Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Respir Res ; 25(1): 12, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38178128

RESUMEN

BACKGROUND: There are relatively few data about the ultrasound evaluation of pleural line in patients with respiratory failure. We measured the pleural line thickness during different phases of the respiratory cycle in neonates with and without acute respiratory failure as we hypothesized that this can significantly change. METHODS: Prospective, observational, cohort study performed in an academic tertiary neonatal intensive care unit recruiting neonates with transient tachypnoea of the neonate (TTN), respiratory distress syndrome (RDS) or neonatal acute respiratory distress syndrome (NARDS). Neonates with no lung disease (NLD) were also recruited as controls. Pleural line thickness was measured with high-frequency ultrasound at end-inspiration and end-expiration by two different raters. RESULTS: Pleural line thickness was slightly but significantly higher at end-expiration (0.53 [0.43-0.63] mm) than at end-inspiration (0.5 [0.4-0.6] mm; p = 0.001) for the whole population. End-inspiratory (NLD: 0.45 [0.38-0.53], TTN: 0.49 [0.43-0.59], RDS: 0.53 [0.41-0.62], NARDS: 0.6 [0.5-0.7] mm) and -expiratory (NLD: 0.47 [0.42-0.56], TTN: 0.48 [0.43-0.61], RDS: 0.53 [0.46-0.65], NARDS: 0.61 [0.54-0.72] mm) thickness were significantly different (overall p = 0.021 for both), between the groups although the absolute differences were small. The inter-rater agreement was optimal (ICC: 0.95 (0.94-0.96)). Coefficient of variation was 2.8% and 2.5% for end-inspiratory and end-expiratory measurements, respectively. These findings provide normative data of pleural line thickness for the most common forms of neonatal acute respiratory failure and are useful to design future studies to investigate possible clinical applications.


Asunto(s)
Síndrome de Dificultad Respiratoria del Recién Nacido , Síndrome de Dificultad Respiratoria , Insuficiencia Respiratoria , Humanos , Recién Nacido , Estudios de Cohortes , Estudios Prospectivos , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Síndrome de Dificultad Respiratoria/terapia , Síndrome de Dificultad Respiratoria del Recién Nacido/diagnóstico por imagen , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Insuficiencia Respiratoria/diagnóstico por imagen
2.
Pediatr Crit Care Med ; 24(4): e196-e201, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36728157

RESUMEN

OBJECTIVES: A new device is available for neonates needing extracorporeal renal replacement therapy. We reviewed the use of this device (in continuous venovenous hemofiltration [CVVH] mode) in term or preterm neonates affected by multiple organ dysfunction syndrome (MODS) with fluid overload. DESIGN: Case series. SETTING: Academic specialized referral neonatal ICU (NICU) with expertise on advanced life support and monitoring. PATIENTS: Neonates with MODS and fluid overload despite conventional treatments and receiving at least one CVVH session. INTERVENTION: CVVH with the Cardio-Renal Pediatric Dialysis Emergency Machine. MEASUREMENTS AND MAIN RESULTS: Ten (three preterm) neonates were treated using 18 consecutive CVVH sessions. All patients were in life-threatening conditions and successfully completed the CVVH treatments, which almost always lasted 24 hr/session, without major side effects. Three neonates survived and were successfully discharged from hospital with normal follow-up. CVVH reduced fluid overload (before versus after represented as a weight percentage: 23.5% [12-34%] vs 14.6% [8.2-24.1%]; p = 0.006) and lactate (before versus after: 4.6 [2.9-12.1] vs 2.9 mmol/L [2.3-5.5 mmol/L]; p = 0.001). CVVH also improved the Pa o2 to Fio2 (before vs after: 188 mm Hg [118-253 mm Hg] vs 240 mm Hg [161-309 mm Hg]; p = 0.003) and oxygenation index (before vs after: 5.9 [3.8-14.6] vs 4 [2.9-11]; p = 0.002). The average cost of CVVH in these patients was minor (≈3%) in comparison with the median total cost of NICU care per patient. CONCLUSIONS: We have provided CVVH to critically ill term and preterm neonates with MODS. CVVH improved fluid overload and oxygenation. The cost of CVVH was minimal compared with the overall cost of neonatal intensive care.


Asunto(s)
Lesión Renal Aguda , Terapia de Reemplazo Renal Continuo , Hemofiltración , Desequilibrio Hidroelectrolítico , Recién Nacido , Niño , Humanos , Hemofiltración/efectos adversos , Insuficiencia Multiorgánica/etiología , Insuficiencia Multiorgánica/terapia , Neonatólogos , Diálisis Renal , Desequilibrio Hidroelectrolítico/etiología , Desequilibrio Hidroelectrolítico/terapia , Lesión Renal Aguda/terapia , Lesión Renal Aguda/etiología
3.
Ital J Pediatr ; 48(1): 63, 2022 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-35505374

RESUMEN

BACKGROUND: For infants exposed in utero to Toxoplasma gondii, current guidelines recommend monitoring the specific antibody titer until 12 months of age. In this study, we investigated the antibody titer decay in the mother-infant dyad. METHODS: This is a single center, population-based cohort study of neonates referred for prenatal exposure to Toxoplasma gondii from January 2014 to December 2020. All infants underwent clinical, laboratory, and instrumental investigation for at least 12 months. RESULTS: A total of 670 eligible neonates were referred to the Perinatal Infection Unit of the University Federico II of Naples. 636 (95%) completed the serological follow up until 12 months. Specific IgG antibodies negativization occurred in 628 (98.7%) within 5 months. At 9 and 12 months, all patients had negative IgG. An initial neonatal IgG antibody titer ≥ 200 IU/ml was associated with a longer time to negativization (184 [177.5;256] days when above threshold vs. 139.5 [101;179] days when below it; p < 0.001). Maternal IgG antibody titer ≥ 200 IU/ml at childbirth was also associated to delayed time to negativization in the infant (179 [163;184] days above the threshold vs 125 [96.8;178] days below it; p < 0.001). Specific antibody negativization was irreversible in all patients. CONCLUSIONS: Lower anti-Toxoplasma antibody titers detected at birth in the mother-infant-dyad lead to an earlier and irreversible negativization. This information allows for customisation of the infant follow up program and avoids invasive and expensive tests.


Asunto(s)
Toxoplasma , Estudios de Cohortes , Femenino , Humanos , Inmunoglobulina G , Lactante , Recién Nacido , Madres , Parto , Embarazo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...