Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Int Endod J ; 56(10): 1301-1315, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37594701

RESUMEN

AIM: To assess the influence of a flat-side design on the geometry, metallurgy, mechanical performance and shaping ability of a novel nickel-titanium rotary instrument. METHODOLOGY: Sixty-five new 25-mm flat-side rotary instruments (size 25, taper 0.04) and their nonflat-side prototypes (n = 65) were assessed for major deformations and examined regarding macroscopic and microscopic design, determination of nickel and titanium elements ratio, measurement of phase transformation temperature and evaluation of mechanical performance parameters including time/cycles to fracture, maximum torque, angle of rotation, maximum bending and buckling strengths and cutting ability. Additionally, unprepared canal areas, volume of hard tissue debris and percentage reduction of dentine thickness were calculated for each tested instrument after preparing mesial canals of mandibular molars (n = 12), using micro-CT imaging. Statistical analyses were performed using the U-Mann-Whitney test and independent Student t-test (α = 5%). RESULTS: The number of spirals (n = 8) and blade direction (clockwise) were similar between both flat and nonflat instruments, whilst the helical angles were equivalent (⁓25°). Flat-instruments showed inconsistencies in the homogeneity of the gold colour on the flat-side surface, blade discontinuity, and incomplete and variable S-shaped cross-sections. The titanium-to-nickel ratios were equivalent, but significant differences in the R-phase finish and austenitic start phase transformation temperatures were observed between the flat and nonflat-side instruments. The flat-side instruments demonstrated superior cutting ability compared to the nonflat instruments, as well as, significantly lower values for time to fracture, rotation to fracture and maximum torque to fracture (p < .001). No statistical difference was observed between tested instruments regarding angle of rotation (p = .437), maximum bending (p = .152) and buckling load (p = .411). Preparation protocols using flat and nonflat instruments did not show any statistically significant differences (p > .05). All flat-side instruments exhibited deformation after shaping procedures. CONCLUSIONS: The flat-side instrument showcased enhanced cutting ability compared to its nonflat counterpart. However, it exhibited inferior performance in terms of time, rotation and maximum torque to fracture, along with distinct phase transformation temperatures. No differences were observed in the titanium-to-nickel ratios, angle of rotation, maximum bending, buckling load, preparation time, percentage of untouched canal walls, volume of hard tissue debris and percentage reduction of dentine thickness.


Asunto(s)
Níquel , Titanio , Humanos , Cavidad Pulpar , Metalurgia , Diente Molar
2.
Int Endod J ; 56(9): 1024-1041, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37254176

RESUMEN

BACKGROUND: The results of vital pulp treatments in permanent teeth have been encouraging. Currently, pulpotomy treatment for permanent teeth primarily utilizes mineral trioxide aggregate (MTA) as the dressing material, followed by calcium hydroxide. While other calcium-silicate-based cements have been suggested for pulpotomy, there is a limited number of studies evaluating their long-term effectiveness. OBJECTIVES: The objective of this systematic review and meta-analysis was to evaluate the success rate of pulpotomies performed on permanent teeth, comparing the use of ProRoot MTA with that of calcium hydroxide and other bioceramic materials. METHODS: A comprehensive search was conducted in several electronic databases, including PubMed, Cochrane Library, Scopus, Web of Science, Embase and Science Direct until December 2022. The search was guided by PICOS criteria, including only randomized clinical trials (RCTs) that evaluated the success rate of pulpotomy treatments in permanent teeth using ProRoot MTA in comparison to calcium hydroxide and other bioceramic materials. The quality of the included studies was assessed using the RoB-2 tool to evaluate the risk of bias, and relevant data were extracted and analysed in RevMan software 5.3 using fixed-effect models. The GRADE tool was used to determine the overall quality of evidence. RESULTS: The initial search retrieved 1072 studies and, after eliminating duplicates, 677 studies were screened and 28 studies were considered for eligibility. In the final selection process, 16 studies were included in the systematic review, with 10 being determined as having a high risk of bias. Pulpotomy showed an overall mean success rate of 92% after 1 year. The meta-analysis indicated a significantly higher success rate for pulpotomies utilizing MTA in comparison with calcium hydroxide, while no significant difference was seen between MTA and calcium-enriched mixture (CEM) or Biodentine. The GRADE assessment revealed an overall low level of evidence for the included studies. DISCUSSION: Most randomized controlled trials exhibited a significant absence of control over confounding factors. CONCLUSIONS: This systematic review and meta-analysis demonstrate that pulpotomy is a highly effective treatment for managing permanent teeth. The results indicate that the success rate of pulpotomy using ProRoot MTA is significantly higher than when using calcium hydroxide. However, the certainty of evidence supporting these findings is low, and there is a need for well-designed RCTs to assess the long-term outcomes of pulpotomy using newer bioceramic materials. REGISTRATION: This systematic review was registered in the PROSPERO database (registration number CRD42023393970).


