Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Int J Cardiol ; 321: 24-29, 2020 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-32800911

RESUMEN

OBJECTIVE: We aimed to assess the use of enhanced stent visualisation (ESV) on outcomes, after PCI with overlapping stents, specifically using CLEARstent technology. BACKGROUND: Stent underexpansion and overlap are both significant risk factors for restenosis and stent thrombosis. Enhanced stent visualisation (e.g. CLEARstent) systems could provide important data to reduce under-expansion and stent overlap. METHODS: This was a cohort study based on this institution's percutaneous coronary intervention (PCI) registry. A total of 2614 patients who had PCI for stable angina or acute coronary syndromes (ACS, excluding cardiogenic shock) with overlapping 2nd generation drug eluting stents (DES) in the same vessel between May 2015 and January 2018 were included in the analysis. Patients were divided into ESV (n = 1354) and no ESV guided intervention (n = 1260). The primary end-point was major adverse cardiovascular events (MACE: target vessel revascularisation, target vessel myocardial infarction and all-cause mortality) recorded at a median follow up of 2.4 years. RESULTS: Groups were comparable for patient characteristics (age, diabetes mellitus, ACS presentation). A significant difference in MACE was observed between patients who underwent ESV-guided PCI (9.5%) compared with patients who underwent Standard PCI (14.4%, p = .018). This difference was mainly driven by reduced rates of target vessel revascularisation and recurrent myocardial infarction. Overall this difference persisted after multivariate Cox analysis (HR 0.86, 95% CI: 0.73-0.98) and propensity matching (HR = 0.88, 95% CI: 0.69-0.99). CONCLUSION: We suggest that routine clinical use of ESV technology during PCI can be useful, and is associated with better medium-term angiographic and clinical outcomes. Further study is required to build on this promising signal.


Asunto(s)
Intervención Coronaria Percutánea , Angiografía , Estudios de Cohortes , Angiografía Coronaria , Humanos , Intervención Coronaria Percutánea/efectos adversos , Factores de Riesgo , Stents , Resultado del Tratamiento
4.
Heart ; 99(17): 1275-81, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23825097

RESUMEN

OBJECTIVE: Surgical correction of congenital aortic coarctation can lead to a number of important problems including late pseudoaneurysm formation. Redo surgery has a significant risk. Endovascular stent graft repair is increasingly used but there are limited data regarding this indication. We describe the experience of two UK congenital referral centres. DESIGN: Retrospective analysis of patients treated with endovascular aortic stent grafting for late pseudoaneurysms. SETTING: Two UK congenital heart centres, Bristol Heart Institute and Leeds General Infirmary. PATIENTS: 17 patients were treated 2006-2012. This represents all patients treated with this technique. MAIN OUTCOME MEASURES: Procedural and postprocedure success and complications. RESULTS: The average time from index repair to endovascular repair of pseudoaneurysm was 24.6 years. The majority (70.6%) had patch aortoplasty as the original surgical procedure and 41.2% were not under follow-up or discharged. Stent grafting procedural success rate was 100%. Median hospital stay postprocedure was 3 days. There was no procedural mortality or immediate complication. There were four minor early and three minor late complications. Imaging follow-up was available for an average of 31.6 months (range 6-65 months). All patients have demonstrated positive remodelling of the pseudoaneurysm with no incidence of continued expansion or stent graft failure up to 5 years following implant. CONCLUSIONS: Endovascular stent graft treatment of pseudoaneurysms show promising results in a population who have a high risk of surgical re-intervention. Complication rates appear to be low and recovery is quick. Longer-term data remain essential to scrutinise stent graft performance in this situation.


