Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Cardiovasc Comput Tomogr ; 16(5): 423-430, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35637128

RESUMEN

BACKGROUND: Computed tomography (CT) imaging is the standard of care before transcatheter aortic valve replacement (TAVR). The aortic annulus undergoes conformational changes during the heart cycle. Therefore, the image acquisition time point can impact prosthesis sizing and fit. Clinical outcome data are lacking. The aim of this study was to compare systolic and diastolic cardiac CT data acquisition with regard to procedural and clinical outcomes in patients undergoing TAVR for severe aortic stenosis (AS). METHODS: Preprocedural high-pitch helical CT datasets were analyzed in 1954 patients undergoing TAVR between 2013 and 2018 â€‹at our center. Patients were stratified into two groups according to the acquisition heart phase (979 systolic and 975 diastolic). The study was approved by the local ethics committee. RESULTS: Median age was 81.6 [interquartile range 77.5-85.8] years and 964 (49.3%) patients were male. No significant difference was found for the Valve Academic Research Consortium-3 (VARC-3) endpoints of technical failure (systolic, 5.1% vs. diastolic, 5.2%, p â€‹= â€‹0.94) or device failure (systolic, 13.7% vs. diastolic, 13.5%, p â€‹= â€‹0.92). There was no difference in paravalvular regurgitation. All-cause 30-day mortality was comparable (systolic, 3.6% [95% confidence interval, 2.4-4.7%] vs. diastolic, 3.6% [2.4-4.8%], p â€‹= â€‹1.00), while 3-year mortality rates were higher in the diastolic group (Society of Thoracic Surgeons score adjusted hazard ratio, 1.25 [1.07-1.46], p â€‹< â€‹0.01). CONCLUSIONS: While the 30-day technical and clinical outcomes after TAVR are comparable between systolic and diastolic CT imaging, diastolic imaging was associated with higher long-term mortality. Therefore, the data support the guideline recommendation of systolic imaging.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Femenino , Soplos Cardíacos/etiología , Humanos , Masculino , Valor Predictivo de las Pruebas , Factores de Riesgo , Tomografía Computarizada por Rayos X/métodos , Resultado del Tratamiento
2.
Clin Res Cardiol ; 111(12): 1325-1335, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35320407

RESUMEN

OBJECTIVES: The study objective was to characterize different groups of low-flow low-gradient (LFLG) aortic stenosis (AS) and determine short-term outcomes and long-term mortality according to Valve Academic Research Consortium-3 (VARC-3) endpoint definitions. BACKGROUND: Characteristics and outcomes of patients with LFLG AS undergoing transcatheter aortic valve implantation (TAVI) are poorly understood. METHODS: All patients undergoing TAVI at our center between 2013 and 2019 were screened. Patients were divided into three groups according to mean pressure gradient (dPmean), ejection fraction (LVEF), and stroke volume index (SVi): high gradient (HG) AS (dPmean ≥ 40 mmHg), classical LFLG (cLFLG) AS (dPmean < 40 mmHg, LVEF < 50%), and paradoxical LFLG (pLFLG) AS (dPmean < 40 mmHg, LVEF ≥ 50%, SVi ≤ 35 ml/m2). RESULTS: We included 1776 patients (956 HG, 447 cLFLG, and 373 pLFLG patients). Most baseline characteristics differed significantly. Median Society of Thoracic Surgeons (STS) score was highest in cLFLG, followed by pLFLG and HG patients (5.0, 3.9 and 3.0, respectively, p < 0.01). Compared to HG patients, odds ratios for the short-term VARC-3 composite endpoints, technical failure (cLFLG, 0.76 [95% confidence interval, 0.40-1.36], pLFLG, 1.37 [0.79-2.31]) and device failure (cLFLG, 1.06 [0.74-1.49], pLFLG, 0.97 [0.66-1.41]) were similar, without relevant differences within LFLG patients. NYHA classes improved equally in all groups. Compared to HG, LFLG patients had a higher 3-year all-cause mortality (STS score-adjusted hazard ratios, cLFLG 2.16 [1.77-2.64], pLFLG 1.53 [1.22-193]), as well as cardiovascular mortality (cLFLG, 2.88 [2.15-3.84], pLFLG, 2.08 [1.50-2.87]). CONCLUSIONS: While 3-year mortality remains high after TAVI in LFLG compared to HG patients, symptoms improve in all subsets after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Índice de Severidad de la Enfermedad , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
3.
JACC Cardiovasc Interv ; 13(21): 2497-2507, 2020 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-33069658

RESUMEN

OBJECTIVES: The aim of this study was to investigate the prevalence and prognostic impact of tricuspid annular dilatation (TAD) measured in multislice computed tomography datasets in patients undergoing transfemoral transcatheter aortic valve replacement for severe aortic stenosis. BACKGROUND: TAD is an increasingly recognized entity associated with poor outcomes in patients with valvular heart disease. METHODS: The maximal septolateral diameter of the tricuspid annulus was measured in consecutive patients with 3-dimensional multidetector row computed tomographic datasets undergoing transfemoral transcatheter aortic valve replacement. Receiver-operating curve characteristic analysis was performed to obtain an ideal, body surface area-normalized cutoff for TAD. Ethical approval was obtained from the institutional ethics board. RESULTS: The study included 1,137 patients, of whom 299 died within a mean follow-up period of 1.8 ± 1.0 years. TAD was identified in 446 patients (39.2%) on the basis of a receiver-operating characteristic cutoff of 23 mm/m2. TAD had no impact on procedural outcomes, including device failure defined according to Valve Academic Research Consortium-2 criteria. Patients with TAD experienced significantly greater mortality (hazard ratio: 1.99; 95% confidence interval: 1.59 to 2.51; p < 0.001). Multivariate analysis including clinical and echocardiographic parameters confirmed the predictive value of TAD (hazard ratio: 1.78; 95% confidence interval: 1.33 to 2.38; p < 0.001), while echocardiographic variables, including estimated pulmonary artery pressure and the severity of tricuspid regurgitation, did not reach statistical significance. The predictive value of TAD was incremental to a baseline model of clinical and echocardiographic parameters (continuous net reclassification improvement 0.204; p < 0.01) and incremental to the Society of Thoracic Surgeons score (continuous net reclassification improvement 0.209; p < 0.001). CONCLUSIONS: TAD is an independent predictor of all-cause mortality in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement.


Asunto(s)
Dilatación , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Tomografía Computarizada Multidetector , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...