Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Orthop Case Rep ; 13(9): 67-70, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37753144

RESUMEN

Introduction: Vacuum-assisted closure (VAC) dressings are used for many indications nowadays in wound management. However, there are complications with VAC dressings also. In this study, we report a 44-year-old patient with a vertical shear injury with post-operative wound complication of adherent polyurethane sponge over her wound which was removed by piecemeal dissection. Case Report: A 44-year-old patient sustained a vertical shear pelvic injury following which spinopelvic fusion surgery was performed. The patient developed wound dehiscence along with discharge on POD 4. Following this, VAC dressing was applied to the wound. After 3 days, the polyurethane sponge became adherent to the wound. The sponge was removed gradually through daily debridement in a piecemeal manner. The wound was found to be healthy and a keystone flap was raised to cover the wound. Conclusion: Although such complication of an adherent sponge has not been reported to date, one must keep in mind this complication while making improvisations to commercially available VAC dressings.

2.
BMJ Case Rep ; 16(3)2023 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-36944442

RESUMEN

A woman in her 40s presented with a swelling over her left distal forearm and hand since 7 months, progressively increasing in size. She had history of difficulty in moving her wrist and fingers with no associated pain. She had no immune or chronic conditions except for hypothyroidism for which she was on regular medication. On examination, there was an 8×7 cm swelling on the radial side of the volar surface of her left distal forearm extending till the thenar eminence. MRI of the left upper limb was suggestive of a soft tissue swelling arising from the flexor tendon.The patient was planned for surgical excision of the swelling. Intraoperatively, there was a mass arising from the flexor tendons of flexor digitorum superficialis, flexor digitorum profundus (FDP) and flexor pollicis longus (FPL), extending distally up to the mid palm region. On incising the flexor tendon sheath, it was observed that multiple yellowish rice like granules extended across the tendons. The lesion was excised completely and sent for histopathology examination. The lax FDP of little and ring fingers were plicated following proper tension adjustment and defect in FPL was primarily repaired. Postoperatively, the patient recovered well with no local wound complications. The biopsy report was suggestive of tuberculosis. The patient completed a course of antituberculosis treatment in 6 months.


Asunto(s)
Tenosinovitis , Tuberculosis Osteoarticular , Femenino , Humanos , Muñeca/diagnóstico por imagen , Muñeca/cirugía , Muñeca/patología , Tenosinovitis/diagnóstico por imagen , Tenosinovitis/cirugía , Tendones/diagnóstico por imagen , Tendones/cirugía , Tendones/patología , Articulación de la Muñeca/diagnóstico por imagen , Articulación de la Muñeca/cirugía , Articulación de la Muñeca/patología , Tuberculosis Osteoarticular/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...