1.
Clin Oncol (R Coll Radiol) ; 30(4): 233-242, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29317145

RESUMEN

AIMS: To determine quality of life (QoL) outcomes after palliation of pain from bone metastases using magnetic resonance-guided high intensity focused ultrasound (MR-guided HIFU), measured using the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C15-PAL and the QLQ-BM22 questionnaires. MATERIALS AND METHODS: Twenty patients undergoing MR-guided HIFU in an international multicentre trial self-completed the QLQ-C15-PAL and QLQ-BM22 questionnaires before and on days 7, 14, 30, 60 and 90 post-treatment. Descriptive statistics were used to represent changes in symptom and functional scales over time and to determine their clinical significance. QoL changes were compared in pain responders and non-responders (who were classified according to change in worst pain score and analgesic intake, between baseline and day 30). RESULTS: Eighteen patients had analysable QoL data. Clinically significant improvements were seen in the QoL scales of physical functioning, fatigue, appetite loss, nausea and vomiting, constipation and pain in the 53% of patients who were classified as responders at day 30. No significant changes were seen in the 47% of patients who were non-responders at this time point. CONCLUSION: Local treatment of pain from bone metastases with MR-guided HIFU, even in the presence of disseminated malignancy, has a substantial positive effect on physical functioning, and improves other symptomatic QoL measures. This indicated a greater response to treatment over and above pain control alone. MR-guided HIFU is non-invasive and should be considered for patients with localised metastatic bone pain and poor QoL.


Asunto(s)
Neoplasias Óseas/terapia , Cuidados Paliativos/métodos , Calidad de Vida , Terapia por Ultrasonido/métodos , Adulto , Anciano , Neoplasias Óseas/secundario , Dolor en Cáncer/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Encuestas y Cuestionarios
2.
Int J Pharm ; 505(1-2): 52-60, 2016 May 30.
Artículo en Inglés | MEDLINE | ID: mdl-27041126

RESUMEN

Oil depots are parenteral drug formulations meant for sustained release of lipophilic compounds. According to mass transport models, the drug-release rate from these injections is determined by the surface area of the oil depot. Until now, the size of the surface area of injected depots has not been assessed, however. MRI provides an excellent possibility to distinguish between water and adipose tissue. The aim of this study was to investigate whether MRI can be used to determine the shape and hence the surface area of oil depots in muscle tissue. The developed MRI-scan protocol is demonstrated to be suitable for visualising oil depots. It was applied to determine the surface area of 0.5mL oil, i.m. injected in healthy volunteers. The mean (±RSD) surface area and volume of the depots recovered after injection was 755.4mm(2) (±26.5) and 520.1mm(3) (±24.6). It is shown that the depot disappearance from the injection site is very variable between volunteers. It is suggested that the oil is first solubilized and subsequently distributed. In all cases, the oil was not detectable after 14days. These factors are relevant for the understanding of the mechanism by which compounds are released out of oil depots.


Asunto(s)
Tejido Adiposo/metabolismo , Imagen por Resonancia Magnética/métodos , Músculos/metabolismo , Aceite de Sésamo/administración & dosificación , Adulto , Animales , Preparaciones de Acción Retardada , Humanos , Inyecciones Intramusculares , Masculino , Persona de Mediana Edad , Aceite de Sésamo/química , Aceite de Sésamo/farmacocinética , Porcinos , Factores de Tiempo , Distribución Tisular , Agua/química
3.
Med Phys ; 42(8): 4685-97, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26233196

RESUMEN

PURPOSE: One of the major issues in high intensity focused ultrasound ablation of abdominal lesions is obstruction of the ultrasound beam by the thoracic cage. Beam shaping strategies have been shown by several authors to increase focal point intensity while limiting rib exposure. However, as rib obstruction leaves only part of the aperture available for energy transmission, conserving total emitted acoustic power, the intensity in the near-field tissues inherently increases after beam shaping. Despite of effective rib sparing, those tissues are therefore subjected to increased risk of thermal damage. In this study, for a number of clinically representative intercostal sonication geometries, modeling clinically available hardware, the effect of beam shaping on both the exposure of the ribs and near-field to acoustic energy was evaluated and the implications for the volumetric ablation rate were addressed. METHODS: A relationship between rib temperature rise and acoustic energy density was established by means of in vivo MR thermometry and simulations of the incident acoustic energy for the corresponding anatomies. This relationship was used for interpretation of rib exposure in subsequent numerical simulations in which rib spacing, focal point placement, and the focal point trajectory were varied. The time required to heat a targeted region to 65 °C was determined without and with the application of beam shaping. The required sonication time was used to calculate the acoustic energy density at the fat-muscle interface and at the surface of the ribs. At the fat-muscle interface, exposure was compared to available literature data and rib exposure was interpreted based on the earlier obtained relation between measured temperature rise and simulated acoustic energy density. To estimate the volumetric ablation rate, the cool-down time between periods of energy exposure was estimated using a time-averaged power limit of 100 kJ/h. RESULTS: At the level of the ribs, the temperature rise-energy density proportionality constant was estimated to be 6.0-7.6 °C/(J/mm(2)). Beam shaping by the geometric shadow method typically reduces the acoustic intensity a factor of 2, considering the 1 cm(2) with the highest exposure. For a 4 mm diameter circular sonication trajectory, the near-field energy limit of 2.5 J/mm(2) was exceeded for all considered geometries. The estimated rib temperature was in all but one (sonication 50 mm behind the ribs, with 15 mm rib spacing and a 4 mm diameter circular sonication trajectory) of the considered scenarios within acceptable limits. For those sonication scenarios where a single sonication is considered safe both in terms of near-field as well as rib heating, volumetric ablation rates in the order of 1 ml/h are estimated. CONCLUSIONS: Intercostal sonication is associated with an increased risk of near-field overheating. This risk is strongly dependent on the considered rib spacing, the placement of the focus behind the ribs, and the selected sonication trajectory. For the hardware under simulation, obstruction by the thoracic cage renders ablations of clinically relevant volumes within a practical time-frame unfeasible in a large part of the liver. Improvements maybe expected from transducer designs with a larger active surface and/or nonlinear sonication strategies.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Hígado/cirugía , Tejido Adiposo/fisiología , Simulación por Computador , Estudios de Factibilidad , Ultrasonido Enfocado de Alta Intensidad de Ablación/instrumentación , Humanos , Hígado/fisiopatología , Modelos Biológicos , Músculos/fisiología , Órganos en Riesgo , Costillas/anatomía & histología , Costillas/fisiología , Temperatura
4.
Phys Med Biol ; 60(14): 5527-42, 2015 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-26133986

RESUMEN

MR-guided HIFU ablation is a promising technique for the non-invasive treatment of breast cancer. A phase I study was performed to assess the safety and treatment accuracy and precision of MR-HIFU ablation in breast cancer patients (n=10) using a newly developed MR-HIFU platform dedicated to applications in the breast. In this paper a technical analysis of the performance of the dedicated breast MR-HIFU system during breast tumors ablation is described. The main points of investigation were the spatial targeting accuracy and precision of the system and the performance of real-time respiration-corrected MR thermometry.The mean targeting accuracy was in the range of 2.4-2.6 mm, whereas the mean targeting precision was in the range of 1.5-1.8 mm. To correct for respiration-induced magnetic field fluctuations during MR temperature mapping a look-up-table (LUT)-based correction method was used. An optimized procedural sedation protocol in combination with the LUT-based correction method allowed for precise MR thermometry during the ablation procedure (temperature standard deviation <3 °C). No unwanted heating in the near field (i.e. skin) nor in the far field (pectoral muscle) was detected.The newly developed dedicated breast MR-HIFU system allows for safe, accurate and precise ablation of breast tumors.


Asunto(s)
Neoplasias de la Mama/cirugía , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Termometría/métodos , Mama/citología , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Estudios de Casos y Controles , Medios de Contraste/metabolismo , Femenino , Voluntarios Sanos , Humanos , Invasividad Neoplásica , Temperatura
5.
Eur J Vasc Endovasc Surg ; 50(3): 331-40, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26036808

RESUMEN

OBJECTIVES/BACKGROUND: To examine the additional diagnostic value of magnetic resonance imaging (MRI) after administration of a weak albumin binding contrast agent in post-endovascular aneurysm repair (EVAR) patients with aneurysm growth with no or uncertain endoleak after computed tomography angiography (CTA). METHODS: This was a prospective diagnostic cross sectional study carried out between April 2011 and August 2013. MRI was performed in all patients with aneurysm growth≥5 mm after EVAR implantation and no or uncertain endoleak on CTA, or the inability, on CTA, to identify the source of a visible endoleak. All MRI scans were performed on a 1.5 T clinical MRI scanner after administration of a weak albumin binding contrast agent. The presence of endoleaks was assessed by visually comparing pre- and post-contrast T1-weighted images with fat suppression. Post-contrast images were acquired 5 and 15 minutes after contrast administration. RESULTS: Twenty-nine patients (26 men; 90%) with a median age of 74 years (interquartile range [IQR] 67-76) were included. The median interval between EVAR and MRI was 39 months (IQR 20-50). The median increase in maximum aneurysm diameter during total follow up after EVAR was 11 mm (IQR 6-17). At CTA, 16 patients (55%) had no detectable endoleak, five patients (17%) had suspected but uncertain endoleak, and eight patients had a definite endoleak (28%). On the post-contrast MRI images, endoleak was observed in 24 patients (83%). In all patients with uncertain endoleak on CTA, endoleak was detected with MRI. For type II endoleaks, feeding vessels were detected in 22/23 patients (96%) and these were all, except one, lumbar arteries. CONCLUSION: In patients with enlarging aneurysms of unknown origin after EVAR, MRI with a weak albumin binding contrast agent has additional value for both the detection and determination of the origin of the endoleak.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Medios de Contraste , Endofuga/diagnóstico , Procedimientos Endovasculares/efectos adversos , Angiografía por Resonancia Magnética , Meglumina/análogos & derivados , Compuestos Organometálicos , Albúmina Sérica/metabolismo , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico , Aortografía/métodos , Medios de Contraste/metabolismo , Estudios Transversales , Endofuga/sangre , Endofuga/etiología , Endofuga/terapia , Femenino , Humanos , Masculino , Meglumina/metabolismo , Compuestos Organometálicos/metabolismo , Valor Predictivo de las Pruebas , Estudios Prospectivos , Unión Proteica , Albúmina Sérica Humana , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
6.
Osteoarthritis Cartilage ; 21(7): 943-9, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23583465

RESUMEN

OBJECTIVE: Delayed gadolinium enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC) facilitates non-invasive evaluation of the glycosaminoglycan content in articular cartilage. The primary aim of this study was to show that the dGEMRIC technique is able to monitor cartilage repair following regenerative cartilage treatment. DESIGN: Thirty-one patients with a focal cartilage lesion underwent a dGEMRIC scan prior to cartilage repair surgery and at 3 and 12 months follow-up. At similar time points clinical improvement was monitored using the Knee injury and Osteoarthritis Outcome Score (KOOS) and Lysholm questionnaires. Per MRI scan several regions-of-interest (ROIs) were defined for different locations in the joint. The dGEMRIC index (T1gd) was calculated for each ROI. Repeated-measures analysis of variance (RMANOVA) analysis was used to evaluate improvement in clinical scores and MRI T1gd over time. Also regression analysis was performed to show the influence of local repair on cartilage quality at distant locations in the knee. RESULTS: Clinical scores and the dGEMRIC T1gd per ROI showed a statistically significant improvement (P < 0.01), from baseline, at 12 months follow-up. Also, improvement from baseline in T1gd of the ROI defining the treated cartilage defect showed a direct relationship (P < 0.007) to the improvement of the T1gd of ROI at other locations in the joint. CONCLUSIONS: The dGEMRIC MRI protocol is a useful method to evaluate cartilage repair. In addition, local cartilage repair influenced the cartilage quality at other location in the joint. These findings validate the use of dGEMRIC for non-invasive evaluation of the effects of cartilage regeneration.


Asunto(s)
Cartílago Articular/fisiología , Aumento de la Imagen/métodos , Articulación de la Rodilla/fisiología , Imagen por Resonancia Magnética/métodos , Regeneración/fisiología , Adulto , Artroscopía , Cartílago Articular/lesiones , Cartílago Articular/cirugía , Medios de Contraste , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Gadolinio DTPA , Glicosaminoglicanos/metabolismo , Humanos , Traumatismos de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Encuestas y Cuestionarios , Resultado del Tratamiento
7.
Eur J Vasc Endovasc Surg ; 45(4): 340-50, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23403221

RESUMEN

OBJECTIVES: The purpose of this systematic review was to examine whether magnetic resonance imaging (MRI) or computed tomography angiography (CTA) is more sensitive for the detection of endoleaks in patients with abdominal aortic aneurysm (AAA) after EVAR. DESIGN: Systematic review. MATERIALS AND METHODS: A systematic electronic search was performed. Articles were included when post-EVAR patients were evaluated by both MRI as index test and CTA as comparison. Methodological quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. Primary outcome was the proportion of patients in whom MRI detected additional endoleaks, which were not seen with CTA. RESULTS: Eleven articles were included. The overall methodological quality of the articles was good. In total, 369 patients with 562 MRI and 562 CTA examinations were included. A total of 146 endoleaks were detected by CTA; MRI detected all but two of these endoleaks. With MRI 132 additional endoleaks were found. CONCLUSIONS: MRI is more sensitive compared to CTA for the detection of post-EVAR endoleaks, especially for the detection of type II endoleaks. MRI should be considered in patients with continued AAA growth and negative or uncertain findings at CTA.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/diagnóstico , Procedimientos Endovasculares/efectos adversos , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/patología , Humanos , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Resultado del Tratamiento
8.
Cancer Imaging ; 12: 387-94, 2012 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-23022541

RESUMEN

Recent decades have seen a paradigm shift in the treatment of liver tumours from invasive surgical procedures to minimally invasive image-guided ablation techniques. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a novel, completely non-invasive ablation technique that has the potential to change the field of liver tumour ablation. The image guidance, using MR imaging and MR temperature mapping, provides excellent planning images and real-time temperature information during the ablation procedure. However, before clinical implementation of MR-HIFU for liver tumour ablation is feasible, several organ-specific challenges have to be addressed. In this review we discuss the MR-HIFU ablation technique, the liver-specific challenges for MR-HIFU tumour ablation, and the proposed solutions for clinical translation.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Neoplasias Hepáticas/terapia , Imagen por Resonancia Magnética , Humanos
9.
Osteoarthritis Cartilage ; 20(10): 1134-41, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22796509

RESUMEN

OBJECTIVE: The high tibial osteotomy (HTO) is an effective strategy for treatment of painful medial compartment knee osteoarthritis. Effects on cartilage quality are largely unknown. Delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) enables non-invasive assessment of cartilage glycosaminoglycan content. This study aimed to evaluate if dGEMRIC could detect relevant changes in cartilage glycosaminoglycan content following HTO. DESIGN: Ten patients with medial compartment osteoarthritis underwent a dGEMRIC scan prior to HTO, and after bone healing and subsequent hardware removal. A dGEMRIC index (T1Gd) was used for changes in cartilage glycosaminoglycan content, a high T1Gd indicating a high glycosaminoglycan content and vice versa. Radiographic analysis included mechanical axis and tibial slope measurement. clinical scores [knee osteoarthritis outcome scale (KOOS), visual analogue score (VAS) for pain, Knee Society clinical rating system (KSCRS)] before, 3 and 6 months after HTO and after hardware removal were correlated to T1Gd changes. RESULTS: Overall a trend towards a decreased T1Gd, despite HTO, was observed. Before and after HTO, lateral femoral condyle T1Gd was higher than medial femoral condyle (MFC) T1Gd and tibial cartilage T1Gd was higher than that of femoral cartilage (P < 0.001). The MFC had the lowest T1Gd before and after HTO. Clinical scores all improved significantly (P < 0.01), KOOS Symptoms and QOL were moderately related to changes in MFC T1Gd. CONCLUSIONS: dGEMRIC effectively detected differences in cartilage quality within knee compartments before and after HTO, but no changes due to HTO were detected. Hardware removal post-HTO seems essential for adequate T(1)Gd interpretation. T(1)Gd was correlated to improved clinical scores on a subscore level only. Longer follow-up after HTO may reveal lasting changes. ClinicalTrials.gov registration ID: NCT01269944.


Asunto(s)
Cartílago Articular/patología , Medios de Contraste , Gadolinio , Imagen por Resonancia Magnética/métodos , Osteotomía/métodos , Complicaciones Posoperatorias/diagnóstico , Adulto , Biomarcadores/metabolismo , Cartílago Articular/metabolismo , Cartílago Articular/cirugía , Estudios de Factibilidad , Femenino , Glicosaminoglicanos/metabolismo , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Articulación de la Rodilla/patología , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/patología , Osteoartritis de la Rodilla/cirugía , Osteotomía/efectos adversos , Complicaciones Posoperatorias/etiología , Pronóstico , Rango del Movimiento Articular , Reproducibilidad de los Resultados , Tibia/cirugía
10.
Eur Radiol ; 22(2): 411-7, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21901565

RESUMEN

OBJECTIVE: The purpose of this prospective multicenter study was to assess the safety and technical feasibility of volumetric Magnetic Resonance-guided High Intensity Focused Ultrasound (MR-HIFU) ablation for treatment of patients with symptomatic uterine fibroids. METHODS: Thirty-three patients with 36 fibroids were treated with volumetric MR-HIFU ablation. Treatment capability and technical feasibility were assessed by comparison of the Non-Perfused Volumes (NPVs) with MR thermal dose predicted treatment volumes. Safety was determined by evaluation of complications or adverse events and unintended lesions. Secondary endpoints were pain and discomfort scores, recovery time and length of hospital stay. RESULTS: The mean NPV calculated as a percentage of the total fibroid volume was 21.7%. Correlation between the predicted treatment volumes and NPVs was found to be very strong, with a correlation coefficient r of 0.87. All patients tolerated the treatment well and were treated on an outpatient basis. No serious adverse events were reported and recovery time to normal activities was 2.3 ± 1.8 days. CONCLUSION: This prospective multicenter study proved that volumetric MR-HIFU is safe and technically feasible for the treatment of symptomatic uterine fibroids. KEY POINTS: • Magnetic-resonance-guided high intensity focused ultrasound allows non-invasive treatment of uterine fibroids. • Volumetric feedback ablation is a novel technology that allows larger treatment volumes • MR-guided ultrasound ablation of uterine fibroids appears safe using volumetric feedback.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Leiomioma/diagnóstico por imagen , Leiomioma/patología , Leiomioma/terapia , Imagen por Resonancia Magnética Intervencional/métodos , Imagen por Resonancia Magnética/métodos , Terapia por Ultrasonido/métodos , Neoplasias Uterinas/diagnóstico por imagen , Neoplasias Uterinas/patología , Neoplasias Uterinas/terapia , Adolescente , Adulto , Diseño de Equipo , Europa (Continente) , Femenino , Humanos , Tiempo de Internación , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Ultrasonido , Ultrasonografía
11.
Osteoarthritis Cartilage ; 19(11): 1343-8, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21884807

