Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Dent Mater J ; 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39085143

RESUMEN

This study evaluated fracture resistance of monolithic fixed dental prostheses (FDPs) fabricated using different placement strategies of various connector designs in multilayered zirconia disc. Monolithic FDPs were placed in translucent and dentin layers of multilayered zirconia disc and fabricated with V-shaped and U-shaped connector designs gained by sharp and blunt millings. The FDPs were cemented on abutment models made of polymer material, underwent thermal cycles, and loaded to fracture using the universal testing machine. Fracture loads and modes were analyzed using two-way ANOVA, Tukey's post hoc test, and Fisher exact test (p≤0.05). The chosen placement strategy and connector designs gained by different milling procedures in computer-aided design/computer-aided manufacturing technology affect fracture resistance of monolithic FDPs made of multilayered zirconia materials. Placing the connector in translucent layer rather than dentin layer of multilayered zirconia disc and using sharp milling significantly reduces fracture resistance of monolithic multilayered zirconia FDPs.

2.
Clin Cosmet Investig Dent ; 16: 127-134, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38765692

RESUMEN

Background: Applying multifunctional coatings employing strontium (Sr) ions on titanium (Ti) surfaces is a useful and biocompatible method to improve osseointegration and prevent tissue infections through antimicrobial activity. Nonetheless, the effectiveness of Sr coating on the adhesion and viability of human gingival fibroblasts (HGFs) to Ti surfaces remains unclear. Purpose: The study aimed to evaluate the effect of Sr coating on the adhesion and viability of HGFs to Ti surfaces. Materials and Methods: The Ti wafers were divided into two groups based on Sr coating: uncoated Ti (control) and Sr-coated Ti. The Magnetron sputtering technique was used for Sr coating on Ti surfaces. The HGFs were seeded onto the surfaces and cultured for 48 and 96 hours before the cell adhesion and viability of the attached HGFs were assessed. The adhesion of HGFs was analyzed using the attached cell numbers at 48 h and 96 h, and the morphology at 24 h and 72 h. The cytotoxic effect on HGFs was assessed after 24 and 72 hours of incubation using cell viability assay. Student's t-test was used for statistical analysis. Results: The number of cells attached to Sr-coated surfaces was significantly greater than those attached to uncoated Ti surfaces after 48 hours (P<0.0001) and 96 hours (P=0.0002). Sr-coated and uncoated Ti surfaces were not cytotoxic to HGFs, with the cell viability ranging from 92% to 105% of the untreated control HGFs. There were no significant differences in cell viability between Sr-coated and uncoated Ti surfaces at 24 hours (P=0.3675) and 72 hours (P=0.0982). Conclusion: Sr-coated Ti surfaces induce adhesion of HGFs compared to uncoated Ti surfaces. Further, Sr-coated and uncoated Ti surfaces show no cytotoxic effect on the attached HGFs.

3.
Int J Dent ; 2024: 8410101, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38571767

RESUMEN

Objective: To evaluate the flexural strength of two translucent multilayered zirconia materials produced with different multilayer technologies. Methodology. Eighty bar-shaped zirconia specimens were prepared from two different multilayered zirconia materials (IPS e.max® ZirCAD Prime and KATANA™ Multilayered Zirconia HTML) and divided into eight groups (n = 10) based on the materials used and the individual layers of the disc for each material: Dentin Prime, Transition Prime, Translucent Prime, Multilayered Prime, Dentin HTML, Transition HTML, Translucent HTML, and Multilayered HTML. The bar-shaped zirconia specimens were cut to include all the layers from translucent to dentin In Multilayered Prime and Multilayered HTML groups. All specimens were fully sintered after cutting from multilayered zirconia discs and subjected to three-point flexural strength test using the universal testing machine. Results: The specimens made of HTML zirconia material showed significantly (P < 0.001) higher flexural strength than those made of IPS e.max® ZirCAD Prime material, with no significant difference (P > 0.05) compared to the specimens in the Dentin Prime group. The Dentin Prime specimens had the highest flexural strength (743 ± 116 MPa) compared to those in the Translucent Prime (514 ± 120 MPa), Transition Prime (575 ± 102 MPa), and Multilayered Prime (531 ± 132 MPa) groups. The flexural strength of the specimens from the individual layers of HTML zirconia material was not significantly different (P > 0.05) among the Dentin HTML (763 ± 56 MPa), Translucent HTML (791 ± 106 MPa), Transition HTML (816 ± 85 MPa), and Multilayered HTML (793 ± 102 MPa) groups. Conclusion: Multilayered zirconia materials produced with different yttria contents by layer have lower flexural strength than those produced with gradient shade technology and the same yttria content for each layer. Therefore, various factors such as the type of prostheses, nesting strategies of prostheses within the zirconia disc, and the desired aesthetical requirements should be considered when selecting the multilayered zirconia materials.

4.
Clin Cosmet Investig Dent ; 14: 61-69, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35345450

RESUMEN

Purpose: To evaluate the effect of different placing strategies performed in the connector area on fracture resistance and fracture behaviour of monolithic multi-layered translucent zirconia fixed dental prostheses (FDPs). Materials and Methods: Thirty 3-unit monolithic FDPs were produced and divided into three groups (n = 10) based on the different strategies for placing the connector area of FDPs in multi-layered zirconia blank with varying contents of yttria ranging from 4 to 5 mol%. The groups were as follows: FDPs with connectors placed in dentin layer with 4 mol% yttria content, FDPs with connectors placed in gradient layer, and FDPs with connectors placed in translucent layer with 5 mol% yttria content. A final group (n = 10) of conventional monolithic zirconia with a monolayer of yttria content (4 mol%) has been used as a control group. The specimens were artificially aged using thermocycling and pre-loading procedures and subsequently loaded to fracture using a universal testing machine. Fracture loads and fracture behaviour were analyzed using one-way ANOVA and Fisher's exact tests and statistically evaluated (p ≤ 0.05). Results: There were no significant differences in fracture loads among the groups based on the placing strategies of the connector area of the FDPs in the multi-layered translucent zirconia blank (p > 0.05). There was no significant difference in fracture loads between monolithic multi-layered translucent zirconia and conventional monolithic translucent zirconia materials (p > 0.05). Fracture behaviour of FDPs with connector area placed in translucent layer differed significantly compared to FDPs with connector area placed in dentin layer and FDPs in control group (p = 0.004). Conclusion: The placing strategies of the connector used in the computer aided design and manufacturing procedures do not considerably affect fracture resistance of monolithic FDPs made of multi-layered translucent zirconia. Monolithic FDPs made of multi-layered translucent zirconia show comparable strength to FDPs made of conventional translucent zirconia, but with different fracture behaviour.

5.
BMC Oral Health ; 21(1): 406, 2021 08 18.
Artículo en Inglés | MEDLINE | ID: mdl-34407791

RESUMEN

BACKGROUNDS: Ultraviolet light C (UVL-C) irradiation has demonstrated an antimicrobial action against various pathogens. This study aimed to evaluate the bactericidal effect of UVL-C irradiation against cariogenic oral bacteria (Streptococcus mutans) in single layers and colonies grown on solid surfaces. METHODS: Two different experiments were performed. In the first experiment, a single layer of Streptococcus mutans bacteria on agar plates was exposed to UVL-C irradiation at energies from 0 to 21 mWs/cm2. The second experiment was conducted to inhibit viability of bacterial colonies on solid surfaces. The samples were derived from saliva from a patient where bacteria were grown on plastic strips and then exposed to UVL-C. The highest energy was 1050 mWs/cm2. RESULTS: Exposure to 21 mWs/cm2 was bactericidal in single layers of Streptococcus mutans. The result for bacterial colonies on solid surfaces indicated only a bacteriostatic effect, even at energies of 1050 mWs/cm2. CONCLUSIONS: Ultraviolet light C exhibits bactericidal effects on single layers of Streptococcus mutans but has a limited effect on bacterial colonies in a biofilm. It is a matter of debate whether these in vitro results would have the same effect in clinical setting.


Asunto(s)
Caries Dental , Rayos Ultravioleta , Biopelículas , Caries Dental/prevención & control , Humanos , Streptococcus , Streptococcus mutans
6.
J Prosthodont ; 29(4): 315-322, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31971307

RESUMEN

PURPOSE: To evaluate the influence of the framework designs on the stress distribution within tooth-supported partially veneered fixed dental prostheses (FDPs) made of translucent zirconia under simulated loads using a three-dimensional finite element analysis (3D-FEA). MATERIAL AND METHODS: For a linear 3D-FEA, simplified 3D solid models of prepared abutment teeth (first premolar and first molar) with different 3-unit FDPs were created. The models with different FDP designs-monolithic zirconia (control); semi-monolithic zirconia with 0.3 mm veneer thickness (SM0.3); semi-monolithic zirconia with 0.5 mm veneer thickness (SM0.5); semi-monolithic zirconia with 0.5 mm veneer thickness supported with cap design (SMC), and semi-monolithic zirconia with 0.5 mm veneer thickness supported with wave design (SMW)-were analyzed using 3D-FEA. The elastic properties of the components (bone, dentine, cement, translucent zirconia, and veneering porcelain) were obtained from the published data for FEA. Simulated static loading forces (300 N) were applied at 10° oblique direction over six points in the occlusal surfaces of the FDPs. Maximum principal stress, shear stress, and safety factor were calculated and analyzed among the different models. RESULTS: Semi-monolithic with cap design showed the smallest maximum principal stress levels in the veneering porcelain compared to all other models (SM0.3, SM0.5, SMW). The SM0.3 had lower maximum principal stress levels in the veneering porcelain compared to SM0.5. Regarding stresses in the zirconia framework, all models had comparable results in maximum principal tensile stresses, except SMW had a lower value. Maximum principal stress levels were located in the veneer component of SM0.3, SM0.5, and SMW, whereas, such levels were observed in the cervical areas of the zirconia frameworks of SMC and control. The SM0.3 had the highest maximum shear stress levels at the zirconia-veneer interface, while SMW had the lowest shear values. The 3D-FEA models with different FDP designs showed different minimum safety factor levels. CONCLUSIONS: Framework and veneer designs play a significant role in the stress distribution of the partially veneered zirconia FDPs under loading. The FDPs with zirconia frameworks with cap design minimize the maximum principal tensile stress in the veneering porcelain. The FDPs with 0.3-mm-veneering porcelain show low maximum principal tensile stress in the veneering porcelain, but highest maximum shear stress at the zirconia-veneer interface. The FDPs with wave design of zirconia frameworks minimize the maximum shear stress considerably.


Asunto(s)
Prótesis Dental , Circonio , Porcelana Dental , Análisis del Estrés Dental , Coronas con Frente Estético , Análisis de Elementos Finitos
7.
J Prosthodont ; 28(1): 64-70, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30478870

RESUMEN

PURPOSE: To investigate the load-bearing capacity and failure mode of monolithic zirconia fixed dental prostheses (FDPs) fabricated with different connector designs and embrasure shaping methods. MATERIALS AND METHODS: Seventy four-unit zirconia FDPs (with two premolar pontics) were fabricated and divided into seven groups (n = 10) according to the different connector designs gained by using different embrasure shaping methods. The groups were as follows: monolithic FDPs fabricated with sharp embrasures, monolithic FDPs fabricated with blunt embrasures, monolithic FDPs fabricated with blunt embrasures and no occlusal embrasures, two groups of monolithic FDPs fabricated with blunt embrasures and interproximal separations made with diamond discs at the soft stage and at the fully sintered stage, and monolithic FDPs fabricated with blunt embrasures and interproximal separation accentuated by localized porcelain build-up. A final group was used as a control group, where fully veneered traditional zirconia FDPs were fabricated with default milling settings. The FDPs were artificially aged and loaded to fracture. Load to fracture and failure modes were analyzed by one-way ANOVA, Tukey's post hoc test, and Fisher exact test (α = 0.05). RESULTS: The FDPs fabricated with interproximal porcelain separation showed significantly the highest load to fracture (1038 N ± 82) of all groups (p < 0.001), with no significant difference compared to the FDPs with no occlusal embrasures (934 N ± 175; p ˃ 0.29). The FDPs fabricated with blunt embrasures showed significantly higher load to fracture (873 N ± 115) compared to the FDPs in the control group (689 N ± 75) and the FDPs with sharp embrasures (417 N ± 87; p < 0.001). There were no significant differences between the FDPs with sharp embrasures (417 N ± 87) and the FDPs with interproximal disc separations (467 N ± 94; p ˃ 0.23). Failure mode of the FDPs fabricated with sharp embrasures and interproximal disc separations differed significantly compared to the FDPs in the other groups (p < 0.001). CONCLUSIONS: Sharp embrasures and interproximal separations made with diamond discs significantly decrease the load-bearing capacity of monolithic zirconia FDPs compared to FDPs made with blunt embrasures. Blunt embrasures in combination with localized porcelain build-up produce FDPs with high load-bearing capacity in relation to loads that might be expected under clinical use.


Asunto(s)
Diseño de Implante Dental-Pilar , Materiales Dentales , Diseño de Prótesis Dental , Prótesis Dental , Itrio , Circonio , Diseño de Prótesis Dental/métodos , Análisis del Estrés Dental , Humanos , Soporte de Peso
8.
Clin Cosmet Investig Dent ; 10: 51-60, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29628778

RESUMEN

PURPOSE: The aim of this study was to describe different designs of semimonolithic crowns made of translucent and high-translucent zirconia materials and to evaluate the effect on fracture resistance and fracture mode. METHODS: One hundred crowns with different designs were produced and divided into five groups (n=20): monolithic (M), partially veneered monolithic (semimonolithic) with 0.3 mm buccal veneer (SM0.3), semimonolithic with 0.5 mm buccal veneer (SM0.5), semimonolithic with 0.5 mm buccal veneer supported by wave design (SMW), and semimonolithic with 0.5 mm buccal veneer supported by occlusal cap design (SMC). Each group was divided into two subgroups (n=10) according to the materials used, translucent and high-translucent zirconia. All crowns underwent artificial aging before loading until fracture. Fracture mode analysis was performed. Fracture loads and fracture modes were analyzed using two-way ANOVA and Fisher's exact probability tests (P≤0.05). RESULTS: SM0.3 design showed highest fracture loads with no significant difference compared to M and SMW designs (P>0.05). SM0.5 design showed lower fracture loads compared to SMW and SWC designs. Crowns made of translucent zirconia showed higher fracture loads compared to those made of high-translucent zirconia. M, SM0.3, and all but one of the SMC crowns showed complete fractures with significant differences in fracture mode compared to SMW and SM0.5 crowns with cohesive veneer fractures (P≤0.05). CONCLUSION: Translucent and high-translucent zirconia crowns might be used in combination with 0.3 mm microcoating porcelain layer with semimonolithic design to enhance the esthetic properties of restorations without significantly decreasing fracture resistance of the crowns. If 0.5 mm porcelain layer is needed for a semimonolithic crown, wave design or cap design might be used to increase fracture resistance. In both cases, fracture resistance gained is likely to be clinically sufficient as the registered fracture loads were high in relation to expected loads under clinical use.

9.
Acta Biomater Odontol Scand ; 3(1): 74-83, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29242815

RESUMEN

Objective: To evaluate fracture strength of veneered translucent zirconium dioxide crowns designed with different porcelain layer thicknesses. Materials and Methods: Sixty crowns, divided into six groups of 10, were used in this study. Groups were divided according to different thicknesses of porcelain veneer on translucent zirconium dioxide cores of equal thickness (0.5 mm). Porcelain thicknesses were 2.5, 2.0, 1.0, 0.8, 0.5 and 0.3 mm. Crowns were artificially aged before loaded to fracture. Determination of fracture mode was performed using light microscope. Results: Group 1.0 mm showed significantly (p ≤ .05) highest fracture loads (mean 1540 N) in comparison with groups 2.5, 2.0 and 0.3 mm (mean 851, 910 and 1202 N). There was no significant difference (p>.05) in fracture loads among groups 1.0, 0.8 and 0.5 mm (mean 1540, 1313 and 1286 N). There were significantly (p ≤ .05) more complete fractures in group 0.3 mm compared to all other groups which presented mainly cohesive fractures. Conclusions: Translucent zirconium dioxide crowns can be veneered with minimal thickness layer of 0.5 mm porcelain without showing significantly reduced fracture strength compared to traditionally veneered (1.0-2.0 mm) crowns. Fracture strength of micro-veneered crowns with a layer of porcelain (0.3 mm) is lower than that of traditionally veneered crowns but still within range of what may be considered clinically sufficient. Porcelain layers of 2.0 mm or thicker should be used where expected loads are low only.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA