Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Laryngoscope ; 134(3): 1299-1307, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37668315

RESUMEN

OBJECTIVE: With the shift toward utilization of sentinel lymph node biopsy (SLNB) in oral cavity cancer, improved techniques for intraoperative sentinel node identification are needed. This study investigates the feasibility of fluorescently labeled tilmanoscept in SLNB in an oral cancer rabbit model. METHODS: An animal study was designed using 21 healthy male New Zealand rabbits. Gallium-68-labeled tilmanocept labeled with IRDye800CW was injected submucosally into the buccal mucosa (n = 6) or lateral tongue (n = 7) followed by PET imaging. One hour after injection, SLNB was performed using fluorescence imaging followed by a bilateral neck dissection and sampling of non-nodal surrounding tissue. All tissues were measured for radioactivity and fluorescence. In addition, eight rabbits were injected with delayed SLNB performed 48 h after injection. RESULTS: Buccal injections all had ipsilateral SLN drainage and tongue injections exhibited 18.2% contralateral drainage. An average of 1.9 ± 1.0 SLN (range 1-5) were identified. In addition, an average of 16.9 ± 3.3 non-sentinel lymph nodes were removed per animal. SLNs had an average of 0.69 ± 0.60 percent-of-injected dose (%ID) compared with non-sentinel nodes with 0.012 ± 0.025 %ID and surrounding tissue with 0.0067 ± 0.015 %ID. There was 98.0% agreement between sentinel lymph nodes identified using fluorescence compared to radioactivity with Cohen's kappa coefficient of 0.879. In 48-h delayed SLNB, results were consistent with 97.8% agreement with radioactivity and Cohen's Kappa coefficient of 0.884. Fluorescence identified additional lymph nodes that were not identified by radioactivity, and with one false negative. CONCLUSION: Fluorescent-labeled Tc-99 m-tilmanocept represents a highly accurate adjunct to enhance SLNB for oral cavity cancer. LEVEL OF EVIDENCE: N/A Laryngoscope, 134:1299-1307, 2024.


Asunto(s)
Neoplasias de la Boca , Ganglio Linfático Centinela , Masculino , Animales , Conejos , Biopsia del Ganglio Linfático Centinela/métodos , Ganglios Linfáticos/patología , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/cirugía , Ganglio Linfático Centinela/patología , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/cirugía , Neoplasias de la Boca/patología
2.
Psychiatry Res Neuroimaging ; 321: 111445, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35101828

RESUMEN

Despite increased survivability for people living with HIV (PLWH), HIV-related cognitive deficits persist. Determining biological mechanism(s) underlying abnormalities is critical to minimize the long-term impact of HIV. Positron emission tomography (PET) studies reveal that PLWH exhibit elevated neuroinflammation, potentially contributing to these problems. PLWH are hypersensitive to environmental insults that drive elevated inflammatory profiles. Gp120 is an envelope glycoprotein exposed on the surface of the HIV envelope which enables HIV entry into a cell contributing to HIV-related neurotoxicity. In vivo evidence for mice overexpressing gp120 (transgenic) mice exhibiting neuroinflammation remains unclear. Here, we conducted microPET imaging in gp120 transgenic and wildtype mice, using the radiotracer [(18)F]FEPPA (binds to the translocator protein expressed by activated microglial serving as a neuroinflammatory marker). Imaging was performed at baseline and 24 h after lipopolysaccharide (LPS; 5 mg/kg) treatment (endotoxin that triggers an immune response). Gp120 transgenic mice exhibited elevated [(18F)]FEPPA in response to LPS vs. wildtype mice throughout the brain including dorsal and ventral striata, hypothalamus, and hippocampus. Gp120 transgenic mice are hypersensitive to environmental inflammatory insults, consistent with PLWH, measurable in vivo. It remains to-be-determined whether this heightened sensitivity is connected to the behavioral abnormalities of these mice or sensitive to any treatments.