RESUMEN

OBJECTIVE: For the radiographic evaluation of subchondral bone changes (sclerosis) in osteoarthritis (OA), bone density (BD) is commonly subjectively assessed. BD evaluation using plain digital radiography might be influenced by acquisition and post-processing (PP) settings. Objective of this study was to evaluate the effects of these settings on the measurement of BD using digital radiographs. METHODS: A bone density standard (BDS) of hydroxyapatite (HA) mimicked a BD range of 1.0-5.75 g/cm(2). Digital radiographs were acquired with variation in acquisition settings, and with clinical and minimal PP. An aluminum step wedge served as an internal reference to express the gray values of the BDS in mm aluminum equivalents (mmAl). The relation (R(2)) between actual BD and BD normalized to the reference wedge was evaluated with linear regression analyses for radiographs with variations in PP and acquisition settings. Precision of BD measurement of the BDS was evaluated for application in clinical practice. RESULTS: The correlation between actual BD and BD normalized to the reference was improved by changing PP from clinical (R(2)=0.96) to minimal (R(2)=0.98). Higher tube voltage [kilovolt (kV)] improved the correlation further. Even for clinical PP, average standard deviation (SD) was 0.97 mmAl, much smaller than the change of 2.51 mmAl clinically observed in early OA, which implies the feasibility of BD measurements on digital radiographs. CONCLUSION: Changing PP and acquisition settings in clinical practice can have profound effect on outcome. If done with care, accurate BD measurement is feasible using plain digital radiography.


Asunto(s)
Materiales Biocompatibles , Densidad Ósea/fisiología , Durapatita , Intensificación de Imagen Radiográfica/métodos , Absorciometría de Fotón , Humanos , Articulación de la Rodilla/diagnóstico por imagen , Modelos Biológicos , Intensificación de Imagen Radiográfica/normas , Reproducibilidad de los Resultados
12.
Clin Orthop Relat Res ; 469(6): 1743-9, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21318629

RESUMEN

BACKGROUND: Radiographic diagnosis and followup studies of developmental dysplasia of the hip are commonly performed by measuring the acetabular index on radiographs using Hilgenreiner's method. The outcome of the measurement, however, depends on the orientation of the subject's pelvis relative to the xray source. The influence of pelvic rotation and tilt on the measurement error has been evaluated separately but not in combination. QUESTIONS/PURPOSES: We asked whether (1) combinations of pelvic rotation and tilt introduced systematic error in acetabular index measurement in a reproducible way, and (2) ratios proposed to evaluate either pelvic rotation (R(rotation)) or pelvic tilt (R(tilt)) are influenced by pelvic tilt and rotation, respectively. METHODS: Radiographic measurements of the acetabular index, R(rotation), and R(tilt) were performed on digitally reconstructed radiographs of one high-resolution three-dimensional CT dataset with various combinations of pelvic rotation and tilt. RESULTS: For rotations and tilt up to 12°, the average systematic errors in the acetabular index varied from -8.8° to 4.5°. Negative and positive error values can be interpreted as underestimations and overestimations of the acetabular index, respectively. Errors in acetabular index measurements were acceptable for R(rotation) values between 1.0 and 2.0 and R(tilt) values between 1.1 and 1.8. CONCLUSIONS: To limit the systematic error in assessing the acetabular index caused by pelvic misalignment, we recommend only radiographs acquired with ± 4° rotation and ± 4° tilt be considered acceptable.


Asunto(s)
Errores Diagnósticos , Luxación Congénita de la Cadera/diagnóstico por imagen , Cadera/diagnóstico por imagen , Huesos Pélvicos/diagnóstico por imagen , Intensificación de Imagen Radiográfica , Tomografía Computarizada por Rayos X/métodos , Acetábulo/diagnóstico por imagen , Niño , Humanos , Rotación
13.
Phys Med Biol ; 56(4): 1031-43, 2011 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-21258138

RESUMEN

Spatial and soft tissue information provided by magnetic resonance imaging can be very valuable during image-guided procedures, where usually only real-time two-dimensional (2D) x-ray images are available. Registration of 2D x-ray images to three-dimensional (3D) magnetic resonance imaging (MRI) data, acquired prior to the procedure, can provide optimal information to guide the procedure. However, registering x-ray images to MRI data is not a trivial task because of their fundamental difference in tissue contrast. This paper presents a technique that generates pseudo-computed tomography (CT) data from multi-spectral MRI acquisitions which is sufficiently similar to real CT data to enable registration of x-ray to MRI with comparable accuracy as registration of x-ray to CT. The method is based on a k-nearest-neighbors (kNN)-regression strategy which labels voxels of MRI data with CT Hounsfield Units. The regression method uses multi-spectral MRI intensities and intensity gradients as features to discriminate between various tissue types. The efficacy of using pseudo-CT data for registration of x-ray to MRI was tested on ex vivo animal data. 2D-3D registration experiments using CT and pseudo-CT data of multiple subjects were performed with a commonly used 2D-3D registration algorithm. On average, the median target registration error for registration of two x-ray images to MRI data was approximately 1 mm larger than for x-ray to CT registration. The authors have shown that pseudo-CT data generated from multi-spectral MRI facilitate registration of MRI to x-ray images. From the experiments it could be concluded that the accuracy achieved was comparable to that of registering x-ray images to CT data.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Animales , Estudios de Factibilidad , Humanos
14.
Med Phys ; 37(4): 1884-92, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20443510

RESUMEN

PURPOSE: The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a successful registration. Previously reported capture ranges, defined as the 95% success range, are in the order of 4-11 mm mean target registration error. In this article, a relatively computationally inexpensive and robust estimation method is proposed with the objective to enlarge the capture range. METHODS: The method uses the projection-slice theorem in combination with phase correlation in order to estimate the transform parameters, which provides an initialization of the subsequent registration procedure. RESULTS: The feasibility of the method was evaluated by experiments using digitally reconstructed radiographs generated from in vivo 3D-RX data. With these experiments it was shown that the projection-slice theorem provides successful estimates of the rotational transform parameters for perspective projections and in case of translational offsets. The method was further tested on ex vivo ovine x-ray data. In 95% of the cases, the method yielded successful estimates for initial mean target registration errors up to 19.5 mm. Finally, the method was evaluated as an initialization method for an intensity-based 2D-3D registration method. The uninitialized and initialized registration experiments had success rates of 28.8% and 68.6%, respectively. CONCLUSIONS: The authors have shown that the initialization method based on the projection-slice theorem and phase correlation yields adequate initializations for existing registration methods, thereby substantially enlarging the capture range of these methods.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Algoritmos , Animales , Área Bajo la Curva , Perros , Diseño de Equipo , Análisis de Fourier , Humanos , Imagen por Resonancia Magnética/métodos , Modelos Estadísticos , Distribución Normal , Radiografía/métodos , Reproducibilidad de los Resultados , Rayos X
15.
Eur J Vasc Endovasc Surg ; 39(2): 193-9, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19879781

RESUMEN

OBJECTIVE: Dynamic imaging provides insight into aortic shape changes throughout the cardiac cycle. These changes may be important for proximal aortic stent graft fixation, sealing and durability. The objective of this study is to analyse the influence of different types of stent grafts on dynamic changes of the aneurysm neck. METHODS: Pre- and postoperative electrocardiography (ECG)-gated computed tomographic angiography (CTA) scans were obtained in 30 abdominal aortic aneurysm (AAA) patients, 10 each from three different types of stent grafts (10 Talent, Endurant, and Excluder). Each dynamic CTA dataset consisted of eight reconstructed images over the cardiac cycle. Aortic area and radius changes during the cardiac cycle were determined at two levels: (A) 3 cm above and (B) 1 cm below the lowermost renal artery. Radius changes were measured over 360 axes, and plotted in a polar plot. An ellipse was fitted over the plots to determine radius changes over the major and minor axis for assessment of the asymmetric aspect and most prominent direction of distension. RESULTS: Baseline characteristics did not differ significantly between the three groups. Preoperatively, the aortic area increased significantly (p < 0.001) over the cardiac cycle in all patients at both levels: (A) mean increase 8.3 +/- 4.1% (2.0-17.3%); (B) mean increase 5.9 +/- 4.2% (1.9-12.4%). The postoperative aortic area increase over the cardiac cycle did not differ significantly from preoperative increases: (A) mean increase 9.9 +/- 2.2% (4.4-20.0%); (B) mean increase 7.7 +/- 2.4% (3.8-12.4%). The difference between radius change over the major and minor axis was significant both pre- and postoperatively for all three stent grafts, indicating asymmetric distension. Suprarenal, the distension showed a tendency to right-anterior and infrarenal to left-anterior. The distension and direction of the aortic expansion was preserved after stent grafting. There were no differences between the three types of stent grafts regarding their impact on the aortic distension or direction of this distension. CONCLUSION: The aorta expands significantly and asymmetrically throughout the cardiac cycle. After implantation of abdominal aortic stent grafts, the aortic distension and direction of distension remain equally preserved in all three groups. The three stent graft types studied seem to be able to adapt to the asymmetric dynamic aortic shape changes.


Asunto(s)
Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Prótesis Vascular , Stents , Tomografía Computarizada Espiral/métodos , Anciano , Anciano de 80 o más Años , Algoritmos , Aneurisma de la Aorta Abdominal/patología , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Flujo Pulsátil , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Resultado del Tratamiento
16.
Eur J Vasc Endovasc Surg ; 37(2): 168-74, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19046649

RESUMEN

OBJECTIVE: Knowledge of aortic shape changes throughout the cardiac cycle can offer improved understanding of vascular pathophysiology and may have crucial impact on stentgraft design and EVAR durability. To understand underlying mechanisms of dynamic changes in aortic aneurysm (neck) morphology, the undiseased aorta has to be studied first. Objective is to visualize and characterize dynamic aortic shape changes in young healthy volunteers. MATERIALS AND METHODS: Fifteen healthy volunteers (7 male, median age 24 year, range 18-28) were scanned using ECG-gated balanced gradient-echo MRI, with 16 reconstructed cardiac phases. Transverse scans were made perpendicular to the aorta: (A) above the aortic bifurcation, (B) infrarenal, (C) juxtarenal, (D) suprarenal and (E) above the celiac trunk. After aortic lumen segmentation, radial changes during the cardiac cycle were measured, from the center of mass, over 360 degrees, and plotted. An ellipse was fitted over the distention plots, yielding the direction (AP:0 degrees, Right: -90 degrees, Left: 90 degrees ) and magnitude of radius change over the major and minor axis. RESULTS: Asymmetric distention was observed, with a variable rate per patient and level. Radius changes decreased from the proximal to distal aorta. Radius changes over the major axis ranged from 14% to 41%. At level A mean change in radius over the minor versus major axis was 1.4+/-0.2mm (17%) versus 1.6+/-0.2mm (20%), respectively. At B 1.7+/-0.4mm (22%) versus 2.0+/-0.4mm (25%), at C 1.7+/-0.4mm (22%) versus 2.2+/-0.4mm (27%) at D 2.0+/-0.4mm (25%) versus 2.4+/-0.5mm (30%) and at E 2.2+/-0.3mm (27%) versus 2.6+/-0.3mm (32%). Mean orientation of the major axis was (A) 0.8+/-23.3 degrees , (B) 1.8+/-31.3 degrees , (C) 14.0+/-15.5 degrees , (D) -28.8+/-48.0 degrees and (E) 18.4+/-22.2 degrees. CONCLUSIONS: Aortic pulsatile distention in young healthy volunteers is asymmetric, with up to 41% radius change in the descending aorta. This study offers a frame of reference for dynamic imaging studies in patients with aortic pathology and provides a valuable non-invasive tool for future research into aortic distention, development and localization of vascular pathology.


Asunto(s)
Aorta/anatomía & histología , Aorta/fisiología , Electrocardiografía , Imagen por Resonancia Magnética , Flujo Pulsátil , Adolescente , Adulto , Adaptabilidad , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Valores de Referencia , Factores de Tiempo , Adulto Joven
17.
Osteoarthritis Cartilage ; 16(2): 234-43, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17693099

RESUMEN

OBJECTIVE: Radiography is still the golden standard for imaging features of osteoarthritis (OA), such as joint space narrowing, subchondral sclerosis, and osteophyte formation. Objective assessment, however, remains difficult. The goal of the present study was to evaluate a novel digital method to analyse standard knee radiographs. METHODS: Standardized radiographs of 20 healthy and 55 OA knees were taken in general practise according to the semi-flexed method by Buckland-Wright. Joint Space Width (JSW), osteophyte area, subchondral bone density, joint angle, and tibial eminence height were measured as continuous variables using newly developed Knee Images Digital Analysis (KIDA) software on a standard PC. Two observers evaluated the radiographs twice, each on two different occasions. The observers were blinded to the source of the radiographs and to their previous measurements. Statistical analysis to compare measurements within and between observers was performed according to Bland and Altman. Correlations between KIDA data and Kellgren & Lawrence (K&L) grade were calculated and data of healthy knees were compared to those of OA knees. RESULTS: Intra- and inter-observer variations for measurement of JSW, subchondral bone density, osteophytes, tibial eminence, and joint angle were small. Significant correlations were found between KIDA parameters and K&L grade. Furthermore, significant differences were found between healthy and OA knees. CONCLUSION: In addition to JSW measurement, objective evaluation of osteophyte formation and subchondral bone density is possible on standard radiographs. The measured differences between OA and healthy individuals suggest that KIDA allows detection of changes in time, although sensitivity to change has to be demonstrated in long-term follow-up studies.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Articulación de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Densidad Ósea , Femenino , Fémur/diagnóstico por imagen , Humanos , Articulación de la Rodilla/patología , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Osteoartritis de la Rodilla/patología , Osteofito/diagnóstico por imagen , Radiografía , Tibia/diagnóstico por imagen
18.
Eur J Vasc Endovasc Surg ; 32(5): 532-6, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16798028

RESUMEN

OBJECTIVE: Thoracic aneurysm preoperative imaging is performed using static techniques without consideration of normal aortic dynamics. Improved understanding of the native aortic environment into which thoracic endografts are placed may aid in device selection. It is unclear what comprises normal thoracic aortic pulsatility. We studied these phenomena dynamically using ECG-gated 64-slice CTA. METHODS: Maximum diameter and area change per cardiac cycle was measured at surgically relevant anatomic thoracic landmarks in ten patients; 1.0 cm proximal and distal to the subclavian artery, 3.0 cm distal to the subclavian artery, and 3.0 cm proximal to the celiac trunk. Data was acquired using a novel ECG-gated dynamic 64-slice CT scanner during a single breath hold with a standard radiation dose and contrast load. Eight gated data sets, covering the cardiac cycle were reconstructed, perpendicular to the central lumen. RESULTS: There is impressive change in both maximum diameter and area in the thoracic aorta during the cardiac cycle. Mean maximum diameter changes of greater than 10% are observed in the typical sealing zones of commercially available endografts corresponding to diameter increases of up to 5mm. Aortic area increases by over 5% per cardiac cycle. CONCLUSIONS: ECG-gated dynamic CTA with standard radiation dose is feasible on a 64-slice scanner and provides insight into (patho) physiology of thoracic aortic conformational changes. Clinicians typically oversize thoracic endografts by 10%. With aortic pulsatility resulting in diameter changes of up to 17.8%, the potential exists for endograft undersizing, graft migration, intermittent type I endoleak, and poor patient outcome. Furthermore, aortic pulsatility is not evenly distributed, and non-circular stentgraft designs should be considered in the future since aortic distension in the aneurysm neck is not evenly distributed.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Cineangiografía , Tomografía Computarizada por Rayos X , Angioplastia , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Implantación de Prótesis Vascular , Adaptabilidad , Electrocardiografía , Estudios de Factibilidad , Humanos , Interpretación de Imagen Asistida por Computador , Variaciones Dependientes del Observador , Selección de Paciente , Diseño de Prótesis , Flujo Pulsátil , Valores de Referencia , Reproducibilidad de los Resultados
19.
Eur J Vasc Endovasc Surg ; 32(4): 361-5, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16630731

RESUMEN

AIM: The aim of study was to compare the sensitivity of MRI and CTA for endoleak detection and classification after EVAR. PATIENTS & METHODS: Twenty-eight patients, between 2 days and 65 months after EVAR, were evaluated with both CT and MRI. Twenty-five patients had an Ancure graft and the other three had an Excluder. The MRI protocol for endoleak evaluation included: a T1-weighted spin echo, a high-resolution 3D CE-MRA, and a post-contrast T1-weighted spin echo. In total 40 ml Gadolinium was administered. The CT protocol consisted of a blank survey followed by a spiral CT angiography (CTA) using 140 ml of Ultravist. An experienced, blinded observer evaluated all CTs and MRIs. RESULTS: Using MRI and MRA techniques significantly more endoleaks (23/35) were detected than with CTA (11/35) (p=0.01, Chi-Square). CT could not determine the type of endoleak in 3 of the 11 endoleaks detected and was uncertain in one. MRI was uncertain about the type in 14 of the 23 endoleaks detected. All endoleaks visible on CT were visible by MRI as well. CONCLUSIONS: MRI techniques are more sensitive for the detection of endoleak after endovascular AAA repair than CT.


Asunto(s)
Angioplastia , Aneurisma de la Aorta Abdominal/cirugía , Imagen por Resonancia Magnética , Complicaciones Posoperatorias/diagnóstico , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
20.
Phys Med Biol ; 51(6): N127-37, 2006 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-16510948

RESUMEN

Susceptibility markers for passive tracking need to be small in order to maintain the shape and mechanical properties of the endovascular device. Nevertheless, they also must have a high magnetic moment to induce an adequate artefact at a variety of scan techniques, tracking speeds and, preferably, field strengths. Paramagnetic markers do not satisfy all of these requirements. Ferro- and ferrimagnetic materials were therefore investigated with a vibrating sample magnetometer and compared with the strongly paramagnetic dysprosium oxide. Results indicated that the magnetic behaviour of stainless steel type AISI 410 corresponds the best with ideal marker properties. Markers with different magnetic moments were constructed and tested in in vitro and in vivo experiments. The appearance of the corresponding artefacts was field strength independent above magnetic saturation of 1.5 T. Generally, the contrast-to-noise ratio decreased at increasing tracking speed and decreasing magnetic moment. Device depiction was most consistent at a frame rate of 20 frames per second.


Asunto(s)
Angiografía/instrumentación , Magnetismo , Angiografía/métodos , Animales , Biomarcadores , Cateterismo/instrumentación , Disprosio/química , Óxido Ferrosoférrico/química , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética/métodos , Modelos Estadísticos , Níquel , Aceleradores de Partículas , Acero Inoxidable , Porcinos , Termodinámica , Factores de Tiempo , Zinc/química