Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Front Cardiovasc Med ; 11: 1418059, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39149585

RESUMEN

Atrial fibrillation (AF) represents the most common cardiac arrhythmia with significant morbidity and mortality implications. It is a common cause of hospital admissions, significantly impacts quality of life, increases morbidity and decreases life expectancy. Despite advancements in treatment options, prevalence of AF remains exceptionally high. AF is a challenging disease to manage, not just clinically but also financially. Evidence suggests lifestyle modification, including dietary changes, plays a significant role in the treatment of AF. This review aims to analyze the existing literature on the effects of dietary modifications on the incidence, progression, and outcomes of atrial fibrillation. It examines various dietary components, including alcohol, caffeine, omega-3 polyunsaturated fatty acids and minerals, and their impact on AF incidence, progression, and outcomes. The evidence surrounding the effects of dietary patterns, such as the Mediterranean and low carbohydrate diets, on AF is also evaluated. Overall, this review underscores the importance of dietary interventions as part of a comprehensive approach to AF management and highlights the need for further research in this emerging field.

3.
Proc (Bayl Univ Med Cent) ; 37(1): 6, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38174014
4.
J Cardiovasc Electrophysiol ; 35(3): 511-515, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38225537

RESUMEN

INTRODUCTION: Atrial fibrillation and atrial flutter originating from the donor s heart is a commonly reported complication post heart transplant. Atrial tachyarrhythmia originating from the recipient s heart, propagated through recipient-to-donor connections, is rare with only few cases reported in the literature; most reported cases from our review occur years post-transplant. CASE: A 47-year-old male presented with atrial tachycardia 6 months post heart transplant. Electrophysiologic study demonstrated atrial fibrillation originating from native heart and propagated through atrio-atrial connections to the donor heart. This arrhythmia was successfully terminated with radiofrequency ablation. CONCLUSION: Atrio-atrial connection between recipient and donor can form as early as a few months post heart transplant. Radiofrequency ablation appears to be an effective treatment for atrial fibrillation propagated through donor-to-recipient connections.


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Trasplante de Corazón , Masculino , Humanos , Persona de Mediana Edad , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Trasplante de Corazón/efectos adversos , Ablación por Catéter/efectos adversos , Donantes de Tejidos , Aleteo Atrial/diagnóstico , Aleteo Atrial/etiología , Aleteo Atrial/cirugía
5.
Proc (Bayl Univ Med Cent) ; 36(6): 744, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37829211
7.
Ochsner J ; 21(1): 25-29, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33828423

RESUMEN

Background: The impact of web-based patient portals on patient outcomes-specifically hospital readmissions in patients with atrial fibrillation (AF)-remains understudied. Methods: This single-center retrospective cohort study investigated the use of an online portal system (MyChart) by patients hospitalized from January 1, 2014 to June 30, 2017 for AF. During the study period, 11,334 unique AF admissions were identified; 50.3% were MyChart users and 49.7% were non-MyChart users. Patients who experienced inpatient mortality were excluded. The study groups were analyzed for demographic variables, comorbidities, readmission rates, and the frequency of MyChart use during the 3.5-year time frame. Results: MyChart users were younger (median age, 74 years, interquartile range [IQR] 66-82 vs 77 years, IQR 68-85; P<0.0001) and more likely to be white (91.9% vs 84.6%; P<0.0001), but the sex distribution was similar between groups, with 51.8% males in the MyChart group vs 53.2% in the non-MyChart group. MyChart users had a significantly higher rate of readmission compared to non-MyChart users at 1 year (43.0% vs 32.0%, respectively; P<0.0001). MyChart users who were readmitted had a higher median number of logins to MyChart (121 [IQR 32-270.5]) than MyChart users who were not readmitted (91 [IQR 26-205]; P<0.0001). Multivariable regression analysis demonstrated that MyChart use was associated with readmission (odds ratio 1.57, 95% CI 1.49-1.70; P<0.0001). Conclusion: Among patients with AF, MyChart use was associated with higher readmissions in this single-center cohort. Use and benefit of bespoke portals require further study.

8.
J Interv Card Electrophysiol ; 61(1): 137-144, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32504227

RESUMEN

PURPOSE: As left atrial appendage occlusion devices (LAAO) implantation rates grow, continued evaluation on best patient practices is important. We report pooled Watchman outcomes at a multicenter Texas healthcare system with an emphasis on clinical outcomes and post-implantation anticoagulation with direct oral anticoagulants (DOACs) versus warfarin. METHODS: Data for 163 patients with atrial fibrillation (AF) undergoing Watchman implantation was collected via retrospective chart review between June 2016 and June 2018. A Fisher's exact test was utilized to evaluate associations in bivariate comparisons of categorical data. Tests of non-inferiority, applied between DOACs and warfarin, utilized a ratio of 2. RESULTS: Outcomes were significant for similar rates of stroke, disabling stroke, major bleeds, and all-cause mortality when compared to published clinical trials. Most patients with cerebrovascular events were found to have >5 mm peri-device leaks (PDLs), were on warfarin at the time of the event (75%), and all occurred within the first 6 months post implant. A significant number of patients were discharged on DOACs (42%). DOACs were shown to be non-inferior to warfarin with respect to stroke (p = 0.0048), disabling stroke (p = 0.0383), gastrointestinal bleeding (p = 0.0287), mortality (p = 0.0165), and combined adverse outcomes (p = 0.0040). DOACs were associated with less combined adverse outcomes (p = 0.021). CONCLUSION: Our findings suggest that additional imaging or aggressive management of PDLs in Watchman recipients within the initial 6-month follow-up may aid in reducing stroke rates. Additionally, anticoagulation with DOACs' post Watchman implantation was found non-inferior to warfarin, with some evidence of lower risk for adverse outcomes favoring DOACs.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Administración Oral , Anticoagulantes/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Humanos , Estudios Retrospectivos , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento , Warfarina/uso terapéutico
9.
J Innov Card Rhythm Manag ; 10(5): 3652-3661, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-32477730

RESUMEN

Temporary cardiac pacing is commonly used in patients with life-threatening bradycardia and serves as a bridge to implantation of a permanent pacemaker (PPM). For years, passive fixation leads have been used for this purpose, offering the advantage of that they can be placed at bedside. The downside, however, is that patients must remain on telemetry and bed rest until lead removal due to the risk of displacement and failure to capture. Even then, the latter cannot always be prevented. Temporary cardiac pacing with passive fixation leads has also been related to a higher incidence of infection and venous thrombosis, delayed recovery, and increased length of stay. Thus, over the last couple of decades, pacemaker leads with an active fixation mechanism have become increasingly used. This is known as a temporary PPM (TPPM) approach, which carries a very low risk of lead dislodgement and allows patients to ambulate, among other advantages. Here, we performed a review of the literature on the use of TPPMs and their advantages over temporary pacemakers with passive fixation leads and in order to evaluate the advantages and disadvantages of active and passive fixation leads in temporary cardiac pacing. Most articles found were case reports and case series, with few prospective studies. We excluded documents such as editorials and image case reports that provided little to no useful information for the final analysis. The literature search was performed in PubMed, Google Scholar, and other databases and articles written in English and Spanish were considered. Articles were screened up to January 2017. The search keywords used were "temporary permanent pacemaker," "external permanent pacemaker," "active fixation lead," "explantable pacemaker," "hybrid pacing," "temporary permanent generator," "prolonged temporary transvenous pacing," and "semipermanent pacemaker." A total of 24 studies with 770 patients were ultimately included in our review. The age group was primarily above the sixth decade of life, with the exception of one that included pediatric patients. Indications for pacing included device infection, sick sinus syndrome, atrioventricular block, ventricular tachycardia, and bradyarrhythmias associated with systemic illness. The duration of TPPM usage varied from a few days up to 336 days. A total of 18 (2.3%) TPPM-related infections were reported, in which the duration of TPPM use was less than 30 days in at least 15 patients. Loss of capture was documented in only eight patients (1.0%). Complication rates varied from 0% to 30%, with the highest event rates being present in studies that used femoral venous access. In conclusion, although no high-quality studies were identified in our literature search, we found the data retrieved suggest the association of overall favorable outcomes with the use of TPPMs. Device placement and removal typically involve a simple procedure, although fluoroscopy, usually applied in the cardiac catheterization laboratory, is necessary for implantation, which could represent an additional risk in a patient who is already hemodynamically unstable. When possible, a screw-in-lead pacemaker should be used for temporary pacing.

12.
Pacing Clin Electrophysiol ; 41(11): 1568-1571, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-29956361

RESUMEN

Cardiac resynchronization therapy device implantation is complicated by a significant rate of failure to place a left ventricular lead via the coronary sinus. The present case describes one such failure ironically leading to resynchronization. The patient's QRS narrowing subsequent to postimplant atrial pacing alone suggests that bradycardia-dependent phase 4 block was the indirect but exclusive cause of the patient's intraventricular conduction delay. Thus, phase 4 block should be considered when atrial pacing at a faster rate resolves a wide QRS interval.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia , Anciano , Angiografía Coronaria , Ecocardiografía , Electrocardiografía , Prueba de Esfuerzo , Humanos , Masculino , Insuficiencia del Tratamiento
13.
Proc (Bayl Univ Med Cent) ; 31(3): 378-379, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29904319
14.
Ann Pharmacother ; 52(9): 838-848, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29642718