Asunto(s)
Infecciones por VIH , Receptores de GABA , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Infecciones por VIH/complicaciones , Infecciones por VIH/diagnóstico por imagen , Infecciones por VIH/metabolismo , Humanos , Inflamación/diagnóstico por imagen , Inflamación/metabolismo , Ratones , Tomografía de Emisión de Positrones/métodos , Receptores de GABA/metabolismo
3.
Nucl Med Biol ; 92: 107-114, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32169304

RESUMEN

INTRODUCTION: Blood-brain barrier (BBB) disruption and subsequent neuro-inflammation occur following traumatic brain injury (TBI), resulting in a spectrum of human nervous system disorders. [99mTc]Tc-tilmanocept is a receptor-binding radiopharmaceutical FDA-approved for sentinel lymph node mapping. We hypothesize that after an intravenous (i.v.) injection, [99mTc]Tc-tilmanocept, will traverse a disrupted BBB and bind to CD206-bearing microglial cells. METHODS: Age-matched mice were divided into three groups: 5-days post TBI (n = 4), and 5-days post sham (n = 4), and naïve controls (n = 4). IRDye800CW-labeled [99mTc]Tc-tilmanocept (0.15 nmol per gram body weight) and FITC-labeled bovine serum albumin (FITC-BSA) were injected (i.v.) into each mouse. Mice were imaged with a high-resolution gamma camera for 45 min. Immediately after imaging, the brains were perfused with fixative, excised, imaged with a fluorescence scanner, assayed for radioactivity, and prepared for histology. RESULTS: In vivo nuclear imaging, ex vivo fluorescence imaging, ex vivo gamma well counting, and histo-microscopy demonstrated enhanced tilmanocept uptake in the TBI region. The normalized [99mTc]Tc-tilmanocept uptake value from nuclear imaging and the maximum pixel intensity from fluorescence imaging of the TBI group (1.12 ±â€¯0.12 and 2288 ±â€¯278 a.u., respectively) were significantly (P < 0.04) higher than the sham group (0.64 ±â€¯0.28 and 1708 ±â€¯101 a.u., respectively) and the naive group (0.76 ±â€¯0.24 and 1643 ±â€¯391 a.u., respectively). The mean [99mTc]Tc-tilmanocept scaled uptake in the TBI brains (0.058 ±â€¯0.013%/g) was significantly (P < 0.010) higher than the scaled brain uptake of the sham group (0.031 ±â€¯0.011%/g) and higher (P = 0.04) than the uptake of the naïve group (0.020 ±â€¯0.002%/g). Fluorescence microscopy demonstrated increased uptake of the IRDye800CW-tilmanocept and FITC-BSA in the TBI brain regions. CONCLUSION: [99mTc]Tc-tilmanocept traverses disrupted blood-brain barrier and localizes within the injured region. ADVANCES IN KNOWLEDGE AND IMPLICATIONS FOR PATIENT CARE: [99mTc]Tc-tilmanocept could serve as an imaging biomarker for TBI-associated neuroinflammation and any disease process that involves a disruption of the blood-brain barrier.


Asunto(s)
Lesiones Traumáticas del Encéfalo/diagnóstico por imagen , Lesiones Traumáticas del Encéfalo/metabolismo , Dextranos/metabolismo , Mananos/metabolismo , Radiofármacos/metabolismo , Pentetato de Tecnecio Tc 99m/análogos & derivados , Animales , Modelos Animales de Enfermedad , Masculino , Ratones , Pentetato de Tecnecio Tc 99m/metabolismo
4.
J Nucl Med ; 60(9): 1325-1332, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30796169

RESUMEN

An unmet need for the clinical management of chronic kidney disease is a predictive tool of kidney function during the first decade of the disease, when there is silent loss of glomerular function. The objective of this study was to demonstrate receptor-mediated binding of tilmanocept to CD206 within the kidney and provide evidence of kinetic sensitivity of this binding to renal function. Methods: Rats were positioned in a PET scanner with the liver and kidneys within the field of view. After an intravenous injection of 68Ga-IRDye800-tilmanocept, using 1 of 2 scaled molar doses (0.02 nmol/g, n = 5; or 0.10 nmol/g, n = 5), or coinjection (n = 3) of 68Ga-IRDye800-tilmanocept (0.10 nmol/g) and unlabeled tilmanocept (5.0 nmol/g), or a negative control, 68Ga-IRDye800-DTPA-galactosyl-dextran (0.02 nmol/g, n = 5), each animal was imaged for 20 min followed by a whole-body scan. Frozen kidney sections were stained for podocytes and CD206 using immunofluorescence. Molecular imaging of diabetic db/db mice (4.9 wk, n = 6; 7.3 wk, n = 4; 13.3 wk, n = 6) and nondiabetic db/m mice (n = 6) was performed with fluorescence-labeled 99mTc-tilmanocept (18.5 MBq, 2.6 nmol). Thirty minutes after injection, blood, liver, kidneys, and urine were assayed for radioactivity. Renal time-activity curves were generated. Results: Rat PET whole-body images and time-activity curves of 68Ga-IRDye800-tilmanocept demonstrated receptor-mediated renal accumulation with evidence of glomerular uptake. Activity within the renal cortex persisted during the 40-min study. Histologic examination demonstrated colocalization of CD206 and IRDye800-tilmanocept within the glomerulus. The glomerular accumulation of the coinjection and the negative control studies were significantly less than the CD206-targeted agent. The db/db mice displayed a multiphasic renal time-activity curve with high urinary bladder accumulation; the nondiabetic mice exhibited renal uptake curves dominated by a single phase with low bladder accumulation. Conclusion: This study demonstrated receptor-mediated binding to the glomerular mesangial cells and kinetic sensitivity of tilmanocept to chronic renal disease. Given the role of mesangial cells during the progression of diabetic nephropathy, PET or SPECT renal imaging with radiolabeled tilmanocept may provide a noninvasive quantitative assessment of glomerular function.


Asunto(s)
Dextranos/farmacocinética , Glomérulos Renales/efectos de los fármacos , Glomérulos Renales/diagnóstico por imagen , Células Mesangiales/metabolismo , Tomografía de Emisión de Positrones , Pentetato de Tecnecio Tc 99m/análogos & derivados , Tomografía Computarizada de Emisión de Fotón Único , Animales , Inmunohistoquímica , Inyecciones Intravenosas , Cinética , Lectinas Tipo C/metabolismo , Hígado/metabolismo , Ganglios Linfáticos/patología , Masculino , Receptor de Manosa , Lectinas de Unión a Manosa/metabolismo , Ratones , Microscopía Fluorescente , Imagen Molecular , Radiofármacos/farmacocinética , Ratas , Receptores de Superficie Celular/metabolismo , Biopsia del Ganglio Linfático Centinela , Pentetato de Tecnecio Tc 99m/farmacocinética , Distribución Tisular , Imagen de Cuerpo Entero
5.
Chem Mater ; 31(1): 251-259, 2019 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-33859455

RESUMEN

In this paper, we show that gadolinium-loaded synthetic melanin nanoparticles (Gd(III)-SMNPs) exhibit up to a 40-fold enhanced photoacoustic signal intensity relative to synthetic melanin alone and higher than other metal-chelated SMNPs. This property makes these materials useful as dual labeling agents because Gd(III)-SMNPs also behave as magnetic resonance imaging (MRI) contrast agents. As a proof-of-concept, we used these nanoparticles to label human mesenchymal stem cells. Cellular uptake was confirmed with bright-field optical and transmission electron microscopy. The Gd(III)-SMNP-labeled stem cells continued to express the stem cell surface markers CD73, CD90, and CD105 and proliferate. The labeled stem cells were subsequently injected intramyocardially in mice, and the tissue was observed by photoacoustic and MR imaging. We found that the photoacoustic signal increased as the cell number increased (R 2 = 0.96), indicating that such an approach could be employed to discriminate between stem cell populations with a limit of detection of 2.3 × 104 cells in in vitro tests. This multimodal photoacoustic/MRI approach combines the excellent temporal resolution of photoacoustics with the anatomic resolution of MRI.

