Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Perfusion ; 38(3): 574-579, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35077261

RESUMEN

INTRODUCTION: Despite being a daily clinical application in cardiac operating theaters, an evidence-based approach on how to optimally initiate the heart-lung machine (HLM) to prevent critical phases of cerebral ischemia is still lacking. We therefore designed a study comparing two different initiation times for starting the cardiopulmonary bypass (CPB). METHODS: We conducted a monocentric, randomized, and prospective study comparing the impact of two initiation times, a rapid initiation of 15 s and a slow initiation of 180 s to reach the full target flow rate of 2.5 L/min/m2 times the body surface area, on cerebral tissue oxygenation by near infrared spectroscopy measurements. RESULTS: The absolute values in tissue oxygenation index (TOI) showed no difference between the groups before and after the CPB with a 10% drop in oxygenation index in both groups due to the hemodilution through the HLM priming. Looking at the kinetics a rapid initiation of CPB produced a higher negative rate of change in TOI with a total of 21% in critical oxygenation readings compared to 6% in the slow initiation group. CONCLUSION: In order to avoid critical phases of cerebral ischemia during the initiation of CPB for cardiac procedures, we propose an initiation time of at least 90 s to reach the 100% of target flow rate of the HLM.


Asunto(s)
Isquemia Encefálica , Puente Cardiopulmonar , Humanos , Puente Cardiopulmonar/métodos , Estudios Prospectivos , Oximetría/métodos , Análisis de los Gases de la Sangre , Oxígeno , Circulación Cerebrovascular
2.
Perfusion ; 38(7): 1360-1383, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-35961654

RESUMEN

The landmark 2016 Minimal Invasive Extracorporeal Technologies International Society (MiECTiS) position paper promoted the creation of a common language between cardiac surgeons, anesthesiologists and perfusionists which led to the development of a stable framework that paved the way for the advancement of minimal invasive perfusion and related technologies. The current expert consensus document offers an update in areas for which new evidence has emerged. In the light of published literature, modular minimal invasive extracorporeal circulation (MiECC) has been established as a safe and effective perfusion technique that increases biocompatibility and ultimately ensures perfusion safety in all adult cardiac surgical procedures, including re-operations, aortic arch and emergency surgery. Moreover, it was recognized that incorporation of MiECC strategies advances minimal invasive cardiac surgery (MICS) by combining reduced surgical trauma with minimal physiologic derangements. Minimal Invasive Extracorporeal Technologies International Society considers MiECC as a physiologically-based multidisciplinary strategy for performing cardiac surgery that is associated with significant evidence-based clinical benefit that has accrued over the years. Widespread adoption of this technology is thus strongly advocated to obtain additional healthcare benefit while advancing patient care.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Adulto , Humanos , Procedimientos Quirúrgicos Cardíacos/métodos , Circulación Extracorporea/métodos , Perfusión , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Corazón
3.
Artículo en Inglés | MEDLINE | ID: mdl-36088142

RESUMEN

OBJECTIVES: Degeneration of mitral prostheses/rings may be treated by redo surgery, and, recently, by transcatheter valve-in-valve/ring implantation. This multicenter registry presents results of transcatheter valve-in-valve and repeat surgery for prostheses/rings degeneration. METHODS: Data provided by 10 German heart centers underwent propensity score-matched retrospective analysis. The primary endpoint was 30-day/midterm mortality. Perioperative outcome was assessed according to the Mitral Valve Academic Research Consortium criteria. Further, the influence of moderate or greater tricuspid regurgitation (TR) on 30-day/midterm mortality was analyzed. RESULTS: Between 2014 and 2019, 273 patients (79 transcatheter mitral valve-in-valve [TM-ViV] and 194 redo mitral valve replacement [Re-MVR]) underwent repeat procedure for mitral prosthesis/ring degeneration. Propensity score matching distinguished 79 patient pairs. European System for Cardiac Operative Risk Evaluation (EuroSCORE) II-predicted risk was 15.7 ± 13.7% in the TM-ViV group and 15.0% ± 12.7% in the Re-MVR group (P = .5336). TM-ViV patients were older (74.73 vs 72.2 years; P = .0030) and had higher incidence of atrial fibrillation (54 vs 40 patients; P = .0233). Severe TR incidence was similar (17.95% in TM-ViV vs 14.10%; P = .1741). Sixty-eight TM-ViV patients previously underwent mitral valve replacement, whereas 41 Re-MVR patients underwent valve repair (P < .0001). Stenosis was the leading degeneration mechanism in 42 TM-ViV versus 22 Re-MVR patients (P < .0005). The 30-day/midterm mortality did not differ between groups. Moderate or greater TR was a predictor of total (odds ratio [OR], 4.36; P = .0011), 30-day (OR, 3.76; P = .0180), and midterm mortality (OR, 4.30; P = .0378), irrespective of group. CONCLUSIONS: In both groups, observed mortality was less than predicted. Redo surgery enabled treatment of concomitant conditions, such as atrial fibrillation or TR. TR was shown to be a predictor of total, 30-day, and midterm mortality in both groups.

4.
Thorac Cardiovasc Surg ; 70(6): 452-457, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35998669

RESUMEN

The evolution and progress in cardiovascular medicine and substantial changes in the German health care system require both a reflection of the principles of patient-centered care in general and an update of the criteria that define a department of cardiac surgery in Germany. This position paper lists the core requirements for a cardiac surgical department with regard to infrastructure, facilities, necessary staff, and standard of care (processes). This standard may be used by hospitals and health care providers to ensure the safety and quality of cardiac surgical departments in Germany.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Atención a la Salud , Alemania , Humanos , Resultado del Tratamiento
5.
Front Robot AI ; 8: 611251, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34179105

RESUMEN

Certain telerobotic applications, including telerobotics in space, pose particularly demanding challenges to both technology and humans. Traditional bilateral telemanipulation approaches often cannot be used in such applications due to technical and physical limitations such as long and varying delays, packet loss, and limited bandwidth, as well as high reliability, precision, and task duration requirements. In order to close this gap, we research model-augmented haptic telemanipulation (MATM) that uses two kinds of models: a remote model that enables shared autonomous functionality of the teleoperated robot, and a local model that aims to generate assistive augmented haptic feedback for the human operator. Several technological methods that form the backbone of the MATM approach have already been successfully demonstrated in accomplished telerobotic space missions. On this basis, we have applied our approach in more recent research to applications in the fields of orbital robotics, telesurgery, caregiving, and telenavigation. In the course of this work, we have advanced specific aspects of the approach that were of particular importance for each respective application, especially shared autonomy, and haptic augmentation. This overview paper discusses the MATM approach in detail, presents the latest research results of the various technologies encompassed within this approach, provides a retrospective of DLR's telerobotic space missions, demonstrates the broad application potential of MATM based on the aforementioned use cases, and outlines lessons learned and open challenges.

6.
Med Klin Intensivmed Notfmed ; 116(7): 605-608, 2021 Oct.
Artículo en Alemán | MEDLINE | ID: mdl-33792739

RESUMEN

Mechanical circulatory support using extracorporeal life support systems (ECLS) has significantly increased in recent years. These critically ill patients pose special challenges to the multiprofessional treatment team and require comprehensive, interdisciplinary and interprofessional concepts. For this reason, to ensure the best possible patient care a standardized ECLS training module has been created at national specialist society level, taking emergency and intensive care management into account.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Consenso , Humanos
7.
Anaesthesist ; 70(7): 603-606, 2021 07.
Artículo en Alemán | MEDLINE | ID: mdl-33792740

RESUMEN

Mechanical circulatory support using extracorporeal life support systems (ECLS) has significantly increased in recent years. These critically ill patients pose special challenges to the multiprofessional treatment team and require comprehensive, interdisciplinary and interprofessional concepts. For this reason, to ensure the best possible patient care a standardized ECLS training module has been created at national specialist society level, taking emergency and intensive care management into account.


Asunto(s)
Reanimación Cardiopulmonar , Oxigenación por Membrana Extracorpórea , Consenso , Cuidados Críticos , Humanos , Sistemas de Manutención de la Vida
8.
Interact Cardiovasc Thorac Surg ; 30(5): 661-665, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32031624

RESUMEN

Consensus paper of the German Society of Cardiovascular Engineering, the German Society for Thoracic and Cardiovascular Surgery, the German Society of Cardiology, the German Society of Pediatric Cardiology, the German Society of Anesthesiology and Intensive Care Medicine, the German Interdisciplinary Association of Intensive Care Medicine and Emergency Medicine and the German Society of Medical Intensive Care and Emergency Medicine.


Asunto(s)
Consenso , Cuidados Críticos/normas , Conocimientos, Actitudes y Práctica en Salud , Perfusión/normas , Alemania , Humanos
9.
Thorac Cardiovasc Surg ; 67(3): 191-202, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-29290078

RESUMEN

INTRODUCTION: The recommended minimum activated clotting time (ACT) level for cardiopulmonary bypass (CPB) of 480 seconds originated from investigations with bubble oxygenators and uncoated extracorporeal circulation (ECC) systems. Modern minimal invasive ECC (MiECC) systems are completely closed circuits containing a membrane oxygenator and a tip-to-tip surface coating. We hypothesized that surface coating and the "closed-loop" design allow the MiECC to safely run with lower ACT levels and that an ACT level of 300 seconds can be safely applied without thromboembolic complications. The aim of this study was to investigate the potential risks during application of reduced heparin levels in patients undergoing coronary surgery. METHODS: In this study, 68 patients undergoing coronary artery bypass grafting with MiECC were randomized to either the study group with an ACT target of 300 seconds or the control group with an ACT of 450 seconds. All other factors of MiECC remained unchanged. RESULTS: The study group received significantly less heparin and protamine (heparin [international units] median [min-max], Red_AC: 32,800 [23,000-51,500] vs. Full_AC: 50,000 [35,000-65,000] p < 0.001; protamine [international units], Red_AC: 18,000 [10,000-35,000] vs. Full_AC: 30,000 [20,000-45,000] p < 0.001). The ACT in the study group was significantly lower at the start of MiECC (mean ± standard deviation: study group 400 ± 112 vs. control group 633 ± 177; p < 0.0001). Before termination of CPB the ACT levels were: study group 344 ± 60 versus control group 506 ± 80. In both groups, the values of the endogenous thrombin potential (ETP) decreased simultaneously. None of the study participants experienced thromboembolic complications. CONCLUSION: Since no evidence of increased thrombin formation (ETP) was found from a laboratory standpoint, we concluded that the use of MiECC with a reduced anticoagulation strategy seems possible. This alternative anticoagulation strategy leads to significant reduction in dosages of both heparin and protamine. We can confidently move forward with investigating this anticoagulation concept. However, to establish clinical safety of ACT below 300 seconds, we need larger clinical studies.


Asunto(s)
Anticoagulantes/administración & dosificación , Coagulación Sanguínea/efectos de los fármacos , Puente Cardiopulmonar/métodos , Puente de Arteria Coronaria , Oxigenación por Membrana Extracorpórea/métodos , Heparina/administración & dosificación , Tiempo de Coagulación de la Sangre Total , Anciano , Anticoagulantes/efectos adversos , Puente Cardiopulmonar/efectos adversos , Puente de Arteria Coronaria/efectos adversos , Oxigenación por Membrana Extracorpórea/efectos adversos , Estudios de Factibilidad , Femenino , Alemania , Heparina/efectos adversos , Antagonistas de Heparina/administración & dosificación , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Valor Predictivo de las Pruebas , Protaminas/administración & dosificación , Factores de Riesgo , Tromboembolia/sangre , Tromboembolia/etiología , Tromboembolia/prevención & control , Factores de Tiempo , Resultado del Tratamiento
10.
Clin Res Cardiol ; 108(5): 455-464, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30361819

RESUMEN

Extracorporeal cardiopulmonary resuscitation (eCPR) may be considered as a rescue attempt for highly selected patients with refractory cardiac arrest and potentially reversible aetiology. Currently, there are no randomised, controlled studies on eCPR. Thus, prospective validated predictors of benefit and outcome are lacking. Currently, selection criteria and procedure techniques differ across hospitals and standardised algorithms are lacking. Based on expert opinion, the present consensus statement provides a first standardised treatment algorithm for eCPR.


Asunto(s)
Reanimación Cardiopulmonar/normas , Consenso , Oxigenación por Membrana Extracorpórea/normas , Paro Cardíaco Extrahospitalario/terapia , Selección de Paciente , Humanos
11.
Perfusion ; 33(2): 136-147, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28937313

RESUMEN

OBJECTIVE: The postoperative systemic inflammatory response after cardiopulmonary bypass (CPB) is still an undesirable side-effect after cardiac surgery. It is most likely caused by blood contact with foreign surfaces and by the surgical trauma itself. However, the recirculation of activated shed mediastinal blood is another main cause of blood cell activation and cytokine release. Minimal invasive extracorporeal circulation (MiECC) comprises a completely closed circuit, coated surfaces and the separation of suction blood. We hypothesized that MiECC, with separated cell saved blood, would induce less of a systemic inflammatory response than MiECC with no cell-saver. The aim of this study was, therefore, to investigate the impact of cell washing shed blood from the operating field versus direct return to the ECC on the biomarkers for systemic inflammation. MATERIAL AND METHODS: In the study, patients with MiECC and cell-saver were compared with the control group, patients with MiECC and direct re-transfusion of the drawn blood shed from the surgical field. RESULTS: High amounts of TNF-α (+ 120% compared to serum blood) were found in the shed blood itself, but a significant reduction was demonstrated with the use of a cell-saver (TNF-α ng/l post-ECC 10 min: 9.5±3.5 vs. 19.7±14.5, p<0.0001). The values for procalcitonin were not significantly increased in the control group (6h: 1.07±3.4 vs. 2.15±9.55, p=0.19) and lower for C-reactive protein (CRP) (24h: 147.1±64.0 vs.134.4±52.4 p=0.28). CONCLUSION: The use of a cell-saver and the processing of shed blood as an integral part of MiECC significantly reduces the systemic cytokine load. We, therefore, recommend the integration of cell-saving devices in MiECC to reduce the perioperative inflammatory response.


Asunto(s)
Circulación Extracorporea/métodos , Inflamación/sangre , Anciano , Circulación Extracorporea/efectos adversos , Femenino , Humanos , Masculino , Periodo Posoperatorio , Estudios Prospectivos , Resultado del Tratamiento
12.
Inflammation ; 40(2): 442-453, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27995357

RESUMEN

The endothelium serves as a selective barrier and controls the exchange of nutrients, hormones, and leukocytes between blood and tissues. Molecular mechanisms contributing to the pathogenesis of endothelial barrier dysfunction remain incompletely understood. Accumulating evidence implicates bone morphogenetic protein (BMP)-modulator BMPER as a key regulator in endothelial biology. Herein, we analyze the impact of BMPER in the control of endothelial barrier function. To assess the role of BMPER in vascular barrier function in mice, we measured the leakage of Evans blue dye from blood into interstitial lung tissue. BMPER+/- mice exhibited a significantly higher degree of vascular leak compared with wild-type siblings. In accordance with our in vivo observation, siRNA-based BMPER knockdown in human umbilical endothelial cells increased endothelial permeability measured by FITC-dextran passage in transwell assays. Mechanistically, BMPER knockdown reduced the expression of VE-cadherin, a pivotal component of endothelial adherens junctions. Conversely, recombinant human BMPER protein upregulated VE-cadherin protein levels and improved endothelial barrier function in transwell assays. The effects of BMPER knockdown on VE-cadherin expression and endothelial permeability were induced by enhanced BMP activity. Supporting this notion, activation of BMP4-Smad-Id1 signaling reduced VE-cadherin levels and impaired endothelial barrier function in vitro. In vivo, Evans blue dye accumulation was higher in the lungs of BMP4-treated C57BL/6 mice compared to controls indicating that BMP4 increased vascular permeability. High levels of BMPER antagonized BMP4-Smad5-Id1 signaling and prevented BMP4-induced downregulation of VE-cadherin and endothelial leakage, suggesting that BMPER exerts anti-BMP effects and restores endothelial barrier function. Taken together, this data demonstrates that BMPER-modulated BMP pathway activity regulates VE-cadherin expression and vascular barrier function.


Asunto(s)
Proteínas Portadoras/fisiología , Endotelio Vascular/fisiología , Animales , Antígenos CD/metabolismo , Proteína Morfogenética Ósea 4/administración & dosificación , Proteína Morfogenética Ósea 4/metabolismo , Proteínas Morfogenéticas Óseas/metabolismo , Cadherinas/metabolismo , Permeabilidad Capilar/efectos de los fármacos , Proteínas Portadoras/genética , Humanos , Ratones , Ratones Endogámicos C57BL , ARN Interferente Pequeño/farmacología , Transducción de Señal
14.
Interact Cardiovasc Thorac Surg ; 22(5): 647-62, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26819269

RESUMEN

Minimal invasive extracorporeal circulation (MiECC) systems have initiated important efforts within science and technology to further improve the biocompatibility of cardiopulmonary bypass components to minimize the adverse effects and improve end-organ protection. The Minimal invasive Extra-Corporeal Technologies international Society was founded to create an international forum for the exchange of ideas on clinical application and research of minimal invasive extracorporeal circulation technology. The present work is a consensus document developed to standardize the terminology and the definition of minimal invasive extracorporeal circulation technology as well as to provide recommendations for the clinical practice. The goal of this manuscript is to promote the use of MiECC systems into clinical practice as a multidisciplinary strategy involving cardiac surgeons, anaesthesiologists and perfusionists.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Consenso , Circulación Extracorporea/estadística & datos numéricos , Procedimientos Quirúrgicos Mínimamente Invasivos/estadística & datos numéricos , Sociedades Médicas , Humanos
15.
Interact Cardiovasc Thorac Surg ; 21(1): 102-7, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25911678

RESUMEN

OBJECTIVES: At the moment, the main application of minimally invasive extracorporeal circulation (MiECC) is reserved for elective cardiac operations such as coronary artery bypass grafting (CABG) and/or aortic valve replacement. The purpose of this study was to compare the outcome of emergency CABG operations using either MiECC or conventional extracorporeal circulation (CECC) in patients requiring emergency CABG with regard to the perioperative course and the occurrence of major adverse cardiac and cerebral events (MACCE). METHODS: We analysed the emergency CABG operations performed by a single surgeon, between January 2007 and July 2013, in order to exclude the differences in surgical technique. During this period, 187 emergency CABG patients (113 MiECC vs 74 CECC) were investigated retrospectively with respect to the following parameters: in-hospital mortality, MACCE, postoperative hospital stay and perioperative transfusion rate. RESULTS: The mean logistic European System for Cardiac Operative Risk Evaluation was higher in the CECC group (MiECC 12.1 ± 16 vs CECC 15.0 ± 20.8, P = 0.15) and the number of bypass grafts per patient was similar in both groups (MiECC 2.94 vs CECC 2.93). There was no significant difference in the postoperative hospital stay or in major postoperative complications. The in-hospital mortality was higher in the CECC group 6.8% versus MiECC 4.4% (P = 0.48). The perioperative transfusion rate was lower with MiECC compared with CECC (MiECC 2.6 ± 3.2 vs CECC 3.8 ± 4.2, P = 0.025 units of blood per patient). CONCLUSIONS: In our opinion, the use of MiECC in urgent CABG procedures is safe, feasible and shows no disadvantages compared with the use of CECC. Emergency operations using the MiECC system showed a significantly lower blood transfusion rate and better results concerning the unadjusted in-hospital mortality.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Oxigenación por Membrana Extracorpórea/métodos , Anciano , Transfusión Sanguínea , Trastornos Cerebrovasculares/etiología , Trastornos Cerebrovasculares/mortalidad , Trastornos Cerebrovasculares/terapia , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Urgencias Médicas , Oxigenación por Membrana Extracorpórea/efectos adversos , Oxigenación por Membrana Extracorpórea/mortalidad , Estudios de Factibilidad , Femenino , Hemodinámica , Mortalidad Hospitalaria , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Infarto del Miocardio/terapia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
16.
Thorac Cardiovasc Surg ; 63 Suppl 2: S131-96, 2015 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-25588185

RESUMEN

Although intra-aortic balloon pumping (IABP) is the most frequently used mechanical cardiac assist device in cardiothoracic surgery, there are only guidelines for substantive sections of aortic counterpulsation including prophylactic and postoperative use. In contrast, evidence-based recommendations are still lacking concerning intraoperative use, management, contraindication and other relevant issues. According to international surveys, important aspects of IABP usage show a wide variation in clinical practice. The results of a national questionnaire performed before initiation of this guideline confirmed these findings and demonstrated a clear need for the development of a consensus-based guideline. Therefore, the presented multidisciplinary S-3-guideline was developed under the direction of the German Society for Thoracic and Cardiovascular Surgery (Deutsche Gesellschaft für Thorax-, Herz- und Gefäßchirurgie, DGTHG) to make evidence-based recommendations for the usage of aortic counterpulsation after cardiothoracic surgery according to the requirements of the Association of the Scientific Medical Societies in Germany (AWMF) and the Medical Centre for Quality (Ärztliches Zentrum für Qualität - (ÄZQ)). Main topics discussed in this guideline involve IABP support in the prophylactic, preoperative, intraoperative and postoperative setting as well as the treatment of right heart failure, contraindications, anticoagulation, monitoring, weaning, and limitations of IABP therapy. The presented 15 key messages of the guideline were approved after two consensus meetings under moderation of the AWMF with participation of the German Society of Cardiology (DGK), German Society of Anaesthesiology and Intensive Care Medicine (DGAI), German Interdisciplinary Association for Intensive Care (DIVI) and the German Society for Cardiovascular Engineering (DGfK).


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Contrapulsador Intraaórtico/normas , Complicaciones Posoperatorias/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Consenso , Conducta Cooperativa , Medicina Basada en la Evidencia , Alemania , Humanos , Contrapulsador Intraaórtico/efectos adversos , Selección de Paciente , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/fisiopatología , Factores de Riesgo , Resultado del Tratamiento
18.
J Extra Corpor Technol ; 46(2): 166-9, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25208435

RESUMEN

The use of extracorporeal life support systems (ECLS) in patients with postcardiotomy low cardiac output syndrome (LCO) as a bridge to recovery and bridge to implantation of ventricular assist device (VAD) is common nowadays. A 59-year-old patient with acute myocardial infarction received a percutaneous transluminal angioplasty and stenting of the circumflex artery. During catheterization of the left coronary artery (LAD), the patient showed ventricular fibrillation and required defibrillation and cardiopulmonary resuscitation. After implantation of an intra-aortic balloon pump, the patient immediately was transmitted to the operating room. He received emergency coronary artery bypass grafting in a beating heart technique using pump-assisted minimal extracorporeal circulation circuit (MECC). Two bypass grafts were performed to the LAD and the right posterior descending artery. Despite initial successful weaning off cardiopulmonary bypass with high-dose inotropic support, the patient presented postcardiotomy LCO and an ECLS was implanted. The primary setup of the heparin-coated MECC system was modified and used postoperatively. As a result of the absence of an in-house VAD program, the patient was switched to a transportable ECLS the next day and was transferred by helicopter to the nearest VAD center where the patient received a successful insertion of a left VAD 3 days later.


Asunto(s)
Ambulancias Aéreas , Ceguera/complicaciones , Circulación Extracorporea/instrumentación , Corazón Auxiliar , Infarto del Miocardio/terapia , Transporte de Pacientes/métodos , Ceguera/terapia , Diseño de Equipo , Análisis de Falla de Equipo , Circulación Extracorporea/métodos , Humanos , Masculino , Persona de Mediana Edad , Miniaturización , Infarto del Miocardio/diagnóstico , Transferencia de Pacientes/métodos , Sistemas de Atención de Punto , Implantación de Prótesis , Resultado del Tratamiento
20.
J Extra Corpor Technol ; 42(1): 30-9, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20437789

RESUMEN

Minimized extracorporeal circulation (MECC, Maquet, Cardiopulmonary AG, Hirrlingen, Germany) is an established procedure to perform coronary revascularization. Studies showed positive effects of MECC compared to conventional cardiopulmonary bypass (CCPB) procedures in terms of transfusion requirements, less inflammation reactions, and neurological impairments. Recent retrospective studies showed higher mean arterial pressure (MAP) and a lower frequency of vasoactive drug use. We addressed this issue in this study. The hypothesis was to find a higher MAP during coronary bypass grafting surgery in patients treated with MECC systems. We performed a prospective, controlled, randomized trial with 40 patients either assigned to MECC (n = 18) or CCPB (n = 22) undergoing coronary bypass grafting. Primary endpoints were the perioperative course of mean arterial pressure, and the consumption of norepinephrine. Secondary endpoints were the regional cerebral and renal oxygen saturation (rSO2) as an indicator of area perfusion and the course of hematocrit. Clinical and demographic characteristics did not significantly differ between both groups. Thirty-day mortality was 0%. At four of five time points during extracorporeal circulation (ECC) MAP values were significantly higher in the MECC group compared to CCPB patients (after starting the ECC 60 +/- 11 mmHg vs. 49 +/- 10 mmHg, p = .002). MECC patients received significantly less norepinephrine (MECC 22.5 +/- 35 microg vs. CCPB 60.5 +/- 75 microg, p = .045). The rSO2 measured at right and left forehead and the renal area was similar for both groups during ECC and significantly higher at CCPB group 1 and 4 hours after termination of CPB. Minimized extracorporeal circulation provides a higher mean arterial pressure during ECC and we found a lower consumption of vasoactive drugs in the MECC group. There was a decrease in regional tissue saturation at 1 and 4 hours post bypass in the MECC group possibly due to increased systemic inflammation and extravascular fluid shift in the CCPB group.


Asunto(s)
Circulación Coronaria , Circulación Extracorporea/métodos , Reperfusión Miocárdica/métodos , Oxígeno/sangre , Anciano , Presión Sanguínea , Femenino , Humanos , Masculino , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...