Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Cardiovasc Ultrasound ; 22(1): 7, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38858752

RESUMEN

AIMS: To evaluate the feasibility of a transthoracic echocardiogram using an apical-subcostal protocol in invasive mechanical ventilation (IMV) and prone position. METHODS: Prospective study of adults who required a prone position during IMV. A pillow was placed only under the left hemithorax in the prone position to elevate and ease the apical and subcostal windows. A critical care cardiologist (prone group) acquired and evaluated the images using the apical-subcostal protocol. Besides, we used ambulatory echocardiograms performed as a comparative group (supine group). RESULTS: 86 patients were included, 43 in the prone and 43 in the supine. In the prone group, the indication to perform an echocardiogram was hemodynamic monitoring. All patients were ventilated with protective parameters, and the mean end-expiratory pressure was 10.6 cmH2O. The protocol was performed entirely in 42 of 43 patients in the prone group because one patient did not have any acoustic window. In the 43 patients in the prone group analyzed and compared to the supine group, global biventricular function was assessed in 97.7% (p = 1.0), severe heart valve disease in 88.4% (p = 0.055), ruled out of the presence of pulmonary hypertension in 76.7% (p = 0.80), pericardial effusion in 93% (p = 0.12), and volume status by inferior vena cava in 93% (p = 0.48). Comparing prone versus supine position, a statistical difference was found when evaluating the left ventricle apical 2-chamber view (65.1 versus 100%, p < 0.01) and its segmental function (53.4 versus 100%, p < 0.01). CONCLUSION: The echocardiogram using an apical-subcostal protocol is feasible in patients in the IMV and prone position.


Asunto(s)
Ecocardiografía , Estudios de Factibilidad , Unidades de Cuidados Intensivos , Respiración Artificial , Humanos , Masculino , Posición Prona , Femenino , Estudios Prospectivos , Respiración Artificial/métodos , Ecocardiografía/métodos , Persona de Mediana Edad , Posicionamiento del Paciente/métodos , Anciano
2.
JACC Case Rep ; 28: 102087, 2023 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-38204533

RESUMEN

We present a female patient with heart failure with reduced ejection fraction who underwent left bundle branch cardiac resynchronization therapy. Left bundle branch lead implantation was complicated with septal branch perforation causing an iatrogenic coronary fistula complicated by septal hematoma formation and development of shock. Occlusion by covered stents was successfully achieved.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA