Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Oper Dent ; 47(6): 670-677, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36279319

RESUMEN

OBJECTIVE: To investigate the efficacy of three specially designed polishing kits for provisional restorations made from three chairside computer-aided design and computer-aided manufacturing (CAD/CAM) provisional resin blocks. METHOD: Ninety-six chairside CAD/CAM provisional restorations were milled out of three chairside CAD/CAM provisional resin blocks: (1) ArtBloc Temp (Merz Dental); (2) Telio CAD (Ivoclar Vivadent); and (3) Vita CAD-Temp (VITA Zahnfabrik). The provisional restorations for each material were allocated into the following groups: (1) milled restorations (no polish); (2) polished with CADMaster CAD/CAM Adjustment & Polishing Kit (CM, Shofu); (3) polished with KUT Ultimate Bisacryl (Temporaries) Polishing Kit (KU, Dental Savings Club); and (4) polished with K0330 PMMA Adjusting, Finishing & Polishing (KP, Brasseler USA). Optical profilometry and atomic force microscopy (AFM) were used to assess the surface roughness (Ra) of each provisional restoration at the microscale and nanoscale, respectively, and obtain topographical images. In addition, the milled and polished restorations were visually evaluated by 16 dentists. RESULTS: There was a strong positive correlation with Ra values between optical profilometry and AFM. Only KP significantly improved the surface roughness of CAD/CAM provisional restorations compared to the milled equivalent, regardless of material type or measurement modality (ie, lateral length scale). Although surface topography imaging with AFM revealed some shallow scratches, even for KP polished specimens, all KP polished restorations were categorized as clinically acceptable for provisional restorations in visual inspections from dentists. CONCLUSION: Specially designed polishing kits for provisional restorations did not all improve the surface roughness of chairside CAD/CAM provisional restorations, regardless of the measurement method. KP was more consistently effective in polishing milled chairside CAD/CAM provisional restorations than CM and KU.


Asunto(s)
Pulido Dental , Porcelana Dental , Pulido Dental/métodos , Cerámica , Propiedades de Superficie , Materiales Dentales , Diseño Asistido por Computadora , Ensayo de Materiales
2.
Oper Dent ; 46(2): 219-225, 2021 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-34192321

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate the effectiveness of five different polishing systems on a computer-aided design and computer-aided manufacturing (CAD/CAM) polymer-infiltrated ceramic-network restoration with nanoscale assessment using atomic force microscopy (AFM) and visual assessment performed by dental school senior students and faculty members. METHOD: Forty-eight full coverage crowns were milled out of polymer-infiltrated ceramic-network CAD/CAM blocks (Vita Enamic) for polishing with one company proprietary, two ceramic and two composite polishing systems. The prepared crowns were divided into six groups: (1) no polishing (control); (2) polishing with Vita Enamic Polishing Kit (VEna); (3) polishing with Shofu Porcelain Laminate Polishing Kit (SCer); (4) polishing with Brasseler Dialite Feather lite All-Ceramic Adjusting & Polishing System (BCer); (5) polishing with Shofu Composite Polishing Kit (SCom); and (6) polishing with Brasseler Composite Polishing Kit (BCom). The polished crown surface topography was observed, and surface roughness and area were measured with AFM. In addition, polished crowns were visually assessed by 15 senior dental students and 15 dental school faculty members. RESULTS: All polishing treatments significantly reduced the surface roughness and area of the crown compared with the control. SCom and BCom showed significantly higher surface area than VEna, and the SCer and BCer groups were intermediate, showing no significant difference from either VEna or SCom and BCom. There were no significant differences in surface roughness between any of the systems. Dental students and faculty members classified the groups polished with VEna, SCer, and BCer groups as clinically acceptable, and they selected BCer group as the best polished restorations and the control group as the least polished restorations. CONCLUSIONS: Ceramic and composite polishing systems produced similar polishing results as that observed using a company proprietary polishing system. However, effectiveness for polishing using a company proprietary and ceramic polishing system tends to be higher than composite polishing systems.


Asunto(s)
Cerámica , Polímeros , Diseño Asistido por Computadora , Pulido Dental , Porcelana Dental , Humanos , Ensayo de Materiales , Propiedades de Superficie
3.
Oper Dent ; 45(1): 80-91, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31226005

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate whether different enamel etching methods with reduced etching times would improve the bonding effectiveness of universal adhesives. METHODS AND MATERIALS: Three enamel etching methods, phosphoric acid ester monomer (PPM) etching, phosphoric acid (PPA) etching, and polyalkenoic acid (PLA) etching, and three universal adhesives, G-Premio Bond (GP), Prime&Bond elect (PE), and Scotchbond Universal Adhesive (SU), were evaluated. Initial bond strengths and fatigue strengths of universal adhesives to ground enamel and ground enamel etched for less than one, five, 10, and 15 seconds using different etching methods were determined. The bonded fatigue specimens were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred with a staircase method. Atomic force micrograph (AFM) observations along with measurements of surface Ra roughness and modified surface area of enamel with different etching protocols were also conducted. RESULTS: The bond fatigue durability of universal adhesives to enamel with PPA etching from less than one to 15 seconds and PLA etching for 15 seconds was significantly higher than that to ground enamel. The bond fatigue durability to enamel with PPM etching was not increased compared with ground enamel. The surface Ra roughness and surface area obtained with AFM of enamel increased after PPA and PLA etching, and those values were significantly higher than those of ground enamel. Furthermore, surface Ra roughness and surface area with PPA etching were significantly higher than those with PLA etching. However, surface Ra roughness and surface area of enamel with PPM etching were similar to those of ground enamel regardless of etching time. CONCLUSION: PPA etching for less than one to 15 seconds and PLA etching for 15 seconds improve universal adhesive bonding, surface Ra roughness, and surface area of enamel. However, PPM etching is not effective, regardless of etching time, in improving bonds strengths, increasing surface roughness, and increasing surface area.


