Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Circ Cardiovasc Interv ; 10(11)2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29089313

RESUMEN

BACKGROUND: Interventional cardiologists are increasingly exposed to radiation-induced diseases like cataract and the stochastic risk of left-sided brain tumors. The RADPAD is a sterile, disposable, lead-free shield placed on the patient with the aim to minimize operator-received scatter radiation. The objective of the trial was to examine the RADPAD's efficacy in a real-world situation. METHODS AND RESULTS: In the current, double-blind, sham-controlled, all-comer trial, patients undergoing diagnostic catheterization or percutaneous coronary interventions were randomized in a 1:1:1 ratio to a radiation absorbing shield (RADPAD), standard treatment (NOPAD), or a sham shield (SHAMPAD). The sham shield allowed testing for shield-induced radiation behavior. The primary outcome was the difference in relative exposure of the primary operator between the RADPAD and NOPAD arms and was defined as the ratio between operator's exposure (E in µSv) and patient exposure (dose area product in mGy·cm2), measured per procedure. A total of 766 consecutive coronary procedures were randomized to the use of RADPAD (N=255), NOPAD (N=255), or SHAMPAD (N=256). The use of RADPAD was associated with a 20% reduction in relative operator exposure compared with that of NOPAD (P=0.01) and a 44% relative exposure reduction compared with the use of a SHAMPAD (P<0.001). Use of the SHAMPAD was associated with a 43% higher relative radiation exposure than procedures with NOPAD (P=0.009). CONCLUSIONS: In clinical daily practice, the standard use of the RADPAD radiation shield reduced operator radiation exposure compared with procedures with NOPAD or SHAMPAD. This study supports the routine use of RADPAD in the catheterization laboratory. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03139968.


Asunto(s)
Cateterismo Cardíaco , Cardiólogos , Exposición Profesional/prevención & control , Intervención Coronaria Percutánea , Dosis de Radiación , Exposición a la Radiación/prevención & control , Protección Radiológica/instrumentación , Radiografía Intervencional , Radiólogos , Paños Quirúrgicos , Anciano , Cateterismo Cardíaco/efectos adversos , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Exposición Profesional/efectos adversos , Salud Laboral , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Factores Protectores , Exposición a la Radiación/efectos adversos , Traumatismos por Radiación/etiología , Traumatismos por Radiación/prevención & control , Monitoreo de Radiación , Radiografía Intervencional/efectos adversos , Medición de Riesgo , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA