Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Radiology ; 238(1): 143-9, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16304088

RESUMEN

PURPOSE: To prospectively compare dark-lumen magnetic resonance (MR) colonography with conventional colonoscopy in the detection of colorectal polyps. MATERIALS AND METHODS: Local ethical committee approval and informed consent were obtained. One hundred consecutive patients (56 men, 44 women; mean age +/- standard deviation, 67.7 years +/- 14.7; range, 25-82 years) who were referred for conventional colonoscopy from January 2003 to January 2004 underwent MR colonography and conventional colonoscopy after standard precolonoscopic bowel cleansing. Colonoscopy was performed immediately after MR colonography. For MR colonography, the colon was filled with approximately 2000 mL of tap water. Imaging was performed with a 1.5-T MR unit with patients in the prone position. A T1-weighted three-dimensional volumetric interpolated breath-hold sequence was performed before and 75 seconds after intravenous administration of 0.2 mmol gadobenate dimeglumine per kilogram of body weight. Results of MR colonography were analyzed on a per-polyp and per-patient basis. Findings at colonoscopy were used as the reference for determining accuracy, sensitivity, specificity, and positive and negative predictive values of MR colonography. RESULTS: Of 100 patients recruited for study, 92 (52 men, 40 women; mean age, 61.5 years +/- 14.5; range, 25-82 years) underwent complete MR and conventional colonoscopy examinations. Forty-three of the 92 patients (47%) had normal findings at conventional colonoscopy. In the other 49 patients (53%), conventional colonoscopy depicted 107 polyps (82 adenomas, 25 hyperplastic polyps) and seven carcinomas. At per-polyp analysis, sensitivity of MR colonography in the detection of adenomatous polyps was 100% for polyps at least 10 mm in diameter and 84.2% for polyps 6-9 mm in diameter. At per-patient analysis, the accuracy of MR colonography was 93.1% (sensitivity, 89%; specificity, 96%) if detection of adenomatous polyps of all sizes was considered. CONCLUSION: Dark-lumen MR colonography is a promising modality with high accuracy for detecting colorectal polyps larger than 5 mm in diameter.


Asunto(s)
Pólipos del Colon/diagnóstico , Colonoscopía , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste/administración & dosificación , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Masculino , Meglumina/administración & dosificación , Meglumina/análogos & derivados , Persona de Mediana Edad , Compuestos Organometálicos/administración & dosificación , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sensibilidad y Especificidad
2.
Med Klin (Munich) ; 100(2): 115-22, 2005 Feb 15.
Artículo en Alemán | MEDLINE | ID: mdl-15711908

RESUMEN

Magnetic resonance imaging (MRI) has been called the most important development in medical diagnosis since the discovery of the X-ray more than 100 years ago. The effectiveness of MRI has been expanded to a variety of gastrointestinal disorders. The gastroenterologist's attention is currently focused on biliopancreatic and bowel diseases. Magnetic resonance cholangiopancreatography (MRCP) has become a competitive replacement for diagnostic endoscopic retrograde cholangiopancreatography (ERCP) in a variety of hepatobiliary and pancreatic diseases. MR enteroscopy has the potential to become the preferred method for evaluating the entire small bowel, while on the other hand virtual colonoscopy is far from being promoted as a tool for general screening purposes in suspected colon diseases. In summary, whether or not the survival of endoscopy is under debate, MRI could mark a historic turning point in gastroenterology. So, MRI hardware might interdisciplinarily be used by, e. g., radiologists and gastroenterologists.


Asunto(s)
Enfermedades del Sistema Digestivo/diagnóstico , Enfermedades Gastrointestinales/diagnóstico , Aumento de la Imagen , Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Imagen por Resonancia Magnética , Colangiopancreatografia Retrógrada Endoscópica , Pancreatocolangiografía por Resonancia Magnética , Colonografía Tomográfica Computarizada , Humanos , Sensibilidad y Especificidad
3.
Dig Dis ; 22(1): 18-25, 2004.
Artículo en Inglés | MEDLINE | ID: mdl-15292691

RESUMEN

The introduction of endoscopic retrograde cholangiopancreatography (ERCP) in the early 1970s provided gastroenterologists with a number of diagnostic as well as therapeutic possibilities for examining biliopancreatic systems. In the meantime, magnetic resonance cholangiopancreatography presents a non-invasive alternative to diagnostic ECRP providing the advantage of a lower rate of possible complications. This article addresses the two methods presently available for differentiating pancreatic tumors. The objective of this article is to describe the advantages and disadvantages as well as the possibilities inherent in both methods.


Asunto(s)
Colangiopancreatografia Retrógrada Endoscópica/métodos , Imagen por Resonancia Magnética/métodos , Páncreas/patología , Neoplasias Pancreáticas/diagnóstico , Adenoma de Células de los Islotes Pancreáticos/diagnóstico por imagen , Adenoma de Células de los Islotes Pancreáticos/patología , Cistoadenoma Mucinoso/diagnóstico por imagen , Cistoadenoma Mucinoso/patología , Diagnóstico Diferencial , Endoscopía del Sistema Digestivo/métodos , Femenino , Humanos , Masculino , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...