Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Laryngoscope ; 104(8 Pt 1): 927-31, 1994 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-8052075

RESUMEN

Reported cases of toxic shock syndrome (TSS) following nasal surgery or functional endonasal sinus surgery (FESS) are uncommon. Classic TSS is a serious multisystem disorder resulting from Staphylococcus aureus phage I toxic shock syndrome toxin 1 (TSST-1), and it is characterized by fever, rash, hypotension, mucosal hyperemia, vomiting, diarrhea, and laboratory evidence of multisystem organ dysfunction. TSS cases following nasal surgery have been associated with nasal packing, mucosal barrier violation, prior S aureus phage I colonization, as well as low antitoxin antibody levels. Of the 1700 FESS procedures performed at our institution, 3 cases were complicated by classic TSS, with 2 additional patients having a postsurgical course compromised by a milder degree of TSS. Diagnostic criteria, clinical presentation, management, and etiology are discussed, and the possibility of a continuum from mild-to-classic TSS is addressed.


Asunto(s)
Nariz/cirugía , Enfermedades de los Senos Paranasales/cirugía , Choque Séptico/etiología , Infecciones Estafilocócicas , Adolescente , Adulto , Niño , Femenino , Humanos , Masculino , Seno Maxilar/cirugía , Mucocele/cirugía , Pólipos Nasales/cirugía , Tabique Nasal/cirugía , Complicaciones Posoperatorias , Sinusitis/cirugía , Seno Esfenoidal/cirugía , Tampones Quirúrgicos/efectos adversos
2.
J Emerg Med ; 12(3): 325-30, 1994.
Artículo en Inglés | MEDLINE | ID: mdl-8040589

RESUMEN

During the 18-year period from 1975 to 1992, the Consumer Product Safety Commission's National Electronic Injury Surveillance System database received reports of 18 burn injuries caused by model rocketry sets and their engines. Children in the age range of 11 to 15 years, who frequently use the products inappropriately, are the pediatric population most at risk. Unfortunately, current regulations do not impose age restrictions on the purchase or use of these products; consequently, the industry sets its own age limits. The current regulations appear to be inadequate and need to be altered to cover the population at risk. Specific recommendations include imposing an adequate age limit and improving the labelling of these products. Two case reports are presented that exemplify the typical burn injuries sustained from model rocket engine accidents.


Asunto(s)
Quemaduras Químicas/etiología , Sustancias Peligrosas/efectos adversos , Pasatiempos , Juego e Implementos de Juego , Adolescente , Niño , Seguridad de Productos para el Consumidor , Urgencias Médicas , Sustancias Peligrosas/normas , Humanos , Masculino
3.
Am J Emerg Med ; 12(1): 98-104, 1994 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8285988

RESUMEN

The frequency of correctable malocclusion makes it imperative that the condition be diagnosed and referred for appropriate treatment. A complete dentofacial examination, which assesses facial symmetry and the dentition in the transverse, sagittal, and centric relations, is appropriate. Early diagnosis is imperative because malocclusion leads to long-term complications such as temporomandibular joint (TMJ) dysfunctions, perodontal disease, obstructive sleep apnea, psychological disorders, and articulation errors. A combination of orthodontic treatment and orthognathic surgery will correct the dentoskeletal malocclusion and prevent any long-term complications. The purpose of this case report is to describe a patient with severe dentoskeletal malocclusion who benefitted from appropriate orthodontic treatment and orthognathic surgery.


Asunto(s)
Maloclusión/diagnóstico , Adulto , Femenino , Humanos , Maloclusión/terapia , Maloclusión de Angle Clase III/complicaciones , Ortodoncia Correctiva , Prognatismo/complicaciones
4.
Burns ; 19(5): 441-3, 1993 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-8105800

RESUMEN

The use of aluminium ladders around high voltage power lines has resulted in a significant number of electrical injuries and electrocutions. Workers often misjudge wire distances or lose control of fully extended ladders, thereby exposing themselves to electrocution hazard. High-voltage electrical burns of two workers using an aluminium ladder that contacted a high voltage power line are reported. The circumstances surrounding the injury, the clinical management of the case, and the methods of prevention are presented and discussed.


Asunto(s)
Accidentes de Trabajo , Quemaduras por Electricidad/patología , Breas , Quemaduras por Electricidad/etiología , Traumatismos de los Pies , Traumatismos de la Mano/etiología , Traumatismos de la Mano/patología , Humanos , Masculino , Persona de Mediana Edad
5.
Am Surg ; 58(8): 458-62, 1992 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-1642380

RESUMEN

A new, compound-curved needle has been designed and developed for vascular surgery from a unique stainless steel alloy, American Society for Testing Materials (ASTM) 45500. This needle has two different radii of curvature and a relatively straight body followed by a short, curved tapered point. Despite its geometry, it exhibits a similar sharpness, as well as resistance to bending and breakage, as did a curved needle with a single radius of curvature manufactured from the same alloy. The design of this new needle enabled the surgeon to pass it through the vessel wall with greater accuracy to a controlled depth and length of bite than the curved cutting edge needle with a single radius of curvature.


Asunto(s)
Agujas , Técnicas de Sutura/instrumentación , Procedimientos Quirúrgicos Vasculares/instrumentación , Fenómenos Biomecánicos , Diseño de Equipo , Estudios de Evaluación como Asunto , Humanos , Ensayo de Materiales , Agujas/normas , Acero Inoxidable , Resistencia a la Tracción
6.
J Oral Maxillofac Surg ; 50(5): 484-9, 1992 May.
Artículo en Inglés | MEDLINE | ID: mdl-1573483

RESUMEN

A new compound curved tapercut needle has been designed and developed for oral mucous membrane closure from a unique stainless steel alloy, American Society for Testing Materials (ASTM) 45500. This tapercut needle has a short, relatively straight point, followed by a curved distal section. Despite its geometry, it exhibited similar sharpness as well as resistance to bending and breakage, as did the standard tapercut needle with a single radius of curvature manufactured from the same alloy. The design of this new needle enabled the surgeon to pass it through the oral mucous membrane with a greater accuracy to a controlled depth and length of bite than the standard tapercut needle with a single radius of curvature. In addition, the new needle design aids in the suturing of mucous membranes in confined spaces.


Asunto(s)
Agujas , Instrumentos Quirúrgicos , Elasticidad , Diseño de Equipo , Falla de Equipo , Humanos , Ensayo de Materiales , Mucosa Bucal/cirugía , Acero Inoxidable/química , Estrés Mecánico , Propiedades de Superficie , Técnicas de Sutura/instrumentación
7.
J Emerg Med ; 10(1): 13-8, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1629585

RESUMEN

Although multiple sclerosis and Hodgkin's disease are reported to have similar epidemiologic features, this is only the first case report in which there was concurrence of these diseases. Fourteen years after successful treatment of Hodgkin's disease, this 31-year-old white male developed multiple sclerosis. The diagnosis of multiple sclerosis was made on the basis of clinical and paraclinical findings that were characteristic of multiple sclerosis. In addition, specific tests were performed to rule out a variety of infectious, metabolic, and neoplastic diseases that simulate multiple sclerosis.


Asunto(s)
Enfermedad de Hodgkin/complicaciones , Esclerosis Múltiple/etiología , Adulto , Diagnóstico Diferencial , Humanos , Masculino , Esclerosis Múltiple/diagnóstico , Factores de Riesgo , Factores de Tiempo
8.
J Oral Maxillofac Surg ; 49(11): 1198-203, 1991 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-1941334

RESUMEN

A new tapercut needle has been designed and developed for closure of the oral mucous membrane in oral surgery. It is a sharp needle with short cutting edges that easily penetrates through a small needle puncture hole. It is manufactured from a unique stainless steel alloy that resists bending and fracture. Biomechanical performance tests and clinical experience confirm its superiority over the standard reverse cutting edge needle for use in oral surgery.


Asunto(s)
Agujas , Cirugía Bucal/instrumentación , Fenómenos Biomecánicos , Diseño de Equipo , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Acero Inoxidable , Resistencia a la Tracción
9.
Ann Plast Surg ; 27(4): 339-44, 1991 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-1772225

RESUMEN

A new compound-curved needle has been designed and developed for microvascular surgery from a unique stainless steel alloy, American Society for Testing Materials 45500. This needle has two distinct radii of curvature and a short tapered point, followed by a curved distal section. Despite its geometry, it exhibits similar resistance to bending and breakage as a curved needle with a single radius of curvature manufactured from the same alloy. The design of this new needle enables plastic surgeons to pass it through vessel walls with greater accuracy to a controlled depth and length of bite than a curved needle with a single radius of curvature.


Asunto(s)
Microcirugia/instrumentación , Agujas , Acero Inoxidable , Procedimientos Quirúrgicos Vasculares/instrumentación , Humanos , Estrés Mecánico , Resistencia a la Tracción
10.
Am Surg ; 57(9): 591-601, 1991 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-1929004

RESUMEN

Standardized reproducible tests have been developed to determine the biomechanical performance of cardiovascular needles. The parameters used to assess performance were: 1) sharpness, 2) resistance to bending, and 3) ductility. Four comparable groups of tapercut and taper point cardiovascular needles were selected from different manufacturers for these biochemical studies. The results of this testing demonstrated that needle geometry, needle composition, and the manufacturer were important determinants of needle performance. When comparable needles were evaluated, the biochemical performance of cardiovascular needles manufactured by Ethicon, Inc. (Somerville, NJ) were superior to needles produced by other manufacturers. The superior performance characteristics of the cardiovascular needles produced by Ethicon, Inc. were related to their unique stainless steel alloy, American Society for Testing Materials 45500, which has greater yield and tensile strengths than the alloy used by the other manufacturers. This stainless steel alloy was ideal for the production of tapercut needles, which combined some of the features of a reverse cutting edge needle and taper point needle. Its very short cutting edges allowed it to penetrate the membrane at considerably lower penetration forces than were encountered with comparable taper point needles. In addition, the investigation indicated that the trocar point cardiovascular needles produced a large triangular defect whose diameter was much larger than that of the needle body. For this reason, the use of the trochar point needle is not recommended in cardiovascular surgery.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/instrumentación , Agujas , Procedimientos Quirúrgicos Vasculares/instrumentación , Fenómenos Biomecánicos , Fenómenos Biofísicos , Biofisica , Diseño de Equipo , Humanos , Fenómenos Físicos , Física , Equipo Quirúrgico
11.
J Burn Care Rehabil ; 12(4): 354-60, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1834676

RESUMEN

An adaptive communication system has been developed for individuals with mobility disorders. It uses specialized computer software and hardware that compensate for this disability. For an individual with a motor-control impairment who is not able to use a keyboard effectively, a computer voice-recognition technology now removes this communication barrier. Speech-recognition systems consist of three basic components: speech processing, speech recognition, and speech understanding. The new Dragon Dictate (Dragon Systems, Inc., Newton, Mass.) is the first large-vocabulary speech recognition system in the personal computer industry that interactively learns a user's vocabulary and mode of speaking and responds to natural language rather than to limited sets of words. This speech-recognition system requires a microprocessor, a display monitor, a printer, and specific software packages, including word-processing and enhanced memory-management software. Important considerations in the use of this speech-recognition system include microphone positioning and training of the system. With the advent of this new voice-recognition computer system, another communication barrier between the disabled and society has been overcome.


Asunto(s)
Equipos de Comunicación para Personas con Discapacidad , Personas con Discapacidad , Programas Informáticos , Humanos , Percepción del Habla
12.
J Emerg Med ; 9(4): 205-9, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1861053

RESUMEN

EMLA is a new topical agent that safely anesthetizes intact skin. The purpose of this study was to determine if this cream could be safely used for anesthetizing wounds. This investigation evaluated the potential toxicity of EMLA cream in wounds by measuring its effect on host defenses and on the biology of wound repair. In contaminated wounds, EMLA cream elicited an exaggerated inflammatory response that damaged host defenses, inviting the development of infection. As a result of these investigations, we do not recommend the use of EMLA cream in wounds.


Asunto(s)
Anestésicos Locales/toxicidad , Bacterias/efectos de los fármacos , Lidocaína/toxicidad , Prilocaína/toxicidad , Cicatrización de Heridas/efectos de los fármacos , Animales , Bacterias/crecimiento & desarrollo , Combinación de Medicamentos , Femenino , Cobayas , Técnicas In Vitro , Inflamación/inducido químicamente , Inflamación/inmunología , Combinación Lidocaína y Prilocaína , Infección de Heridas/inmunología
13.
J Emerg Med ; 9(3): 107-13, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-2050965

RESUMEN

The purpose of this investigation was to determine the influence of knot configuration and tying technique on the mechanical performance of surgical sutures. Multifilament and monofilament nylon sutures were selected for this evaluation because they are commonly used in wound closure. The mechanical performance of these sutures was judged by the following parameters: knot breakage force, configuration of secure knots, and knot run down force. During each test, tension was applied at either rapid or slow rates, which correlates with the physician's speed of tying knots. On the basis of these mechanical performance tests, four throw square (1 = 1 = 1 =1) knots and five throw square (1 = 1 = 1 = 1 = 1) knots are recommended for monofilament nylon and multifilament nylon sutures, respectively, in which the speed of application of forces to the knots is relatively slow. Because these tests can easily be replicated in any laboratory, manufacturers now have a scientific basis for recommending specific tying techniques for their surgical sutures.


Asunto(s)
Técnicas de Sutura , Fenómenos Físicos , Física
14.
J Burn Care Rehabil ; 12(3): 250-6, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1885643

RESUMEN

The BTE Work Simulator (Baltimore, Therapeutic Equipment Co., Hanover, Md.) recreates the work environment by providing a rotatable shaft to which a variety of tools can be attached. The patient can simulate the coordinated muscle and joint movements involved in the work situation, exercising either isometrically or isotonically, and thereby increase the potential for return to work. The BTE Work Simulator has four major components: the exercise head to provide variable resistance, tools that attach to the exercise head, a control console containing a microprocessor that calculates work and power, and the Quest software package (Baltimore Therapeutic Equipment Co.). Quest provides four static/isometric and seven dynamic/isotonic tests that can be used to document the extent of a patient's impairment. In addition, it has daily treatment options and acts as an extensive data base capable of retrieving any stored test or treatment results. This software system greatly facilitates the use of the BTE Work Simulator by providing instant calculations of power and coefficients of variation, immediate patient feedback, graphic expansion of the data, and printed evaluation reports.


Asunto(s)
Simulación por Computador , Ejercicio Físico/fisiología , Terapia Ocupacional/instrumentación , Equipos y Suministros , Humanos , Contracción Isométrica , Modalidades de Fisioterapia/instrumentación , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA