico Precoz , Fluoroinmunoensayo , Humanos , Límite de Detección , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados
11.
Anal Chem ; 79(22): 8463-70, 2007 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-17929949

RESUMEN

The lethal toxin produced during Bacillus anthracis infection is a complex of protective antigen, which localizes the toxin to the cell receptor, and lethal factor (LF), a zinc-dependent endoproteinase whose known targets include five members of the mitogen-activated protein kinase kinase (MAPKK) family of response regulators. We have developed a method for detecting functional LF in serum. Anti-LF murine monoclonal antibodies immobilized on magnetic protein G beads were used to capture and concentrate the LF from serum. The captured LF was exposed to an optimized MAPKK-based peptide substrate, which it hydrolyzed into two smaller peptides. The LF cleavage products were then analyzed by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MS) and quantified by isotope dilution-MS. The entire analytical method can be performed in less than 4 h with detection of LF levels as low as 0.05 ng/mL. The method was used to quantify LF levels in serum from rhesus macaques infected with B. anthracis. Serum samples obtained at day 2 postinfection contained 30-250 ng/mL LF and illustrated the clear potential to detect LF earlier in the infection cycle. This method represents a highly specific and rapid diagnostic tool for early anthrax and has a potential additional role as a research tool for understanding toxemia and effects of medical countermeasures for anthrax.


Asunto(s)
Antígenos Bacterianos/sangre , Toxinas Bacterianas/sangre , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Secuencia de Aminoácidos , Animales , Anticuerpos/inmunología , Antígenos Bacterianos/química , Antígenos Bacterianos/inmunología , Toxinas Bacterianas/química , Toxinas Bacterianas/inmunología , Macaca mulatta/sangre , Quinasas de Proteína Quinasa Activadas por Mitógenos/química , Quinasas de Proteína Quinasa Activadas por Mitógenos/clasificación , Datos de Secuencia Molecular , Péptidos/química , Péptidos/metabolismo , Alineación de Secuencia , Especificidad por Sustrato
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...