Asunto(s)
Hidróxido de Calcio , Pulpotomía , Humanos , Hidróxido de Calcio/uso terapéutico , Pulpotomía/métodos , Calcio , Compuestos de Aluminio/uso terapéutico , Combinación de Medicamentos , Óxidos/uso terapéutico , Ensayos Clínicos Controlados Aleatorios como Asunto , Compuestos de Calcio/uso terapéutico , Resultado del Tratamiento , Silicatos/uso terapéutico
3.
J Endod ; 49(5): 536-543, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36841384

RESUMEN

INTRODUCTION: This study aimed to evaluate the effects of root canal enlargement on the danger zone (DZ) of mandibular molars. METHODS: Thirty mesial roots of mandibular first molars were scanned in micro-computed tomography (S1). Canals were sequentially enlarged with rotary instruments up to sizes 30/0.04 (S2) and 30/0.06 (S3). The dentin thickness was measured at 0.1-mm intervals after each preparation step (n = 2964 slices). Root level and position of the DZ were also recorded. Data were compared using analysis of variance with Bonferroni pairwise comparison, Cochran's Q method, and Pearson's test (α = 5%). RESULTS: Comparing the specimens before (S1) and after (S2 and S3) preparations showed a significant reduction in the thickness of the DZ (P < .05), as well as between S2 and S3 steps (P < .05). At S1, the DZ was mostly located in the middle third of the root, but after preparation, it shifted toward the coronal direction (P < .05). Both S2 (P = .004, r = 0.508) and S3 (P = .004, r = 0.506) preparation steps showed a positive correlation between canal length and the root level of the DZ. At S1, the DZ was positioned toward the distal and mesial in 73.4% (n = 22) and 26.6% (n = 8) of the specimens, respectively. After S3, the number of specimens with DZ positioned toward the mesial aspect of the root significantly reduced to 3.3% (n = 1), whereas none of the specimens with DZ positioned toward the distal changed its position after root canal enlargements (P > .05). CONCLUSION: Overall, the enlargement of mesial canals of mandibular first molars with final instruments sizes 30/0.04 and 30/0.06 affected the thickness, root level, and position of the DZ.


Asunto(s)
Dentina , Mandíbula , Microtomografía por Rayos X , Raíz del Diente/diagnóstico por imagen , Cavidad Pulpar/diagnóstico por imagen , Preparación del Conducto Radicular
4.
Braz Dent J ; 33(4): 47-53, 2022.
Artículo en Portugués | MEDLINE | ID: mdl-36043568

RESUMEN

The present study aimed to perform two different heat-treatments in an austenitic NiTi ProFile instrument and to compare the mechanical performance of original and heat-treated instruments. Heat treatment of ProFile (tip size 25 and 0.06 taper) instruments were carried out in a furnace in argon atmosphere using a heating rate of 10° C/min. After reaching the programmed temperatures of 450 ºC or 500 ºC the system remained at a constant temperature for 10 minutes; followed by cooling in water at room temperature. Afterwards; the three groups (n=30 per group) of instruments were compared regarding their cyclic fatigue (n=10 per group); bending (n=10 per group); and buckling resistance (n=10 per group). After cyclic fatigue tests; a scanning electron microscope was used to analyze the fracture surfaces and observe the fracture mode. Statistical analysis was performed using One-way ANOVA and Student-Newman-Keuls test; with an alpha type error set at 0.05. Yellowish and blueish coloration was observed in the ProFile instruments after 450 ºC or 500 ºC heat treatments; respectively. Conventional ProFile instruments showed the lower cyclic fatigue; and the higher bending and buckling resistance (P<0.05). In contrast; yellowish ProFile instruments (heat treated at 500° C) showed the higher cyclic fatigue; and the lower bending and buckling resistance (P>0.05). It can be concluded that the different heat treatments performed on ProFile instruments increased its cyclic fatigue resistance and improved the flexibility and buckling resistance.


