Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Radiat Prot Dosimetry ; 199(14): 1591-1599, 2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37721086

RESUMEN

This work presents the computational analysis of the sensitivity improvements that could be achieved in lithium formate monohydrate (LFM) electron paramagnetic resonance (EPR) dosemeters exposed to neutron beams. Monte Carlo (MC) simulations were performed on LFM pellets exposed to neutron beams with different energy spectra at various depths inside a water phantom. Various computations were carried out by considering different enrichments of 6Li inside the LFM matrix as well as addition of different amounts of gadolinium oxide inside the pellet blend. The energy released per unit mass was calculated with the aim of predicting the increase in dose achievable by the addition of sensitizers inside the pellets. As expected, a larger amount of 6Li induces an increase of energy released because of the charged secondary particles (i.e. 3H ions and α-particles) produced after neutron capture. For small depths in water phantom and low-energy neutron spectra the dose increase due to 6Li enrichment is high (more than three orders of magnitude with respect to the case of with 7Li). In case of epithermal neutron beams the energy released in 6Li-enriched LFM compound is smaller but larger than in the case of fast neutron beams. On the other hand, the computational analysis evidenced that gadolinium is less effective than 6Li in improving neutron sensitivity of the LFM pellets. Discussion based on the features of MC transport code is provided. This result suggests that 6Li enrichment of LFM dosemeters would be more effective for neutron sensitivity improvement and these EPR dosemeters could be tested for dosimetric applications in Neutron Capture Therapy.


Asunto(s)
Neutrones Rápidos , Neutrones , Espectroscopía de Resonancia por Spin del Electrón , Agua
2.
Ital J Food Saf ; 10(1): 8914, 2021 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-33907684

RESUMEN

This study shows the frequency of seeds samples contaminated by Salmonella spp. collected randomly from local markets; on 30 black pepper sample no contaminated sample was found while Salmonella spp. was detected in 3 of 36 (8.3%) analyzed sesame samples; three different serotypes were identified: S. Montevideo, S. Stanleyville e S. Tilene. The efficacy of gamma irradiation to inactivate Salmonella Montevideo in black pepper and sesame irradiated between 1 and 5 kGy was evaluated. 3 kGy is sufficient to reduce of 3-4 log CFU/g; whereas 5 kGy have been need to reduce 5.5-6 log CFU/g for samples of black pepper and sesame. No statistically significant differences were found between black pepper and sesame.

3.
Food Chem ; 297: 124898, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31253334

RESUMEN

Anthocyanins and anthocyanidins are polyphenolic compounds, responsible for the red and blue colours in several fruits, flowers, and leaves. Their colorant properties, bioavailability and antioxidant activity, made anthocyanins and anthocyanidins largely adopted in food and pharmaceutical industries. In this body of work, we firstly introduced structure, photophysical properties, co-pigmentation, antioxidant properties, glycosylation and complexation of anthocyanins and anthocyanidins. Secondly, we reported the computational methods adopted and the main theoretical results involving either anthocyanins and anthocyanidins, ranging from the first theoretical investigation on the structure of flavylium ions to the most recent studies on anthocyanins adsorbed on TiO2. We reviewed the computational contributions to the description of molecular properties of anthocyanins and anthocyanidins, giving a particular attention to the geometries, the spectroscopic features and the complexation properties of such molecules. Nowadays, theoretical calculations represent an essential methodology to understand and predict the chemical and physical properties of anthocyanins and their derivates.


Asunto(s)
Antocianinas/química , Antioxidantes/química , Adsorción , Antocianinas/análisis , Glicosilación , Pigmentación , Teoría Cuántica , Energía Solar
4.
Radiat Environ Biophys ; 56(4): 471-480, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28929295

RESUMEN

This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076®) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose-response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the manufactured dosimeters was obtained. The ESR signal proved to increase linearly with increasing dose in the investigated dose range 1-13 Gy. The presence of an intrinsic background signal limits the minimum detectable dose to a value of approximately 0.6 Gy. Reliable and accurate assessment of the dose was achieved, independently of the dose rate. Such characteristics, together with the fact that IRGANOX 1076® is almost tissue-equivalent, and the stability of the ESR signal, make these dosimeters promising materials for ESR dosimetric applications in radiotherapy.


Asunto(s)
Fenoles/química , Fotones/uso terapéutico , Radiometría/métodos , Espectroscopía de Resonancia por Spin del Electrón , Microondas , Modelos Moleculares , Conformación Molecular , Dosificación Radioterapéutica
5.
Radiat Res ; 169(2): 232-9, 2008 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-18220469

RESUMEN

Many efforts have been made to develop neutron capture therapy (NCT) for cancer treatment. Among the challenges in using NCT is the characterization of the features of the mixed radiation field and of its components. In this study, we examined the enhancement of the ESR response of pellets of alanine and ammonium tartrate with gadolinium oxide exposed to a thermal neutron beam. In particular, the ESR response of these dosimeters as a function of the gadolinium content inside the dosimeter was analyzed. We found that the addition of gadolinium improves the sensitivity of both alanine and ammonium tartrate. However, the use of gadolinium reduces or abolishes tissue equivalence because of its high atomic number (Z(Gd) = 64). Therefore, it is necessary to find the optimum compromise between the sensitivity to thermal neutrons and the reduction of tissue equivalence. Our analysis showed that a low concentration of gadolinium oxide (of the order of 5% of the total mass of the dosimeter) can enhance the thermal neutron sensitivity more than 13 times with an insignificant reduction of tissue equivalence.


Asunto(s)
Alanina/efectos de la radiación , Espectroscopía de Resonancia por Spin del Electrón/métodos , Gadolinio/efectos de la radiación , Neutrones , Radiometría/métodos , Tartratos/efectos de la radiación , Alanina/química , Relación Dosis-Respuesta en la Radiación , Gadolinio/química , Calor , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tartratos/química
6.
Radiat Res ; 166(5): 802-9, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17067208

RESUMEN

In this paper we present an investigation of the electron spin resonance (ESR) line shape of ammonium tartrate (AT) dosimeters exposed to radiation with different linear energy transfer (LET). We exposed our dosimeters to gamma-ray photons ((60)Co), 7 MeV and 14 MeV initial energy electrons, and 19.3 MeV initial energy protons. The differences in the power saturation behavior of ESR spectra of AT irradiated with photons, electrons and protons could be correlated to the effective LET of the radiation beams. We analyzed the behavior of peak-to-peak amplitude as a function of microwave power, and we developed a fitting procedure that permits us to obtain the dependence of the homogeneity parameter of the line shape on the LET of the radiation using the Castner saturation theory. This simple procedure allows us to distinguish the LET of the radiation beam.


Asunto(s)
Algoritmos , Radioisótopos de Cobalto/análisis , Espectroscopía de Resonancia por Spin del Electrón/métodos , Transferencia Lineal de Energía , Radiometría/métodos , Tartratos/química , Tartratos/efectos de la radiación , Relación Dosis-Respuesta en la Radiación , Electrones , Rayos gamma , Fotones , Protones , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...