Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Intervalo de año de publicación
1.
Auton Neurosci ; 227: 102675, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32474374

RESUMEN

Considering the antioxidant, neuroprotective, inflammatory and nitric oxide modulatory actions of quercetin, the aim of this study was to test the effect of quercetin administration in drinking water (40 mg/day/rat) on neuronal nitric oxide synthase (nNOS), vasoactive intestinal peptide (VIP), overall population of myenteric neurons (HuC/D) and nitric oxide (NO) levels in the jejunal samples from diabetic rats. Male Wistar rats were distributed into four groups (8 rats per group): euglycemic (E), euglycemic administered with quercetin (E+Q), diabetic (D) and diabetic administered with quercetin (D+Q). Rats were induced to diabetes with streptozotocin (35mg/kg/iv) and, after 120 days, the proximal jejunum were collected and processed for immunohistochemical (VIP, nNOS and HuC/D) and chemiluminescence (quantification of tissue NO levels) techniques. Diabetes mellitus reduced the number of nNOS-IR (immunoreactive) (p <0.05) and HuC/D-IR (p <0.001) neurons, however, promoted an increased morphometric area of nNOS-IR neurons (p <0.001) and VIP-IR varicosities (p <0.05). In D+Q group, neuroplasticity effects were observed on HuC/D-IR neurons, accompanied by a reduction of cell body area of neurons nNOS- and VIP-IR varicosities (p <0.05). The NO levels were increased in the E+Q (p <0.05) and D+Q group (p <0.001) compared to the control group. In conclusion, the results showed that quercetin supplementation increased the bioavailability of NO in the jejunum in euglycemic and mitigate the effects of diabetes on nNOS-IR neurons and VIP-IR varicosities in the myenteric plexus of diabetic rats.


Asunto(s)
Antioxidantes/farmacología , Diabetes Mellitus Experimental/tratamiento farmacológico , Yeyuno/efectos de los fármacos , Plexo Mientérico/efectos de los fármacos , Plasticidad Neuronal/efectos de los fármacos , Neuronas/efectos de los fármacos , Óxido Nítrico Sintasa de Tipo I/efectos de los fármacos , Óxido Nítrico/metabolismo , Quercetina/farmacología , Péptido Intestinal Vasoactivo/efectos de los fármacos , Animales , Antioxidantes/administración & dosificación , Diabetes Mellitus Experimental/metabolismo , Diabetes Mellitus Experimental/patología , Masculino , Plexo Mientérico/patología , Quercetina/administración & dosificación , Ratas , Ratas Wistar
2.
Cad. saúde colet., (Rio J.) ; 26(1): 70-75, jan.-mar. 2018. tab, graf
Artículo en Portugués | LILACS | ID: biblio-952498

RESUMEN

Resumo Introdução A retinopatia da prematuridade (ROP) é uma doença vasoproliferativa, que afeta a retina das crianças que nascem prematuramente; assim, este estudo propôs identificar fatores associados e predizer a retinopatia na prematuridade. Método Realizou-se um estudo transversal, com recém-nascidos prematuros, dividindo-os em dois grupos: com e sem retinopatia. As variáveis foram categorizadas por meio do teste da razão de verossimilhança e as variáveis que obtiveram p-valores menores que 0,2 foram analisadas por um modelo logístico múltiplo. A capacidade de predição do modelo foi realizada por meio da construção da curva ROC. Resultados Dos 296 recém-nascidos, 32 (10,81%) apresentaram retinopatia. No modelo logístico, as variáveis que apresentaram fator de risco foram idade gestacional ≤ 30 semanas (p-valor=0,0214), peso ao nascer ≤ 1.250 gramas (p-valor=0,0013) e escore Apgar no primeiro minuto < 7 (p-valor=0,0352). A curva ROC com sensibilidade 0,771 e especificidade 0,774 evidenciou o modelo com precisão de 0,8448 e ponto de probabilidade de 0,79. Conclusões Este modelo pode ser usado para predição de retinopatia em recém-nascidos prematuros com um fator de risco de 0,79, destacando que estes necessitam de maior atenção.


Abstract Introduction Retinopathy of prematurity (ROP) is a vasoproliferative disease that affects the retina of prematurely born children. Therefore, this study proposed to identify associated factors and to predict retinopathy in prematurity. Method A cross-sectional study including preterm newborns divided into two groups: with and without retinopathy. The variables were categorized using the likelihood ratio test, and the variables with p-values less than 0.2 were analyzed by a multiple logistic model. The model used the construction of a Receiver Operating Characteristic (ROC) curve as predicting tool. Results Of the 296 newborns, 32 (10.81%) had retinopathy. The following variables represented a risk factor according to the logistic model: gestational age ≤ 30 weeks (p-value = 0.0214), birth weight ≤ 1250 grams (p-value = 0.0013) and Apgar score at 1 minute <7 (p-value = 0.0352). The ROC curve with sensitivity of 0.771 and specificity of 0.774 was a precise model, showing accuracy of 0.8448 and a probability point of 0.79. Conclusions This model can be used to predict retinopathy in premature newborns with a risk factor of 0.79, emphasizing that the need for additional attention.

3.
Acta sci., Health sci ; 39(1): 1-7, jan.-jun. 2017.
Artículo en Inglés | LILACS | ID: biblio-837153

RESUMEN

A non-linear mixed-effects model is proposed to assess the impact of acarbose over time on postprandial glycaemia in a single rat. The model is based on two compartments, one representing the entry of glucose in the blood and the other its exit. The rat was submitted to two treatments: ingestion of starch and ingestion of starch plus acarbose. The model showed great suitability, with inferences on the behavior of glucose levels in response to treatments and supplying a richer description than just the area under the curve. The marginal curves for the two treatments are similar during the first moments; however, after reaching the peak of glucose concentration, they progressively became separate due to acarbose treatment and reached the initial levels more quickly. The proposed model, albeit with a single sample unit, showed similar results to those with larger samples; in other words, acarbose significantly attenuates glycaemia after ingestion of starch.


Neste estudo, foi proposto um modelo não linear de efeitos mistos para verificar o impacto da acarbose ao longo do tempo na glicemia pós -prandial de um único rato. Adotou-se um modelo de dois compartimentos: um representando a entrada de glicose no sangue e outro, a saída. O rato foi submetido a dois tratamentos: ingestão de amido e de amido com adição de acarbose. O modelo proposto apresentou um ótimo ajuste, permitindo fazer inferências do comportamento da glicose para os tratamentos e fornecendo uma descrição muito mais rica do que simplesmente a área sob a curva. As curvas marginais para os dois tratamentos foram semelhantes nos primeiros tempos observados, porém, após o pico de concentração de glicose, elas se distanciaram progressivamente com o tratamento da acarbose atingindo os níveis iniciais mais rapidamente. O modelo adotado, com uma única unidade amostral, mostrou resultados similares a outros estudos com maior número de unidades amostrais, isto é, a acarbose pode atenuar consideravelmente a glicemia após ingestão de amido.


Asunto(s)
Ratas , Acarbosa , Diabetes Mellitus , Glucosa
4.
Dent. press endod ; 6(1): 15-19, jan.-abr. 2016. ilus, tab
Artículo en Portugués | LILACS | ID: lil-786767

RESUMEN

Introdução: a utilização dos localizadores apicais eletrônicos (LAEs) é imprescindível na obtenção do comprimento real de trabalho (CRT), visto que o método radiográ co apresenta limitações. Objetivo: o objetivo deste estudo foi comparar a e cácia e acurácia de três LAEs (Root ZX, NovApex e Justy II), na determinação do CRT. Métodos: trinta incisivos humanos extraídos foram selecionados. Após a abertura coronária e preparo cervical, uma lima tipo K #15 foi introduzida no interior do canal até sua ponta atingir o forame apical; o comprimento real foi observado utilizando-se um paquímetro digital e magnificação com microscópio operatório (25x). O CRT de cada dente foi obtido subtraindo-se 1mm do comprimento da lima. Então, os dentes foram inseridos, até o nível cervical, em uma esponja para arranjos orais, posicionada em uma caixa plástica transparente, embebida em solução salina a 0,9%. Um endodontista experiente e calibrado realizou 30 mensurações com cada aparelho, perfazendo um total de 90 medidas. Resultados: por meio da análise de variância (ANOVA), com a qual se verificou a e cácia, demonstrou-se que não houve diferença estatisticamente signi cativa (p = 0,4505) entre os aparelhos. Na comparação entre os três LAEs quanto ao CRT, não houve diferença estatisticamente signi cativa: Root ZX (p = 0,3418); NovApex (p = 0,3031) e Justy II (p = 0,4080). Entretanto na análise de regressão por meio do grá co de dispersão, o NovApex mostrou melhor acurácia do que os outros localizadores apicais eletrônicos, com precisão de 93%. Conclusões: os LAEs utilizados foram eficazes; contudo, apesar de o NovApex ter apresentado maior acurácia, mais estudos devem ser realizados.


Asunto(s)
Endodoncia , Instrumentos Dentales/tendencias , Odontometría , Ápice del Diente , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA