Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
2.
Infect Control Hosp Epidemiol ; 43(10): 1466-1472, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34503593

RESUMEN

BACKGROUND: Microbiological surveillance of bronchoscopes and automatic endoscope reprocessors (AERs)/washer disinfectors as a quality control measure is controversial. Experts also are divided on the infection risks associated with bronchoscopic procedures. OBJECTIVE: We evaluated the impact of routine microbiological surveillance and audits of cleaning/disinfection practices on contamination rates of reprocessed bronchoscopes. DESIGN: Audits were conducted of reprocessing procedures and microbiological surveillance on all flexible bronchoscopes used from January 2007 to June 2020 at a teaching hospital in France. Contamination rates per year were calculated and analyzed using a Poisson regression model. The risk factors for microbiological contamination were analyzed using a multivariable logistical regression model. RESULTS: In total, 478 microbiological tests were conducted on 91 different bronchoscopes and 57 on AERs. The rate of bronchoscope contamination significantly decreased between 2007 and 2020, varying from 30.2 to 0% (P < .0001). Multivariate analysis confirmed that retesting after a previous contaminated test was significantly associated with higher risk of bronchoscope contamination (OR, 2.58; P = .015). This finding was explained by the persistence of microorganisms in bronchoscopes despite repeated disinfections. However, the risk of persistent contamination was not associated with the age of the bronchoscope. CONCLUSIONS: Our results confirm that bronchoscopes can remain contaminated despite repeated reprocessing. Routine microbial testing of bronchoscopes for quality assurance and audit of decontamination and disinfection procedures can improve the reprocessing of bronchoscopes and minimize the rate of persistent contamination.


Asunto(s)
Broncoscopios , Contaminación de Equipos , Humanos , Broncoscopios/microbiología , Contaminación de Equipos/prevención & control , Seguridad del Paciente , Desinfección/métodos , Broncoscopía
3.
Eur J Clin Microbiol Infect Dis ; 39(11): 2185-2194, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32519215

RESUMEN

To increase the knowledge about S. capitis in the neonatal setting, we conducted a nationwide 3-month survey in 38 neonatal intensive care units (NICUs) covering 56.6% of French NICU beds. We demonstrated 14.2% of S. capitis BSI (S.capBSI) among nosocomial BSIs. S.capBSI incidence rate was 0.59 per 1000 patient-days. A total of 55.0% of the S.capBSIs were late onset catheter-related BSIs. The S. capitis strains infected preterm babies (median gestational age 26 weeks, median birth weight 855 g). They were resistant to methicillin and aminoglycosides and belonged to the NRCS-A clone. Evolution was favorable in all but one case, following vancomycin treatment.


Asunto(s)
Sepsis/epidemiología , Infecciones Estafilocócicas/epidemiología , Staphylococcus capitis/aislamiento & purificación , Antibacterianos/farmacología , Antibacterianos/uso terapéutico , Infecciones Relacionadas con Catéteres/tratamiento farmacológico , Infecciones Relacionadas con Catéteres/epidemiología , Infecciones Relacionadas con Catéteres/etiología , Farmacorresistencia Bacteriana Múltiple , Femenino , Francia/epidemiología , Humanos , Recién Nacido , Recien Nacido Prematuro , Unidades de Cuidado Intensivo Neonatal , Masculino , Sepsis/tratamiento farmacológico , Sepsis/etiología , Infecciones Estafilocócicas/tratamiento farmacológico , Infecciones Estafilocócicas/etiología , Staphylococcus capitis/efectos de los fármacos
4.
Curr Res Transl Med ; 68(1): 23-28, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31787568

RESUMEN

PURPOSE OF THE STUDY: Invasive aspergillosis (IA) is the most prevalent invasive fungal disease (IFD) in neutropenic patients. Environment is the main source of Aspergillus spores aerosolization especially during building construction. International guidelines recommend mechanical protection during hospital building works; otherwise the use of antifungal prophylaxis is not clearly indicated. Our objective was to determine the efficacy of antifungal prophylaxis by posaconazole on IA incidence in acute myeloid leukemia population and to analyse the benefit of this prophylaxis and HEPA-filters during hospital buildings works. PATIENTS AND METHODS: We included patients treated for acute myeloid leukemia at Brest teaching hospital from January 2009 to December 2015. We compared incidence of IA in the group treated by posaconazole from 2012 to 2015 to the incidence of IA in the first group who did not receive antifungal prophylaxis (from 2009 to 2011). The one-year overall survival was also analyzed using the Kaplan-Meier method. RESULTS: 245 patients were enrolled including 151 treated with posaconazole. 23 IA were diagnosed between 2009 and 2011 (without antifungal prophylaxis), then 31 between 2012 and 2015 (with posaconazole) without statistical difference between the incidence densities (0.34 per 100 hospitalization-days vs. 0.30 per 100 hospitalization-days, p = 0.71). Incidence density of IA increased during building works (2.40 per 100 hospitalization-days vs. 0.28 per 100 hospitalization-days, p < 0.0001). The incidence density of IA significantly decreased during construction periods when posaconazole prophylaxis was used (1.59 per 100 hospitalization-days vs. 4.87 per 100 hospitalization-days p < 0.0001). CONCLUSION: Our study suggests, for the first time, the interest of antifungal prophylaxis in addition to HEPA filtration in prevention of IA during hospital building works.


Asunto(s)
Antifúngicos/uso terapéutico , Aspergilosis/prevención & control , Infecciones Fúngicas Invasoras/prevención & control , Leucemia Mieloide Aguda/complicaciones , Triazoles/uso terapéutico , Adulto , Aerosoles , Filtros de Aire , Microbiología del Aire , Contaminación del Aire Interior , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Aspergilosis/epidemiología , Aspergillus/efectos de los fármacos , Aspergillus/aislamiento & purificación , Aspergillus/fisiología , Terapia Combinada , Exposición a Riesgos Ambientales , Neutropenia Febril/complicaciones , Femenino , Filtración , Francia , Trasplante de Células Madre Hematopoyéticas , Arquitectura y Construcción de Hospitales , Hospitales de Enseñanza , Humanos , Incidencia , Infecciones Fúngicas Invasoras/epidemiología , Estimación de Kaplan-Meier , Leucemia Mieloide Aguda/mortalidad , Leucemia Mieloide Aguda/terapia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Esporas Fúngicas
10.
Endoscopy ; 48(8): 704-10, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27200525

RESUMEN

BACKGROUND AND STUDY AIM: Infectious outbreaks associated with the use of gastrointestinal endoscopes have increased in line with the spread of highly resistant bacteria. The aim of this study was to determine the measures required to improve microbial quality surveillance of gastrointestinal endoscopes. METHODS: We reviewed the results of all microbiological surveillance testing of gastrointestinal endoscopes and automatic endoscope reprocessors (AERs) performed at Brest Teaching Hospital from 1 January 2008 to 1 June 2015. We analyzed the influence of the time of incubation on the rate of positive results using the Kaplan - Meier method. We also studied risk factors for gastrointestinal endoscope contamination using a multivariable logistic regression model. RESULTS: Over the study period, 1100 microbiological tests of gastrointestinal endoscopes (n = 762) and AERs (n = 338) were performed. A total of 264 endoscope tests (34.6 %) showed a level of contamination higher than the target. After 2 days of incubation, contamination was apparent in only 55.5 % of the endoscopes that were later shown to be contaminated (95 % confidence interval [CI] 49.2 - 61.8). Multivariable analysis showed that the use of storage cabinets for heat-sensitive endoscopes significantly reduced the risk of endoscope contamination (odds ratio [OR] 0.23, 95 %CI 0.09 - 0.54; P  < 0.001) and that the use of endoscopes older than 4 years significantly increased this risk (OR ≥ 6 vs. < 2 years 2.92, 95 %CI 1.63 - 5.24; P < 0.001). CONCLUSIONS: Microbiological culture technique, mainly incubation duration, strongly influenced the results of endoscope sampling. Samples should be cultured for more than 2 days to improve the detection of contaminated endoscopes. Particular attention should be paid to endoscopes older than 2 years and to those that are not stored in storage cabinets for heat-sensitive endoscopes.


Asunto(s)
Desinfección/normas , Endoscopios Gastrointestinales/microbiología , Contaminación de Equipos , Garantía de la Calidad de Atención de Salud , Bacterias/aislamiento & purificación , Candida/aislamiento & purificación , Infección Hospitalaria/prevención & control , Equipo Reutilizado/normas , Humanos , Técnicas Microbiológicas , Factores de Tiempo
16.
Infect Control Hosp Epidemiol ; 36(9): 1100-2, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26036960

RESUMEN

Storage cabinets for heat-sensitive endoscopes (SCHEs) are designed to store gastrointestinal (GI) endoscopes in a clean, dry and well-ventilated cupboard to prevent microbiological proliferation. The use of SCHEs in a GI endoscopy unit has significally reduced the rate of contaminated endoscopes (13.0% vs 45.0%, P<.001).


Asunto(s)
Desinfección/instrumentación , Endoscopios Gastrointestinales/microbiología , Ambiente Controlado , Contaminación de Equipos/prevención & control , Control de Infecciones/métodos , Recuento de Colonia Microbiana , Infección Hospitalaria/prevención & control , Desinfección/métodos , Desinfección/normas , Equipo Reutilizado
18.
Cytokine ; 45(2): 92-8, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19128984

RESUMEN

BACKGROUND: Acute renal dysfunction (ARD) is common after cardiac surgery with cardiopulmonary bypass (CPB). CPB results in a sudden systemic inflammatory response. Systemic and local pro-inflammatory cytokines synthesis has been linked with sub-clinical renal injury, especially tubular lesions. Therefore, we sought to assess the systemic synthesis pro-inflammatory cytokines and its association with perioperative ARD after cardiac surgery with CPB. METHODS: Sixty-two patients undergoing cardiac surgery with CPB were prospectively included. Four groups of patients were defined according to blood creatinine increase: no ARD (less than 25% increase), faint ARD (25-50% increase), moderate ARD (50-100% increase), severe ARD (more than 100% increase). RESULTS: Within the 48 post-operative hours was ARD observed as no dysfunction (41.9%), faint (32.2%), moderate (16.1%), severe (9.6%). One patient had to undergo a dialysis. Pre-operative characteristics were homogenous between the four groups excepted the left ventricle ejection fraction. ARD was associated with a low urinary output with high sodium excretion fraction. Significant increase of IL-6 level occurred when patients underwent a severe ARD despite no significant differences for the CRP and TNF-alpha concentrations. CONCLUSION: Severe acute renal dysfunction after cardiac surgery with CPB is associated with a significant increased IL-6 systemic production.


Asunto(s)
Lesión Renal Aguda , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Puente Cardiopulmonar/efectos adversos , Interleucina-6/sangre , Complicaciones Posoperatorias/sangre , Lesión Renal Aguda/sangre , Lesión Renal Aguda/etiología , Anciano , Creatinina/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Urea/sangre
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...