Asunto(s)
Grabado Ácido Dental , Recubrimiento Dental Adhesivo , Cementos Dentales , Esmalte Dental , Ensayo de Materiales , Ácidos Fosfóricos , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie
4.
Oper Dent ; 44(1): 42-53, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-29856702

RESUMEN

OBJECTIVE:: The purpose of this study was to evaluate the effect of reduced application times of universal adhesives on enamel bond fatigue and surface morphology of the treated enamel with constant force atomic force microscopy (AFM). METHODS:: Four universal adhesives-Adhese Universal (AU), Clearfil Universal Bond Quick (CU), G-Premio Bond (GP), and Scotchbond Universal Adhesive (SU)-were evaluated in a laboratory for their ability to adhesively bond resin composite to enamel. Shear bond strengths were initially determined using 15 specimens per test group for each adhesive. Shear fatigue strengths were then determined using 20 specimens per test group for each the adhesives. The fatigue specimens were loaded using a sine wave at a frequency of 20 Hz for 50,000 cycles or until failure occurred. AFM observations, surface Ra roughness measurements, and geometric surface area evaluations of enamel surface treated with the adhesive agents were also conducted. RESULTS:: A strong relationship was found between the initial shear bond strength and shear fatigue strength for enamel surface Ra roughness but not for geometric surface area. The initial shear bond strength and shear fatigue strength of CU and GP were not influenced by different application times, unlike those of AU and SU. While the surface area of enamel treated with the adhesive agents was not significantly influenced by different application times and type of adhesive, surface Ra roughness of the enamel in the AU and SU groups significantly increased with increasing application time, unlike CU and GP. CONCLUSIONS:: The results of this study suggest that universal adhesives, used with reduced application times, have adequate Ra surface roughness to provide sufficient resistance to enamel bond fatigue at application times from <1 second to 20 seconds, while the geometric surface area of adhesive-treated enamel did not show any significant changes at these different application times.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Cementos de Resina/química , Resinas Acrílicas , Ensayo de Materiales , Metacrilatos , Microscopía de Fuerza Atómica , Propiedades de Superficie , Factores de Tiempo
5.
Oper Dent ; 43(4): 437-446, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29547346

RESUMEN

OBJECTIVE: Limited information is available on how to polish and finish zirconia surfaces following computer-aided design/computer-aided manufacturing (CAD/CAM), specifically, how differing application forces and reuse of zirconia polishing systems affect zirconia topography. PURPOSE: To determine the effect of differing, clinically relevant, polishing application forces and multiple usages of polishing burs on the surface topography of CAD/CAM zirconia. METHODS: One hundred twenty 220-grit carbide finished zirconia disks were sintered according to manufacturer's directions and divided into two groups for the study of two coarse polishing bur types. Each group was divided into subgroups for polishing (15,000 rpm) at 15 seconds for 1.0 N, 4.5 N, or 11 N of force using a purpose-built fixture. Subgroups were further divided to study the effects of polishing for the first, fifth, 15th, and 30th bur use, simulating clinical procedures. Unpolished surfaces served as a control group. Surfaces were imaged with noncontact optical profilometry (OP) and atomic force microscopy (AFM) to measure average roughness values (Ra). Polishing burs were optically examined for wear. Scanning electron microscopy (SEM) was performed on burs and zirconia surfaces. One-way ANOVA with post hoc Tukey HSD (honest significant difference) tests (α=0.05) were used for statistical analyses. RESULTS: AFM and OP Ra values of all polished surfaces were significantly lower than those of the unpolished control. Different polishing forces and bur reuse showed no significant differences in AFM Ra. However, significant differences in OP Ra were found due to differing application forces and bur reuse between the first and subsequent uses. SEM and optical micrographs revealed notable bur wear, increasing with increasing reuse. SEM and AFM micrographs clearly showed polished, periodic zirconia surfaces. Nanoscale topography, as analyzed with kurtosis and average groove depth, was found dependent on the specific polishing bur type. CONCLUSIONS: These in vitro results suggest changes in OP Ra due to bur reuse and polishing application force. Within the parameters of this study, the resultant topography of zirconia polishing is force-dependent and the reuse of coarse polishing burs is possible without statistically significant differences in Ra values after initial use. Nanoscale and microscale topography were shown to depend on specific polishing bur type.


Asunto(s)
Pulido Dental/instrumentación , Circonio/química , Diseño Asistido por Computadora , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...