O presente estudo teve como objetivo realizar dois tratamentos térmicos diferentes em instrumentos de NiTi austenítico ProFile e comparar o desempenho mecânico de instrumentos originais e tratados termicamente. O tratamento térmico dos instrumentos ProFile (tamanho de ponta 25 e conicidade 0.06) foi realizado em um forno em atmosfera de argônio usando uma taxa de aquecimento de 10°C/min. Após atingir as temperaturas programadas de 450 ºC ou 500 ºC o sistema permaneceu em temperatura constante por 10 minutos; seguido de resfriamento em água à temperatura ambiente. Em seguida; os três grupos de instrumentos (n=30 por grupo) foram comparados quanto à fadiga cíclica (n=10 por grupo); flexão (n=10 por grupo) e resistência à flambagem (n=10 por grupo). Após testes de fadiga cíclica; um microscópio eletrônico de varredura foi utilizado para analisar as superfícies de fratura e observar o modo de fratura. A análise estatística foi realizada por meio dos testes de One-way ANOVA e teste de Student-Newman-Keuls; com erro de tipo alfa fixado em 0.05. Coloração amarelada e azulada foi observada nos instrumentos ProFile após tratamentos térmicos a 450 ºC ou 500 ºC; respectivamente. Os instrumentos ProFile originais apresentaram menor fadiga cíclica e maior resistência à flexão e flambagem (P<0.05). Em contraste; os instrumentos ProFile azulados (tratados termicamente a 500°C) apresentaram maior fadiga cíclica e menor resistência à flexão e flambagem (P>0.05). Pode-se concluir que os diferentes tratamentos térmicos realizados nos instrumentos ProFile aumentaram sua resistência à fadiga cíclica e melhoraram a flexibilidade e resistência à flambagem.


Asunto(s)
Instrumentos Dentales , Calor , Diseño de Equipo , Humanos , Ensayo de Materiales , Preparación del Conducto Radicular , Estrés Mecánico , Temperatura , Titanio
5.
Materials (Basel) ; 15(15)2022 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-35955223

RESUMEN

This study aimed to compare three endodontic rotary systems. The new Genius Proflex (25/0.04), Vortex Blue (25/0.04), and TruNatomy (26/0.04v) instruments (n = 41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. The results were compared using one-way ANOVA, post hoc Tukey, and Kruskal−Wallis tests, with a significance level set at 5%. All instruments showed symmetrical cross-sections, with asymmetrical blades, no radial lands, no major defects, and almost equiatomic nickel−titanium ratios. Differences were noted in the number of blades, helical angles, cross-sectional design, and tip geometry. The Genius Proflex and the TruNatomy instruments had the highest and lowest R-phase start and finish temperatures, as well as the highest and lowest time and cycles to fracture (p < 0.05), respectively. The TruNatomy had the highest flexibility (p < 0.05), while no differences were observed between the Genius Proflex and the Vortex Blue (p > 0.05). No differences among tested systems were observed regarding the maximum torque, angle of rotation prior to fracture, and shaping ability (p > 0.05). The instruments showed similarities and differences in their design, metallurgy, and mechanical properties. However, their shaping ability was similar, without any clinically significant errors. Understanding these characteristics may help clinicians to make decisions regarding which instrument to choose for a particular clinical situation.

6.
Braz. dent. j ; 33(4): 47-53, July-Aug. 2022. tab, graf
Artículo en Portugués | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1394087

RESUMEN

Resumo O presente estudo teve como objetivo realizar dois tratamentos térmicos diferentes em instrumentos de NiTi austenítico ProFile e comparar o desempenho mecânico de instrumentos originais e tratados termicamente. O tratamento térmico dos instrumentos ProFile (tamanho de ponta 25 e conicidade 0.06) foi realizado em um forno em atmosfera de argônio usando uma taxa de aquecimento de 10°C/min. Após atingir as temperaturas programadas de 450 ºC ou 500 ºC o sistema permaneceu em temperatura constante por 10 minutos; seguido de resfriamento em água à temperatura ambiente. Em seguida; os três grupos de instrumentos (n=30 por grupo) foram comparados quanto à fadiga cíclica (n=10 por grupo); flexão (n=10 por grupo) e resistência à flambagem (n=10 por grupo). Após testes de fadiga cíclica; um microscópio eletrônico de varredura foi utilizado para analisar as superfícies de fratura e observar o modo de fratura. A análise estatística foi realizada por meio dos testes de One-way ANOVA e teste de Student-Newman-Keuls; com erro de tipo alfa fixado em 0.05. Coloração amarelada e azulada foi observada nos instrumentos ProFile após tratamentos térmicos a 450 ºC ou 500 ºC; respectivamente. Os instrumentos ProFile originais apresentaram menor fadiga cíclica e maior resistência à flexão e flambagem (P<0.05). Em contraste; os instrumentos ProFile azulados (tratados termicamente a 500°C) apresentaram maior fadiga cíclica e menor resistência à flexão e flambagem (P>0.05). Pode-se concluir que os diferentes tratamentos térmicos realizados nos instrumentos ProFile aumentaram sua resistência à fadiga cíclica e melhoraram a flexibilidade e resistência à flambagem.


Abstract The present study aimed to perform two different heat-treatments in an austenitic NiTi ProFile instrument and to compare the mechanical performance of original and heat-treated instruments. Heat treatment of ProFile (tip size 25 and 0.06 taper) instruments were carried out in a furnace in argon atmosphere using a heating rate of 10° C/min. After reaching the programmed temperatures of 450 ºC or 500 ºC the system remained at a constant temperature for 10 minutes; followed by cooling in water at room temperature. Afterwards; the three groups (n=30 per group) of instruments were compared regarding their cyclic fatigue (n=10 per group); bending (n=10 per group); and buckling resistance (n=10 per group). After cyclic fatigue tests; a scanning electron microscope was used to analyze the fracture surfaces and observe the fracture mode. Statistical analysis was performed using One-way ANOVA and Student-Newman-Keuls test; with an alpha type error set at 0.05. Yellowish and blueish coloration was observed in the ProFile instruments after 450 ºC or 500 ºC heat treatments; respectively. Conventional ProFile instruments showed the lower cyclic fatigue; and the higher bending and buckling resistance (P<0.05). In contrast; yellowish ProFile instruments (heat treated at 500° C) showed the higher cyclic fatigue; and the lower bending and buckling resistance (P>0.05). It can be concluded that the different heat treatments performed on ProFile instruments increased its cyclic fatigue resistance and improved the flexibility and buckling resistance.

7.
Int Endod J ; 55(7): 795-807, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35383977

RESUMEN

AIM: To assess the interfacial adaptation (gap-containing areas) of two root canal sealers (EndoSequence BC Sealer and AH Plus) to a conventional gutta-percha (GP) cone (GP-sealer interface) in oval-shaped canals filled using the single cone technique. METHODOLOGY: Sixteen teeth with oval-shaped canals were selected, scanned in a micro-computed tomographic device, and pair-matched according to the volume, aspect ratio and configuration of root canals. Root canals were then sequentially prepared with WaveOne Gold Primary and Large instruments, followed by filling with WaveOne Large GP points associated with either the premixed calcium-silicate EndoSequence BC Sealer or the epoxy resin-based AH Plus sealer (n = 8 per group) using the single cone technique. After 7 days stored in phosphate-buffered saline solution at 37°C, the specimens were rescanned and the reconstructed images segmented in order to differentiate the filling materials (sealer and GP cone) to the dentine. A total of 453 cross-sectional slices were assessed and categorized according to the presence or absence of gaps at the GP-sealer interface. Mann-Whitney U-test verified the differences between groups and were considered significant at alpha = 5%. RESULTS: Gaps were non-homogenously distributed in two-dimensional axial cross-section images and none of the specimens showed completely gap-free areas along the entire GP-sealer interface. Root canals filled with EndoSequence BC Sealer and AH Plus displayed 171 (37.75%) and 136 (30.02%) slices with gaps in the GP-sealer interface and these frequencies were statistically significant (p = .000). CONCLUSIONS: Although none of the specimens had a gap-free area along the entire GP-sealer interface, oval canals filled with AH Plus showed less gaps than the ones filled with EndoSequence BC Sealer.


Asunto(s)
Gutapercha , Materiales de Obturación del Conducto Radicular , Estudios Transversales , Cavidad Pulpar/diagnóstico por imagen , Resinas Epoxi , Ensayo de Materiales , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular , Microtomografía por Rayos X
8.
Int Endod J ; 54(9): 1653-1658, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33977555

RESUMEN

AIM: To compare the bond strength of an epoxy resin-based sealer and two calcium silicate-based sealers (CSS) to gutta-percha discs using a new method. METHODOLOGY: Round discs of gutta-percha (n = 60), measuring 10 mm in diameter and 2 mm in thickness, were placed on a glass plate and a drop of each sealer (AH Plus, EndoSequence BC Sealer and EndoSeal MTA) was placed on their surface. Another identical disc was placed onto the first one and a standardized weight (0.0981 N) applied over them using a specially developed apparatus. Ten samples prepared for each sealer were submitted to a microshear bond strength test accomplished by a specially designed set-up coupled to a universal testing machine. The Kruskal-Wallis test followed by a post hoc procedure was used to compare groups considering the preliminary analysis of the raw data had indicated the nonadherence to a Gaussian distribution (Shapiro-Wilk, p < .05). Alpha error was set at 5%. RESULTS: Overall, no premature failure occurred. All sealers had some degree of adhesiveness to gutta-percha discs but with a significant difference amongst them (Kruskal-Wallis, p = .019). The epoxy resin-based sealer (AH Plus) had significantly higher median shear bond strength values (1.43 MPa; 1.40-1.83) compared to EndoSeal MTA (0.53 MPa; 0.46-0.73) (p = .021) and EndoSequence BC Sealer (0.45 MPa; 0.34-0.46) (p = .023), whilst the lowest median value was observed with EndoSequence BC Sealer (0.45 MPa; 0.34-0.46) (p < .05). CONCLUSIONS: CSS sealers had weaker bonding to gutta-percha when compared to the epoxy resin-based AH Plus sealer. The proposed methodology is an innovative and reproducible method for testing the bond strength of root canal sealers to gutta-percha.


Asunto(s)
Recubrimiento Dental Adhesivo , Materiales de Obturación del Conducto Radicular , Cavidad Pulpar , Resinas Epoxi , Gutapercha , Ensayo de Materiales , Obturación del Conducto Radicular , Silicatos
9.
J Endod ; 47(2): 309-314, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33096193

RESUMEN

INTRODUCTION: The aim of this study was to evaluate the influence of rotary (ProTaper Next [PTN; Dentsply Maillefer, Ballaigues, Switzerland] and ProTaper Gold [PTG, Dentsply Maillefer]) and reciprocating (WaveOne Gold [WOG, Dentsply Maillefer]) systems in dentinal microcrack generation after the preparation of curved root canals using micro-computed tomographic analysis. METHODS: Twenty-four human mandibular molars with curved roots were scanned in a micro-computed tomographic device using an isotropic resolution of 6.78 µm and randomly assigned into 1 of 3 experimental groups (n = 8) according to the root canal instrumentation system used (PTN, PTG, or WOG). Then, the root canals were prepared up to PTN X2, PTG F2, and WOG Primary instruments in the PTN, PTG, and WOG groups, respectively. After canal preparation, each specimen was scanned again. Pre- and postoperative cross-sectional images of the roots (N = 35,304) were analyzed to identify the presence of dentinal microcracks. RESULTS: Overall, 26% of the images presented dentinal defects (n = 9188). Dentinal microcracks were observed in 24.6%, 26%, and 27.4% of the postinstrumentation images from the PTN, PTG, and WOG groups, respectively. However, all of these dentinal microcracks were already present in the corresponding preoperative images. No new microcracks were generated after the preparation of curved root canals of mandibular molars using the aforementioned systems. CONCLUSIONS: Root canal instrumentation with PTN, PTG, and WOG systems did not induce the formation of new dentinal microcracks.


Asunto(s)
Cavidad Pulpar , Oro , Estudios Transversales , Cavidad Pulpar/diagnóstico por imagen , Dentina/diagnóstico por imagen , Humanos , Preparación del Conducto Radicular , Microtomografía por Rayos X
10.
J Endod ; 46(9): 1195-1203, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32525058

RESUMEN

INTRODUCTION: This study evaluated the microbiological conditions of the apical root canal system of teeth with posttreatment apical periodontitis and correlated them with observations from cone-beam computed tomographic (CBCT) imaging, micro-computed tomographic (micro-CT) imaging, and histopathology. METHODS: Root apices were obtained from 36 root canal-treated teeth subjected to periradicular surgery. CBCT examination was available before surgery. The apical root specimens were scanned in a micro-CT device and then cryopulverized. The powder was subjected to DNA extraction for real-time polymerase chain reaction quantification of total bacteria, Streptococcus species, members of the phylum Actinobacteria, and Enterococcus faecalis. Microbiological findings were evaluated for associations with CBCT, micro-CT, and histopathologic data. An association between lesion size and the proportion of unfilled apical canal system volume was also assessed. RESULTS: All cryopulverized specimens were positive for total bacteria. Actinobacteria and streptococci occurred in 35 and 33 specimens, respectively, and were usually dominant in the community. Actinobacteria counts were 2.23 times higher in granulomas than in cysts. Streptococci were significantly more present in small lesion cases. E. faecalis was detected in only 7 samples, always as a dominant community member. The association of total bacteria, streptococci, and Actinobacteria counts with the unfilled canal volume was significant in the univariate analyses but not confirmed in the adjusted analyses. Large lesions were significantly associated with a higher volume of unfilled apical canals. CONCLUSIONS: Bacterial infection occurred in all root apices, with high prevalence and dominance of Actinobacteria and streptococci. The volume of the unfilled apical canal system was significantly associated with the lesion size and possibly with bacterial counts. Findings illustrate the need to thoroughly disinfect and fill the apical root canal of infected teeth during endodontic therapy.


Asunto(s)
Cavidad Pulpar , Periodontitis Periapical , Enterococcus faecalis , Humanos , Tratamiento del Conducto Radicular , Ápice del Diente
11.
Br Dent J ; 227(3): 228-234, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31399682

RESUMEN

Objectives To evaluate the effectiveness of passive ultrasonic irrigation (PUI) compared with non-activated irrigation (NAI) on periapical healing and root canal disinfection.Data source A comprehensive search without restrictions was performed in the following systematic electronic databases: PubMed, Scopus, Cochrane, Web of Science, ScienceDirect and OpenGrey. Additional studies were sought through hand-searching in the main endodontic journals.Data selection We included clinical trials that compared PUI and NAI clinical success and root canal disinfection outcomes. The risk of bias was assessed based on the Cochrane Collaboration common scheme for bias assessment. The power analysis of each study was calculated based on the disinfection rates and sample size, and the evidence was qualified using the GRADE tool.Data synthesis A total of 346 non-duplicated studies were retrieved in the systematic search. One study that assessed the clinical success rate through periapical radiographic healing evaluation and two studies that evaluated root canal disinfection through bacterial growth were considered eligible. These three studies were classified as low risk of bias. The study evaluating radiographic treatment outcome showed no statistical difference (P >0.05). The studies demonstrated large variability among methodology and, in general, low power and moderate evidence. Inconclusive results were reported regarding root canal disinfection when comparing PUI to NAI strategies.Conclusions Based on the findings, there was no evidence of effectiveness improvement on periapical healing and bacterial disinfection that supports the use of PUI over the NAI in clinical practice.


Asunto(s)
Cavidad Pulpar , Irrigantes del Conducto Radicular , Desinfección , Humanos , Preparación del Conducto Radicular , Tratamiento del Conducto Radicular , Irrigación Terapéutica , Ultrasonido
12.
Braz Dent J ; 30(1): 31-35, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30864644

RESUMEN

The aim of this study was to evaluate whether amplifying the volume and/or time of contact of NaOCl affects the fracture strength of endodontically treated bovine teeth. Four bovine incisors from 10 animals were allocated into 4 groups using a split-mouth design. Root canals were instrumented using a sequence of 4 manual stainless steel files and irrigated with a 5.25% alkalized NaOCl solution. The total volume and time of irrigation, per sample, varied among the groups as following: standard volume and time of contact - 15 mL/11.5 min; volume raise - 30 mL/11.5 min; time of contact raise - 15 mL/19 min; and volume and time of contact raise - 30 mL/19 min. Samples were subjected to a fracture resistance assay. At p=0.05, two-way ANOVA statistically scrutinized the results. Effect size of NaOCl time of contact and volume were also calculated (η2). The variation in time (p=0.000), volume of irrigation (p=0.000) and the combination of both (p=0.038) negatively influenced the fracture resistance. Standard volume and time of irrigation showed the highest fracture strength while isolated increase in volume or time reduced in 25% and 37%, respectively, the fracture resistance; the simultaneous increase in volume and time of irrigation promoted a reduction of 47%. Effect size of NaOCl time of contact was superior (0.746) than the volume (0.564). Raising the volume and/or time of a 5.25% alkalized NaOCl solution reduces the fracture resistance of endodontically treated bovine teeth.


Asunto(s)
Tratamiento del Conducto Radicular , Hipoclorito de Sodio/química , Fracturas de los Dientes , Animales , Bovinos , Análisis del Estrés Dental , Incisivo , Hipoclorito de Sodio/administración & dosificación , Irrigación Terapéutica/métodos
13.
Braz. dent. j ; 30(1): 31-35, Jan.-Feb. 2019. graf
Artículo en Inglés | LILACS | ID: biblio-989430

RESUMEN

Abstract The aim of this study was to evaluate whether amplifying the volume and/or time of contact of NaOCl affects the fracture strength of endodontically treated bovine teeth. Four bovine incisors from 10 animals were allocated into 4 groups using a split-mouth design. Root canals were instrumented using a sequence of 4 manual stainless steel files and irrigated with a 5.25% alkalized NaOCl solution. The total volume and time of irrigation, per sample, varied among the groups as following: standard volume and time of contact - 15 mL/11.5 min; volume raise - 30 mL/11.5 min; time of contact raise - 15 mL/19 min; and volume and time of contact raise - 30 mL/19 min. Samples were subjected to a fracture resistance assay. At p=0.05, two-way ANOVA statistically scrutinized the results. Effect size of NaOCl time of contact and volume were also calculated (η2). The variation in time (p=0.000), volume of irrigation (p=0.000) and the combination of both (p=0.038) negatively influenced the fracture resistance. Standard volume and time of irrigation showed the highest fracture strength while isolated increase in volume or time reduced in 25% and 37%, respectively, the fracture resistance; the simultaneous increase in volume and time of irrigation promoted a reduction of 47%. Effect size of NaOCl time of contact was superior (0.746) than the volume (0.564). Raising the volume and/or time of a 5.25% alkalized NaOCl solution reduces the fracture resistance of endodontically treated bovine teeth.


Resumo O objetivo desse estudo foi o de avaliar se o aumento de volume e/ou tempo de contato do NaOCl afeta a resistência à fratura de dentes bovinos tratados endodonticamente. Quatro incisivos bovinos de 10 animais foram alocados em 4 grupos usando um desenho experimental de boca dividida. Os canais radiculares foram instrumentados usando uma sequência de 4 limas manuais de aço inoxidável e irrigados com uma solução de NaOCl alcalinizada a 5,25%. O volume total e o tempo de irrigação, por amostra, variaram entre os grupos da seguinte forma: volume e tempo de contato padrão (grupo controle) - 15 mL/11,5 min; aumento de volume - 30 mL/11,5 min; aumento no tempo de contato - 15 mL/19 min; e aumento no volume e no tempo de contato - 30 mL/19 min. As amostras foram submetidas a um ensaio de resistência à fratura. Com p=0.05, o teste two-way ANOVA analisou estatisticamente os resultados. O tamanho do efeito do tempo de contato e volume de NaOCl também foi calculado (h2). A variação no tempo (p=0,000), no volume de irrigação (p=0,000) e a interação entre ambos (p=0.038) influenciaram negativamente a resistência à fratura. O volume e o tempo padrão de irrigação apresentaram a maior resistência à fratura, enquanto o aumento isolado no volume ou no tempo de contato reduziram 25% e 37%, respectivamente, a resistência à fratura; o aumento simultâneo do volume e tempo de irrigação promoveu uma redução de 47%. O tamanho do efeito do tempo de contato com o NaOCl foi superior (0,746) ao volume (0,564). Aumentando o volume e/ou o tempo de uma solução de NaOCl alcalinizada a 5,25% reduz a resistência à fratura de dentes bovinos tratados endodonticamente.


Asunto(s)
Animales , Tratamiento del Conducto Radicular , Hipoclorito de Sodio/química , Fracturas de los Dientes , Hipoclorito de Sodio/administración & dosificación , Bovinos , Análisis del Estrés Dental , Incisivo , Irrigación Terapéutica/métodos
14.
J Oral Sci ; 58(3): 347-51, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27665973

RESUMEN

This study compared the effectiveness of clinical observation, clinical microscopic observation, and tooth-clearing technique in determining the number of canals in mandibular incisors. Root canal ramifications were also analyzed. Using clinical and microscopic analyses, we determined the number of canal entrances in 277 mandibular incisors. In addition, tooth-clearing technique was used to determine the number of canals and frequency of ramifications in the samples. The kappa coefficient was used to compare the different methods with regard to frequency of canals. Most teeth had one canal entrance. The proportion of teeth with two canals was 23.5% by tooth-clearing analysis, 5.8% by clinical microscopy, and 1.1% by clinical analysis. A large number of samples had some type of ramification (40.1%), and most ramifications were present in teeth with two canals. The most frequent ramification was lateral canals (8.3%). Clinical microscopy improved identification of a second canal in mandibular incisors. However, it did not identify second canals in all teeth with two canals. (J Oral Sci 58, 347-351, 2016).


Asunto(s)
Cavidad Pulpar/anatomía & histología , Incisivo/anatomía & histología , Mandíbula/anatomía & histología , Humanos
15.
J Oral Sci ; 58(2): 211-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27349542

RESUMEN

We evaluated the cytotoxic effects of the debris apically extruded during root canal retreatment on primary human osteoblast (HOb) cells in vitro. TNF-α and IL-1ß levels were also measured. We examined three different techniques: conventional hand-files, and Mtwo and Reciproc retreatments. Filled mandibular incisors were prepared for a cytotoxicity assay in an experimental root model. The material was divided into three groups according to the technique used. Ten teeth were used as control. HOb cells were exposed to the extruded content and cytotoxicity was evaluated using the MTT test (assessing cell metabolic activity). TNF-α and IL-1ß production was also analyzed using enzyme-linked immunosorbent assay. Then, all the teeth were radiographed and the residual filling material was quantified. Data were subjected to analysis of variance (ANOVA) and Tukey's test (P < 0.05). The conventional hand-file technique was significantly more cytotoxic than the other methods (P < 0.05). Reciproc was less cytotoxic than Mtwo retreatment (P < 0.05). All endodontic retreatment techniques led to a significant upregulation of IL-1ß levels (P < 0.05). However, only the conventional hand-file technique caused a significant increase in TNF-α levels (P < 0.05). Root-filling removal did not affect the levels of these proteins (P > 0.05). The Reciproc system required less time than the other two methods to remove the root-filling materials (P < 0.01). The endodontic retreatment with Reciproc was the least cytotoxic and the least time-consuming method of gutta-percha and sealer removal. (J Oral Sci 58, 211-217, 2016).


Asunto(s)
Tratamiento del Conducto Radicular , Ápice del Diente , Línea Celular , Gutapercha , Humanos
16.
RSBO (Impr.) ; 9(3): 309-315, Jul.-Sep. 2012. tab
Artículo en Inglés | LILACS | ID: lil-748130

RESUMEN

Introduction: Considered the most serious of dental injuries, avulsion is known as the total displacement of tooth out of its socket. Treatment includes immediate replantation and its success is directly related to several factors. Objective: This paper aimed to review the literature in a systematic way on dental avulsion of permanent teeth with open apex, covering various topics such as: reason for avulsion; storage media; time out of the socket; use of antibiotics; splinting time; tooth vitality; presence of resorption and/or obliteration of pulp canal; and following-up time. Material and methods: PubMed/MedLine database and Dental Traumatology journal were searched, from May to June of 2011, and several studies comprising the current and classic literature were listed using the following terms: tooth avulsion, open apex, permanent and case report. Results and conclusion: Twelve cases reports were selected. Cases of dental trauma in open apex teeth may have a good prognosis if the following steps are taken: the hydration of the tooth and immediately replantation. It is important to search dental care, even if everything seems solved, and the tooth following-up should be performed periodically as informed by the dentist.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...