Asunto(s)
Aneurisma Falso/etiología , Coartación Aórtica/complicaciones , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Stents , Adulto , Anciano , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/cirugía , Coartación Aórtica/diagnóstico por imagen , Coartación Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Trasplantes , Resultado del Tratamiento , Reino Unido
5.
Circulation ; 123(9): 951-60, 2011 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-21339482

RESUMEN

BACKGROUND: Permanent pacemaker (PPM) requirement is a recognized complication of transcatheter aortic valve implantation. We assessed the UK incidence of permanent pacing within 30 days of CoreValve implantation and formulated an anatomic and electrophysiological model. METHODS AND RESULTS: Data from 270 patients at 10 centers in the United Kingdom were examined. Twenty-five patients (8%) had preexisting PPMs; 2 patients had incomplete data. The remaining 243 were 81.3±6.7 years of age; 50.6% were male. QRS duration increased from 105±23 to 135±29 milliseconds (P<0.01). Left bundle-branch block incidence was 13% at baseline and 61% after the procedure (P<0.001). Eighty-one patients (33.3%) required a PPM within 30 days. Rates of pacing according to preexisting ECG abnormalities were as follows: right bundle-branch block, 65.2%; left bundle-branch block, 43.75%; normal QRS, 27.6%. Among patients who required PPM implantation, the median time to insertion was 4.0 days (interquartile range, 2.0 to 7.75 days). Multivariable analysis revealed that periprocedural atrioventricular block (odds ratio, 6.29; 95% confidence interval, 3.55 to 11.15), balloon predilatation (odds ratio, 2.68; 95% confidence interval, 2.00 to 3.47), use of the larger (29 mm) CoreValve prosthesis (odds ratio, 2.50; 95% confidence interval, 1.22 to 5.11), interventricular septum diameter (odds ratio, 1.18; 95% confidence interval, 1.10 to 3.06), and prolonged QRS duration (odds ratio, 3.45; 95% confidence interval, 1.61 to 7.40) were independently associated with the need for PPM. CONCLUSION: One third of patients undergoing a CoreValve transcatheter aortic valve implantation procedure require a PPM within 30 days. Periprocedural atrioventricular block, balloon predilatation, use of the larger CoreValve prosthesis, increased interventricular septum diameter and prolonged QRS duration were associated with the need for PPM.


Asunto(s)
Válvula Aórtica , Cateterismo Cardíaco/tendencias , Estimulación Cardíaca Artificial/tendencias , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Marcapaso Artificial/tendencias , Anciano , Anciano de 80 o más Años , Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/terapia , Cateterismo Cardíaco/métodos , Estimulación Cardíaca Artificial/métodos , Femenino , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Incidencia , Masculino , Estudios Retrospectivos , Reino Unido
6.
Tissue Antigens ; 70(6): 524-5, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17900285
7.
Tissue Antigens ; 70(6): 525-7, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17900286

RESUMEN

This report describes the discovery and characterization of the HLA-Cw*0517 allele.


Asunto(s)
Antígenos HLA-C/genética , Alelos , Secuencia de Aminoácidos , Sustitución de Aminoácidos , Secuencia de Bases , Humanos , Datos de Secuencia Molecular , Alineación de Secuencia
8.
Br J Anaesth ; 96(3): 303-9, 2006 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-16415314

RESUMEN

BACKGROUND: In 2000 the European Society of Cardiology and the American College of Cardiology published a consensus document revising the definition of myocardial infarction. The usefulness of this revised definition has been challenged. It has been suggested that, rather than any release of cardiac troponin being potentially diagnostic of myocardial infarction, a diagnostic threshold consistent with significant myocardial injury should be defined. METHODS: We studied 65 patients undergoing elective major vascular surgery to examine the relationship between the magnitude of cardiac troponin I (cTnI) and creatine kinase MB fraction (CK-MB) release and clinical signs or symptoms of myocardial injury. cTnI and CK-MB concentrations were measured preoperatively and on the first 4 postoperative days using the ACCESS assay (Beckmann). Patients were considered to have suffered a perioperative myocardial infarction if they had either symptoms or ECG changes consistent with this diagnosis, together with cTnI release. RESULTS: Peak postoperative cTnI concentrations above the lower detection limit of the ACCESS assay (0.06 microg litre(-1)) occurred in 26 patients. Eight of these patients displayed symptoms or ECG changes consistent with myocardial injury. A cTnI level greater than 0.68 microg litre(-1) was found to be consistent with the clinical diagnosis of myocardial infarction. The optimal cut-off for the diagnosis of MI using CK-MB was 40.4 microg litre(-1). CONCLUSIONS: These data suggest that further studies are required to define the optimal cardiac troponin diagnostic threshold for the diagnosis of myocardial infarction in the non-cardiac surgery population.


