1.
J Appl Physiol (1985) ; 116(7): 790-6, 2014 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-24436299

RESUMEN

Using dual-frequency ultrasound (DFU), microbubbles (<10 µm diameter) have been detected in tissue following decompression. It is not known if these microbubbles are the precursors for B-mode ultrasound-detectable venous gas emboli (bmdVGE). The purpose of this study was to determine if microbubbles could be detected intravascularly postdecompression and to investigate the temporal relationship between microbubbles and larger bmdVGE. Anesthetized swine (n = 15) were exposed to 4.0-4.5 ATA for 2 h, followed by decompression to 0.98 ATA. Microbubble presence and VGE grade were measured using DFU and B-mode ultrasound, respectively, before and for 1 h postdecompression, approximately every 4-5 min. Microbubbles appeared in the bloodstream postdecompression, both in the presence and absence of bmdVGE. In swine without bmdVGE, microbubbles remained elevated for the entire 60-min postdecompression period. In swine with bmdVGE, microbubble signals were detected initially but then returned to baseline. Microbubbles were not detected with the sham dive. Mean bmdVGE grade increased over the length of the postdecompression data collection period. Comparison of the two response curves revealed significant differences at 5 and 10 min postdecompression, indicating that microbubbles preceded bmdVGE. These findings indicate that decompression-induced microbubbles can 1) be detected intravascularly at multiple sites, 2) appear in the presence and absence of bmdVGE, and 3) occur before bmdVGE. This supports the hypothesis that microbubbles precede larger VGE bubbles. Microbubble presence may be an early marker of decompression stress. Since DFU is a low-power ultrasonic method, it may be useful for operational diving applications.


Asunto(s)
Enfermedad de Descompresión/diagnóstico por imagen , Embolia Aérea/diagnóstico por imagen , Microburbujas , Animales , Medios de Contraste , Enfermedad de Descompresión/sangre , Modelos Animales de Enfermedad , Diagnóstico Precoz , Embolia Aérea/sangre , Fluorocarburos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Porcinos , Factores de Tiempo , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...