Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JACC Cardiovasc Interv ; 6(4): 325-33, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23523453

RESUMEN

OBJECTIVES: This study sought to report the final 5-year outcomes of the ENDEAVOR IV (A Randomized, Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Taxus Paclitaxel-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) trial comparing the Endeavor zotarolimus-eluting stent (E-ZES) (Medtronic, Santa Rosa, California) with the Taxus paclitaxel-eluting stent (PES) (Boston Scientific, Natick, Massachusetts) in patients with single de novo coronary lesions. BACKGROUND: Primary results of the ENDEAVOR IV trial demonstrated similar clinical outcomes with E-ZES and PES. Concerns with regard to late adverse clinical events with drug-eluting stents highlight the need for long-term follow-up with these devices. METHODS: Late outcomes after the use of E-ZES and PES were examined in the multicenter randomized ENDEAVOR IV trial in cumulative and landmark analyses. Assessed outcomes were related to device efficacy and patient safety. RESULTS: At 5 years, clinical data were available for 722 (93.4%) E-ZES patients and 718 (92.6%) PES patients. Overall rates of target lesion revascularization (7.7% vs. 8.6%, p = 0.70) and target vessel failure were similar (17.2% vs. 21.1%, p = 0.061) with E-ZES compared with PES. The incidence of cardiac death or myocardial infarction (MI) was lower with E-ZES (6.4% vs. 9.1%, p = 0.048), primarily driven by a lower rate of target vessel MI with E-ZES (2.6% vs. 6.0%, p = 0.002). Although overall definite/probable stent thrombosis rates were similar between stents (1.3% vs. 2%, p = 0.42), rates of very late stent thrombosis (0.4% vs. 1.8%, p = 0.012) and late MI events (1.3% vs. 3.5%, p = 0.008) were significantly lower with E-ZES compared with PES. CONCLUSIONS: These data demonstrate the durable efficacy and safety of E-ZES compared with PES for the treatment of de novo coronary lesions. Significant improvements in late safety outcomes were observed with E-ZES but should be considered hypothesis-generating, given the limited statistical power of the trial. (The ENDEAVOR IV Clinical Trial: A Trial of a Coronary Stent System in Coronary Artery Lesions; NCT00217269).


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Anciano , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Trombosis Coronaria/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Método Simple Ciego , Sirolimus/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
2.
J Am Coll Cardiol ; 56(4): 264-71, 2010 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-20493653

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the safety and efficacy of the novel platinum chromium TAXUS Element paclitaxel-eluting stent (PES) compared with the TAXUS Express PES (Boston Scientific, Natick, Massachusetts) in treating coronary artery stenoses. BACKGROUND: The TAXUS Element is a novel thin-strut (81 microm), platinum chromium alloy PES designed to improve radial strength, radiopacity, and deliverability, while safely providing comparable restenosis benefit compared with a previous-generation PES. METHODS: The PERSEUS (Prospective Evaluation in a Randomized Trial of the Safety and Efficacy of the Use of the TAXUS Element Paclitaxel-Eluting Coronary Stent System) Workhorse (WH) trial is a prospective, randomized (3:1), controlled, multicenter study of the TAXUS Element (vs. TAXUS Express) PES for the treatment of de novo coronary atherosclerotic lesionsor=2.75 to

Asunto(s)
Aleaciones de Cromo/administración & dosificación , Angiografía Coronaria/normas , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/tratamiento farmacológico , Stents Liberadores de Fármacos/normas , Paclitaxel/administración & dosificación , Anciano , Cromo/administración & dosificación , Cromo/efectos adversos , Aleaciones de Cromo/efectos adversos , Stents Liberadores de Fármacos/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Platino (Metal)/administración & dosificación , Platino (Metal)/efectos adversos , Estudios Prospectivos , Método Simple Ciego , Resultado del Tratamiento
3.
J Am Coll Cardiol ; 55(6): 543-54, 2010 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-20152559

RESUMEN

OBJECTIVES: The ENDEAVOR IV (Randomized Comparison of Zotarolimus-Eluting and Paclitaxel-Eluting Stents in Patients with Coronary Artery Disease) trial evaluated the safety and efficacy of the zotarolimus-eluting stent (ZES) compared with the paclitaxel-eluting stent (PES). BACKGROUND: First-generation drug-eluting stents have reduced angiographic and clinical restenosis, but long-term safety remains controversial. A second-generation drug-eluting stent, which delivers zotarolimus, a potent antiproliferative agent, via a biocompatible phosphorylcholine polymer on a cobalt alloy thin-strut stent has shown promising experimental and early clinical results. METHODS: This is a prospective, randomized (1:1), single-blind, controlled trial comparing outcomes of patients with single de novo coronary lesions treated with ZES or PES. The primary end point was noninferiority of 9-month target vessel failure defined as cardiac death, myocardial infarction, or target vessel revascularization. RESULTS: Among a total of 1,548 patients assigned to ZES (n = 773) or PES (n = 775), at 9 months, ZES was noninferior to PES with rates of target vessel failure 6.6% versus 7.1%, respectively (p(noninferiority) < or = 0.001). There were fewer periprocedural myocardial infarctions with ZES (0.5% vs. 2.2%; p = 0.007), whereas at 12 months, there were no significant differences between groups in rates of cardiac death, myocardial infarction, target vessel revascularization, or stent thrombosis. Although incidence of 8-month binary angiographic in-segment restenosis was higher in patients treated with ZES versus PES (15.3% vs. 10.4%; p = 0.284), rates of 12-month target lesion revascularization were similar (4.5% vs. 3.2%; p = 0.228), especially in patients without planned angiographic follow-up (3.6% vs. 3.2%; p = 0.756). CONCLUSIONS: These findings demonstrate that ZES has similar clinical safety and efficacy compared with PES in simple and medium complexity single de novo coronary lesions. (ENDEAVOR IV Clinical Trial; NCT00217269).


Asunto(s)
Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Stents Liberadores de Fármacos , Inmunosupresores/administración & dosificación , Paclitaxel/administración & dosificación , Sirolimus/análogos & derivados , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Método Simple Ciego , Sirolimus/administración & dosificación , Resultado del Tratamiento
4.
J Am Coll Cardiol ; 48(12): 2440-7, 2006 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-17174180

RESUMEN

OBJECTIVES: This trial examined the relative clinical efficacy, angiographic outcomes, and safety of zotarolimus-eluting coronary stents (ZES) with a phosphorylcholine polymer versus sirolimus-eluting stents (SES). BACKGROUND: Whether a cobalt-based alloy stent coated with the novel antiproliferative agent, zotarolimus, and a phosphorylcholine polymer may provide similar angiographic and clinical benefit compared with SES is undetermined. METHODS: A prospective, multicenter, 3:1 randomized trial was conducted to evaluate the safety and efficacy of ZES (n = 323) relative to SES (n = 113) in 436 patients undergoing elective percutaneous revascularization of de novo native coronary lesions with reference vessel diameters between 2.5 mm and 3.5 mm and lesion length > or =14 mm and < or =27 mm. The primary end point was 8-month angiographic in-segment late lumen loss. RESULTS: Angiographic in-segment late lumen loss was significantly higher among patients treated with ZES compared with SES (0.34 +/- 0.44 mm vs. 0.13 +/- 0.32 mm, respectively; p < 0.001). In-hospital major adverse cardiac events were significantly lower among patients treated with ZES (0.6% vs. 3.5%, p = 0.04). In-segment binary angiographic restenosis was also higher in the ZES cohort (11.7% vs. 4.3%, p = 0.04). Total (clinically and non-clinically driven) target lesion revascularization rates at 9 months were 9.8% and 3.5% for the ZES and SES groups, respectively (p = 0.04). However, neither clinically driven target lesion revascularization (6.3% zotarolimus vs. 3.5% sirolimus, p = 0.34) nor target vessel failure (12.0% zotarolimus vs. 11.5% sirolimus, p = 1.0) differed significantly. CONCLUSIONS: Compared with SES, treatment with a phosphorylcholine polymer-based ZES is associated with significantly higher late lumen loss and binary restenosis at 8-month angiographic follow-up. (The Endeavor III CR; http://clinicaltrials.gov/ct/show/NCT00265668?order=1?).


Asunto(s)
Estenosis Coronaria/tratamiento farmacológico , Inmunosupresores/administración & dosificación , Sirolimus/análogos & derivados , Sirolimus/administración & dosificación , Stents , Anciano , Sistemas de Liberación de Medicamentos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...