Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Biochem Pharmacol ; : 116175, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38552850

RESUMEN

Acid-sensing ion channel 1a (ASIC1a) is a proton-gated channel involved in synaptic transmission, pain signalling, and several ischemia-associated pathological conditions. The spider venom-derived peptides PcTx1 and Hi1a are two of the most potent ASIC1a inhibitors known and have been instrumental in furthering our understanding of the structure, function, and biological roles of ASICs. To date, homologous spider peptides with different pharmacological profiles at ASIC1a have yet to be discovered. Here we report the characterisation of Hc3a, a single inhibitor cystine knot peptide from the Australian funnel-web spider Hadronyche cerberea with sequence similarity to PcTx1. We show that Hc3a has complex pharmacology and binds different ASIC1a conformational states (closed, open, and desensitised) with different affinities, with the most prominent effect on desensitisation. Hc3a slows the desensitisation kinetics of proton-activated ASIC1a currents across multiple application pHs, and when bound directly to ASIC1a in the desensitised conformation promotes current inhibition. The solution structure of Hc3a was solved, and the peptide-channel interaction examined via mutagenesis studies to highlight how small differences in sequence between Hc3a and PcTx1 can lead to peptides with distinct pharmacology. The discovery of Hc3a expands the pharmacological diversity of spider venom peptides targeting ASIC1a and adds to the toolbox of compounds to study the intricacies of ASIC1 gating.

2.
Int J Mol Sci ; 25(3)2024 Jan 24.
Artículo en Inglés | MEDLINE | ID: mdl-38338693

RESUMEN

The Gárdos channel (KCNN4) and Piezo1 are the best-known ion channels in the red blood cell (RBC) membrane. Nevertheless, the quantitative electrophysiological behavior of RBCs and its heterogeneity are still not completely understood. Here, we use state-of-the-art biochemical methods to probe for the abundance of the channels in RBCs. Furthermore, we utilize automated patch clamp, based on planar chips, to compare the activity of the two channels in reticulocytes and mature RBCs. In addition to this characterization, we performed membrane potential measurements to demonstrate the effect of channel activity and interplay on the RBC properties. Both the Gárdos channel and Piezo1, albeit their average copy number of activatable channels per cell is in the single-digit range, can be detected through transcriptome analysis of reticulocytes. Proteomics analysis of reticulocytes and mature RBCs could only detect Piezo1 but not the Gárdos channel. Furthermore, they can be reliably measured in the whole-cell configuration of the patch clamp method. While for the Gárdos channel, the activity in terms of ion currents is higher in reticulocytes compared to mature RBCs, for Piezo1, the tendency is the opposite. While the interplay between Piezo1 and Gárdos channel cannot be followed using the patch clamp measurements, it could be proved based on membrane potential measurements in populations of intact RBCs. We discuss the Gárdos channel and Piezo1 abundance, interdependencies and interactions in the context of their proposed physiological and pathophysiological functions, which are the passing of small constrictions, e.g., in the spleen, and their active participation in blood clot formation and thrombosis.


Asunto(s)
Eritrocitos , Canales de Potasio de Conductancia Intermedia Activados por el Calcio , Reticulocitos , Transporte Biológico , Calcio/metabolismo , Eritrocitos/metabolismo , Reticulocitos/metabolismo , Humanos , Canales de Potasio de Conductancia Intermedia Activados por el Calcio/metabolismo , Canales Iónicos/metabolismo
4.
J Gen Physiol ; 155(12)2023 12 04.
Artículo en Inglés | MEDLINE | ID: mdl-37801066

RESUMEN

PIEZO1 channels are mechanically activated cation channels that play a pivotal role in sensing mechanical forces in various cell types. Their dysfunction has been associated with numerous pathophysiological states, including generalized lymphatic dysplasia, varicose vein disease, and hereditary xerocytosis. Given their physiological relevance, investigating PIEZO1 is crucial for the pharmaceutical industry, which requires scalable techniques to allow for drug discovery. In this regard, several studies have used high-throughput automated patch clamp (APC) combined with Yoda1, a specific gating modifier of PIEZO1 channels, to explore the function and properties of PIEZO1 in heterologous expression systems, as well as in primary cells. However, a combination of solely mechanical stimulation (M-Stim) and high-throughput APC has not yet been available for the study of PIEZO1 channels. Here, we show that optimization of pipetting parameters of the SyncroPatch 384 coupled with multihole NPC-384 chips enables M-Stim of PIEZO1 channels in high-throughput electrophysiology. We used this approach to explore differences between the response of mouse and human PIEZO1 channels to mechanical and/or chemical stimuli. Our results suggest that applying solutions on top of the cells at elevated pipetting flows is crucial for activating PIEZO1 channels by M-Stim on the SyncroPatch 384. The possibility of comparing and combining mechanical and chemical stimulation in a high-throughput patch clamp assay facilitates investigations on PIEZO1 channels and thereby provides an important experimental tool for drug development.


Asunto(s)
Canales Iónicos , Mecanotransducción Celular , Humanos , Canales Iónicos/metabolismo , Mecanotransducción Celular/fisiología , Ensayos Analíticos de Alto Rendimiento , Electrofisiología
5.
Br J Pharmacol ; 180(16): 2039-2063, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36457143

RESUMEN

BACKGROUND AND PURPOSE: The protein PIEZO1 forms mechanically activated, calcium-permeable, non-selective cation channels in numerous cell types from several species. Options for pharmacological modulation are limited and so we modified a small-molecule agonist at PIEZO1 channels (Yoda1) to increase the ability to modulate these channels. EXPERIMENTAL APPROACH: Medicinal chemistry generated Yoda1 analogues that were tested in intracellular calcium and patch-clamp assays on cultured cells exogenously expressing human or mouse PIEZO1 or mouse PIEZO2. Physicochemical assays and wire myography assays on veins from mice with genetic disruption of PIEZO1. KEY RESULTS: A Yoda1 analogue (KC159) containing 4-benzoic acid instead of the pyrazine of Yoda1 and its potassium salt (KC289) have equivalent or improved reliability, efficacy and potency, compared with Yoda1 in functional assays. Tested against overexpressed mouse PIEZO1 in calcium assays, the order of potency (as EC50 values, nM) was KC289, 150 > KC159 280 > Yoda1, 600). These compounds were selective for PIEZO1 over other membrane proteins, and the physicochemical properties were more suited to physiological conditions than those of Yoda1. The vasorelaxant effects were consistent with PIEZO1 agonism. In contrast, substitution with 2-benzoic acid failed to generate a modulator. CONCLUSION AND IMPLICATIONS: 4-Benzoic acid modification of Yoda1 improves PIEZO1 agonist activity at PIEZO1 channels. We suggest naming this new modulator Yoda2. It should be a useful tool compound in physiological assays and facilitate efforts to identify a binding site. Such compounds may have therapeutic potential, for example, in diseases linked genetically to PIEZO1 such as lymphatic dysplasia.


Asunto(s)
Calcio , Mecanotransducción Celular , Ratones , Humanos , Animales , Calcio/metabolismo , Reproducibilidad de los Resultados , Mecanotransducción Celular/fisiología , Sitios de Unión , Canales de Calcio/metabolismo , Canales Iónicos/metabolismo
6.
Blood ; 141(2): 135-146, 2023 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-36122374

RESUMEN

Despite the identification of the high-incidence red cell antigen Era nearly 40 years ago, the molecular background of this antigen, together with the other 2 members of the Er blood group collection, has yet to be elucidated. Whole exome and Sanger sequencing of individuals with serologically defined Er alloantibodies identified several missense mutations within the PIEZO1 gene, encoding amino acid substitutions within the extracellular domain of the Piezo1 mechanosensor ion channel. Confirmation of Piezo1 as the carrier molecule for the Er blood group antigens was demonstrated using immunoprecipitation, CRISPR/Cas9-mediated gene knockout, and expression studies in an erythroblast cell line. We report the molecular bases of 5 Er blood group antigens: the recognized Era, Erb, and Er3 antigens and 2 novel high-incidence Er antigens, described here as Er4 and Er5, establishing a new blood group system. Anti-Er4 and anti-Er5 are implicated in severe hemolytic disease of the fetus and newborn. Demonstration of Piezo1, present at just a few hundred copies on the surface of the red blood cell, as the site of a new blood group system highlights the potential antigenicity of even low-abundance membrane proteins and contributes to our understanding of the in vivo characteristics of this important and widely studied protein in transfusion biology and beyond.


Asunto(s)
Anemia Hemolítica Congénita , Antígenos de Grupos Sanguíneos , Recién Nacido , Humanos , Mutación Missense , Anemia Hemolítica Congénita/genética , Eritrocitos/metabolismo , Canales Iónicos/química , Antígenos de Grupos Sanguíneos/metabolismo , Mecanotransducción Celular
7.
Front Mol Neurosci ; 15: 982689, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36340694

RESUMEN

Human acid-sensing ion channels (ASIC) are ligand-gated ionotropic receptors expressed widely in peripheral tissues as well as sensory and central neurons and implicated in detection of inflammation, tissue injury, and hypoxia-induced acidosis. This makes ASIC channels promising targets for drug discovery in oncology, pain and ischemia, and several modulators have progressed into clinical trials. We describe the use of hASIC1a as a case study for the development and validation of low, medium and high throughput automated patch clamp (APC) assays suitable for the screening and mechanistic profiling of new ligands for this important class of ligand-gated ion channel. Initial efforts to expand on previous manual patch work describing an endogenous hASIC1a response in HEK cells were thwarted by low current expression and unusual pharmacology, so subsequent work utilized stable hASIC1a CHO cell lines. Ligand-gated application protocols and screening assays on the Patchliner, QPatch 48, and SyncroPatch 384 were optimized and validated based on pH activation and nM-µM potency of reference antagonists (e.g., Amiloride, Benzamil, Memantine, Mambalgin-3, A-317567, PcTx1). By optimizing single and stacked pipette tip applications available on each APC platform, stable pH-evoked currents during multiple ligand applications enabled cumulative EC50 and IC50 determinations with minimized receptor desensitization. Finally, we successfully demonstrated for the first time on an APC platform the ability to use current clamp to implement the historical technique of input resistance tracking to measure ligand-gated changes in membrane conductance on the Patchliner platform.

8.
Commun Biol ; 5(1): 969, 2022 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-36109584

RESUMEN

Crucial conventional patch-clamp approaches to investigate cellular electrophysiology suffer from low-throughput and require considerable experimenter expertise. Automated patch-clamp (APC) approaches are more experimenter independent and offer high-throughput, but by design are predominantly limited to assays containing small, homogenous cells. In order to enable high-throughput APC assays on larger cells such as native cardiomyocytes isolated from mammalian hearts, we employed a fixed-well APC plate format. A broad range of detailed electrophysiological parameters including action potential, L-type calcium current and basal inward rectifier current were reliably acquired from isolated swine atrial and ventricular cardiomyocytes using APC. Effective pharmacological modulation also indicated that this technique is applicable for drug screening using native cardiomyocyte material. Furthermore, sequential acquisition of multiple parameters from a single cell was successful in a high throughput format, substantially increasing data richness and quantity per experimental run. When appropriately expanded, these protocols will provide a foundation for effective mechanistic and phenotyping studies of human cardiac electrophysiology. Utilizing scarce biopsy samples, regular high throughput characterization of primary cardiomyocytes using APC will facilitate drug development initiatives and personalized treatment strategies for a multitude of cardiac diseases.


Asunto(s)
Calcio , Miocitos Cardíacos , Animales , Fenómenos Electrofisiológicos , Electrofisiología , Humanos , Mamíferos , Técnicas de Placa-Clamp , Porcinos
10.
J Physiol ; 600(2): 277-297, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34555195

RESUMEN

Although automated patch clamp (APC) devices have been around for many years and have become an integral part of many aspects of drug discovery, high throughput instruments with gigaohm seal data quality are relatively new. Experiments where a large number of compounds are screened against ion channels are ideally suited to high throughput APC, particularly when the amount of compound available is low. Here we evaluate different APC approaches using a variety of ion channels and screening settings. We have performed a screen of 1920 compounds on GluN1/GluN2A NMDA receptors for negative allosteric modulation using both the SyncroPatch 384 and FLIPR. Additionally, we tested the effect of 36 arthropod venoms on NaV 1.9 using a single 384-well plate on the SyncroPatch 384. As an example for mutant screening, a range of acid-sensing ion channel variants were tested and the success rate increased through fluorescence-activated cell sorting (FACS) prior to APC experiments. Gigaohm seal data quality makes the 384-format accessible to recording of primary and stem cell-derived cells on the SyncroPatch 384. We show recordings in voltage and current clamp modes of stem cell-derived cardiomyocytes. In addition, the option of intracellular solution exchange enabled investigations into the effects of intracellular Ca2+ and cAMP on TRPC5 and HCN2 currents, respectively. Together, these data highlight the broad applicability and versatility of APC platforms and also outlines some limitations of the approach. KEY POINTS: High throughput automated patch clamp (APC) can be used for a variety of applications involving ion channels. Lower false positive rates were achieved using automated patch clamp versus a fluorometric imaging plate reader (FLIPR) in a high throughput compound screen against NMDA receptors.  Genetic variants and mutations can be screened on a single 384-well plate to reduce variability of experimental parameters. Intracellular solution can be perfused to investigate effects of ions and second messenger systems without the need for excised patches. Primary cells and stem cell-derived cells can be used on high throughput APC with reasonable success rates for cell capture, voltage clamp measurements and action potential recordings in current clamp mode.


Asunto(s)
Descubrimiento de Drogas , Ensayos Analíticos de Alto Rendimiento , Canales Iónicos , Miocitos Cardíacos , Técnicas de Placa-Clamp
11.
J Pharmacol Toxicol Methods ; 112: 107125, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34500078

RESUMEN

INTRODUCTION: For reliable identification of cardiac safety risk, compounds should be screened for activity on cardiac ion channels in addition to hERG, including NaV1.5 and CaV1.2. We identified different parameters that might affect IC50s of compounds on NaV1.5 peak and late currents recorded using automated patch clamp (APC) and suggest outlines for best practices. METHODS: APC instruments SyncroPatch 384 and Patchliner were used to record NaV1.5 peak and late current. Up to 24 CiPA compounds were used to investigate effects of voltage protocol, holding potential (-80 mV or - 95 mV) and temperature (23 ± 1 °C or 36 ± 1 °C) on IC50 values on hNaV1.5 overexpressed in HEK or CHO cells either as frozen cells or running cultures. RESULTS: The IC50s of 18 compounds on the NaV1.5 peak current recorded on the SyncroPatch 384 using the CiPA step-ramp protocol correlated well with the literature. The use of frozen or cultured cells did not affect IC50s but voltage protocol and holding potential did cause differences in IC50 values. Temperature can affect Vhalf of inactivation and also compound potency. A compound incubation time of 5-6 min was sufficient for most compounds, however slow acting compounds such as terfenadine required longer to reach maximum effect. DISCUSSION: We conclude that holding potential, voltage protocol and temperature can affect IC50 values and recommend the use of the CiPA step-ramp protocol at physiological temperature to record NaV1.5 peak and late currents for cardiac safety. Further recommendations include: a minimum compound incubation time of 5 min, a replicate number of 4 and the use of positive and negative controls for reliable IC50s.


Asunto(s)
Trastorno del Sistema de Conducción Cardíaco , Descubrimiento de Drogas , Ensayos Analíticos de Alto Rendimiento , Animales , Células CHO , Trastorno del Sistema de Conducción Cardíaco/diagnóstico , Cricetinae , Cricetulus , Canal de Sodio Activado por Voltaje NAV1.5 , Técnicas de Placa-Clamp
12.
Cells ; 11(1)2021 12 24.
Artículo en Inglés | MEDLINE | ID: mdl-35011611

RESUMEN

Over 95% of Polycythemia Vera (PV) patients carry the V617F mutation in the tyrosine kinase Janus kinase 2 (JAK2), resulting in uncontrolled erythroid proliferation and a high risk of thrombosis. Using mass spectrometry, we analyzed the RBC membrane proteome and showed elevated levels of multiple Ca2+ binding proteins as well as endoplasmic-reticulum-residing proteins in PV RBC membranes compared with RBC membranes from healthy individuals. In this study, we investigated the impact of JAK2V617F on (1) calcium homeostasis and RBC ion channel activity and (2) protein expression and sorting during terminal erythroid differentiation. Our data from automated patch-clamp show modified calcium homeostasis in PV RBCs and cell lines expressing JAK2V617F, with a functional impact on the activity of the Gárdos channel that could contribute to cellular dehydration. We show that JAK2V617F could play a role in organelle retention during the enucleation step of erythroid differentiation, resulting in modified whole cell proteome in reticulocytes and RBCs in PV patients. Given the central role that calcium plays in the regulation of signaling pathways, our study opens new perspectives to exploring the relationship between JAK2V617F, calcium homeostasis, and cellular abnormalities in myeloproliferative neoplasms, including cellular interactions in the bloodstream in relation to thrombotic events.


Asunto(s)
Calcio/metabolismo , Eritrocitos/metabolismo , Eritropoyesis , Homeostasis , Orgánulos/metabolismo , Policitemia Vera/sangre , Policitemia Vera/metabolismo , Animales , Tamaño de la Célula , Eritroblastos/metabolismo , Células Eritroides/metabolismo , Células Eritroides/patología , Humanos , Canales de Potasio de Conductancia Intermedia Activados por el Calcio/metabolismo , Espacio Intracelular/metabolismo , Janus Quinasa 2/genética , Ratones Endogámicos C57BL , Mutación/genética , Proteoma/metabolismo , Reticulocitos/metabolismo , Ribosomas/metabolismo , Trombocitosis/sangre
13.
J Pharmacol Toxicol Methods ; 105: 106884, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32565325

RESUMEN

INTRODUCTION: Screening compounds for activity on the hERG channel using patch clamp is a crucial part of safety testing. Automated patch clamp (APC) is becoming widely accepted as an alternative to manual patch clamp in order to increase throughput whilst maintaining data quality. In order to standardize APC experiments, we have investigated the effects on IC50 values under different conditions using several devices across multiple sites. METHODS: APC instruments SyncroPatch 384i, SyncroPatch 384PE and Patchliner, were used to record hERG expressed in HEK or CHO cells. Up to 27 CiPA compounds were used to investigate effects of voltage protocol, incubation time, labware and time between compound preparation and experiment on IC50 values. RESULTS: All IC50 values of 21 compounds recorded on the SyncroPatch 384PE correlated well with IC50 values from the literature (Kramer et al., 2013) regardless of voltage protocol or labware, when compounds were used immediately after preparation, but potency of astemizole decreased if prepared in Teflon or polypropylene (PP) compound plates 2-3 h prior to experiments. Slow acting compounds such as dofetilide, astemizole, and terfenadine required extended incubation times of at least 6 min to reach steady state and therefore, stable IC50 values. DISCUSSION: Assessing the influence of different experimental conditions on hERG assay reliability, we conclude that either the step-ramp protocol recommended by CiPA or a standard 2-s step-pulse protocol can be used to record hERG; a minimum incubation time of 5 min should be used and although glass, Teflon, PP or polystyrene (PS) compound plates can be used for experiments, caution should be taken if using Teflon, PS or PP vessels as some adsorption can occur if experiments are not performed immediately after preparation. Our recommendations are not limited to the APC devices described in this report, but could also be extended to other APC devices.


Asunto(s)
Arritmias Cardíacas/tratamiento farmacológico , Benchmarking/métodos , Fármacos Cardiovasculares/farmacología , Descubrimiento de Drogas/métodos , Corazón/efectos de los fármacos , Técnicas de Placa-Clamp/métodos , Animales , Arritmias Cardíacas/metabolismo , Astemizol/farmacología , Células CHO , Calibración , Fármacos Cardiovasculares/química , Línea Celular , Cricetulus , Evaluación Preclínica de Medicamentos/métodos , Canal de Potasio ERG1/metabolismo , Células HEK293 , Humanos , Fenetilaminas/farmacología , Polipropilenos/química , Politetrafluoroetileno/química , Estándares de Referencia , Reproducibilidad de los Resultados , Sulfonamidas/farmacología , Terfenadina/farmacología
14.
J Pharmacol Toxicol Methods ; 105: 106890, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32574700

RESUMEN

INTRODUCTION: In response to the ongoing shift of the regulatory cardiac safety paradigm, a recent White Paper proposed general principles for developing and implementing proarrhythmia risk prediction models. These principles included development strategies to validate models, and implementation strategies to ensure a model developed by one lab can be used by other labs in a consistent manner in the presence of lab-to-lab experimental variability. While the development strategies were illustrated through the validation of the model under the Comprehensive In vitro Proarrhythmia Assay (CiPA), the implementation strategies have not been adopted yet. METHODS: The proposed implementation strategies were applied to the CiPA model by performing a sensitivity analysis to identify a subset of calibration drugs that were most critical in determining the classification thresholds for proarrhythmia risk prediction. RESULTS: The selected calibration drugs were able to recapitulate classification thresholds close to those calculated from the full list of CiPA drugs. Using an illustrative dataset it was shown that a new lab could use these calibration drugs to establish its own classification thresholds (lab-specific calibration), and verify that the model prediction accuracy in the new lab is comparable to that in the original lab where the model was developed (lab-specific validation). DISCUSSION: This work used the CiPA model as an example to illustrate how to adopt the proposed model implementation strategies to select calibration drugs and perform lab-specific calibration and lab-specific validation. Generic in nature, these strategies could be generally applied to different proarrhythmia risk prediction models using various experimental systems under the new paradigm.


Asunto(s)
Arritmias Cardíacas/inducido químicamente , Bioensayo/métodos , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/prevención & control , Miocitos Cardíacos/efectos de los fármacos , Preparaciones Farmacéuticas/administración & dosificación , Calibración , Evaluación Preclínica de Medicamentos/métodos , Electrocardiografía/métodos , Humanos
16.
Toxicol Appl Pharmacol ; 394: 114961, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32209365

RESUMEN

INTRODUCTION: hERG block potency is widely used to calculate a drug's safety margin against its torsadogenic potential. Previous studies are confounded by use of different patch clamp electrophysiology protocols and a lack of statistical quantification of experimental variability. Since the new cardiac safety paradigm being discussed by the International Council for Harmonisation promotes a tighter integration of nonclinical and clinical data for torsadogenic risk assessment, a more systematic approach to estimate the hERG block potency and safety margin is needed. METHODS: A cross-industry study was performed to collect hERG data on 28 drugs with known torsadogenic risk using a standardized experimental protocol. A Bayesian hierarchical modeling (BHM) approach was used to assess the hERG block potency of these drugs by quantifying both the inter-site and intra-site variability. A modeling and simulation study was also done to evaluate protocol-dependent changes in hERG potency estimates. RESULTS: A systematic approach to estimate hERG block potency is established. The impact of choosing a safety margin threshold on torsadogenic risk evaluation is explored based on the posterior distributions of hERG potency estimated by this method. The modeling and simulation results suggest any potency estimate is specific to the protocol used. DISCUSSION: This methodology can estimate hERG block potency specific to a given voltage protocol. The relationship between safety margin thresholds and torsadogenic risk predictivity suggests the threshold should be tailored to each specific context of use, and safety margin evaluation may need to be integrated with other information to form a more comprehensive risk assessment.


Asunto(s)
Canal de Potasio ERG1/antagonistas & inhibidores , Medición de Riesgo/métodos , Torsades de Pointes/inducido químicamente , Teorema de Bayes , Simulación por Computador , Humanos , Modelos Biológicos , Técnicas de Placa-Clamp , Bloqueadores de los Canales de Potasio/farmacología , Seguridad , Torsades de Pointes/fisiopatología
17.
Curr Protoc Pharmacol ; 88(1): e70, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31868992