6.
PLoS One ; 13(7): e0197842, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29965996

RESUMEN

Molecular imaging with a fluorescent version of Tilmanocept may permit an accurate and facile detection of sentinel nodes of endometrial cancer. Tilmanocept accumulates in sentinel lymph nodes (SLN) by binding to a cell surface receptor unique to macrophages and dendritic cells. Four female Yorkshire pigs underwent cervical stromal injection of IRDye800-Tilmanocept, a molecular imaging agent tagged with near-infrared fluorescent dye and radiolabeled with gallium-68 and technetium-99m. PET/CT scans 1.5 hours post-injection provided pre-operative SLN mapping. Robotic-assisted lymphadenectomy was performed two days after injection, using the FireFly imaging system to identify nodes demonstrating fluorescent signal. After removal of fluorescent nodes, pelvic and periaortic node dissections were performed. Nodes were assayed for technetium-99m activity, and SLNs were established using the "10%-rule", requiring that the radioactivity of additional SLNs be greater than 10% of the "hottest" SLN. Thirty-four nodal samples were assayed ex vivo for radioactivity. All the SLNs satisfying the "10%-rule" were detected using the FireFly system. Five fluorescent nodes were detected, corresponding with preoperative PET/CT scan. Three pigs had one SLN and one pig had two SLNs, with 100% concordance between fluorescence and radioactivity. Fluorescent-labeled Tilmanocept permits real-time intraoperative detection of SLNs during robotic-assisted lymphadenectomy for endometrial cancer in a porcine model. When radiolabeled with gallium-68, Tilmanocept allows for preoperative localization of SLNs using PET/CT, and shows specificity to SLNs with persistent fluorescent signal, detectable using the FireFly system, for two days post-injection. In conclusion, these findings suggest that a phase I trial in human subjects is warranted, and that a long-term goal of an intra-operative administration of non-radioactive fluorescent-labeled Tilmanocept is possible.


Asunto(s)
Neoplasias Endometriales/cirugía , Imagen Molecular/métodos , Procedimientos Quirúrgicos Robotizados , Neoplasias Uterinas/cirugía , Animales , Modelos Animales de Enfermedad , Neoplasias Endometriales/diagnóstico por imagen , Neoplasias Endometriales/patología , Femenino , Colorantes Fluorescentes/uso terapéutico , Humanos , Escisión del Ganglio Linfático , Ganglios Linfáticos/patología , Ganglios Linfáticos/cirugía , Metástasis Linfática , Imagen Óptica/métodos , Pelvis/diagnóstico por imagen , Pelvis/patología , Pelvis/cirugía , Tomografía Computarizada por Tomografía de Emisión de Positrones , Ganglio Linfático Centinela/diagnóstico por imagen , Biopsia del Ganglio Linfático Centinela/métodos , Porcinos , Pentetato de Tecnecio Tc 99m/administración & dosificación , Neoplasias Uterinas/diagnóstico por imagen , Neoplasias Uterinas/patología
7.
IEEE Trans Med Imaging ; 37(1): 222-229, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28829305

RESUMEN

An on-demand long-lived ultrasound contrast agent that can be activated with single pulse stimulated imaging (SPSI) has been developed using hard shell liquid perfluoropentane filled silica 500-nm nanoparticles for tumor ultrasound imaging. SPSI was tested on LnCAP prostate tumor models in mice; tumor localization was observed after intravenous (IV) injection of the contrast agent. Consistent with enhanced permeability and retention, the silica nanoparticles displayed an extended imaging lifetime of 3.3±1 days (mean±standard deviation). With added tumor specific folate functionalization, the useful lifetime was extended to 12 ± 2 days; in contrast to ligand-based tumor targeting, the effect of the ligands in this application is enhanced nanoparticle retention by the tumor. This paper demonstrates for the first time that IV injected functionalized silica contrast agents can be imaged with an in vivo lifetime ~500 times longer than current microbubble-based contrast agents. Such functionalized long-lived contrast agents may lead to new applications in tumor monitoring and therapy.


Asunto(s)
Medios de Contraste/química , Nanopartículas/química , Ultrasonografía/métodos , Animales , Medios de Contraste/farmacocinética , Masculino , Ratones , Microburbujas , Neoplasias Experimentales/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico por imagen , Distribución Tisular
8.
J Nucl Med ; 58(4): 547-553, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28153955

RESUMEN

The primary objective was to test the ability of a laparoscopic camera system to detect the fluorescent signal emanating from sentinel lymph nodes (SLNs) approximately 2 d after injection and imaging of a positron-emitting molecular imaging agent into the submucosa of the porcine urinary bladder. Methods: Three female pigs underwent a submucosal injection of the bladder with fluorescent-tagged tilmanocept, radiolabeled with both 68Ga and 99mTc. One hour after injection, a pelvic PET/CT scan was acquired for preoperative SLN mapping. Approximately 36 h later, robotic SLN mapping was performed using a fluorescence-capable camera system. After identification of the fluorescent lymph nodes, a pelvic lymph node dissection was completed with robotic assistance. All excised nodal packets (n = 36) were assayed for 99mTc activity, which established a lymph node as an SLN. 99mTc activity was also used to calculate the amount of dye within each lymph node. Results: All of the SLNs defined by the ex vivo γ-well assay of 99mTc activity were detected by fluorescence mode imaging. The time between injection and robotic SLN mapping ranged from 32 to 38 h. A total of 5 fluorescent lymph nodes were detected; 2 pigs had 2 fluorescent lymph nodes and 1 pig exhibited a single lymph node. Four of the 5 SLNs exhibited increased SUVs of 12.4-139.0 obtained from PET/CT. The dye content of the injection sites ranged from 371 to 1,441 pmol, which represented 16.5%-64.1% of the injected dose; the amount of dye within the SLNs ranged from 8.5 to 88 pmol, which was equivalent to 0.38%-3.91% of the administered dose. Conclusion: Fluorescent-labeled 68Ga-tilmanocept allows for PET imaging and real-time intraoperative detection of SLNs during robotic surgery.


Asunto(s)
Imagen Óptica , Ganglio Linfático Centinela/diagnóstico por imagen , Vejiga Urinaria/diagnóstico por imagen , Animales , Estudios de Factibilidad , Femenino , Tomografía Computarizada por Tomografía de Emisión de Positrones , Porcinos
9.
ACS Appl Mater Interfaces ; 9(2): 1719-1727, 2017 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-28001041

RESUMEN

Ultrasound imaging is a safe, low-cost, and in situ method for detecting in vivo medical devices. A poly(methyl-2-cyanoacrylate) film containing 2 µm boron-doped, calcined, porous silica microshells was developed as an ultrasound imaging marker for multiple medical devices. A macrophase separation drove the gas-filled porous silica microshells to the top surface of the polymer film by controlled curing of the cyanoacrylate glue and the amount of microshell loading. A thin film of polymer blocked the wall pores of the microshells to seal air in their hollow core, which served as an ultrasound contrast agent. The ultrasound activity disappeared when curing conditions were modified to prevent the macrophase segregation. Phase segregated films were attached to multiple surgical tools and needles and gave strong color Doppler signals in vitro and in vivo with the use of a clinical ultrasound imaging instrument. Postprocessing of the simultaneous color Doppler and B-mode images can be used for autonomous identification of implanted surgical items by correlating the two images. The thin films were also hydrophobic, thereby extending the lifetime of ultrasound signals to hours of imaging in tissues by preventing liquid penetration. This technology can be used as a coating to guide the placement of implantable medical devices or used to image and help remove retained surgical items.


Asunto(s)
Técnicas Biosensibles , Medios de Contraste , Porosidad , Dióxido de Silicio , Ultrasonografía
11.
J Surg Res ; 190(2): 391-8, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24972734

RESUMEN

BACKGROUND: High intensity-focused ultrasound (HIFU) is an alterative ablative technique currently being investigated for local treatment of breast cancer and fibroadenomas. Current HIFU therapies require concurrent magnetic resonance imaging monitoring. Biodegradable 500 nm perfluoropentane-filled iron-silica nanoshells have been synthesized as a sensitizing agent for HIFU therapies, which aid both mechanical and thermal ablation of tissues. In low duty cycle high-intensity applications, rapid tissue damage occurs from mechanical rather than thermal effects, which can be monitored closely by ultrasound obviating the need for concurrent magnetic resonance imaging. MATERIALS AND METHODS: Iron-silica nanoshells were synthesized by a sol-gel method on polystyrene templates and calcined to yield hollow nanoshells. The nanoshells were filled with perfluoropentane and injected directly into excised human breast tumor, and intravenously (IV) into healthy rabbits and Py8119 tumor-bearing athymic nude mice. HIFU was applied at 1.1 MHz and 3.5 MPa at a 2% duty cycle to achieve mechanical ablation. RESULTS: Ex vivo in excised rabbit livers, the time to visually observable damage with HIFU was 20 s without nanoshells and only 2 s with nanoshells administered IV before sacrifice. Nanoshells administered IV into nude mice with xenograft tumors were activated in vivo by HIFU 24 h after administration. In this xenograft model, applied HIFU resulted in a 13.6 ± 6.1 mm(3) bubble cloud with the IV injected particles and no bubble cloud without particles. CONCLUSIONS: Iron-silica nanoshells can reduce the power and time to perform HIFU ablative therapy and can be monitored by ultrasound during low duty cycle operation.


Asunto(s)
Neoplasias de la Mama/terapia , Ultrasonido Enfocado de Alta Intensidad de Ablación/instrumentación , Nanocáscaras/uso terapéutico , Animales , Femenino , Fibroadenoma/terapia , Fluorocarburos , Humanos , Hierro , Ratones , Ratones Desnudos , Conejos , Dióxido de Silicio
12.
J Am Chem Soc ; 135(50): 18710-3, 2013 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-24308273

RESUMEN

Matrix metalloproteinase enzymes, overexpressed in HT-1080 human fibrocarcinoma tumors, were used to guide the accumulation and retention of an enzyme-responsive nanoparticle in a xenograft mouse model. The nanoparticles were prepared as micelles from amphiphilic block copolymers bearing a simple hydrophobic block and a hydrophilic peptide brush. The polymers were end-labeled with Alexa Fluor 647 dyes leading to the formation of labeled micelles upon dialysis of the polymers from DMSO/DMF to aqueous buffer. This dye-labeling strategy allowed the presence of the retained material to be visualized via whole animal imaging in vivo and in ex vivo organ analysis following intratumoral injection into HT-1080 xenograft tumors. We propose that the material is retained by virtue of an enzyme-induced accumulation process whereby particles change morphology from 20 nm spherical micelles to micrometer-scale aggregates, kinetically trapping them within the tumor. This hypothesis is tested here via an unprecedented super-resolution fluorescence analysis of ex vivo tissue slices confirming a particle size increase occurs concomitantly with extended retention of responsive particles compared to unresponsive controls.


Asunto(s)
Enzimas/química , Microscopía Fluorescente/métodos , Nanopartículas , Neoplasias/metabolismo , Animales , Línea Celular , Xenoinjertos , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Ratones
13.
Biomaterials ; 34(37): 9559-65, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24034499

RESUMEN

The use of microbubbles as ultrasound contrast agents is one of the primary methods to diagnose deep venous thrombosis. However, current microbubble imaging strategies require either a clot sufficiently large to produce a circulation filling defect or a clot with sufficient vascularization to allow for targeted accumulation of contrast agents. Previously, we reported the design of a microbubble formulation that modulated its ability to generate ultrasound contrast from interaction with thrombin through incorporation of aptamer-containing DNA crosslinks in the encapsulating shell, enabling the measurement of a local chemical environment by changes in acoustic activity. However, this contrast agent lacked sufficient stability and lifetime in blood to be used as a diagnostic tool. Here we describe a PEG-stabilized, thrombin-activated microbubble (PSTA-MB) with sufficient stability to be used in vivo in circulation with no change in biomarker sensitivity. In the presence of actively clotting blood, PSTA-MBs showed a 5-fold increase in acoustic activity. Specificity for the presence of thrombin and stability under constant shear flow were demonstrated in a home-built in vitro model. Finally, PSTA-MBs were able to detect the presence of an active clot within the vena cava of a rabbit sufficiently small as to not be visible by current non-specific contrast agents. By activating in non-occlusive environments, these contrast agents will be able to detect clots not diagnosable by current contrast agents.


Asunto(s)
Aptámeros de Nucleótidos , Medios de Contraste , Microburbujas , Trombina/metabolismo , Trombosis de la Vena/diagnóstico por imagen , Animales , Aptámeros de Nucleótidos/química , Aptámeros de Nucleótidos/metabolismo , Secuencia de Bases , Coagulación Sanguínea , Medios de Contraste/química , Medios de Contraste/metabolismo , Femenino , Conejos , Ultrasonografía , Trombosis de la Vena/metabolismo
14.
ACS Nano ; 7(7): 6367-77, 2013 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-23802554

RESUMEN

Perfluoropentane gas filled iron-silica nanoshells have been developed as stationary ultrasound contrast agents for marking tumors to guide surgical resection. It is critical to establish their long-term imaging efficacy, as well as biodistribution. This work shows that 500 nm Fe-SiO2 nanoshells can be imaged by color Doppler ultrasound over the course of 10 days in Py8119 tumor bearing mice. The 500 nm nonbiodegradable SiO2 and biodegradable Fe-SiO2 nanoshells were functionalized with diethylenetriamine pentaacetic acid (DTPA) ligand and radiolabeled with (111)In(3+) for biodistribution studies in nu/nu mice. The majority of radioactivity was detected in the liver and kidneys following intravenous (IV) administration of nanoshells to healthy animals. By contrast, after nanoshells were injected intratumorally, most of the radioactivity remained at the injection site; however, some nanoshells escaped into circulation and were distributed similarly as those given intravenously. For intratumoral delivery of nanoshells and IV delivery to healthy animals, little difference was seen between the biodistribution of SiO2 and biodegradable Fe-SiO2 nanoshells. However, when nanoshells were administered IV to tumor bearing mice, a significant increase was observed in liver accumulation of SiO2 nanoshells relative to biodegradable Fe-SiO2 nanoshells. Both SiO2 and Fe-SiO2 nanoshells accumulate passively in proportion to tumor mass, during intravenous delivery of nanoshells. This is the first report of the biodistribution following intratumoral injection of any biodegradable silica particle, as well as the first report demonstrating the utility of DTPA-(111)In labeling for studying silica nanoparticle biodistributions.


Asunto(s)
Hierro/análisis , Nanopartículas/análisis , Neoplasias Experimentales/química , Ácido Pentético , Cintigrafía/métodos , Dióxido de Silicio/análisis , Ultrasonografía Doppler en Color/métodos , Animales , Línea Celular Tumoral , Radioisótopos de Indio , Inyecciones Intralesiones , Hierro/administración & dosificación , Hierro/química , Ratones , Ratones Desnudos , Nanopartículas/química , Neoplasias Experimentales/diagnóstico , Radiofármacos , Dióxido de Silicio/administración & dosificación , Dióxido de Silicio/química
15.
Adv Mater ; 25(26): 3599-604, 2013 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-23712821

RESUMEN

Enzyme-directed assembly in vivo: A targeting strategy is demonstrated, which leads to an active accumulation of nanoparticles by virtue of an assembly event specific to endogenous, enzymatic biochemical signals associated with tumor tissue. The viability of this approach is examined through a proof-of-concept study showing enzyme-directed particle targeting and accumulation in human xenograft tumors in mice following intravenous injection, and the retention of particles is demonstrated within tumors for extended periods of time.


Asunto(s)
Metaloproteinasa 2 de la Matriz/metabolismo , Metaloproteinasa 9 de la Matriz/metabolismo , Sondas Moleculares/química , Nanopartículas/química , Nanotecnología/métodos , Animales , Línea Celular Tumoral , Transferencia Resonante de Energía de Fluorescencia , Humanos , Ratones , Sondas Moleculares/metabolismo , Péptidos/química , Polímeros/química
16.
Biomaterials ; 34(21): 4926-35, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23578557

RESUMEN

Tracking neuroprogenitor cells (NPCs) that are used to target tumors, infarction or inflammation, is paramount for cell-based therapy. We employed ultrasound imaging that can detect a single microbubble because it can distinguish its unique signal from those of surrounding tissues. NPCs efficiently internalized positively charged microbubbles allowing a clinical ultrasound system to detect a single cell at 7 MHz. When injected intravenously, labeled NPCs traversed the lungs to be imaged in the left ventricle and the liver where they accumulated. Internalized microbubbles were not only less sensitive to destruction by ultrasound, but remained visible in vivo for days as compared to minutes when given free. The extended longevity provides ample time to allow cells to reach their intended target. We were also able to transfect NPCs in vitro when microbubbles were preloaded with GFP plasmid only when cells were insonated. Transfection efficiency and cell viability were both greater than 90%.


Asunto(s)
Medios de Contraste , Diagnóstico por Imagen/métodos , Microburbujas , Células-Madre Neurales/citología , Células-Madre Neurales/metabolismo , Coloración y Etiquetado , Ultrasonido/métodos , Animales , Bromodesoxiuridina/metabolismo , ADN , Técnica del Anticuerpo Fluorescente , Límite de Detección , Hígado/patología , Ratones , Ratones Desnudos , Fenómenos Ópticos , Transfección
17.
Biomaterials ; 33(20): 5124-9, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22498299

RESUMEN

Diagnosing tumors at an early stage when they are easily curable and may not require systemic chemotherapy remains a challenge to clinicians. In order to improve early cancer detection, gas filled hollow boron-doped silica particles have been developed, which can be used for ultrasound-guided breast conservation therapy. The particles are synthesized using a polystyrene template and subsequently calcinated to create hollow, rigid nanoporous microspheres. The microshells are filled with perfluoropentane vapor. Studies were performed in phantoms to optimize particle concentration, injection dose, and the ultrasound settings such as pulse frequency and mechanical index. In vitro studies have shown that these particles can be continuously imaged by US up to 48 min and their signal lifetime persisted for 5 days. These particles could potentially be given by intravenous injection and, in conjunction with contrast-enhanced ultrasound, be utilized as a screening tool to detect smaller breast cancers before they are detectible by traditional mammography.


Asunto(s)
Boro , Medios de Contraste/administración & dosificación , Nanopartículas , Neoplasias/diagnóstico por imagen , Dióxido de Silicio , Humanos , Microscopía Electrónica de Rastreo , Ultrasonografía
18.
Artículo en Inglés | MEDLINE | ID: mdl-23616934

RESUMEN

Contrast-enhanced ultrasound (CEUS) enables highly specific time-resolved imaging of vasculature by intravenous injection of ∼2 µm gas filled microbubbles. To develop a quantitative automated diagnosis of breast tumors with CEUS, breast tumors were induced in rats by administration of N-ethyl-N-nitrosourea. A bolus injection of microbubbles was administered and CEUS videos of each tumor were acquired for at least 3 min. The time-intensity curve of each pixel within a region of interest (ROI) was analyzed to measure kinetic parameters associated with the wash-in, peak enhancement, and wash-out phases of microbubble bolus injections since it was expected that the aberrant vascularity of malignant tumors will result in faster and more diverse perfusion kinetics versus those of benign lesions. Parameters were classified using linear discriminant analysis to differentiate between benign and malignant tumors and improve diagnostic accuracy. Preliminary results with a small dataset (10 tumors, 19 videos) show 100% accuracy with fivefold cross-validation testing using as few as two choice variables for training and validation. Several of the parameters which provided the best differentiation between malignant and benign tumors employed comparative analysis of all the pixels in the ROI including enhancement coverage, fractional enhancement coverage times, and the standard deviation of the envelope curve difference normalized to the mean of the peak frame. Analysis of combinations of five variables demonstrated that pixel-by-pixel analysis produced the most robust information for tumor diagnostics and achieved 5 times greater separation of benign and malignant cases than ROI-based analysis.

19.
Artículo en Inglés | MEDLINE | ID: mdl-23616935

RESUMEN

In recent years, there have been increasing developments in the field of contrast-enhanced ultrasound both in the creation of new contrast agents and in imaging modalities. These contrast agents have been employed to study tumor vasculature in order to improve cancer detection and diagnosis. An in vivo study is presented of ultrasound imaging of gas filled hollow silica microshells and nanoshells which have been delivered intraperitoneally to an IGROV-1 tumor bearing mouse. In contrast to microbubbles, this formulation of microshells provided strong ultrasound imaging signals by shell disruption and release of gas. Imaging of the microshells in an animal model was facilitated by novel image processing. Although the particle signal could be identified by eye under live imaging, high background obfuscated the particle signal in still images and near the borders of the tumor with live images. Image processing techniques were developed that employed the transient nature of the particle signal to selectively filter out the background signal. By applying image registration, high-pass, median, threshold, and motion filtering, a short video clip of the particle signal was compressed into a single image, thereby resolving the silica shells within the tumor. © 2012 American Vacuum Society.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...