Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Ann Vasc Surg ; 67: 274-282, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32209404

RESUMEN

BACKGROUND: The aim of the present study was to evaluate early-, mid-, and long-term outcomes in an unselected population of patients treated for abdominal aortic aneurysms (AAAs) by endovascular aneurysm repair (EVAR) with different commercially available off-the-shelf devices. MATERIALS AND METHODS: A retrospective study was conducted on a prospectively compiled computerized database on patients presenting an infrarenal AAA treated between January 2008 and December 2015 in a high-volume Italian tertiary referral Center. Demographic, clinical, and specific morphological features were considered as potentially influencing the outcomes and the type of the implanted device. Outcome measures were procedure-related reintervention, AAA-related, and all-cause mortality rates at 30-day, 12-month, and long-term follow-up. Reinterventions considered for the analysis were AAA rupture, graft infection, type I or III endoleaks, type II endoleaks with sac enlargement > 5 mm, graft stenosis or occlusions, procedures related to renal or visceral ischemia, and reintervention for access vessel injury. RESULTS: Of 498 EVAR procedures performed for elective infrarenal AAA treatment during the entire study period, 479 patients were enrolled, the mean age was 73.5 ± 7.34 years (range 51-91), and 416 (86.84%) were men. The mean maximum AAA diameter was 52.02 ± 8.04 mm (range 39-90.2), a maximum AAA diameter ≥59 mm was recorded in 107 patients (22.33%), and an aortic neck length was <10 mm in 137 (28.60%). Technical success was achieved in all patients. At a mean follow-up of 52.97 ± 26.16 months (range 1-120), overall reintervention and death rates were 8.14% and 20.04%, respectively, without AAA-related deaths. At univariate analysis, hypertension was the only demographical variable found to be associated with higher risk of reintervention, P = 0.04 (OR: 2.34; CI 95%: 1.00-5.42). Furthermore, male sex (P = 0.02; OR: 2.62; CI 95%: 1.09-6.27) and chronic renal insufficiency (P = 0.003; OR: 2.08; CI 95%: 1.27-3.42) were associated with higher mortality rates. AAA diameter ≥59 mm was statistically associated with a higher rate of both reintervention and mortality: P < 0.001 (OR: 9.05; CI 95%: 4.52-18.11) and <0.001 (4.00; 2.46-6.49), respectively. CONCLUSIONS: Our experience seems to suggest that EVAR could be safely and effectively performed in an unselected patients' population, with encouraging results up to a ten-year follow-up.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Bases de Datos Factuales , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Ciudad de Roma , Stents , Factores de Tiempo , Resultado del Tratamiento
2.
Ann Vasc Surg ; 60: 479.e5-479.e9, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31195105

RESUMEN

We report a case of an 18-year-old woman who developed a delayed pseudoaneurysm of the right anterior tibial artery (ATA), 14 days after a knife accidental trauma. The patient was admitted to our emergency department for acute onset of pain in the right limb after a domestic trauma. At a physical examination, the limb was tense and tender, with a pulsatile mass in the anterior compartment. Femoral, popliteal, and distal pulses were palpable on both limbs. Duplex ultrasound scan (DUS) and computed tomography angiography showed the presence of an ATA pseudoaneurysm. An urgent endovascular treatment was performed under local anesthesia via percutaneous access. Pseudoaneurysm was excluded implanting 2 coronary covered balloon-expandable stents (BeGraft; Bentley Innomed GmbH, Hechingen, Germany). Postoperative course was uneventful and the patient was discharged on the second postoperative day under dual antiplatelet therapy. One- and 13-month scheduled follow-up visits and DUS revealed the presence of a normal pedal pulse, complete pseudoaneurysm exclusion, and patency of the stent grafts and the entire ATA with triphasic waveforms. In conclusion, endovascular treatment of an ATA pseudoaneurysm seems to be a feasible option. Further experience with this technique is needed to validate its safety and long-term patency, especially in young and healthy subjects.


Asunto(s)
Aneurisma Falso/terapia , Angioplastia de Balón , Arterias Tibiales/lesiones , Lesiones del Sistema Vascular/terapia , Heridas Punzantes/complicaciones , Adolescente , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Angioplastia de Balón/instrumentación , Femenino , Humanos , Stents , Arterias Tibiales/diagnóstico por imagen , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Heridas Punzantes/diagnóstico
3.
Ann Vasc Surg ; 53: 271.e1-271.e5, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30092428

RESUMEN

We report an unusual complication of Chocolate nitinol-constraining structure after right superficial femoral artery (SFA) angioplasty. The procedure was performed by vascular surgeons in an operating theater equipped by a portable fluoroscopy unit. Under local anesthesia, by a contralateral approach, a 7F introducer sheath was advanced through the proximal portion of the right common iliac artery. Owing to the severe aorto-iliac vessels calcification, it was not possible to place the introducer sheath into a more distal vessel, as planned. After external iliac artery (EIA) stenting (7 × 80 mm Eluvia), SFA obstruction was intraluminal crossed, and a 6 × 120 mm nitinol-constrained balloon (Chocolate; Medtronic) was advanced in place and inflated. Once the balloon came out, the nitinol-constraining structure was not attached to the balloon surface. Under fluoroscopy, the crashed nitinol mesh was identified at distal edge of previously positioned EIA stent. To prevent mesh migration, it was fixed by covering with a 7 × 40 mm stent. The procedure was then successfully completed, as planned. One-month, postoperative computed tomography angiography showed complete expansion of the stents and no significant residual stenosis (>30%) in EIA, and SFA. Chocolate's mesh was still evident between the stent and the iliac artery wall, in absence of further complications. A 3 months follow-up, patient was still completely asymptomatic for claudication.


Asunto(s)
Aleaciones , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/instrumentación , Arteria Femoral/cirugía , Arteria Ilíaca/cirugía , Enfermedad Arterial Periférica/cirugía , Stents , Anciano , Angiografía por Tomografía Computarizada , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/fisiopatología , Masculino , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento , Grado de Desobstrucción Vascular
4.
Ann Ital Chir ; 88: 190-192, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28874626

RESUMEN

The knowledge of both normal and abnormal anatomy of the veins of the neck may be important for surgeons performing neck surgery, to avoid inadvertent injury to vascular structures. In a 75-year-old man candidated to carotid endarterectomy preoperative CT-scan showed a rare anomaly of the venous drainage in the area of the anterior jugular vein (AJV), that usually begins in the suprahyoid region via the confluence of several superficial veins, to open into the ipsilateral external jugular vein. A large left sided venous trunk, originating from an anomalous proximal confluence with the internal jugular vein, descended in the AJV anatomical position, to cross over the sternum draining into the right subclavian vein. The knowledge of this abnormal anatomy allowed to perform a safe carotid bulb isolation avoiding inadvertent injury to vascular structures. KEY WORDS: Anatomic variations, Anterior jugular vein, Jugular veins, Carotid endarterectomy, Neck surgery.


Asunto(s)
Venas Yugulares/anomalías , Cuello/irrigación sanguínea , Vena Subclavia/anomalías , Anciano , Variación Biológica Poblacional , Endarterectomía Carotidea , Humanos , Complicaciones Intraoperatorias/prevención & control , Venas Yugulares/diagnóstico por imagen , Masculino , Cuello/diagnóstico por imagen , Cuello/cirugía , Cuidados Preoperatorios , Vena Subclavia/diagnóstico por imagen , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...