1.
Radiother Oncol ; 79(3): 335-40, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16781790

RESUMEN

BACKGROUND AND PURPOSE: Patients receiving radical radiotherapy to the prostate are requested to maintain a full bladder to displace the dome of the bladder and small bowel from the target volume. This study investigated patients' ability to consistently maintain a full bladder throughout planning and treatment before (Study 1) and after (Study 2) the introduction of a patient information sheet. PATIENTS AND METHODS: Bladder volumes were measured on 41 patients at CT scanning, simulation and once weekly during treatment using a portable ultrasound device, BladderScan BVI 3000. Patients were asked their assessment of bladder fullness, time since last urination and the volume of fluid drank. A patient information sheet on bladder filling was then introduced and the study repeated on 25 patients (Study 2). The ultrasound bladder volumes measured at CT were compared to the CT scan data. RESULTS: There was a strong correlation between the ultrasound and CT bladder volumes r = 0.88 (P < 0.01). There was a significant decrease between the volume at CT (mean 362 ml, SD 229 ml) and treatment (mean 251 ml, SD 171 ml) in Study 1 (P = 0.002). In Study 2 the mean volume at CT was 286 ml (SD 164 ml) compared to a mean of 312 ml (SD 196 ml) during treatment. The measured volume correlated with patient self-assessment (r = 0.47, P < 0.01). The median volume drank by patients in Study 2 was 350 ml (range 50-825 ml) compared to 450 ml (range 75-1500 ml) in Study 1. CONCLUSIONS: Our initial results showed patients were unable to maintain a constant bladder volume during planning and treatment. Implementation of written bladder filling instructions was shown to improve bladder volume consistency.


Asunto(s)
Fraccionamiento de la Dosis de Radiación , Tamaño de los Órganos , Neoplasias de la Próstata/radioterapia , Vejiga Urinaria/diagnóstico por imagen , Ingestión de Líquidos , Humanos , Masculino , Variaciones Dependientes del Observador , Cooperación del Paciente , Radiografía , Ultrasonografía
2.
Radiother Oncol ; 70(1): 1-10, 2004 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15036846

RESUMEN

BACKGROUND AND PURPOSE: Two systems have been developed for treating patients with locally advanced prostate cancer using intensity-modulated radiotherapy (IMRT): one using dynamic multi-leaf collimator delivery and the other using step-and-shoot. This paper describes the clinical implementation of these two techniques, and presents results from the first 14 patients treated in a clinical setting (nine dynamic, five step-and-shoot). PATIENTS AND METHODS: Dynamic treatments were planned using Corvus, and step-and-shoot using Helax-TMS; all were delivered using Elekta accelerators. Prior to the first clinical treatments, validation measurements were carried out for each system, including measurements for a complete IMRT treatment. The reproducibility of dynamic delivery and the characteristics of the accelerator for low-monitor-unit (MU) deliveries were also assessed. An extensive quality assurance (QA) program was performed for each of the patients. Additionally, timing measurements were carried out to assess the practicalities of the technique. RESULTS: The planning objectives were met in most cases. Absolute doses for complete IMRT treatments were within 2%, on average, with dose distributions generally showing agreement within 3% or 3 mm. Beam modulation measurements made throughout each patient's treatment indicated that both delivery methods were reproducible. The dynamic plans required an average of 765 MU per beam, with a treatment delivery time of 14 min; corresponding results for step-and-shoot plans were 105 MU and 10 min. CONCLUSIONS: Two IMRT techniques for this group of patients have been successfully implemented in the clinic. The more complex dynamic treatments showed no advantages over the step-and-shoot approach. QA results have shown accurate and reproducible delivery for both techniques, giving increased confidence in the techniques and allowing a reduction in the QA program.


Asunto(s)
Ganglios Linfáticos/patología , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Masculino , Pelvis , Garantía de la Calidad de Atención de Salud , Radioterapia/métodos , Reproducibilidad de los Resultados , Resultado del Tratamiento