Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Int AIDS Soc ; 24(2): e25669, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33619853

RESUMEN

INTRODUCTION: HIV incidence estimates are important to characterize the status of an epidemic, identify locations and populations at high risk and to guide and evaluate HIV prevention interventions. We used the limiting antigen avidity assay (LAg) as part of a recent infection testing algorithm to estimate HIV incidence in the Akwa Ibom AIDS Indicator Survey (AKAIS), Nigeria. METHODS: In 2017, AKAIS, a cross-sectional population-based study was conducted at the household (HH) level in 31 local government areas (LGAs) of Akwa Ibom state. Of the 8963 participants aged ≥15 years who were administered questionnaires for demographic and behavioural data, 8306 consented to HIV rapid testing. Whole-blood specimens were collected from 394 preliminary HIV-seropositive individuals for CD4+ cell count determination and plasma storage. Samples were shipped to a central quality laboratory for HIV confirmatory testing and viral load determination. A total of 370 HIV-positive specimens were tested for the recent HIV infection using the LAg assay. RESULTS: Of the 8306 consenting adults, the HIV prevalence was 4.8%. Of the 370 HIV-positive samples tested for HIV recency, the median age was 35 years, 48.8% had CD4+ cell count >500/mm3 and 81.3% was not virally suppressed. Viral suppression was greater among females (21%) than for males (13%). A total of 11 specimens were classified as recent based on the LAg assay and HIV viral load ≥1000 copies/mL. The weighted, adjusted HIV-1 incidence was 0.41/100 person-years (95% CI 0.16 to 0.66); translating to 13,000 new cases of HIV infections annually in Akwa Ibom, a state with a population of 5.5 million. The HIV incidence rate was similar in females and males (0.41% and 0.42% respectively). The incidence rate was the highest among participants aged 15 to 49 years (0.44%, 95% CI 0.15 to 0.74) translating to 11,000 new infections annually, about 85% of all new infections in the state. CONCLUSIONS: The finding of the high HIV incidence among the 15 to 49-year age group calls for renewed and innovative efforts to prevent HIV infection among young adults in Akwa Ibom state.


Asunto(s)
Infecciones por VIH/epidemiología , Seropositividad para VIH/diagnóstico , VIH-1/inmunología , Técnicas para Inmunoenzimas/métodos , Adolescente , Adulto , Fármacos Anti-VIH/uso terapéutico , Afinidad de Anticuerpos/inmunología , Estudios Transversales , Femenino , Anticuerpos Anti-VIH/sangre , Anticuerpos Anti-VIH/inmunología , Antígenos VIH/inmunología , Infecciones por VIH/diagnóstico , Infecciones por VIH/tratamiento farmacológico , Seropositividad para VIH/sangre , Seropositividad para VIH/inmunología , VIH-1/aislamiento & purificación , Humanos , Incidencia , Recién Nacido , Masculino , Persona de Mediana Edad , Nigeria/epidemiología , Encuestas y Cuestionarios , Carga Viral , Adulto Joven
2.
PLoS One ; 12(5): e0178037, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28542359

RESUMEN

BACKGROUND: Despite the upsurge in support and intervention of donor agencies in HIV care and treatment programing in Sub-Sahara African, antiretroviral (ART) programs are still confronted with access and coverage challenges which influence enrolment of new patients. This study investigated the validity of point of care BD FACSPresto™ CD4 analyzer for CD4+ cell count, overall agreement, correlation, sensitivity, and specificity in comparison to a reference standard flow cytometry method. We also assessed the feasibility of use among non-laboratorians. METHODS: Blood samples from 300 HIV infected individuals were analyzed for CD4+ T cell and CD4%, using finger prick capillary sample from 150 PMTCT clients and 150 ART clients at Murtala Mohammed Specialist Hospital, Kano, Nigeria. Their venous samples were compared on a flow cytometry reference method using BD FACSCount CD4+ count system. The accuracy of the BD FACSPresto machine in comparison to BD FACSCount was evaluated. Statistical analysis was carried out using STATA (version 12). Bland-Altman method and correlation analysis were used to analyze agreement between both measurements. In addition, sensitivity and specificity of both measurements were determined. Statistical significance was set at p-value <0.05. RESULTS: The mean bias and limit of agreement for CD4+ count between BD FACSPresto and BD FACS count machine were 7.49 (95% CI: 2.44 to 12.54) and -8.14 to 96.39 respectively. Further analysis revealed close agreement between BD FACSPresto and BD FACSCount with no significant difference between the two methods (p = .0.95). Using a threshold of 500 cells/µL, sensitivity and specificity of BD FACSPresto were 95.1% and 97.1% respectively, compared to BD FACSCount. There was no statistically significant difference in the misclassification between BD FACSPresto and BD FACSCount results (p = 0.23). Furthermore, sensitivity and specificity were similar when BD FACSPresto machine was operated by a nurse or laboratory scientist, there was no substantial difference in testing variability observed between laboratory and non-laboratory operators using the BD FACSPresto analyzer. CONCLUSIONS: Overall, BD FACSPresto Point of Care CD4+ count finger stick capillary blood results is a reliable method in comparison to venous sample cytometry method and no significant difference variability observed between laboratory personnel and non-laboratory operators. The BD FACSPresto is simple, more robust and easy to use equipment without significant variability in reliability by non-laboratory health care workers hence will be a valuable instrument in increasing access and coverage of CD4 estimations in developing countries. The introduction of the BD FACSPresto POC analyzer has a high potential in reducing patients waiting time and improving the overall quality of ART service and clients' satisfaction especially in rural settings.


Asunto(s)
Linfocitos T CD4-Positivos/inmunología , Linfocitos T CD4-Positivos/fisiología , Infecciones por VIH/sangre , Infecciones por VIH/inmunología , Adolescente , Adulto , Anciano , Recolección de Muestras de Sangre/métodos , Recuento de Linfocito CD4/métodos , Países en Desarrollo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nigeria , Sistemas de Atención de Punto , Reproducibilidad de los Resultados , Población Rural , Sensibilidad y Especificidad , Adulto Joven
3.
PLoS One ; 9(9): e107277, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25211131

RESUMEN

BACKGROUND: The surge of donor funds to fight HIV&AIDS epidemic inadvertently resulted in the setup of laboratories as parallel structures to rapidly respond to the identified need. However these parallel structures are a threat to the existing fragile laboratory systems. Laboratory service integration is critical to remedy this situation. This paper describes an approach to quantitatively measure and track integration of HIV-related laboratory services into the mainstream laboratory services and highlight some key intervention steps taken, to enhance service integration. METHOD: A quantitative before-and-after study conducted in 122 Family Health International (FHI360) supported health facilities across Nigeria. A minimum service package was identified including management structure; trainings; equipment utilization and maintenance; information, commodity and quality management for laboratory integration. A check list was used to assess facilities at baseline and 3 months follow-up. Level of integration was assessed on an ordinal scale (0 = no integration, 1 = partial integration, 2 = full integration) for each service package. A composite score grading expressed as a percentage of total obtainable score of 14 was defined and used to classify facilities (≤ 80% FULL, 25% to 79% PARTIAL and <25% NO integration). Weaknesses were noted and addressed. RESULTS: We analyzed 9 (7.4%) primary, 104 (85.2%) secondary and 9 (7.4%) tertiary level facilities. There were statistically significant differences in integration levels between baseline and 3 months follow-up period (p<0.01). Baseline median total integration score was 4 (IQR 3 to 5) compared to 7 (IQR 4 to 9) at 3 months follow-up (p = 0.000). Partial and fully integrated laboratory systems were 64 (52.5%) and 0 (0.0%) at baseline, compared to 100 (82.0%) and 3 (2.4%) respectively at 3 months follow-up (p = 0.000). DISCUSSION: This project showcases our novel approach to measure the status of each laboratory on the integration continuum.


Asunto(s)
Laboratorios/organización & administración , Infecciones por VIH/diagnóstico , Infecciones por VIH/terapia , Humanos , Laboratorios/normas , Nigeria , Evaluación de Procesos, Atención de Salud , Mejoramiento de la Calidad , Integración de Sistemas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...