Asunto(s)
Infarto del Miocardio/diagnóstico , Troponina I/sangre , Procedimientos Quirúrgicos Vasculares/efectos adversos , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Forma MB de la Creatina-Quinasa/sangre , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Periodo Posoperatorio , Curva ROC
10.
Heart ; 88(6): 627-33, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12433896

RESUMEN

OBJECTIVE: To estimate the need for coronary revascularisation, by using an incidence of indications approach, among 45-84 year olds with stable angina, unstable angina, and acute myocardial infarction. DESIGN: Modelling exercise. Six key steps along the pathway of care from initial diagnosis in primary or secondary care to revascularisation were defined and the frequency of indications estimated using routine data from hospital admissions and data from studies in the general population, and primary and secondary care. SETTING AND PATIENTS: Mid-1998 population of England. INTERVENTION: Coronary revascularisation. MAIN OUTCOME MEASURE: Ability to benefit (need), defined by randomised trials, expert panel ratings from the ACRE (appropriateness of coronary revascularisation) study, or by informal consensus. RESULTS: The need for coronary revascularisation was estimated to be 92 000 procedures, equivalent to a rate of 1861 per million population. Overall, the model of need exceeded current provision by 3.3:1, although among people aged 75 years and over the ratio was 7.7:1. A plausible upper estimate of need--obtained by assuming that 90% of patients with stable angina were referred from primary care and that angiography would be performed in 65% of patients with acute myocardial infarction and 75% of patients with unstable angina--was 2626 per million population. CONCLUSIONS: The national target of 1500 revascularisation procedures per million population is credibly related to population need, although upper estimates of need are considerably higher. Better understanding is required of the benefits of referring patients with specific indications from primary care. The greatest relative increase in provision is required for those aged 75 and older, among whom trial evidence of benefit is scant.


Asunto(s)
Angina de Pecho/cirugía , Infarto del Miocardio/cirugía , Revascularización Miocárdica/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Angina de Pecho/epidemiología , Angina Inestable/epidemiología , Angina Inestable/cirugía , Enfermedad Crónica , Inglaterra/epidemiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Modelos Teóricos , Infarto del Miocardio/epidemiología , Evaluación de Necesidades , Admisión del Paciente/estadística & datos numéricos , Derivación y Consulta/estadística & datos numéricos , Sensibilidad y Especificidad
11.
Eur Heart J ; 23(21): 1714-25, 2002 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-12398830

RESUMEN

AIMS: A new generation of multidetector-row CT (MDCT) scanners allows complete coronary coverage using retrospective ECG gating and 1mm slices. The purpose of this study was to investigate the potential of high resolution MDCT angiography with retrospective gating for detection of coronary artery stenoses. METHODS AND RESULTS: A total of 102 patients underwent both conventional and MDCT coronary angiography. After intravenous injection of a non-ionic contrast medium the entire heart was scanned within a single breath hold using 1mm slices. All MDCT data sets were reconstructed with retrospective gating at 20% to 80% in increments of 10% relative to the cardiac cycle. Two blinded independent reviewers analysed image quality for segments 1-4 (right coronary artery), 5-8 (left main, left anterior descending), and 11, 12 (left circumflex). These segments were evaluated for the presence or absence of significant (>or=50%) stenoses. The results were compared with those of invasive coronary angiography in a blinded fashion. Overall sensitivity for the detection of significant stenoses (>or=50%) were 0.86 (reader 1) and 0.93 (reader 2), specificity 0.96 (reader 1) and 0.97 (reader 2), negative predictive value 0.98 (reader 1) and 0.99 (reader 2). CONCLUSIONS: High resolution MDCT angiography with retrospective gating permits the non-invasive detection of coronary artery stenoses with high accuracy if image quality is optimized for each of the three major coronary arteries.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Pronóstico , Reproducibilidad de los Resultados
12.
Heart ; 87(3): 205-9, 2002 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11847152

RESUMEN

BACKGROUND: With faster image acquisition times and thinner slice widths, multislice detector computed tomography (MSCT) allows visualisation of human coronary arteries with diagnostic image quality. In addition to conventional axial slices, virtual coronary angioscopies (VCA) can be reconstructed using MSCT datasets. OBJECTIVE: To evaluate the feasibility of reconstructing VCA and to determine the clinical value of this new application in detecting atherosclerotic coronary artery lesions. METHODS: Datasets obtained by contrast enhanced non-invasive coronary angiography using MSCT (Somatom VZ) were analysed from 14 consecutive patients. VCA were simulated in 14 coronary arteries (left anterior descending, n = 7; right coronary, n = 7). Lesion detection was undertaken on conventional contrast enhanced axial slices, as well as by VCA. Intracoronary ultrasound (ICUS) was used as the gold standard for in vivo plaque detection. RESULTS: 38 lesions were detected both on ICUS and on axial slices: 14 severe target lesions of > 75% area stenosis (11 calcified, three non-calcified), and 24 intermediate lesions of < or = 75% area stenosis (seven calcified, 17 non-calcified). Using VCA, all severe lesions (n = 14) and all calcified intermediate plaques (n = 7) could clearly be identified. However, non-calcified intermediate lesions (n = 17) could not be accurately distinguished from the vessel wall; they were recognised as vessel wall alterations without significant luminal narrowing. CONCLUSIONS: Current MSCT technology allows reconstruction of VCA with good image quality. Despite a more anatomical view of heart and coronary vessels on three dimensional reconstruction, conventional axial slices were found to be superior for detecting coronary lesions. Thus further technical innovations are required before VCA can become a useful technique in clinical cardiology.


Asunto(s)
Angina de Pecho/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Simulación por Computador/normas , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Diagnóstico por Computador , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Interpretación de Imagen Radiográfica Asistida por Computador , Sensibilidad y Especificidad , Ultrasonografía
14.
J Comput Assist Tomogr ; 25(6): 900-6, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11711803

RESUMEN

PURPOSE: Clinical studies indicate that coronary plaque morphology might be differentiated noninvasively using multislice CT by determining tissue density within the lesions. The aim of the present experimental study was to evaluate factors that influence density measurements within small vessels. METHOD: A coronary phantom model was developed, consisting of silicon tubes (lumen diameter 4 mm) with two plaques of known density inside, simulating soft and intermediate lesions (Plaque 1: -39 HU; Plaque 2: 72 HU). Density measurement were conducted in three different contrast medium concentrations (1:30, 1:40, 1:50) and two different slice widths (4 x 2.5 mm, 4 x 1 mm). All scans were performed on a Somatom Volume Zoom (Siemens, Forchheim, Germany). Experimental results were compared with calculated data based on computer simulation. RESULTS: The two plaques could be clearly differentiated from each other on both collimations (4 x 2.5 mm: Plaque 1, 85 +/- 61 HU vs. Plaque 2, 119 +/- 26 HU, p < 0.0001; 4 x 1 mm: Plaque 1, 50 +/- 54 HU vs. Plaque 2, 91 +/- 17 HU, p < 0.0001). Significantly lower and more accurate results were achieved with 1.0 mm collimation (p < 0.0001). Contrast medium concentration contributed significantly to the measurements (p < 0.001). The experimental findings were confirmed by computer simulation, which revealed even more accurate results when using a 0.5 mm collimation (Plaque 1, 0.5 mm: -9 HU vs. 4 x 1 mm: 14 HU, Plaque 2, 4 x 0.5 mm: 83 HU vs. 4 x 1 mm: 93 HU). CONCLUSION: Density measurements were found to be highly dependent on slice width and surrounding contrast enhancement. Our results indicate that standardization of methodology is required before the noninvasive differentiation of human plaque morphology by multislice CT can be applied in the clinical setting as a screening test for coronary soft plaques.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Análisis de Varianza , Simulación por Computador , Medios de Contraste , Enfermedad de la Arteria Coronaria/patología , Humanos , Fantasmas de Imagen , Estadísticas no Paramétricas
15.
Eur Radiol ; 11(9): 1607-11, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-11511879

RESUMEN

The reliable non-invasive detection of coronary artery disease (CAD) is a prime goal for future developments in clinical cardiology. In addition to the documentation of high-grade stenoses, the detection of vulnerable plaques is of major importance for risk stratification and early treatment to prevent plaque rupture. Recently, a new generation of fast spiral CT has been introduced using a multi-slice technique (MSCT), which is the first real quantum leap in CT since the introduction of spiral CT in the early 1990s. We report on non-invasive differentiation of coronary plaque morphology by MSCT in patients with lesions in the proximal left anterior descending artery (LAD). The results were compared with the findings of intracoronary ultrasound (ICUS). The ICUS and MSCT scans were analysed in 6 patients scheduled for ICUS-guided PTCA. One target lesion was selected in each patient. On ICUS, two lesions were classified as soft, two as intermediate and two as calcified according to established criteria based on echogenicity. By multislice CT, density measurements (expressed in Hounsfield Units, HU) were performed at 16 randomly selected areas within the plaques. The two soft plaques showed a mean density of 6+/-28 and -5+/-25 HU, the two intermediate plaques of 83+/-17 and 51+/-19 HU, and the two calcified plaques of 489+/-372 and 423+/-111 HU. To our knowledge, this is the first report on non-invasive characterisation of coronary lesions by MSCT. Plaque composition could be clearly differentiated and classified according to the ICUS results by determining tissue density within the lesions. Thus, this new technology holds promise for non-invasive risk assessment in patients with known or suspected CAD since also rupture-prone soft coronary lesions can be detected by use of this new technique.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Tomografía Computarizada por Rayos X , Ultrasonografía Intervencional , Anciano , Angina de Pecho/diagnóstico , Angina de Pecho/patología , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas
16.
Catheter Cardiovasc Interv ; 53(4): 562-8, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11515014

RESUMEN

Paclitaxel is a new cancer chemotherapeutic agent that has been approved for clinical use in patients with a variety of different cancers. Paclitaxel inhibits cell proliferation by an action on microtubules. The aim of this study was to evaluate the safety and efficacy of locally delivered paclitaxel after coronary stent implantation. A novel double-balloon perfusion catheter was used to deliver the drug locally in the pig coronary artery. Twenty-seven domestic pigs underwent stent implantation of the left anterior descending artery. In the treatment group (n = 11), paclitaxel (10 ml; 10 micromol/l) was delivered using the double-balloon perfusion catheter prior to stent implantation. The control group received stent implantation only (n = 16). The animals were sacrificed 4 weeks later. Vessels were perfusion-fixed and morphometric analysis was performed using conventional techniques. In addition, the extent of injury was determined at each stent-strut area. Correlation of local injury and neointimal thickness was evaluated by linear regression. Neointimal thickness (paclitaxel 1.0 +/- 0.4 vs. control 0.7 +/- 0.3 mm), neointimal area (paclitaxel 4.1 +/- 2.2 vs. control 2.4 +/- 1.1 mm(2)), and the lumen area (paclitaxel 2.1 +/- 1.9 vs. control 2.5 +/- 0.9 mm(2)) did not show significant differences between both groups. Medial area (3.3 +/- 2.3 vs. 1.6 +/- 0.4 mm(2)) was larger in the vessels treated with paclitaxel (P < 0.05). Linear regression failed to show any difference in the response to injury between the two groups. Local delivery of paclitaxel with the double-balloon-perfusion catheter did not reduce neointima formation following stent implantation in native pig coronary arteries.


Asunto(s)
Angioplastia de Balón , Antineoplásicos Fitogénicos/administración & dosificación , Cateterismo , Vasos Coronarios/efectos de los fármacos , Vasos Coronarios/cirugía , Sistemas de Liberación de Medicamentos/métodos , Bombas de Infusión , Paclitaxel/administración & dosificación , Stents , Animales , Vasos Coronarios/patología , Modelos Animales de Enfermedad , Electrocardiografía/efectos de los fármacos , Porcinos
17.
Catheter Cardiovasc Interv ; 53(3): 352-8, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11458413

RESUMEN

The reliable noninvasive assessment of coronary artery disease would constitute an important step forward in clinical cardiology. The aim of the New Age pilot trial was to evaluate the diagnostic accuracy of multislice computed tomography (MSCT) in determining coronary lesions. As a gold standard for in vivo plaque detection, intracoronary ultrasound (ICUS) was used. Forty plaques were detected by ICUS in 15 target vessels (LAD, n = 8; RCA, n = 7) in patients assigned for ICUS-guided PTCA. Preinterventional MSCT was performed in all patients and the results were compared to ICUS with regard to lesion detection and quantification. According to ICUS results, the 40 plaques were divided into three groups: group I, mild lesions < 50% (n = 14; 44.36% +/- 5.77%); group II, intermediate lesions 50%-75% (n = 12; 59.18% +/- 9.39%); and group III, severe lesions > 75% (n = 14; 91.47% +/- 3.68%). All MSCT scans showed sufficient image quality for analysis. Thirty of 40 (75%) plaques were detected by MSCT in a first blinded session. After unblinding the ICUS results, the remaining 10 (25%) plaques could be identified. Lesion severity was classified correctly in 34 of 40 (85%) plaques. Plaque calcifications were diagnosed correctly in 16 of 19 (84.2%) plaques. Quantification of vessel size revealed a good correlation to the ICUS results (r(2) 0.68; P = 0.004). Noninvasive MSCT angiography showed good diagnostic accuracy with regard to lesion detection and quantification of vessel size. The overall good image quality, makes this new technology a promising modality, which might become an alternative diagnostic approach in patients with known or suspected coronary artery disease. Cathet Cardiovasc Intervent 2001;53:352-358.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Ultrasonografía
18.
Circulation ; 104(4): 480-5, 2001 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-11468213

RESUMEN

BACKGROUND: Intraluminal beta-irradiation has been shown to decrease neointimal proliferation after angioplasty in experimental models. The purpose of this study was to test the technical feasibility and biological effects of (186)Re-labeled stents. METHODS AND RESULTS: Thirty-four New Zealand White rabbits were fed a 0.5% cholesterol diet before balloon angioplasty and insertion of Palmaz stents in the infrarenal aorta. The animals were killed 7 weeks after stent implantation. Two of 34 animals died prematurely (aortic leak, pneumonia). Control stents (n=7) were compared with (186)Re stents (2.6 MBq [n=6], 8.1 MBq [n=5], 16.0 MBq [n=6], and 25.3 MBq [n=8]). Stent application was successful in all cases. No thrombus occlusion was observed. After 7 weeks, neointima formation was 2.2+/-0.2 mm(2) in the control group. In the treatment groups, a dose-dependent neointima reduction was detectable (0.5+/-0.5 mm(2) [2.6 MBq], 0.4+/-0.4 mm(2) [8.1 MBq], and 0 mm(2) [16.0 MBq, 25.3 MBq]). No induction of neointimal formation was observed at the edges of the stents. Radiation resulted in delayed reendothelialization. CONCLUSIONS: (186)Re stents were capable of reducing neointima formation in a dose-dependent fashion. (186)Re stents did not cause late thrombosis or neointimal induction at the stent margins in the observation period of 7 weeks.


Asunto(s)
Arteriopatías Oclusivas/prevención & control , Radioisótopos/uso terapéutico , Renio/uso terapéutico , Stents , Animales , Aorta Abdominal/patología , Aorta Abdominal/efectos de la radiación , Aorta Abdominal/cirugía , Braquiterapia/métodos , Modelos Animales de Enfermedad , Relación Dosis-Respuesta en la Radiación , Endotelio Vascular/patología , Endotelio Vascular/efectos de la radiación , Fibrina/metabolismo , Semivida , Masculino , Conejos , Factores de Tiempo , Túnica Íntima/metabolismo , Túnica Íntima/patología , Túnica Íntima/efectos de la radiación , Túnica Media/metabolismo , Túnica Media/patología , Túnica Media/efectos de la radiación
19.
Clin Radiol ; 56(6): 466-74, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11428796

RESUMEN

AIM: To evaluate the accuracy of non-invasive measurements within coronary arteries by multi-slice computed tomography (MSCT). We present experimental as well as clinical data. MATERIALS AND METHODS: Silicon tubes simulating coronary arteries (outer diameter 6 mm, lumen diameter within stenotic area 2 mm) were used for experimental studies. Clinical data were derived from 15 patients in whom vessel diameters were assessed by MSCT, intracoronary ultrasound (ICUS) and quantitative coronary angiography (QCA). MSCT were performed in a Somatom Volume Zoom(trade mark)CT system (Siemens, Forchheim, Germany) at 2 collimated slice widths (2.5 mm, 1.0 mm). RESULTS: Outer silicon tube diameters were overestimated by MSCT (6.56 mm +/- 0.32 mm). All measurements revealed significantly better results on 1.0 collimation compared to 2.5 mm collimation (outer diameter: 6.36 mm +/- 0.22 mm vs 6.76 mm +/- 0.27 mm, P < 0.0001; lumen diameters: 1.83 mm +/- 0.14 mm vs 1.51 mm +/- 0.19 mm, P < 0.0001). The comparison of vessel diameters within human coronary arteries revealed comparable results between ICUS and MSCT (4.89 mm +/- 0.67 mm vs 4.91 mm +/- 0.71 mm, P = 0.79, r = 0.79, P < 0.0001). QCA-measurements showed significantly lower results (3.67 +/- 0.71, P < 0.0001, r = 0.62, P < 0.001). CONCLUSIONS: Experimental as well as initial clinical results indicate acceptable reliability and accuracy of quantitative measurements by MSCT, when using thin collimated slice widths. Partial volume effects lead to a systematic overestimation of vessel size. MSCT has the potential to become an important non-invasive diagnostic tool in patients with coronary artery disease.


Asunto(s)
Angiografía Coronaria/normas , Tomografía Computarizada por Rayos X/normas , Angiografía Coronaria/instrumentación , Angiografía Coronaria/métodos , Humanos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos
20.
J Invasive Cardiol ; 13(6): 456-9, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11385170

RESUMEN

PURPOSE: To assess the feasibility and initial clinical results of Closer (Perclose, Redwood City, California), a new device for percutaneous suture-mediated closure of arterial puncture sites. METHODS: Vascular interventions were performed using 6 and 7 French sheaths in 22 consecutive patients. All patients underwent suture-mediated percutaneous closure with the new device. Patients were followed by physical examination the day after the procedure. RESULTS: Immediate hemostasis was achieved in 20/22 patients (91%). In 3 out of 5 antegrade closures, only one suture was captured. In two cases, this was managed by reinsertion of a second device. In another patient, hemostasis was not achieved by the device due to knot entrapment. No major complications were observed. The overall rate of minor complications was 9% (2/22) due to hematomas without the need for blood transfusions. CONCLUSION: Percutaneous suture with this new device is an acceptably safe and effective method to achieve immediate hemostasis of the arterial access site after interventional procedures with minimized manipulation of the puncture track.


Asunto(s)
Arterias/cirugía , Agujas/estadística & datos numéricos , Punciones/instrumentación , Suturas , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Hemostasis/fisiología , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...