Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Vet Ophthalmol ; 27(1): 95-100, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37952123

RESUMEN

OBJECTIVE: To compare intraocular pressure (IOP) measurements in dogs taken with the Reichert® Tono-Vera® Vet rebound tonometer with and without the automatic positioning system. ANIMALS STUDIED: Measurements were taken on 49 eyes from 26 Beagle-derived dogs with variable genetics-four non-glaucomatous and 22 ADAMTS10-mutant dogs affected with different stages of open-angle glaucoma. Seventeen of the 26 dogs were measured 2-4 times on different days with variable intervals since IOP-lowering medications were administered. PROCEDURES: In each dog, tonometry was performed with the Tono-Vera® Vet using three different methods in a randomized order: (Method 1) Average of three readings with an automatic positioning system; (Method 2) one reading with an automatic positioning system; and (Method 3) average of three readings obtained without the automatic positioning system. Statistical analyses included one-way ANOVA, Tukey pairwise comparisons, and Bland-Altman plots (MiniTab®). RESULTS: With each of the three tonometry methods, 116 measurements were taken, resulting in 348 total IOP measurements with a range of 12.8-49.9 mmHg. The means and standard deviations for each method were 25.4 ± 6.9 mmHg (Method 1), 26.0 ± 7.2 mmHg (Method 2), and 26.9 ± 7.7 mmHg (Method 3), with no significant differences (p = .27). Mean IOP variances were also not significantly different between tonometry methods (p = .24 to .78). CONCLUSIONS: Because mean IOPs and their standard deviations were not statistically different between the three tonometry methods, we conclude that Tono-Vera® Vet measurements conducted without the aid of the positioning system still provide reliable results.


Asunto(s)
Enfermedades de los Perros , Glaucoma de Ángulo Abierto , Perros , Animales , Presión Intraocular , Glaucoma de Ángulo Abierto/veterinaria , Tonometría Ocular/veterinaria , Tonometría Ocular/métodos , Ojo , Manometría/veterinaria , Reproducibilidad de los Resultados , Enfermedades de los Perros/diagnóstico
2.
Vet Ophthalmol ; 26(1): 31-38, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36440595

RESUMEN

OBJECTIVE: The objectives of the study were to compare intraocular pressure (IOP) readings across a wide range and obtained via three rebound tonometers in ADAMTS10-mutant Beagle-derived dogs with different stages of open-angle glaucoma (OAG) and normal control dogs and to investigate the effect of central corneal thickness (CCT). ANIMALS STUDIED: Measurements were performed on 99 eyes from 50 Beagle-derived dogs with variable genetics-16 non-glaucomatous and 34 with ADAMTS10-OAG. Seventeen OAG eyes were measured twice-with and without the use of IOP-lowering medications. PROCEDURES: IOP was measured in each eye using three tonometers with their "dog" setting-ICare® Tonovet (TV), ICare® Tonovet Plus® (TVP), and the novel Reichert® Tono-Vera® Vet (TVA)-in randomized order. CCT was measured with the Accutome® PachPen. Statistical analyses included one-way ANOVA, Tukey pairwise comparisons, and regression analyses of tonometer readings and pairwise IOP-CCT Pearson correlations (MiniTab®). RESULTS: A total of 116 IOP measurements were taken with each of the three tonometers. When comparing readings over a range of ~7-77 mmHg, mean IOPs from the TV were significantly lower compared with TVP (-4.6 mmHg, p < .001) and TVA (-3.7 mmHg, p = .001). We found no significant differences between TVA and TVP measurements (p = .695). There was a moderate positive correlation between CCT and IOP for TVA (r = 0.53, p < .001), TVP (r = 0.48, p < .001), and TV (r = 0.47, p < .001). CONCLUSIONS: Our data demonstrate strong agreement between TVP and TVA, suggesting that the TVA may similarly reflect true IOP values in canines. CCT influenced IOP measurements of all three tonometers.


Asunto(s)
Enfermedades de los Perros , Glaucoma de Ángulo Abierto , Glaucoma , Animales , Perros , Enfermedades de los Perros/diagnóstico , Glaucoma/veterinaria , Glaucoma de Ángulo Abierto/veterinaria , Presión Intraocular , Manometría/veterinaria , Reproducibilidad de los Resultados , Tonometría Ocular/veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...