Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Med Biol ; 62(18): 7451-7470, 2017 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-28796644

RESUMEN

Ultrasound and microbubbles have been shown to accelerate the breakdown of blood clots both in vitro and in vivo. Clinical translation of this technology is still limited, however, in part by inefficient microbubble delivery to the thrombus. This study examines the obstacles to delivery posed by fluid dynamic conditions in occluded vasculature and investigates whether magnetic targeting can improve microbubble delivery. A 2D computational fluid dynamic model of a fully occluded Y-shaped microarterial bifurcation was developed to determine: (i) the fluid dynamic field in the vessel with inlet velocities from 1-100 mm s-1 (corresponding to Reynolds numbers 0.25-25); (ii) the transport dynamics of fibrinolytic drugs; and (iii) the flow behavior of microbubbles with diameters in the clinically-relevant range (0.6-5 µm). In vitro experiments were carried out in a custom-built microfluidic device. The flow field was characterized using tracer particles, and fibrinolytic drug transport was assessed using fluorescence microscopy. Lipid-shelled magnetic microbubbles were fluorescently labelled to determine their spatial distribution within the microvascular model. In both the simulations and experiments, the formation of laminar vortices and an abrupt reduction of fluid velocity were observed in the occluded branch of the bifurcation, severely limiting drug transport towards the occlusion. In the absence of a magnetic field, no microbubbles reached the occlusion, remaining trapped in the first vortex, within 350 µm from the bifurcation center. The number of microbubbles trapped within the vortex decreased as the inlet velocity increased, but was independent of microbubble size. Application of a magnetic field (magnetic flux density of 76 mT, magnetic flux density gradient of 10.90 T m-1 at the centre of the bifurcation) enabled delivery of microbubbles to the occlusion and the number of microbubbles delivered increased with bubble size and with decreasing inlet velocity.


Asunto(s)
Arterias/efectos de los fármacos , Sistemas de Liberación de Medicamentos , Fibrinolíticos/administración & dosificación , Fenómenos Magnéticos , Microburbujas , Arterias/diagnóstico por imagen , Medios de Contraste , Humanos , Lípidos/química , Ultrasonografía
2.
J Phys Condens Matter ; 25(8): 086003, 2013 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-23361044

RESUMEN

The magnetic hysteresis loops of an aged Cu(81.2)Mn(18.8) alloy sample exhibit significant asymmetric reversal at low temperatures, with high sensitivity to the cooling field. Much of the observed behaviour was explained by considering an ensemble of coherent, ferromagnetically aligned clusters interacting with a randomized spin glass component. A modified Stoner-Wohlfarth model was successfully applied to the data using Monte Carlo simulations, in order to gain insight into the dependence of the cluster shape anisotropy and exchange anisotropy on the cooling field. This model suggested that ferromagnetic clusters grow as the cooling field increases.


Asunto(s)
Aleaciones/química , Cobre/química , Vidrio/química , Campos Magnéticos , Imanes/química , Manganeso/química , Anisotropía , Simulación por Computador , Modelos Teóricos , Método de Montecarlo , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...