RESUMEN

Current in vitro assays typically poorly predict cardiac liability as they focus on single ion channels overexpressed in cell lines. Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs), on the other hand, provide a unique opportunity for drug testing on human cardiomyocytes using high-throughput systems. However, these cells can differ from adult cardiomyocytes in their ion channel expression and, therefore, electrophysiologic properties. One of the main challenges of hiPSC-CMs is the physiologic expression of ion channels such as the inward rectifiers (e.g., Kir2.1-2.3), which conduct the cardiac inward rectifier potassium current (IK1 ). IK1 is one of the primary contributors in maintaining a stable resting membrane potential in cardiac cells, which is essential for excitability. This is only expressed in low levels, or sometimes not at all, in hiPSC-CMs as shown by patch clamp studies. Dynamic clamp is a method of electronically introducing ion currents (e.g., IK1 ) into cells to compensate for the lack of endogenous expression, thus offering the potential to record more stable action potentials in hiPSC-CMs. In this article, we describe the method of using hiPSC-CMs on an automated patch clamp device (Patchliner) coupled with the automated dynamic clamp add-on (Dynamite8 ). We describe protocols for optimized cell handling and harvesting for use on the Patchliner and the steps required for automated execution of experiments and data analysis in dynamic clamp mode. © 2019 by John Wiley & Sons, Inc. Basic Protocol: Recording action potential pharmacology from human induced pluripotent stem cell-derived cardiomyocytes in automated patch clamp combined with dynamic clamp to introduce simulated IK1 and compensate seal resistance Support Protocol 1: Cardiomyocyte plating and culture Support Protocol 2: Cell harvesting and dissociation Alternate Protocol: Recording action potential pharmacology at physiologic temperatures.


Asunto(s)
Células Madre Pluripotentes Inducidas/metabolismo , Canales Iónicos/metabolismo , Miocitos Cardíacos/metabolismo , Técnicas de Placa-Clamp/métodos , Potenciales de Acción/fisiología , Línea Celular , Humanos , Potenciales de la Membrana/fisiología
19.
Expert Opin Drug Discov ; 13(3): 269-277, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29343120

RESUMEN

INTRODUCTION: Automated patch clamp (APC) devices have become commonplace in many industrial and academic labs. Their ease-of-use and flexibility have ensured that users can perform routine screening experiments and complex kinetic experiments on the same device without the need for months of training and experience. APC devices are being developed to increase throughput and flexibility. Areas covered: Experimental options such as temperature control, internal solution exchange and current clamp have been available on some APC devices for some time, and are being introduced on other devices. A comprehensive review of the literature pertaining to these features for the Patchliner, QPatch and Qube and data for these features for the SyncroPatch 384/768PE, is given. In addition, novel features such as dynamic clamp on the Patchliner and light stimulation of action potentials using channelrhodosin-2 is discussed. Expert opinion: APC devices will continue to play an important role in drug discovery. The instruments will be continually developed to meet the needs of HTS laboratories and for basic research. The use of stem cells and recordings in current clamp mode will increase, as will the development of complex add-ons such as dynamic clamp and optical stimulation on high throughput devices.


Asunto(s)
Descubrimiento de Drogas/métodos , Ensayos Analíticos de Alto Rendimiento/métodos , Canales Iónicos/metabolismo , Animales , Diseño de Fármacos , Humanos , Técnicas de Placa-Clamp/métodos
20.
Front Physiol ; 8: 1094, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-29403387

RESUMEN

An important aspect of the Comprehensive In Vitro Proarrhythmia Assay (CiPA) proposal is the use of human stem cell-derived cardiomyocytes and the confirmation of their predictive power in drug safety assays. The benefits of this cell source are clear; drugs can be tested in vitro on human cardiomyocytes, with patient-specific genotypes if needed, and differentiation efficiencies are generally excellent, resulting in a virtually limitless supply of cardiomyocytes. There are, however, several challenges that will have to be surmounted before successful establishment of hSC-CMs as an all-round predictive model for drug safety assays. An important factor is the relative electrophysiological immaturity of hSC-CMs, which limits arrhythmic responses to unsafe drugs that are pro-arrhythmic in humans. Potentially, immaturity may be improved functionally by creation of hybrid models, in which the dynamic clamp technique joins simulations of lacking cardiac ion channels (e.g., IK1) with hSC-CMs in real-time during patch clamp experiments. This approach has been used successfully in manual patch clamp experiments, but throughput is low. In this study, we combined dynamic clamp with automated patch clamp of iPSC-CMs in current clamp mode, and demonstrate that IK1 conductance can be added to iPSC-CMs on an automated patch clamp platform, resulting in an improved electrophysiological maturity.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...