RESUMEN

BACKGROUND: In 2012, the Food and Drug Administration issued Drug Safety Communications on several drugs associated with QT prolongation and fatal ventricular arrhythmias. Among these was citalopram, a selective serotonin reuptake inhibitor (SSRI) approved for depression and commonly used for posttraumatic stress disorder (PTSD). Evaluation of the risk for QT prolongation among other psychotropic drugs for individuals with PTSD remains limited. OBJECTIVE: Explore psychotropic drugs associated with QT prolongation among veterans with PTSD. METHODS: Patients in the Veterans Health Administration in 2006-2009 with PTSD and QT prolongation (176 cases) were matched 1:4 on age, gender, visit date and setting, and physical comorbidity. Classification trees assessed QT prolongation risk among prescribed medications (n=880). RESULTS: Receipt of any drug with known risk of QT prolongation varied by group (23% QT cases vs 15% control, p<0.01). Psychotropic medications conferring significant risks included ziprasidone (3% vs 1%, p=0.02) and buspirone (6% vs 2%, p=0.01). Increased risk was not observed for the SSRIs, citalopram and fluoxetine. Classification trees found that sotalol and amitriptyline carried greater risk among cardiac patients and methadone, especially if prescribed with quetiapine, among noncardiac patients. Per adjusted survival model, patients with QT prolongation were at increased risk for death (hazard ratio=1.60; 95% CI=1.04-2.44). CONCLUSIONS: Decision models are particularly advantageous when exploring nonlinear relationships or nonadditive interactions. These findings may potentially affect clinical decision-making concerning treatment for PTSD. For patients at higher risk of QT prolongation, antidepressants other than amitriptyline should be considered. Medications for comorbid conditions should also be closely monitored for heightened QT prolongation risk.


Asunto(s)
Arritmias Cardíacas/inducido químicamente , Psicotrópicos/efectos adversos , Trastornos por Estrés Postraumático/tratamiento farmacológico , Adulto , Anciano , Anciano de 80 o más Años , Amitriptilina/efectos adversos , Buspirona/efectos adversos , Femenino , Humanos , Masculino , Metadona/efectos adversos , Persona de Mediana Edad , Piperazinas/efectos adversos , Fumarato de Quetiapina/efectos adversos , Sotalol/efectos adversos , Tiazoles/efectos adversos , Veteranos , Adulto Joven
15.
Proc (Bayl Univ Med Cent) ; 31(4): 499-501, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30948992

RESUMEN

A 13-year-old boy presenting with palpitations was diagnosed with Wolf-Parkinson-White syndrome. We elected to bring him to the electrophysiology lab for evaluation of the accessory pathway and potential ablation. Structural assessment of the coronary sinus with electro-anatomical mapping and retrograde venography led to the discovery of a great cardiac vein having a separate insertion from the coronary sinus into the high right atrium. The accessory pathway was localized to the left lateral portion of the mitral annulus and treated successfully with radiofrequency ablation. Such venous anatomical variant has been seldom reported, and its association with an accessory pathway is described here for the first time. Its recognition can have important implications when performing procedures that require access into the coronary venous system.

16.
J Cardiovasc Electrophysiol ; 28(8): 953-955, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28485513

RESUMEN

BALLOON BREACH DURING CRYOABLATION: To date, this is the first published report of a double-wall breach while using the cryoballoon ablation catheter during the treatment of a patient with atrial fibrillation; however, there have been previous balloon breaches in both the second and third-generation cryoballoon ablation catheter usage. In this report, we describe the case of a double-wall balloon breach and the intraoperative care that was necessary to stabilize the patient. Additionally, we review other known cases of double-wall balloon breaches, and we examine the safety systems of the cryoballoon catheter that mitigate some of the potential patient complications.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Complicaciones Intraoperatorias/diagnóstico por imagen , Oclusión con Balón/efectos adversos , Humanos , Complicaciones Intraoperatorias/etiología , Masculino , Persona de Mediana Edad
18.
Med Clin North Am ; 99(4): 877-96, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26042888

RESUMEN

Current available mobile health technologies make possible earlier diagnosis and long-term monitoring of patients with cardiovascular diseases. Remote monitoring of patients with implantable devices and chronic diseases has resulted in better outcomes reducing health care costs and hospital admissions. New care models, which shift point of care to the outpatient setting and the patient's home, necessitate innovations in technology.


Asunto(s)
Enfermedades Cardiovasculares/terapia , Monitoreo Ambulatorio/métodos , Telemedicina/métodos , Tecnología Inalámbrica , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Humanos , Marcapaso Artificial
19.
J Interv Card Electrophysiol ; 43(3): 227-36, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25935227

RESUMEN

BACKGROUND: The role of intracardiac echocardiography (ICE) to detect thrombus within left atrium (LA) before atrial fibrillation (AF) ablation despite a recent transesophageal echocardiogram (TEE) is not well defined. We examined the prevalence of LA/left atrial appendage (LAA) thrombus using ICE immediately prior to AF ablation in patients in whom anticoagulation was not withheld. METHODS: We analyzed 122 consecutive patients (62.6 ± 10.8 years, 90 males, CHA(2)DS(2) -VASc score 2.4 ± 1.5, persistent AF 29.5 %) who underwent an ICE-guided AF ablation 1 day after a negative (n = 120) or inconclusive (n = 2) TEE for LA thrombus. LA was imaged with ICE from the right atrium, coronary sinus, and right ventricular inflow tract (RVIT). ICE and TEE images were compared for LAA area, thrombus, and spontaneous echo contrast (SEC). RESULTS: LAA was adequately visualized in 99 and 100 % of patients with TEE and ICE, respectively. RVIT was the best ICE view for LAA visualization. The LAA 2-D-area measured by TEE was 4.9 ± 0.5 vs. 5 ± 0.5 cm(2) by ICE (P = NS). ICE identified a thrombus in seven patients with a previous negative TEE, leading to cancellation of ablation. It ruled out a thrombus in two patients with an inconclusive TEE. Thrombi were found in the LAA (n = 4), atrial septum (n = 2), and left superior pulmonary vein (n = 1). SEC during TEE was more frequent in patients with thrombus on ICE than those without (85.7 vs. 17.4 %; p = 0.03; positive predictive value 23.1 %, negative predictive value 98.9 %). CONCLUSIONS: The results of our staged imaging approach suggest that ICE has a complimentary value in re-screening the LA/LAA for thrombus after a recent negative or equivocal TEE. The presence of SEC during TEE increases the probability of finding a thrombus with ICE, which could potentially be dislodged during catheter manipulation.


Asunto(s)
Fibrilación Atrial/epidemiología , Ecocardiografía/estadística & datos numéricos , Trombosis del Seno Lateral/diagnóstico por imagen , Trombosis del Seno Lateral/epidemiología , Cirugía Asistida por Computador/estadística & datos numéricos , Fibrilación Atrial/cirugía , Ablación por Catéter/estadística & datos numéricos , Comorbilidad , Ecocardiografía/métodos , Femenino , Atrios Cardíacos/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Pennsylvania/epidemiología , Prevalencia , Factores de Riesgo , Cirugía Asistida por Computador/métodos
20.
J Interv Card Electrophysiol ; 42(2): 129-34, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25601562

RESUMEN

BACKGROUND: The anatomical reconstruction of the left atrium (LA) and pulmonary veins with fast anatomical mapping (FAM) and intracardiac echocardiography (ICE) using the Carto 3 system (Biosense Webster, Inc) provides real-time guidance to catheter manipulation during ablation of atrial fibrillation (AF). The present study compared real-time LA volume reconstruction using FAM and ICE. In addition, the contribution of respiratory gating was assessed. METHODS: LA reconstruction was created using FAM and ICE in 60 consecutive patients (mean age 63 ± 9 years; 38 males) undergoing AF ablation. In the first 30 patients, FAM and ICE were performed without respiratory gating. In the last 30 patients, FAM and ICE were performed with respiratory gating. RESULTS: LA volumes determined by FAM were larger than those obtained with ICE in the absence of respiratory gating (n = 30; 129.5 ± 44 vs 110 ± 39.7 cm(3); p = 0.001). However, respiratory gating reduced LA volume determined with FAM by 17.7 ± 6.6% resulting in similar LA volumes to those obtained using ICE [n = 30; 100 ± 29.7 (61-154) vs 101.53 ± 40.1 (56-212) cm(3), p = 0.7, NS]. CONCLUSIONS: In the absence of respiratory gating, LA volumes determined by FAM are larger than those obtained with ICE. In contrast, with the addition of respiratory gating, both FAM and ICE provide similar real-time LA volumes.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Ecocardiografía Tridimensional/métodos , Anciano , Estudios de Cohortes , Estudios de Seguimiento , Atrios Cardíacos , Humanos , Angiografía por Resonancia Magnética/métodos , Persona de Mediana Edad , Tamaño de los Órganos , Ventilación Pulmonar/fisiología , Medición de Riesgo , Muestreo , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA