Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Thorac Cardiovasc Surg ; 157(3): 907-916, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33198014

RESUMEN

BACKGROUND: Mitral valve replacement in the setting of severe mitral annular calcification remains a surgical challenge. Transcatheter mitral valve replacement (TMVR) using an aortic balloon-expandable transcatheter heart valve is emerging as a potential treatment option for high surgical risk patients. Transseptal, transapical, or transatrial access is not always feasible, so an understanding of alternative implantation techniques is important. OBJECTIVES: The authors sought to present a step-by-step description of a contemporary transatrial TMVR technique using balloon-expandable aortic transcatheter heart valves. This procedure has evolved over time to address valve migration, left ventricular outflow tract obstruction, and paravalvular leak. The authors present a refined technique that has been associated with the most reproducible outcomes. METHODS: A step-by-step description of the TMVR technique and outcomes of 8 patients treated using this technique are described. Baseline patient clinical and echocardiographic characteristics and 30-day post-TMVR outcomes are presented. RESULTS: Eight patients underwent transatrial TMVR at a single institution. Five had previous cardiac surgery. Mean STS score was 8%. Technical success by MVARC (Mitral Valve Academic Research Consortium) criteria was 100%. There was zero in-hospital and 30-day mortality. Procedural success by MVARC criteria at 30 days was 100%. Paravalvular leak immediately post-implant was none or trace in 6 and mild in 1. CONCLUSIONS: The technique described is reproducible and was associated with favorable outcomes in this early experience. It represents a useful technique for the treatment of mitral valve disease in the setting of severe annular calcification. A structured and defined implantation technique is critical to investigators as this field evolves.

2.
J Am Coll Cardiol ; 72(13): 1437-1448, 2018 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-30236304

RESUMEN

BACKGROUND: Mitral valve replacement in the setting of severe mitral annular calcification remains a surgical challenge. Transcatheter mitral valve replacement (TMVR) using an aortic balloon-expandable transcatheter heart valve is emerging as a potential treatment option for high surgical risk patients. Transseptal, transapical, or transatrial access is not always feasible, so an understanding of alternative implantation techniques is important. OBJECTIVES: The authors sought to present a step-by-step description of a contemporary transatrial TMVR technique using balloon-expandable aortic transcatheter heart valves. This procedure has evolved over time to address valve migration, left ventricular outflow tract obstruction, and paravalvular leak. The authors present a refined technique that has been associated with the most reproducible outcomes. METHODS: A step-by-step description of the TMVR technique and outcomes of 8 patients treated using this technique are described. Baseline patient clinical and echocardiographic characteristics and 30-day post-TMVR outcomes are presented. RESULTS: Eight patients underwent transatrial TMVR at a single institution. Five had previous cardiac surgery. Mean STS score was 8%. Technical success by MVARC (Mitral Valve Academic Research Consortium) criteria was 100%. There was zero in-hospital and 30-day mortality. Procedural success by MVARC criteria at 30 days was 100%. Paravalvular leak immediately post-implant was none or trace in 6 and mild in 1. CONCLUSIONS: The technique described is reproducible and was associated with favorable outcomes in this early experience. It represents a useful technique for the treatment of mitral valve disease in the setting of severe annular calcification. A structured and defined implantation technique is critical to investigators as this field evolves.


Asunto(s)
Calcinosis/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Anciano , Anciano de 80 o más Años , Valvuloplastia con Balón , Femenino , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Cuidados Posoperatorios , Cuidados Preoperatorios , Tomografía Computarizada por Rayos X
3.
J Am Soc Echocardiogr ; 29(3): 267-75, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26711364

RESUMEN

BACKGROUND: Percutaneous valve-in-valve therapy has become an important treatment option for failing bioprosthetic heart valves. Accurate assessment of valve internal diameter (ID) is essential for effective and safe treatment. These data may not be available in an individual patient, or the manufacturer-supplied dimensions may be incorrect because they do not allow for the space occupied by valve leaflet material. METHODS: In total, 2,332 two-dimensional and three-dimensional transesophageal echocardiographic in vitro measurements were performed using both Philips iE33 and GE Vivid E9 systems with a range of system settings on 53 bioprosthetic valves in all available sizes. Two-dimensional echocardiographic ID measurements were made in two orthogonal planes at the level of the sewing ring, and similar three-dimensional measurements were generated from multiplane reconstructions. They were compared with both manufacturer-supplied valve ID (MID) and the true ID (TID) measured with Hegar dilators. RESULTS: Both the iE33 and the Vivid 9 provided comparable valve ID measurements. TID was statistically significantly smaller than MID (P < .001). All echocardiographic measurements were closer to TID than to MID. Two-dimensional measurements were closest to TID because of higher spatial resolution. CONCLUSIONS: Transesophageal echocardiographic valve ID measurements compare well with TID, which is overestimated by MID. These findings have potentially important implications for valve-in-valve procedures because an inaccurate measurement of TID might lead to the wrong choice of implanted valve.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Bioprótesis , Ecocardiografía Transesofágica/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Ecocardiografía Transesofágica/instrumentación , Análisis de Falla de Equipo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Fantasmas de Imagen , Diseño de Prótesis , Ajuste de Prótesis/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento
5.
JACC Cardiovasc Interv ; 6(11): 1186-94, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24139931

RESUMEN

OBJECTIVES: This study sought to provide a guide to the fluoroscopic appearances of various valve-in-valve (VIV) combinations by deploying a transcatheter heart valve (THV) within a degenerated surgical heart valve (SHV) in an ideal position. BACKGROUND: VIV procedures are being increasingly performed with substantial experience acquired in treating degenerated SHV in the aortic position with Sapien/Sapien XT (Edwards Lifesciences Ltd., Irvine, California) and CoreValve/Evolute (Medtronic Inc., Minneapolis, Minnesota) valves. Although less invasive than conventional surgery, securing the THV in an optimal position within the SHV determines the success of this novel treatment. METHODS: For VIV implantation, we selected appropriate Sapien XT and CoreValve/Evolute sizes depending on the internal diameter of the SHV. Implantation was performed in vitro. In case of the Sapien XT valve, it was deployed 4 to 5 mm below the sewing ring of the SHV, whereas the CoreValve/Evolute was deployed 5 mm below the level of the sewing ring. Photographs and fluoroscopic images of the various VIV combinations were obtained in side profile to study the ideal position and end-on profile to study the circularity of the THV. RESULTS: Fluoroscopic images obtained in side profile highlighted the differences in various VIV combinations, as all SHV are unique in their fluoroscopic appearances. Also, all THV implants in various VIV combinations achieved a nearly circular shape. CONCLUSIONS: To achieve an optimal result when considering VIV, it is important to be familiar with the structure and fluoroscopic appearances of the failed SHV, the THV used, and their combination.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica/cirugía , Bioprótesis , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Radiografía Intervencional/métodos , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Fluoroscopía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Diseño de Prótesis
6.
J Heart Valve Dis ; 22(1): 85-8, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23610994

RESUMEN

Transcatheter aortic valve implantation (TAVI) is an emerging surgical approach in patients with severe aortic stenosis unsuitable for conventional aortic valve replacement (AVR). TAVI has been performed through both transfemoral and transapical approaches, each with a specific suitability criterion. A transaortic (TAo-TAVI) approach has been recently established at the authors' institution for high-risk patients who are unsuited to the above techniques. Herein, the case is described of a successful aortic valve implantation using TAo-TAVI in a patient with porcelain ascending aorta that was identified as an incidental finding during conventional AVR. The patient recovered well and was discharged home without any complications.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estenosis de la Válvula Aórtica/complicaciones , Procedimientos Endovasculares , Humanos , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/complicaciones , Esternotomía , Calcificación Vascular/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA