Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Surg Endosc ; 30(4): 1419-31, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26201410

RESUMEN

BACKGROUND: Surgical skill evaluation ordinarily requires tedious video review and survey completion, while new automatic approaches focus on evaluating the quality of the surgeon's movements in free space. Robotic surgical instrument vibrations are simple to measure and physically correspond to how roughly instruments are handled, but they have yet to be studied as a measure of technical surgical skill. METHODS: Thirteen surgeons used a robotic surgery system (da Vinci S by Intuitive Surgical) to perform four trials each of peg transfer (PT), needle pass (NP), and intracorporeal suturing (IS). Completion time, instrument vibrations, and applied forces were measured for each trial; root mean square (RMS) and total sum of squares (TSS) were calculated from both the vibration and force recordings. Four experienced surgeons blindly assessed the task videos using a Global Rating Scale (GRS), and skill metrics were compared between the eight novices and five experienced participants. Stepwise regression was performed to predict GRS score from objective skill metrics. The concurrent validity of each metric was evaluated using receiver operating characteristic (ROC) analysis. RESULTS: The GRS demonstrated excellent internal consistency (Cronbach's α = 0.91) and strong inter-rater reliability (ICC = 0.84). Compared to novices, experienced surgeons earned higher GRS scores and performed tasks with lower vibration magnitudes, lower forces, and shorter completion times in 15 of 18 task-metric combinations (p values ranging from 0.042 to <0.001). ROC analysis demonstrated that including vibration and force magnitudes along with completion time in skill prediction models improves the objective classification of subjects as novice or experienced for all tasks studied (PT: 90% sensitivity, 75% specificity; NP: 85% sensitivity, 84% specificity; suturing: 100% sensitivity, 100% specificity). CONCLUSIONS: RMS and TSS instrument vibrations are novel construct-valid measures of robotic surgical skill that enable the development of objective skill assessment models comparable to observer-based ratings.


Asunto(s)
Competencia Clínica , Robótica/instrumentación , Cirujanos/normas , Adulto , Diseño de Equipo , Femenino , Humanos , Curva ROC , Reproducibilidad de los Resultados , Vibración
2.
IEEE Trans Neural Syst Rehabil Eng ; 23(1): 51-63, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25486644

RESUMEN

Tactile cues generated from lightweight, wearable actuators can help users learn new motions by providing immediate feedback on when and how to correct their movements. We present a vibrotactile motion guidance system that measures arm motions and provides vibration feedback when the user deviates from a desired trajectory. A study was conducted to test the effects of vibrotactile guidance on a subject's ability to learn arm motions. Twenty-six subjects learned motions of varying difficulty with both visual (V), and visual and vibrotactile (VVT) feedback over the course of four days of training. After four days of rest, subjects returned to perform the motions from memory with no feedback. We found that augmenting visual feedback with vibrotactile feedback helped subjects reduce the root mean square (rms) angle error of their limb significantly while they were learning the motions, particularly for 1DOF motions. Analysis of the retention data showed no significant difference in rms angle errors between feedback conditions.


Asunto(s)
Brazo/fisiología , Retroalimentación Psicológica/fisiología , Aprendizaje/fisiología , Algoritmos , Retroalimentación Sensorial/fisiología , Humanos , Memoria/fisiología , Movimiento/fisiología , Práctica Psicológica , Rehabilitación/métodos , Robótica , Tacto/fisiología , Vibración
3.
Surg Endosc ; 27(2): 656-64, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22806517

RESUMEN

BACKGROUND: Robotic minimally invasive surgery (RMIS) lacks the haptic (kinesthetic and tactile) cues that surgeons are accustomed to receiving in open and laparoscopic surgery. We previously introduced a method for adding tactile and audio feedback of tool vibrations to RMIS systems, creating sensations similar to what one feels and hears when using a laparoscopic tool. Our prior work showed that surgeons performing box-trainer tasks significantly preferred having this feedback and believed that it helped them concentrate on the task, but we did not know how well our approach would work in a clinically relevant setting. This study constituted the first in vivo test of our system. METHODS: Accelerometers that measure tool vibrations were mounted to the patient-side manipulators of a da Vinci S surgical system. The measured vibrations were recorded and presented to the surgeon through vibrotactile and audio channels while two transperitoneal nephrectomies and two mid-ureteral dissections with uretero-ureterostomy were completed on a porcine model. We examined 30 minutes of resulting video to identify and tag manipulation events, aiming to determine whether our system can measure significant and meaningful tool vibrations during in vivo procedures. RESULTS: A total of 1,404 manipulation events were identified. Analysis of each event's accelerations indicated that 82 % of these events resulted in significant vibrations. The magnitude of the accelerations measured for different manipulation events varied widely, with hard contact causing the largest cues. CONCLUSIONS: This study demonstrates the feasibility of providing tool vibration feedback during in vivo RMIS. Significant tool vibrations were reliably measured for the majority of events during standard urological procedures on a porcine model, while real-time, naturalistic tactile and audio tool vibration feedback was provided to the surgeon. The feedback system's modules were easily implemented outside the sterile field of the da Vinci S and did not interfere with the surgical procedure.


Asunto(s)
Retroalimentación Fisiológica , Robótica/instrumentación , Tacto , Vibración , Humanos
4.
J Robot Surg ; 7(4): 351-8, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27001874

RESUMEN

We have developed a system for measuring and recording the high-frequency vibrations that characterize instrument interactions during minimally invasive robotic surgery. Consisting of simple circuitry and a DVD recorder, this system is low-cost and easily implementable, requires no sterilization, and enables measurement of a validated, objective technical skill metric in both the simulated setting and the operating room. The vibration recordings of fourteen sleeve gastrectomies were processed by segmenting the operation into seven phases and calculating the root mean square (RMS) vibration within each phase. Statistical analysis showed that the observed differences match expectations drawn from knowledge of the operation, substantiating the premise that RMS vibration provides a good measure of the intensity of instrument interactions during live robotic surgery.

5.
IEEE Trans Neural Syst Rehabil Eng ; 18(1): 58-66, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20071271

RESUMEN

We present a new wearable haptic device that provides a sense of position and motion by inducing rotational skin stretch on the user's skin. In the experiments described in this paper, the device was used to provide proprioceptive feedback from a virtual prosthetic arm controlled with myoelectric sensors on the bicep and tricep muscles in 15 able-bodied participants. Targeting errors in blind movements with the haptic device were compared to cases where no feedback and contralateral proprioception were provided. Average errors were lower with the device than with no feedback but larger than with contralateral proprioceptive feedback. Participants also had lower visual demand with the device than with no feedback while tracking a 30 ( degrees ) moving range. The results indicate that the rotational skin stretch may ultimately be effective for proprioceptive feedback in myoelectric prostheses, particularly when vision is otherwise occupied.


Asunto(s)
Miembros Artificiales , Electromiografía/instrumentación , Contracción Muscular/fisiología , Estimulación Física/instrumentación , Propiocepción/fisiología , Fenómenos Fisiológicos de la Piel , Tacto/fisiología , Adulto , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Diseño de Prótesis , Rotación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...