1.
J Mater Sci Mater Med ; 24(3): 597-610, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23242766

RESUMEN

The bioactivity of calcium phosphate bone grafts of varying chemistry and strut-porosity was compared by determining the rate of formation of hydroxycarbonate apatite crystals on the material surface after being soaked in simulated body fluid for up to 30 days. Three groups of silicate-substituted hydroxyapatite material were tested, with each group comprising a different quantity of strut-porosity (23, 32, and 46 % volume). A commercially available porous ß-tricalcium phosphate bone graft substitute was tested for comparison. Results indicate that strut-porosity of a material affects the potential for formation of a precursor to bone-like apatite and further confirms previous findings that ß-tricalcium phosphate is less bioactive than hydroxyapatite.


Asunto(s)
Apatitas/química , Sustitutos de Huesos , Fosfatos de Calcio/química , Microscopía Electrónica de Rastreo , Difracción de Rayos X