1.
Magn Reson Imaging ; 77: 14-20, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33309924

RESUMEN

INTRODUCTION: Visualization of passive devices during MRI-guided catheterizations often relies on a susceptibility artifact from the device itself or added susceptibility markers that impart a unique imaging signature. High-performance low field MRI systems offer reduced RF-induced heating of metallic devices during MRI-guided invasive procedures, but susceptibility artifacts are expected to diminish with field strength, reducing device visualization. In this study, field strength and orientation dependence of artifacts from susceptibility markers and metallic guidewires were evaluated using a prototype high-performance 0.55 T MRI system. MATERIALS AND METHODS: Artifact volume from nitinol and stainless steel passive susceptibility markers was quantified using histogram analysis of pixel intensities from three-dimensional gradient echo images at 0.55 T, 1.5 T and 3 T. In addition, visibility of commercially available clinical catheterization devices was compared between 0.55 T and 1.5 T using real-time bSSFP in phantoms and in vivo. RESULTS: A low-tensile strength stainless-steel marker produced field strength- and orientation-dependent artifact size (1.7 cm3, 1.95 cm3, 2.21 cm3 at 0.55 T, 1.5 T, 3 T, respectively). Whereas, a high-tensile strength steel marker, of the same alloy, produced field strength- and orientation-independent artifact size (3.35 cm3, 3.41 cm3, 3.42 cm3 at 0.55 T, 1.5 T, 3 T, respectively). Visibility of commercially available nitinol guidewires was reduced at 0.55 T, but imaging signature could be maintained using high-susceptibility stainless steel markers. DISCUSSION AND CONCLUSION: High-susceptibility stainless-steel markers generate field-independent artifacts between 0.55 T, 1.5 T and 3 T, indicating magnetic saturation at fields <0.55 T. Thus, artifact size can be tailored such that interventional devices produce identical imaging signatures across field strengths.


Asunto(s)
Artefactos , Cateterismo Cardíaco/instrumentación , Imagen por Resonancia Magnética/métodos , Metales , Aleaciones , Humanos , Fantasmas de Imagen
2.
Radiology ; 293(2): 384-393, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31573398

RESUMEN

Background Commercial low-field-strength MRI systems are generally not equipped with state-of-the-art MRI hardware, and are not suitable for demanding imaging techniques. An MRI system was developed that combines low field strength (0.55 T) with high-performance imaging technology. Purpose To evaluate applications of a high-performance low-field-strength MRI system, specifically MRI-guided cardiovascular catheterizations with metallic devices, diagnostic imaging in high-susceptibility regions, and efficient image acquisition strategies. Materials and Methods A commercial 1.5-T MRI system was modified to operate at 0.55 T while maintaining high-performance hardware, shielded gradients (45 mT/m; 200 T/m/sec), and advanced imaging methods. MRI was performed between January 2018 and April 2019. T1, T2, and T2* were measured at 0.55 T; relaxivity of exogenous contrast agents was measured; and clinical applications advantageous at low field were evaluated. Results There were 83 0.55-T MRI examinations performed in study participants (45 women; mean age, 34 years ± 13). On average, T1 was 32% shorter, T2 was 26% longer, and T2* was 40% longer at 0.55 T compared with 1.5 T. Nine metallic interventional devices were found to be intrinsically safe at 0.55 T (<1°C heating) and MRI-guided right heart catheterization was performed in seven study participants with commercial metallic guidewires. Compared with 1.5 T, reduced image distortion was shown in lungs, upper airway, cranial sinuses, and intestines because of improved field homogeneity. Oxygen inhalation generated lung signal enhancement of 19% ± 11 (standard deviation) at 0.55 T compared with 7.6% ± 6.3 at 1.5 T (P = .02; five participants) because of the increased T1 relaxivity of oxygen (4.7e-4 mmHg-1sec-1). Efficient spiral image acquisitions were amenable to low field strength and generated increased signal-to-noise ratio compared with Cartesian acquisitions (P < .02). Representative imaging of the brain, spine, abdomen, and heart generated good image quality with this system. Conclusion This initial study suggests that high-performance low-field-strength MRI offers advantages for MRI-guided catheterizations with metal devices, MRI in high-susceptibility regions, and efficient imaging. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Grist in this issue.


Asunto(s)
Cateterismo , Aumento de la Imagen/instrumentación , Imagen por Resonancia Magnética/instrumentación , Adulto , Artefactos , Cateterismo Cardíaco/instrumentación , Medios de Contraste , Diseño de Equipo , Femenino , Humanos , Imagen por Resonancia Magnética Intervencional/instrumentación , Metales , Relación Señal-Ruido
3.
J Cardiovasc Magn Reson ; 21(1): 16, 2019 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-30841903

RESUMEN

BACKGROUND: Catheter designs incorporating metallic braiding have high torque control and kink resistance compared with unbraided alternatives. However, metallic segments longer than a quarter wavelength (~ 12 cm for 1.5 T scanner) are prone to radiofrequency (RF) induced heating during cardiovascular magnetic resonance (CMR) catheterization. We designed a braid-reinforced catheter with interrupted metallic segments to mitigate RF-induced heating yet retain expected mechanical properties for CMR catheterization. METHODS: We constructed metal wire braided 6 Fr catheter shaft subassemblies using electrically insulated stainless-steel wires and off-the-shelf biocompatible polymers. The braiding was segmented, in-situ, using lasers to create non-resonant wire lengths. We compared the heating and mechanical performance of segmented- with un-segmented- metal braided catheter shaft subassemblies. RESULTS: The braiding segmentation procedure did not significantly alter the structural integrity of catheter subassemblies, torque response, push-ability, or kink resistance compared with non-segmented controls. Segmentation shortened the electrical length of individually insulated metallic braids, and therefore inhibited resonance during CMR RF excitation. RF-induced heating was reduced below 2 °C under expected use conditions in vitro. CONCLUSION: We describe a simple modification to the manufacture of metallic braided catheters that will allow CMR catheterization without RF-induced heating under contemporary scanning conditions at 1.5 T. The proposed segmentation pattern largely preserves braid structure and mechanical integrity while interrupting electrical resonance. This inexpensive design may be applicable to both diagnostic and interventional catheters and will help to enable a range of interventional procedures using real time CMR.


Asunto(s)
Materiales Biocompatibles , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Calor , Imagen por Resonancia Magnética Intervencional/instrumentación , Acero Inoxidable , Animales , Diseño de Equipo , Falla de Equipo , Ensayo de Materiales , Modelos Animales , Estrés Mecánico , Porcinos , Porcinos Enanos , Torque
4.
J Cardiovasc Magn Reson ; 17: 114, 2015 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-26695490

RESUMEN

BACKGROUND: CMR-guidance has the potential to improve tissue visualization during cardiovascular catheterization procedures and to reduce ionizing radiation exposure, but a lack of commercially available CMR guidewires limits widespread adoption. Standard metallic guidewires are considered to be unsafe in CMR due to risks of RF-induced heating. Here, we propose the use of RF-efficient gradient echo (GRE) spiral imaging for reduced guidewire heating (low flip angle, long readout), in combination with positive contrast for guidewire visualization. METHODS: A GRE spiral sequence with 8 interleaves was used for imaging. Positive contrast was achieved using through-slice dephasing such that the guidewire appeared bright and the background signal suppressed. Positive contrast images were interleaved with anatomical images, and real-time image processing was used to produce a color overlay of the guidewire on the anatomy. Temperature was measured with a fiber-optic probe attached to the guidewire in an acrylic gel phantom and in vivo. RESULTS: Left heart catheterization was performed on swine using the real-time color overlay for procedural guidance with a frame rate of 6.25 frames/second. Using our standard Cartesian real-time imaging (flip angle 60°), temperature increases up to 50 °C (phantom) and 4 °C (in vivo) were observed. In comparison, spiral GRE images (8 interleaves, flip angle 10°) generated negligible heating measuring 0.37 °C (phantom) and 0.06 °C (in vivo). CONCLUSIONS: The ability to use commercial metallic guidewires safely during CMR-guided catheterization could potentially expedite clinical translation of these methods.


Asunto(s)
Aleaciones/química , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Calor , Interpretación de Imagen Asistida por Computador/instrumentación , Imagen por Resonancia Magnética Intervencional/instrumentación , Fantasmas de Imagen , Animales , Cateterismo Cardíaco/métodos , Diseño de Equipo , Falla de Equipo , Tecnología de Fibra Óptica , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética Intervencional/métodos , Ensayo de Materiales , Modelos Animales , Porcinos , Factores de Tiempo
5.
J Cardiovasc Magn Reson ; 17: 105, 2015 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-26620420

RESUMEN

BACKGROUND: Conventional guidewires are not suitable for use during cardiovascular magnetic resonance (CMR) catheterization. They employ metallic shafts for mechanical performance, but which are conductors subject to radiofrequency (RF) induced heating. To date, non-metallic CMR guidewire designs have provided inadequate mechanical support, trackability, and torquability. We propose a metallic guidewire for CMR that is by design intrinsically safe and that retains mechanical performance of commercial guidewires. METHODS: The NHLBI passive guidewire is a 0.035" CMR-safe, segmented-core nitinol device constructed using short nitinol rod segments. The electrical length of each segment is less than one-quarter wavelength at 1.5 Tesla, which eliminates standing wave formation, and which therefore eliminates RF heating along the shaft. Each of the electrically insulated segments is connected with nitinol tubes for stiffness matching to assure uniform flexion. Iron oxide markers on the distal shaft impart conspicuity. Mechanical integrity was tested according to International Organization for Standardization (ISO) standards. CMR RF heating safety was tested in vitro in a phantom according to American Society for Testing and Materials (ASTM) F-2182 standard, and in vivo in seven swine. Results were compared with a high-performance commercial nitinol guidewire. RESULTS: The NHLBI passive guidewire exhibited similar mechanical behavior to the commercial comparator. RF heating was reduced from 13 °C in the commercial guidewire to 1.2 °C in the NHLBI passive guidewire in vitro, using a flip angle of 75°. The maximum temperature increase was 1.1 ± 0.3 °C in vivo, using a flip angle of 45°. The guidewire was conspicuous during left heart catheterization in swine. CONCLUSIONS: We describe a simple and intrinsically safe design of a metallic guidewire for CMR cardiovascular catheterization. The guidewire exhibits negligible heating at high flip angles in conformance with regulatory guidelines, yet mechanically resembles a high-performance commercial guidewire. Iron oxide markers along the length of the guidewire impart passive visibility during real-time CMR. Clinical translation is imminent.


Asunto(s)
Aleaciones/química , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Imagen por Resonancia Magnética Intervencional/instrumentación , Imagen por Resonancia Magnética/instrumentación , Animales , Conductividad Eléctrica , Diseño de Equipo , Falla de Equipo , Compuestos Férricos/química , Marcadores Fiduciales , Calor , Ensayo de Materiales , Modelos Animales , Fantasmas de Imagen , Porcinos